• 제목/요약/키워드: Matrix phantom

검색결과 47건 처리시간 0.02초

혈액정화장치의 현황과 문제점

  • 박한철
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권2호
    • /
    • pp.102-105
    • /
    • 1989
  • In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research.

  • PDF

QA용 두부 팬톰을 이용한 Hitchcoke CT 및 혈관조영 정위적 시스템에 대한 정확도 평가 (Evaluation of Accuracy on Hitchcoke CT/angio localization system using QA head phantom)

  • 김성현;서태석;윤세철;손병철;김문찬;신경섭
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.1-9
    • /
    • 1998
  • 정위적 방사선 수술과 신경외과적 수술분야 에서는 상호보완적인 영상정보를 얻기 위하여 컴퓨터 단층촬영 (CT), 자기공명영상 (MRI) 그리고 혈관조영촬영이 사용된다. 본 연구의 목적은 여러 영상장치와 다목적 QA(Quality Control) 팬톰을 이용하면서, 정위적 방사선수술 및 신경외과적 수술분 야에서 두경부내의 병소에 대한 모양, 크기, 위치를 정확하게 결정하기 위한 3 차원 정위 시스템을 개발하는 것이다. 목표물의 정확한 위치를 정의하기 위하여, Hitchcoke 정위 프레임과 컴퓨터 단층 촬영 (CT)/혈관 조영촬영용 위치측정 보조기구들을 3차원 공간상에 9개의 목표물을 가진 팬톰에 고정하였다. 컴퓨터 단층촬영과 혈관 조영촬영을 이용하여 얻은 기하학적 팬톰의 영상들을 이용하여, 목표물의 3차원 정위좌표를 얻기위한 알고리즘이 개발되었다. 개발된 알고리즘에 의해 계산된 목표물들의 위치는 팬톰의 절대 좌표와 비교 되었고, 각 CT 영상에서의 목표물들은 뇌혈관촬영 영상위에 상호 중첩될 수 있도록 개발 되었다. 512$\times$512 메트릭스와 2mm 슬라이스 두께를 가진 컴퓨터 단층촬영에 있어서는 1.02$\pm$0.17 mm의 평균거리오차를 보였고, 혈관 조영촬영인 경우에는 0.41$\pm$0.05mm 의 평균거리오차를 보였다. 목표물의 위치를 결정하는데 있어서 결과로 나온 정확도는 개발된 시스템이 정위적 방사선수술과 신경외과적수술을 위해 충분히 신뢰성이 있음을 확인해주었다.

  • PDF

PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가 (Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT)

  • 이충운;유연욱;문종운;김윤철
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

뇌 정위 방사선수술의 선량 계산을 위한 몬테카를로 시뮬레이션 코드 개발 (Development of Monte Carlo Simulation Code for the Dose Calculation of the Stereotactic Radiosurgery)

  • 강정구;이동준
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.303-308
    • /
    • 2012
  • 뇌정위 방사선수술의 선량계산을 위해 Geant4 기반의 응용 프로그램을 개발 하였다. 선형가속기에서 발생하는 방사선의 스펙트럼을 입력하기 위하여 사전에 실행하여 구한 스펙트럼에 각 에너지별로 구한 가중치를 곱하여 확률밀도를 구하였다. 이를 누적밀도로 변환하여 입력하도록 하였다. 메신저 클래스를 이용하여 다양한 형태의 MLC 조사면을 설정할 수 있도록 하였다. 갠트리와 테이블의 회전을 모사하기 위하여 rotateX와 rotateY라는 회전행렬을 사용하였다. 월드좌표 속에서 갠트리와 테이블을 정의하여 각각 회전을 구현하였다. 실제 환자의 자료는 CT의 dicom 파일에서 픽셀 크기, 매트릭스 크기 등의 정보와 픽셀의 HU를 밀도로 변환한 파일을 생성한 다음 이 파일을 이용 환자의 모델링에 이용 하였다. 환자의 모델링은 팬텀월드 안에 픽셀의 크기에 해당하는 복셀을 정의하고 이 복셀에 픽셀의 밀도와 이 밀도에 해당하는 물질을 할당해주었다.

몬테칼로 계산을 통한 흡수선량 재구성의 임상적 응용: 변형된 팬텀에서의 총제적 선량재구성 (Clinical Application of Dose Reconstruction Based on Full-Scope Monte Carlo Calculations: Composite Dose Reconstruction on a Deformed Phantom)

  • Yeo, Inhwan;Xu, Qianyi;Chen, Yan;Jung, Jae Won;Kim, Jong Oh
    • 한국의학물리학회지:의학물리
    • /
    • 제25권3호
    • /
    • pp.139-142
    • /
    • 2014
  • 본 연구의 목적은 흡수선량 재구성, 방사선 치료간의 재구성된 선량의 등록, 선량-체적 히스토그램의 생산등을 수행하는 선량 재구성의 임상적 응용시스템을 만들고 그것을 변형된 전립선 팬텀에 적용하는 것이다. 이를 위해 변형가능한 전립선 팬텀을 20 cm 깊이와 40 cm너비의 물팬텀에 집에 넣었다. 이것의 영상을 얻고, 전립선, 정낭 및 항문의 윤곽을 그렸다. 동일 평면에서 네개의 조사문을 이용하여 세기 변조계획을 세웠다.항문에 20 ml의 물풍선을 삽입하여 장기를 변형시켰다. 영상을 다시 획득하여 위 장기의 윤곽을 그렸다. XVMC몬테칼로 코드를 사용하여 두 팬텀및 EPID내에서 선량반응 인자를 계산하였다. 세기변조계획에서 얻어진 방사선을 두팬텀에 조사하여 EPID에서 적분형 영상을 얻었다. Demons 방법을 사용하여 변형된 팬텀을 변형전 팬텀에 등록시켰다. 이를 통해 단위체적별 위치변이 정보를 얻었고 이를 이용해 두 팬텀의 재 구성된 선량을 합하여 변형전 팬텀에 생산해 냈다. 순방향으로 계산된 치료계획 선량을 합산된 재구성된 선량과 비교하였다. 200 cGy에서 전립선과 정낭이 받든 체적은 차이를 거의 보이지 않았으나, 210 cGy 이상에서는 3%가량 차이를 보였다. 항문에서는 150-200 cGy영역에서 재구성된 선량에 의하여 받은 체적은 치료 계획과 비교하여 3% 이상 적었다. 본 연구를 통하여 선량 재구성의 임상적 응용시스템이 성공적으로 만들어 졌다. 변형된 전립선 팬텀에 적용되어 작지 않은 선량의 차이를 목표장기와 보호 장기에 보였다.

자기공명 Tailored-RF 경사자계반향영상법을 이용한 고양이 뇌에서의 First-Pass관찰 (First-Pass Observation using Tailored-RF Gradient Echo (TRFGE) MR Imaging in Cat Brain)

  • 문치웅;노용만
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.209-216
    • /
    • 1995
  • Recently, a new tailored RF gradient echo (TRFGE) sequence was reported. This technique not only enhances the magnetic susceptibility effect but also allows us to measure local changes in brain oxygenation. In this study, a phantom and cat brain experiments were performed on a 4.7 Tesla BIQSPEC (BRUKER) instrument with a 26 cm gradient system. We have demonstrated that the signal intensity (SI) of the TRFGE sequence varies according to the concentration of susceptibility contrast agent. Three capillary tubes with different concentrations of Gd-DTPA (0.01, 0.05, 0.1 mMOI/l) were placed at the middle of a cylindrical water phantom. Using both TRFGE and conventional gradient echo (CGE) sequences, phantom images of the slices which contain all three tubes were obtained. For the animal experiment, cats were anesthetized and ventilated using halotane (0.5%) and a $N_2O/ O_2$ mixture (2:1), and blood pressure and heart rate were monitored and kept normal. For the observation of tue first pass of Gd- DTPA, imaging was started at t = 0. At t = 8 ~ 12s, 0.2 mMol/Kg Gd-DTPA was manually injected in the femoral vein. The imaging parameters were TRITE = 25/10 msec, flip angle = $30^{\circ}$, FOV = 10cm, image matrix size = $128{\times}128$ with 64 phase encodings and the image data acquisition window was 10 msec. SI-time curves were then obtained from a series of 30 images which were collected at 2 sec intervals using both CGE and TRFGE pulse sequences before, during, and following the contrast injection.

  • PDF

뇌 정위 생검술을 위한 영상지원 3차원 국재 프로그램 개발 (Development of Image Guided 3D Localization Program for Stereotactic Brain Biopsy)

  • 이도희;이동준
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.197-201
    • /
    • 2004
  • 뇌 신경계에 발생한 비정상조직 등 병소들을 수술적 방법으로 생체 조직검사 시 방사선 영상 공간과 실제 물리적 공간을 3 차원적으로 일치시키고 국재(localization)하는 영상지원 뇌 정위 수술은 혹시 발생할지도 모르는 후유증을 최소화할 수 있다. 본 연구는 대부분 고가의 대형 정위 수술 프로그램에 포함되어 있는 뇌수술을 영상 지원하는 정위적 국재 프로그램들 중 임상에서 수술 빈도가 높은 생체조직 검사 시술 시에 최소한의 기능으로 수술을 지원할 수 있는 프로그램을 개발하고 팬텀을 이용해 국재 정확도를 측정한 후 임상에서 사용 가능성을 평가하였다. 프로그램은 영상자료 입력, fiducial marker 등록, 목표점 좌표 지정 및 좌표 값 표시 등 3 부분으로 구성하였고 팬텀을 이용한 프로그램의 정확도를 측정결과 임상에서 요구되는 일반적인 국재 정확도 한계인 2 mm 이내였다. 이 프로그램은 고난도의 뇌 정위 생검 수술시 정확한 시술이 가능하도록 지원하여 수술의 위험도를 줄이고 수술 성공률 향상에 기여할 수 있으리라 생각된다.

  • PDF

갑상샘 스캔 정량분석을 통한 갑상샘 섭취율 동시계측법 연구 (Study of Simultaneous Counting of Thyroid Uptake with Quantitative Analysis of Thyroid Scans)

  • 김정수;김근우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권5호
    • /
    • pp.401-408
    • /
    • 2023
  • Thyroid uptake measurements can be subject to measurement errors due to the scoping and positioning of the thyroid gland. To compensate for these limitations, the clinical utility of the thyroid simultaneous counting method as an alternative to thyroid uptake measurement was analyzed and evaluated experimentally through quantitative analysis of images acquired after thyroid scanning. Experimental data were obtained using a Gamma camera (GE infinia), a thyroid uptake system (KOROID 1), and a thyroid neck phantom. Based on the thyroid uptake rate of 1-5% according to the protocol of thyroid scan test (99mTcO4 - , 370 MBq) in normal results, 99mTcO4 - was set in the range of 3.7-18.5 MBq (Matrix: 256×256, Scan time: 1 min, collimator: pin hole, phantom-collimator distances: 7 cm). The acquired images were corrected for the attenuation of isotopes due to the set-up time and half-life by applying the Auto Region of interest (ROI) drawing system, and the significance of the experimental results was evaluated by Multiple linear regression analysis (SPSS, ver. 22, IBM). The thyroid uptake rate showed a significant correlation between the dose and the measured counts when using the thyroid uptake system equipment. Meanwhile, the quantitative analysis counts of phantom images using Gamma camera also showed a significant correlation. Thus confirmed that the correlation between these two experiments was statistically significant (P<0.05). The simultaneous counting protocol, which indirectly measures thyroid uptake from thyroid scans, is likely to be clinically relevant if complemented by additional studies with different variables in patients with thyroid disease.

선형가속기의 품질관리를 위한 2차원이온전리함배열의 유용성 (Feasibility of Two Dimensional Ion Chamber Array for a Linac Periodic Quality Assurance)

  • 이정우;홍세미;박병문;강민영;김유현;서태석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.183-188
    • /
    • 2008
  • 본 연구의 목적은 방사선치료용 선형가속기의 품질관리를 수행하기 위한 2차원이온전리함배열의 유용성을 검증하기 위함이다. 물팬톰과 필름으로 수행하던 기존의 품질관리 방법을 2차원이온전리함배열(MatriXX, Wellhofer Dosimetrie, Germany)을 이용하여 유용성을 검증하였다. MatriXX는 1,020개의 평판형 전리함(용적: $0.08\;cm^3$, 직경: 4.5mm, 높이: 5mm, 배열간격: 7.62mm)이 일정한 간격으로 $24{\times}24\;cm^2$의 면적에 배열 되어있다. MatriXX의 유용성을 검증하기 위해 연속된 5개월에 걸쳐 선량균등도, 에너지($TPR_{20,10}$), 그리고 절대 선량을 측정하여 물팬톰과 $0.65\;cm^3$ (FC65G, Wellhofer Dosimetrie, Germany) Farmer형 이온전리함을 통해 얻은 값과 비교, 분석하였다. MatriXX 측정 시 폴리스틸렌 고체 팬톰(${\rho}:\;1.18\;g/cm^3$)을 이용하였으며, MatriXX 고유의 커버 물질의 밀도와 두께(${\rho}:\;1.06\;g/cm^3$, t: 0.36 cm)를 물과 등가의 값으로 환산하여 적용하였다. 또한, 기하학적 점검을 위한 예비실험에서 콜리메이터의 회전축과 하프빔의 접합부를 필름측정의 결과와 비교하였다. 선량계측학적 실험 결과, MatriXX로 얻은 데이터와 물팬톰의 결과가 모든 항목에서 ${\pm}1%$ 이내의 일치를 보였다. 기하학 품질관리의 예비 실험 결과 기존의 필름방식과 유사한 결과를 얻었으며, 기하학적 품질관리의 정량적 분석 가능성을 제시하였다. 본 연구를 통해 주기적인 선형가속기의 품질관리에서 물팬톰과 필름을 대체할 수 있는 MatriXX의 유용성을 확인하였으며, 향후 비용절감과 시간과 인력을 절감할 수 있는 품질관리의 새로운 방법을 제시하였다.

  • PDF

전기 임피던스 단층촬영법에서 TSVD 기반의 역문제 해법의 개발 (Development of Inverse Solver based on TSVD in Electrical Impedance Tomography)

  • 김봉석;김창일;김경연
    • 전자공학회논문지
    • /
    • 제54권4호
    • /
    • pp.91-98
    • /
    • 2017
  • 전기 임피던스 단층촬영 기법은 도메인의 표면에 부착된 전극들을 통해 주입된 전류와 측정된 전압 데이터를 기반으로, 미지의 도전율 분포를 복원하는 비파괴 기술이다. 이 논문에서는 전기 임피던스 단층촬영법에서 일반적 Tikhonov 조정을 갖는 역문제를 풀고 도전율 분포를 복원하기 위해 절단된 특이값 분해 기반의 역문제 해법을 제안하였다. 역문제 계산시간을 줄이기 위해 일반 조정행렬을 역행렬 항목에서 분리시키고 절단된 특이값 분해 방법을 적용하였다. 제안한 방법의 성능을 검증하기 위해 모의실험과 팬텀실험을 수행하고 복원결과를 비교하였다.