• Title/Summary/Keyword: Matrix matched standard calibration curve

Search Result 6, Processing Time 0.018 seconds

The Study on Analytical Method of Lead, Cadmium and Chromium in Copper Metal by Matrix Matching Method of Inductively Coupled Plasma Atomic Emission Spectrometer (유도결합 플라즈마 발광분광기의 매트릭스 보정법에 의한 구리 중납, 카드뮴 및 크롬 분석에 관한 연구)

  • Joo, Sung-Kyun;Kim, Joon;cheong, Nam-Yong;Lim, Kyu-Chual;Choi, Young-Hwan;Kim, Sang-Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.3
    • /
    • pp.293-301
    • /
    • 2009
  • Analytical results of a fixed concentration of Pb, Cd and Cr in the synthetic copper standard solution (RMs) for using the matrix no matched standard calibration curve at various wavelength by ICP showed that accuracy (140 $\sim$ 1,070% in case of Pb) is very poor at all wavelengths because of the Cu matrix effect. Analytical results of a fixed concentration of Pb, Cd and Cr in the different concentration solutions of Cu showed that found values were on the increase or decrease as the rate of a regular equation as the concentration of Cu was increased. Accuracies by the Cu matching method in the analysis of Pb, Cd and Cr in the synthetic copper standard solution (RMs) were higher than 99.9%.

Evaluation of Matrix Effects in Quantifying Microbial Secondary Metabolites in Indoor Dust Using Ultraperformance Liquid Chromatographe-Tandem Mass Spectrometer

  • Jaderson, Mukhtar;Park, Ju-Hyeong
    • Safety and Health at Work
    • /
    • v.10 no.2
    • /
    • pp.196-204
    • /
    • 2019
  • Background: Liquid chromatography-tandem mass spectrometry (LC-MSMS) for simultaneous analysis of multiple microbial secondary metabolites (MSMs) is potentially subject to interference by matrix components. Methods: We examined potential matrix effects (MEs) in analyses of 31 MSMs using ultraperformance LC-MSMS. Twenty-one dust aliquots from three buildings (seven aliquots/building) were spiked with seven concentrations of each of the MSMs ($6.2pg/{\mu}l-900pg/{\mu}l$) and then extracted. Another set of 21 aliquots were first extracted and then, the extract was spiked with the same concentrations. We added deepoxy-deoxynivalenol (DOM) to all aliquots as a universal internal standard. Ten microliters of the extract was injected into the ultraperformance LC-MSMS. ME was calculated by subtracting the percentage of the response of analyte in spiked extract to that in neat standard from 100. Spiked extract results were used to create a matrix-matched calibration (MMC) curve for estimating MSM concentration in dust spiked before extraction. Results: Analysis of variance was used to examine effects of compound (MSM), building and concentration on response. MEs (range: 63.4%-99.97%) significantly differed by MSM (p < 0.01) and building (p < 0.05). Mean percent recoveries adjusted with DOM and the MMC method were 246.3% (SD = 226.0) and 86.3% (SD = 70.7), respectively. Conclusion: We found that dust MEs resulted in substantial underestimation in quantifying MSMs and that DOM was not an optimal universal internal standard for the adjustment but that the MMC method resulted in more accurate and precise recovery compared with DOM. More research on adjustment methods for dust MEs in the simultaneous analyses of multiple MSMs using LC-MSMS is warranted.

Development of a Simultaneous Analytical Method for Diquat, Paraquat and Chlormequat in Animal Products Using UPLC-MS/MS

  • Cho, Il Kyu;Rahman, Md. Musfiqur;Seol, Jae Ung;Noh, Hyun Ho;Jo, Hyeong-Wook;Moon, Joon-Kwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.4
    • /
    • pp.368-374
    • /
    • 2020
  • BACKGROUND: The residual analysis of polar pesticides has remained a challenge. It is even more difficult to simultaneously analyze multiple polar pesticides. Diquat, paraquat, and chlormequat are typical examples of highly polar pesticides. The existing methods for the analysis of diquat, paraquat and chlormequat are complex and time consuming. Therefore, a simple, quick and effective method was developed in the represent study for simultaneous analysis of diquat, paraquat and chlormequat in animal products, meat and fat using UPLC-MS/MS. METHODS AND RESULTS: Sample extraction was carried out using acidified acetonitrile and water and re- extracted with acidified acetonitrile and combine the extracts followed by centrifugation. The extract was then cleaned up with a HLB cartridge after reconstitution with acidic acetonitrile and water. The method was validated in quintuplicate at three different concentrations. The limits of detection (LOD) and quantification (LOQ) were 0.0015 and 0.005 mg/L, respectively. Matrix suppression effect was observed for all of the analytes. A seven point matrix matched calibration curve was constructed for each of the compound resulted excellent linearity with determination coefficients (R2) ≥ 0.991. Accuracy and precision of the method was calculated from the recovery and repeatability and ranged from 62.4 to 119.7% with relative standard deviation less than 18.8%. CONCLUSION: The recovery and repeatability of the developed method were in the acceptable range according to the Codex Alimentarius guideline. The developed method can be applied for the routine monitoring of diquat, paraquat, and chlormequat in animal products, meat and fat.

Development of LC-MS/MS analytical methods for metalaxyl in Atractylodes macrocephala Koidzumi and Achyranthes japonica Nakai (LC-MS/MS를 이용한 생약 백출 및 우슬 중 Metalaxyl 잔류분석법 개발)

  • Yun, Myung-Sub;Yang, Seung-Hyun;Choi, Hoon
    • Journal of Applied Biological Chemistry
    • /
    • v.65 no.1
    • /
    • pp.17-21
    • /
    • 2022
  • A new rapid and simple method for metalaxyl in Atractylodes macrocephala Koidzumi and Achyranthes japonica Nakai has been developed and validated. This study was conducted to develop a method for analyzing metalaxyl by a method based on QuEChERS using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Samples were extracted with acetonitrile and purified using amino-propyl (NH2) Solid Phase Extraction cartridge. The method limit of quantitation (MLOQ) was 0.01 mg/kg. The linearity of matrix-matched calibration curve (r2) was ≥0.99 at the calibration range of 0.001-0.05 mg/kg. For recovery test, Atractylodes macrocephala Koidzumi or Achyranthes japonica Nakai was treated with standard solutions at MLOQ and 10MLOQ levels. Recovery rates were in the range of 88.1-109.1% with <5.5% coefficient of variation. This established analytical method was fully validated. Based on these results, it can contribute to improving the safety of residual pesticides in Atractylodes macrocephala Koidzumi and Achyranthes japonica Nakai.

Monitoring of Pesticides in the Yeongsan and Seomjin River Basin (영산강 및 섬진강 수계 중 농약 분포 조사)

  • Lee, Young-Jun;Choi, Jeong-Heui;Kim, Sang Don;Jung, Hee-Jung;Lee, Hyung-Jin;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.274-281
    • /
    • 2015
  • BACKGROUND: A lasting release of low levels of persistence chemicals including pesticides and pharmaceuticals into river has a bad influence on aquatic ecosystems and humans. The present study monitored pesticide residues in the Yeongsan and Seomjin river basins and their tributaries as a fundamental study for water quality standard of pesticides.METHODS AND RESULTS: Nine pesticides(aldicarb, carbaryl, carbofuran, chlorpyrifos, 2,4-D, MCPA, methomyl, metolachlor, and molinate) were determined from water samples using SPE-Oasis HLB(pH 2) and LC/MS/MS. Validation of the method was conducted through matrix-matched internal calibration curve, method detection limit(MDL), limit of quantification(LOQ), accuracy, precision, and recovery. MDLs of all pesticides satisfied the GV/10 values. Linearity(r2) was 0.9965- 0.9999, and a percentage of accuracy, precision, and recovery was 89.4-113.6%, 3.1-14.0%, and 90.8-106.2%, respectively. All pesticides exclusive of aldicarb were determined in the river samples, and there was a connection between the positive monitoring results and agricultural use of the pesticides.CONCLUSION: Monitoring outcomes of the present study implied that pesticides were a possible non-point pollutant source in the Yeongsan and Seomjin river basins and tributaries. Therefore, it is required to produce and accumulate more monitoring results on pesticides in river waters to set water quality standards, finally to preserve aquatic ecosystems.

Development of Analytical Method for Kasugamycin in Agricultural Products using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 Kasugamycin 시험법 개발)

  • Lee, Han Sol;Do, Jung-Ah;Park, Ji-Su;Cho, Sung Min;Shin, Hye-Sun;Jang, Dong Eun;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.235-241
    • /
    • 2019
  • An analytical method was developed for the determination of an antibiotic fungicide, kasugamycin, in agricultural products (hulled rice, potato, soybean, mandarin and green pepper) using liquid chromatographytandem mass spectrometry (LC-MS/MS). Samples were extracted with methanol adjusted to pH 13 using 1 N sodium hydroxide, and purified with a HLB (hydrophilic lipophilic balance) cartridge. Linearity of a matrix-matched calibration curve using seven concentration levels, from 0.001 to 0.1 mg/kg, was excellent with a correlation coefficient ($R^2$) of more than 0.9998. The limits of detection (LOD) and quantification (LOQ) of instrument were 0.0005 and $0.001{\mu}g/mL$, respectively, and the LOQ of analytical method calculated as 0.01 mg/kg. The average recoveries at three spiking levels (LOQ, $LOQ{\times}10$, $LOQ{\times}50$, n=5) were in the range of 71.2~95.4% with relative standard deviation of less than 12.1%. The developed method was simple and all optimized results was satisfied with the criteria ranges requested in the Codex guidelines and Food Safety Evaluation Department guidelines. The present study could be served as a reference for the establishment of maximum residue limits (MRL) of kasugamycin and be used as basic data for safety management relative to kasugamycin residues in imported and domestic agricultural products.