• Title/Summary/Keyword: Material tester

Search Result 380, Processing Time 0.024 seconds

Recycling of Plant Fiber Resources: Enhanced Hydration of Newspaper Stock for Decrease of Deinking Reject (식물유래 섬유자원의 재활용: 탈묵 수율 개선을 위한 신문 지료의 수화 촉진 방안)

  • Chung, Sung-Hyun;Kim, Joong-Ho;Joo, Jong-Hun;Bang, Jae-Wook
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2011.10a
    • /
    • pp.39-41
    • /
    • 2011
  • The recycling rate of recovered paper in Korea is the highest in the world, 92%, but remanufacturing yield is low due to the extremely poor quality of the paper. The poor quality, in turn, influences to the reject amount in deinking process. To increase the yield of old newspaper recycling process, hydrophobic degree of inorganic pigments of deinking stock must be reduced. To determine the hydrophobicity, Pitch Potential Deposit Tester (PDT) was newly designed and applied with respect to the SB latex property of various quality used in Korea; its hydrophobic degree according to Tg, gel content, charge and particle size of latex and optimum designing condition of SB latex. And below are the conclusions: 1. The reason of excessive reject from old newspaper deinking process for total amount of printed ink is loss of inorganic pigments. When lipase, a biochemical catalyst, was applied with the purpose of preventing inorganic pigments loss about more than 70% of total reject weight and promoting hydration of pulp for deinking, deinking process yield of pre flotation secondary stage increased remarkably without any changes of deinking efficiency. 2. Lipase improved deinking stock by cutting ester linkage on surface of hydrophobic materials to promote its hydration. From this, it reached the conclusion that hydration degree of stock exercises significant effect on flotation deinking process yield. 3. Inorganic alkali promotes hydration of deinking stock. But there have been needs for more fundamental measures other than inorganic alkali of promoting hydration for yield improvement. For this, this study intended to find out reasons of chemical properties change on surface of hydrophobic material by change of pH. 4. Pitch Deposit Test (PDT) was performed for understanding principle of why surface of coating flake from OMG is hydrophobic and why it becomes hydrophilic when pH of stock is alkaline. As a result of this test, it is determined that swelling property by change of pH of latex film, which were used as coating adhesive is the reason for hydrophobic change. 5. Hydrophilicity of coating flake increased with hydrophilic pigments. And as more of SB Latex adhesive was used and higher of calcium hardness of stock became, its hydrophilicity decreased. SB Latex adhesive film is reformed by mechanical friction. For having hydrophilicity under neutral pH, strong bruising action such as kneading is required. 6. Because swelling of adhesive film decreases as Tg of SB latex gets lower and mean diameter gets smaller, it shows hydrophobicity under neutral pH. This lowers hydrophilicity of coating flake, which leads to easy elimination with flotation reject on DIP process. Therefore, for improving future flotation yield, it is necessary to develop to use eco-friendly clean SB latex by raising Tg and increasing mean diameter for recycling, and as a result, to reduce excessive loss of coating flake as a reject from deinking process.

  • PDF

THE EFFECTS OF BARIUM SULFATE AND IODIDE COMPOUND ON THE CHARACTERISTICS OF DENTAL ACRYLIC RESINS (치과용 아크릴릭 레진의 방사선 불투과도에 관한 연구 - 황산바륨과 요오드 화합물 첨가 -)

  • Lee Yong-Keun;Lee Keon-Il;Jung Sung-Woo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.133-145
    • /
    • 1996
  • Aspirating or swallowing foreign bodies is a common occurrence. If they are wholly or partly radiopaque, their localization in and progress through the gastrointestinal tract can be more effective. Of the dental origin foreign materials swallowed, the most common things are fragments of anterior maxillary partial denture. But the radiopacity of denture base resins is not sufficient to determine the location of the objects. The purpose of this study was to develop a radiopaque dental acrylic resin, which has clinically detectible radiopacity with minimal change of mechanical properties and color. The radiopacity, color change(CIE 6..E) and microhardness of acrylic resins were determined after mixing barium sulfate or iodide compound. Thermocycling course was conducted to determine the change of characteristic of resins after using for a long time in the mouth. Five or ten percent of barium sulfate to total weight of cured material was mixed with heat curing dental acrylic resin or chemically curing orthodontic resin. In the case of iodide compound, the mixing ratio was two or three percent. After mixing the high radiopaque materials, resin was cured to 20×20×2 mm plate, polished with #600 sand paper and finally polished with Microcloth(Buehler). The specimens were thermocycled in 5 and 55 t distilled water for 2,000 times, and the measurement of radiopacity, color and Vickers hardness was repeated every 500 times thcrmocycling. The radiopacity of specimens on the X -ray films was measured with densitometer(X-rite). The color change was detennined with differential colorimeter(Model TC-6FX, Tokyo Denshoku), and the Vickers hardness number was measured with microhardness tester(Mitsuzawa). The following results were obtained : 1. All the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, had combined effect on the radiopacity of the dental acrylic resins(p<0.0l). 2. The two variables, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of the dental acrylic resins(p<0.01). But the kinds of acrylic resins did not influence on the color change of mixed dental acrylic resins(p>0.05). 3. Each of the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of dental acrylic resins(p<0.0l). 4. The high radiopaque materials used in this study did not yield clinically usable radiopacity, and the color change was great after mixing those materials.

  • PDF

Friction and Wear Properties of Plasma-sprayed Cr2O3-MoO3 Composite Coatings at High Temperature (MoO3가 첨가된 Cr2O3 플라즈마 용사코팅의 고온 마찰 마멸 특성)

  • Lyo, In-Woong;Ahn, Hyo-Sok;Lim, Dae-Soon
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.9
    • /
    • pp.851-856
    • /
    • 2002
  • Tribological behavior of plasma-sprayed $Cr_2O_3$-based coatings containing $MoO_3$ at 450$^{\circ}C$ was investigated to understand the influence of $MoO_3$. A reciprocal disc-on-plate type tribo-tester was employed to examine fricition and wear behavior of the specimens. The microstructure and phase composition of the coating was characterized with Transmission Electron Microscopy(TEM). The TEM analysis indicated that $MoO_3$ was dispersed into the grain boundary, resulting in the increase of the hardness and density of the coating. Worn surfaces were investigated by scanning electron microscopy and chemistry of the worn surfaces was analyzed using a X-ray Photoelectron Spectrometer(XPS). The results showed that the friction coefficient of the $MoO_3$-added coatings was lower than that without $MoO_3$ addition. The larger protecting layers were observed at the worn surface of plasma spray coated specimens with $MoO_3$ composition in the protecting layer appears to be more favorable in reducing the friction.

Preparation and Dissolution Properties of Oral Controlled Release Formulation Containing Carvedilol (카르베딜롤을 함유하는 경구제어 방출형 제제의 제조 및 용출특성)

  • Choi, Won-Sik;Kim, Yong-Nam;Nam, Seok-Woo;Yang, Jin-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2451-2458
    • /
    • 2010
  • We prepared sustained release matrix system which contains carvedilol with Compritol 888 ATO used as lipophilic sustained release excipient and hydroxypropyl methyl cellulose (HPMC) or polyethylene oxide (PEO) used as hydrophilic sustained release polymer. Wet granulation compressed method was used for preparing carvedilol sustained release matrix tablets. When carvedilol sustained release matrix tablets were prepared, we evaluated the drug release kinetics which is affected by Compritol 888 ATO ratio, a kind of hydrophilic polymer (HPMC, PEO) and hot melt coating coagglutination (HMCC) process was done. The drug release kinetics was measured for 24 hours in pH 1.2 simulated gastric fluid and pH 6.8 simulated intestinal fluid, using a dissolution tester at $37.5^{\circ}C$ in 50 rpm. Dissolution rate of controlled release matrix tablets of carvedilol was evaluated by paddle method. We confirmed that HMCC process was very effective to controlled release of drugs. The rate of Compritol 888 ATO, as a lipidic material, can control the drug release pattern about the elution rate of 95% and 24 hours delay than that of the normal tablet.

Bone-Preserving Decompression Procedures Have a Minor Effect on the Flexibility of the Lumbar Spine

  • Costa, Francesco;Ottardi, Claudia;Volkheimer, David;Ortolina, Alessandro;Bassani, Tito;Wilke, Hans-Joachim;Galbusera, Fabio
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.6
    • /
    • pp.680-688
    • /
    • 2018
  • Objective : To mitigate the risk of iatrogenic instability, new posterior decompression techniques able to preserve musculoskeletal structures have been introduced but never extensively investigated from a biomechanical point of view. This study was aimed to investigate the impact on spinal flexibility caused by a unilateral laminotomy for bilateral decompression, in comparison to the intact condition and a laminectomy with preservation of a bony bridge at the vertebral arch. Secondary aims were to investigate the biomechanical effects of two-level decompression and the quantification of the restoration of stability after posterior fixation. Methods : A universal spine tester was used to measure the flexibility of six L2-L5 human spine specimens in intact conditions and after decompression and fixation surgeries. An incremental damage protocol was applied : 1) unilateral laminotomy for bilateral decompression at L3-L4; 2) on three specimens, the unilateral laminotomy was extended to L4-L5; 3) laminectomy with preservation of a bony bridge at the vertebral arch (at L3-L4 in the first three specimens and at L4-L5 in the rest); and 4) pedicle screw fixation at the involved levels. Results : Unilateral laminotomy for bilateral decompression had a minor influence on the lumbar flexibility. In flexion-extension, the median range of motion increased by 8%. The bone-preserving laminectomy did not cause major changes in spinal flexibility. Two-level decompression approximately induced a twofold destabilization compared to the single-level treatment, with greater effect on the lower level. Posterior fixation reduced the flexibility to values lower than in the intact conditions in all cases. Conclusion : In vitro testing of human lumbar specimens revealed that unilateral laminotomy for bilateral decompression and bone-preserving laminectomy induced a minor destabilization at the operated level. In absence of other pathological factors (e.g., clinical instability, spondylolisthesis), both techniques appear to be safe from a biomechanical point of view.

Resistive E-band Textile Strain Sensor Signal Processing and Analysis Using Programming Noise Filtering Methods (프로그래밍 노이즈 필터링 방법에 의한 저항 방식 E-밴드 텍스타일 스트레인 센서 신호해석)

  • Kim, Seung-Jeon;Kim, Sang-Un;Kim, Joo-yong
    • Science of Emotion and Sensibility
    • /
    • v.25 no.1
    • /
    • pp.67-78
    • /
    • 2022
  • Interest in bio-signal monitoring of wearable devices is increasing significantly as the next generation needs to develop new devices to dominate the global market of the information and communication technology industry. Accordingly, this research developed a resistive textile strain sensor through a wetting process in a single-wall carbon nanotube dispersion solution using an E-Band with low hysteresis. To measure the resistance signal in the E-Band to which electrical conductivity is applied, a universal material tester, an Arduino, and LCR meters that are microcontroller units were used to measure the resistance change according to the tensile change. To effectively handle various noises generated due to the characteristics of the fabric textile strain sensor, the filter performance of the sensor was evaluated using the moving average filter, Savitsky-Golay filter, and intermediate filters of signal processing. As a result, the reliability of the filtering result of the moving average filter was at least 89.82% with a maximum of 97.87%, and moving average filtering was suitable as the noise filtering method of the textile strain sensor.

The Discoloration Characteristics of Orpiment used as Traditional Yellow Mineral Pigments in Painting Cultural Properties (채색문화재에 적용된 전통 황색 광물안료 석황의 채색 특성)

  • Jin Young Do
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.36 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • On painting cultural properties to which Orpiment, a traditional yellow mineral pigment, is applied, the color's degeneration is frequently observed. To identify the cause of the degeneration, this study takes a look into orpiment and the various pigments that are mixed into it (Lead White, Lead Red, and Cinnabar) in powder and painting state. The pigment was mixed with Argyo glue and then applied to korean traditional paper and silk. Considering the possibility that alum causes the discoloration, it was applied to the specimen. With a UV tester, the powders and the painted specimens were subjected to a light resistance test in three phases (96 hour). Color changes were measured with a colorimeter and minerals, chemical composition and structural changes were analysed by XRD, SEM/EDS and Raman spectrometers. While the color change of pure Orpiment powder according to the light resistance test was small, the colored specimen became darker. The color change was large in the Orpiment colored on the silk and in the alum-treated specimen. In Orpiment powder was produced white arsenolite as altered orpiment after UV test. In the mixed powder of Orpiment and Lead White were detected only the constituent minerals of Orpiment and Lead White, and no altered substances were produced. Whereas after the UV test, orpiment and arsenolite, which were altered substances of orpiment, and the constituent minerals of Lead White were detected. In the case of mixing the two pigments in the powder state, darkening did not occur even by the UV test. However, the specimens colored with the mixed powder were darkened by the UV test. The color change of Orpiment was different depending on the mixed pigment and base material. The color change was greater in the case of alum treatment than in the case without alum treatment, and it was found that alum also had an influence on the color change of Orpiment.

Microtensile bond strength of resin inlay bonded to dentin treated with various temporary filling materials (임시 가봉재가 상아질과 레진 인레이의 미세인장 결합 강도에 미치는 영향)

  • Kim, Tae-Woo;Lee, Bin-Na;Choi, Young-Jung;Yang, So-Young;Chang, Hoon-Sang;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.419-424
    • /
    • 2011
  • Objectives: This study was aimed to determine the effects of temporary sealing materials on microtensile bond strength between resin-coated dentin and resin inlay and to compare the bonding effectiveness of delayed dentin sealing and that of immediate dentin sealing. Materials and Methods: The teeth were divided into 4 groups: group 1, specimens were prepared using delayed dentin sealing after temporary sealing with zinc oxide eugenol (ZOE); group 2, specimens were prepared using immediate dentin sealing and ZOE sealing; group 3, specimens were prepared using immediate dentin sealing and Dycal (Dentsply) sealing; group 4, specimens were prepared using immediately sealed, and then temporarily sealed with a resin-based temporary sealing material. After removing the temporary sealing material, we applied resin adhesive and light-cured. Then the resin inlays were applied and bonded to the cavity with a resin-based cement. The microtensile bond strength of the sectioned specimens were measured with a micro-tensile tester (Bisco Inc.). Significance between the specimen groups were tested by means of one-way ANOVA and multiple Duncan's test. Results: Group 1 showed the lowest bond strength, and group 4 showed the highest bond strength (p < 0.01). When temporary sealing was performed with ZOE, immediate dentin sealing showed a higher bonding strength than delayed dentin sealing (p < 0.01). Conclusions: Based on these results, immediate dentin sealing is more recommended than delayed dentin sealing in bonding a resin inlay to dentin. Also, resin-based temporary sealing materials have shown the best result.

SURFACE HARDNESS OF THE DENTAL COMPOSITE CURED BY LIGHT THAT PENETRATE TOOTH STRUCTURE ACCORDING TO THICKNESS OF TOOTH STRUCTURE, LIGHT INTENSITY AND CURING TIME (치질을 투과한 조사광에 의한 복합레진 중합시 치질의 두께, 광세기 및 조사 시간이 복합레진의 표면 경도에 미치는 영향)

  • Cho, Soo-Kyung;Kim, Dong-Jun;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.128-137
    • /
    • 2005
  • In this study we measured the amount of light energy that was projected through the tooth material and analyzed the degree of polymerization by measuring the surface hardness of composites. For polymerization, Optilux 501 (Demetron, USA) with two types of light guide was used: a 12 mm diameter light guide with 840 nW/$cm^2$ light intensity and a 7 mm diameter turbo light guide with 1100 nW/$cm^2$. Specimens were divided into three groups according to thickness of penetrating tooth (1 mm, 2 mm, 0 mm). Each group was further divided into four subgroups according to type of light guide and curing time (20 seconds, 40 seconds). Vickers' hardness was measured by using a microhardness tester. In 0 mm and 1 mm penetrating tooth group, which were polymerized by a turbo light guide for 40 seconds, showed the highest hardness values. The specimens from 2 mm penetrating tooth group, which were polymerized for 20 seconds, demonstrated the lowest hardness regardless of the types of light guides (p < 0.05). The results of this study suggest that, when projecting tooth material over a specified thickness, the increase of polymerization will be limited even if light intensity or curing time is increased.

Polymerization of dual cured composites by different thickness (두께에 따른 이중 중합형 복합레진의 중합)

  • Kim, Yun-Ju;Jin, Myoung-Uk;Kim, Sung-Kyo;Kwon, Tae-Yub;Kim, Young-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.169-176
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of thickness, filling methods and curing methods on the polymerization of dual cured core materials by means of microhardness test. Two dual cured core materials, MultiCore Flow (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Bis-Core (Bisco Inc., Schaumburg, IL, USA) were used in this study. 2 mm (bulky filled), 4 mm (bulky filled), 6 mm (bulky and incrementally filled) and 8 mm (bulky and incrementally filled)-thickness specimens were prepared with light cure or self cure mode. After storage at $37{\circ}C$ for 24 hours, the Knoop hardness values (KHN) of top and bottom surfaces were measured and the microhardness ratio of top and bottom surfaces was calculated. The data were analyzed using one-way ANOVA and Scheffe multiple comparison test, with ${\alpha}$= 0.05. The effect of thickness on the polymerization of dual cured composites showed material specific results. In 2, 4 and 6 mm groups, the KHN of two materials were not affected by thickness. However, in 8 mm group of MultiCore Flow, the KHN of the bottom surface was lower than those of other groups (p < 0.05). The effect of filling methods on the polymerization of dual cured composites was different by their thickness or materials. In 6 mm thickness, there was no significant difference between bulk and incremental filling groups. In 8 mm thickness, Bis-Core showed no significant difference between groups. However, in MultiCore Flow, the microhardness ratio of bulk filling group was lower than that of incremental filling group (p < 0.05). The effect of curing methods on the polymerization of dual cured composites showed material specific results. In Bis-Core, the KHN of dual cured group were higher than those of self cured group at both surfaces (p < 0.05). However, in MultiCore Flow, the results were not similar at both surfaces. At the top surface, dual cured group showed higher KHN than that of self cured group (p < 0.05). However, in the bottom surface, dual cured group showed lower value than that of self cured group (p < 0.05).