• Title/Summary/Keyword: Material and Contamination

Search Result 450, Processing Time 0.024 seconds

A Leakage Current Analysis of EHV Porcelain Insulators by Artificial Contamination Method (초고압 송전용 자기애자의 인공오손법을 통한 누설전류 분석)

  • Choi, In-Hyuk;Choi, Jang-Hyun;Jung, Yoon-Hwan;Lee, Dong-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.65-68
    • /
    • 2004
  • This paper researched leakage current characteristics of artificially contaminated EHV insulators through construction of long-term testing facility. Insulators were contaminated and classified into the ESDD contaminated levels under IEC standards method. As the test results of contaminated insulators was carried out several experiments, leakage current greatly increased during initial rainfall. After contaminated insulators were naturally washed by rain, leakage current was not increased.

  • PDF

Performance Evaluation of Fine-Dust Blocking Effect of Functional Clothing (미세먼지 차단 기능성 의류 제품의 성능 평가에 관한 연구)

  • Seok-Ju, Hwang;Chang-Hoon, Lee;Jin-Kyung, Kwon;Young-Sil, Kim;Eun-Jin, Choi;Da-Jin, Kim;Min, Kim;Se-Jin, Yook
    • Particle and aerosol research
    • /
    • v.18 no.4
    • /
    • pp.137-145
    • /
    • 2022
  • As many studies on the harmfulness of fine dust have been reported, awareness of its seriousness is spreading. Recently, interest in indoor air quality as well as air pollution is increasing, and research on measures to block fine dust flowing into the room from the outside is being conducted. The clothing company is launching functional clothing to prevent fine dust attached to clothing from entering the room through outdoor activities. However, it is difficult to confirm whether there is actually fine-dust blocking performance, and there is no evaluation standard. In this study, the contamination rate caused by fine dust was quantitatively compared through image processing after contamination of the outer fabric for 4 types of commercially available functional clothing with fine-dust blocking effect. The difference in particle contamination according to the material of the outer fabric was analyzed by comparing the surface resistance, and it was found that the higher the surface resistance of the outer fabric material, the more fine dust was attached. The analysis method of this study is expected to be able to quantitatively compare and evaluate the fine-dust blocking performance of functional clothing.

TENSILE STRENGTHS OF PRE-LIGATURED BUTTON WITH SEVERAL TYPES OF CONTAMINATION IN DIRECT BONDING PROCEDURE WHICH CAN HAPPEN DURING THE SURGICAL EXPOSURE OF UNERUPTED TEETH (치아의 견인을 위한 버튼 접착시 오염이 인장강동에 미치는 영향)

  • Kim, Seong-Oh;Choi, Byung-Jai;Lee, Jae-Ho;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.400-420
    • /
    • 1998
  • We already know that it is very difficult to obtain an "isolated field" for direct bonding during the surgical exposure of unerupted teeth. The aim of this in-vitro study is to simulate the clinical situation of forced eruption and to evaluate the tensile strengths of preligatured button with several types of contamination which can happen during the surgical exposure of unerupted teeth. Four orthodontic direct bonding systems were used. ($Ortho-One^{TM}$, $Rely-a-Bond^{(R)}$, $Ortho-Two^{TM}$, Phase $II^{(R)}$) Each material was divided into four groups(n=20) : Group 1. (Control, no contamination), Group 2. (Rinse etching agent with saline instead of water), Group 3. (Blood contamination of etched surface for 30 seconds), Group 4. (Blood contamination of primed surface for 30 seconds) 320 bovine anterior permanent teeth were divided into the above mentioned 16 groups. Enamel surface was flattened and ground under water coolant. Pre-ligatured buttons were prepared to the same form. (Cut 0.25 ligature wire 10 cm in length. Twist the ligature wire 30 times clockwise. Mark the wire 15mm and 35mm points from button. Make a loop sticking two points together and twist the loop 6 times counterclockwise.) The bonded specimens were stored at $37^{\circ}C$ saline solution for 3 days. Then the tensile strength of each sample was measured with Instron universal testing machine, crosshead speed of 0.5mm/min. The following results were obtained: 1. As compared to control groups (Group 1) of each material, Rely-a-Bond had a significantly lower mean tensile strengths than other material. (p<0.01) 2. In Group 2. of Ortho-One and Rely-a-Bond, the mean tensile strengths decreased about 7.7% and 11.1%, respectively with statistical significances. (p<0.05) 3. In Group 2. of Ortho-Two and Phase II, the mean tensile strengths did not decrease. 4. In Group 3. of Ortho-One, Rely-a-Bond, Ortho-Two, and Phase II, the mean tensile strengths decreased about 60.8%, 56.1%, 60.2%, and 46.0%, respectively with statistical significances. (p<0.01) 5. In Group 4. of Ortho-One and Rely-a-Bond, the mean tensile strengths did not decrease. 6. In Group 4. of Ortho-Two and Phase II, the mean tensile strengths were decreased about 20.95% and 22.28%, respectively with statistical significances. (p<0.01) There were formations of a hump shaped mass from bonding resin under blood contamination which disturbed direct bonding procedure. According to Reynolds, the proper bond strength for clinical manipulation should be at least 45N or about 4.5Kg.F. According to these results, it can be concluded that Ortho-One could be used during surgical exposure of unerupted teeth. In any case, blood contamination of the etched surface should be avoided, but the blood contamination of primed surface of Ortho-One may not decrease bond strength. Just 'blowing-out' is enough to remove blood from primed surface of Ortho-One. You can verify the clean surface of the primer of Ortho-One after blowing out the blood contamination.

  • PDF

Strong Red Photoluminescence from Nano-porous Silicon Formed on Fe-Contaminated Silicon Substrate

  • Kim, Dong-Lyeul;Lee, Dong-Yul;Bae, In-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.5
    • /
    • pp.194-198
    • /
    • 2004
  • The influences of the deep-level concentration of p-type Si substrates on the optical properties of nano-porous silicon (PS) are investigated by deep level transient spectroscopy (DLTS) and photoluminescence (PL). Utilizing a Si substrate with Fe contaminations significantly enhanced the PL intensity of PS. All the PS samples formed on Fe-contaminated silicon substrates had stronger PL yield than that of reference PS without any intentional Fe contamination but the emission peak is not significantly changed. For the PS 1000 sample with Fe contamination of 1,000 ppb, the maximum PL intensity showed about ten times stronger PL than that of the reference PS sample. From PL and DLTS results, the PL efficiency strongly depends on the Fe-related trap concentration in Si substrates.

Development and Characteristics Evaluation of Polymer Housing Type Arresrter (폴리머 housing형 피뢰기의 개발과 특성 평가)

  • 조한구;김인성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.82-85
    • /
    • 1997
  • This paper describes the development of new type arrester for 22.9kV class distribution lines, with polymer insulating materials applied to their housings. The new arrester employs silicone insulating material for its housing, instead of the conventional porcelain housing, aiming at reduction in size and weight and explosion proof against internal short circuit failure. And, since the design of sheds is not restricted. it is possible to provide a long surface leakage distance per strike length and improve anti-contamination performance.

  • PDF

A Fundamental Study on the Contaminants Using in Place of the Soapy Water for Floor Slip Resistance Test (바닥의 미끄럼시험에 사용되는 비눗물 대체 물질에 관한 기초적 연구)

  • Kim, Dae-Kyu;Shin, Yun-Ho;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.156-157
    • /
    • 2015
  • The safety concern of slipping on floors in South Korea has come to the fore as a social problem, but the occurrence of such accidents has not decreased. Slip and fall accidents have several causes, but they are especially common when there is soapy water on the floor during a shower or a bath. Despite this situation, it can be said that there is a lack of standards on surface contamination materials used in floor slip resistance testing. Therefore, in this study, we conducted a survey to identify the components and quantity of soapy water that actually results from a user taking a shower, and the standardization of contamination materials. Based on the results of this experiment, we provide a surface contamination material that can replace the soapy water used in floor slip resistance testing.

  • PDF

Recommendable Methods for Effective Improvement of Management System on Organic Materials based on the Analysis of Unintentional Contamination Investigation and Recognition Survey collected from Organic Farmer and so on (유기농업자재중 비의도적 오염원 조사분석 및 친환경농업인 등 인식조사에 근거한 유기농업자재 관리제도의 효율적 개선방안)

  • Ahn, In;Lee, In-Ae;Sim, Mi-Jin
    • Korean Journal of Organic Agriculture
    • /
    • v.23 no.4
    • /
    • pp.659-682
    • /
    • 2015
  • This study was conducted to suggest ideal management system for organic materials. As the performing method of the study, surveyed results on understanding of related persons (organic farmer 846, organic materials manufacture 70 and Organic materials Auditors 7) with eco-friendly farming were used. And the opinion on unintentional pollution source contained in organic materials was surveyed additionally. The issues pointed out by organic farmers on product of organic materials were high price (60% to total), poor efficacy (16%), disorder on distribution system (13%) and containing chemicals as a pesticide (10%). And notification system for organic materials was accepted in general (positive and so so 76%) while most interviewees preferred (89%) unification of certification system dominantly. As unintentional contamination source, pollution on imported row material was indicated as major reason, and other causes were confirmed as insertion during manufacturing process, agricultural by-products using as product additive et al. Based on these surveyed results, authors suggest bellows as considerable methods for effective improvement of management system on organic material. First, establish new integrated certification system which contains standard of quality certification and notification system on organic material. Second, for evaluation of efficacy, apply relative evaluation system of significance such as Duncan's multiple test instead of existing absolute evaluation system. Third, constitute and operate selection of standard comparison subcommittee in organic Agro-materials committee in RDA.

Bacterial Contamination and Its Effects on Ethanol Fermentation

  • Chang, In-Seop;Kim, Byung-Hong;Shin, Pyong-Kyun;Lee, Wan-Kyu
    • Journal of Microbiology and Biotechnology
    • /
    • v.5 no.6
    • /
    • pp.309-314
    • /
    • 1995
  • Samples were collected from a commercial ethanol production plant to enumerate the bacterial contamination in each step of a starch based ethanol production process. Though the slurry of raw material used in the process carried bacteria with various colony morphology in the order of $10^4$ per ml, only the colonies of white and circular form survived and propagated through the processes to the order of $10^8$ per ml at the end of fermentation. Almost all of the bacterial isolates from the fermentation broth were lactic acid bacteria. Heterofermentative Lactobacillus fermentum and L. salivarius, and a facultatively heterofermentative L. casei were major bacteria of an ethanol fermentation. In a batch fermentation L. fermentum was more detrimental than L. casei to ethanol fermentation. In a cell-recycled fermentation, ethanol productivity of 5.72 g $I^{-1} h^{-1}$ was obtained when the culture was contaminated by L. fermentum, whilst that of the pure culture was 9.00 g $1^{-1} h^{-1}$. Similar effects were observed in a cell-recycled ethanol fermentation inoculated by fermentation broth collected from an industrial plant, which showed a bacterial contamination at the level of 10$^8$ cells per ml.

  • PDF

PLC Optical Sensor for Contamination Monitoring on the Flow-Cell in the Water Quality Measurement System (수질 측정용 플로우 셀의 오염 모니터링을 위한 평면광도파로 센서)

  • Han, Seung Heon;Kim, Tae Un;Jung, Haeng Yun;Ki, Hyun Chul;Kim, Doo Gun;Kim, Seon Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.6
    • /
    • pp.472-476
    • /
    • 2019
  • We have proposed a novel planar lightwave circuit (PLC) optical sensor to monitor the contamination in a flow-cell where water is continuously supplied through a water quality measurement system. We designed a PLC chip with a V-shape waveguide and the simulated its function as a sensor for monitoring contamination in a flow-cell using a numerical the FDTD (finite-difference time-domain) analysis. A novel cross type of waveguide was introduced to make the PLC chip of the V-shaped waveguide. The fabricated PLC was cut into the cross waveguide. A change in the optical propagation loss of the PLC sensor was observed after immersing the PLC sensor into city water. It was determined that the propagation loss of the PLC sensor was 3 dB at a wavelength of $1.55{\mu}m$ in the city water for 15 days.