• Title/Summary/Keyword: Material Safety A Sheet

Search Result 78, Processing Time 0.026 seconds

Risk Assessment of Micro and Emerging Contaminants in Domestic Effluent Environment: Targeting on 80 First-class substances assigned by Ministry of Environment (미량 및 신종유해물질의 국내 방류 환경에서의 위해성 평가: 환경부 지정 1순위 80종 대상으로)

  • Lee, Jai-Yeop;Park, Saerom;Kim, Ilho
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.6
    • /
    • pp.501-509
    • /
    • 2021
  • In 2018, total 263 micro and emerging contaminants were selected as target substances by the Ministry of Environment, and 80 of them were first-class substance including endocrine disruptors, residual Pharmaceuticals and Personal Care Products (PPCPs), residual organic pollutants, pesticides and heavy metals. In this study, in order to evaluate the Hazard Quotient (HQ) of the 80 types in the domestic water environment the concentration of discharged effluent and nearby water environment reported by Korean institutes since 2010 was investigated. There were 45 substances reported to be detected, and Measurement Environment Concentration (MEC) were obtained by collectively converting them into water environment concentration. For biotoxicity, half maximal Effective Dose (EC50) to Daphnia magna, a water fleas species widely adopted in Material Safety Data Sheet (MSDS) was applied. As for the biotoxicity level, the Predicted No-Effect Concentration (PNEC) was obtained by applying the Assessment Factor (AF) and the HQ was derived by dividing it from the MEC. As a result of calculating the HQ, more than 1 substances were Cabamazepine, Mefenamic acid, Acetaminophen, Ibuprofen, Nonylphenol, Nickel, Erythromycin, Acetylslic acid, etc. Meanwhile, perfluorinated compounds were identified as hazardous substances in the water env ironment, with 5 out of 14 species included in the 20 ranks of first-class substance.

Development of Element Technique for the Floating PV Generation Structure Using FRP (FRP를 활용한 수상 부유식 태양광발전 구조물의 요소기술 개발)

  • Seo, Su-Hong;Choi, Jin-Woo;Joo, Hyung-Joong;Nam, Jeong-Hun;Yoon, Soon-Jong
    • Composites Research
    • /
    • v.27 no.3
    • /
    • pp.103-108
    • /
    • 2014
  • Fiber reinforced polymer plastic (FRP) structural members are recently available in construction industries due to various material properties such as high specific strength and stiffness, light-weight, and corrosionresistance. The floating PV generation structure can also be an illustration for applying FRP in construction applications. The floating PV generation structure has been recently issued as a representative item for the low carbon and green growth campaign and many related studies have been conducted for the structural safety and commercial viability. Moreover, the floating PV generation structures for the commercial purpose have been constructed. In this paper, the investigation and development processes of elements for the floating PV generation structure are presented during commercialization.

A Study on the Flammability and Combustion Risk of Biodiesel Mixture (바이오디젤 혼합물의 인화 및 연소 위험성에 관한 연구)

  • Kim, Ju Suk;Ko, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.10-24
    • /
    • 2021
  • Purpose: The purpose of this study is to determine the dangers of biodiesel and general diesel mixtures currently used as alternative fuels by equipment (tag method and penski Marten method) and to determine the difference between flash point and combustion point (closed, open) according to test methods. It is intended to be used as a reference material for identification and evaluation of firecausing substances by confirming the risk of mixtures by comparative analysis and measurement, and establishing a risk assessment method for chemical substances. Method: Flash point test method and result treatment were tested based on ASTM and KS M mode, which are tag sealing and pen schematense test methods used as flash point and combustion point test methods for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was a test equipment that satisfies the test standards of KS M 2010 with equipment produced by TANAKA of Japan. The flash point and combustion point were measured, and the flash point according to the test method of biodiesel and general diesel mixture ( Closed, open), and the ignition point of a mixture of biodiesel and general diesel was compared and analyzed for ignition risk compared with conventional diesel. Results: Looking at the experimental results, first, as an analysis of the risk of flammability of the mixture, the flash point of a substance containing 70% biodiesel was found to be about 92℃ based on general diesel with a flash point of 64.5℃, and gasoline and biodiesel or When the biodiesel mixture was synthesized, it was confirmed that the flash point tends to decrease. In addition, the difference between the flash point and the combustion point was analyzed as about 20 ~ 30℃, and when a small amount of gasoline or methanol was mixed, the flash point was lowered, but it was confirmed that the combustion point was similar to that of the existing mixture. Conclusion: In this study, in order to secure the effectiveness of the details of the criteria for judging dangerous materials in the existing Dangerous Materials Safety Management Act, and to secure the reliability and reproducibility of the judgment of dangerous materials, we confirm the criteria for judging the risk of the mixture through an experimental study on flammable mixtures. It will be able to provide reference data for experimental criteria for flammable liquids that are regulated in the field. In addition, if this study accumulates know-how on experiment by test method, it is expected that it can be used as a basis for research on risk assessment and research on dangerous goods.

The formability of high strength steel plate applied TRB for stamping (스탬핑용 고강도강 TRB 판재의 성형 특성)

  • Park, Hyun-kyung;Jeong, Ji-Won;Lee, Gyung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.184-189
    • /
    • 2018
  • Recently, research on lightweight automobiles is increasing continuously to respond to the high safety standards and environmental regulations. The application of high strength steel is one of the effective methods for developing lightweight car bodies. A TWB (Tailor Welded Blank) is major method that allows partial high strength with light weighting using a multi-thickness and multi-material welded blank. On the other hand, additional welding process is required to prepare the blank and quality control for the welding process also required. To secure this point, the TRB (Tailor Rolled Blank) method was suggested. In the TRB method, the thickness of sheet is controlled by the rolling presses and the production efficiency is much higher than welding in TWB methods. In this study, the formability of high strength TRB steel plate was analyzed to examine the rolling effect of the blank. The formability of the specimen was tested using 0.8 and 1 mm thick steel sheets for the TRB plate. The strain was analyzed by the digital image sensing of grid markings on the specimen and the forming limit diagram was calculated. An Erichsen test for the 0.8 and 1 mm thick TRB specimens was carried out and the formability was investigated by comparing with FE analysis.

Structural Performance Evaluation of Floating PV Power Generation Structure System (수상 부유식 태양광발전 구조물의 구조적 성능 평가)

  • Choi, Jin Woo;Seo, Su Hong;Joo, Hyung Joong;Yoon, Soon Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1353-1362
    • /
    • 2014
  • In recent years, numerous environmental problems associated with the excessive use of fossil fuel are taking place. For an alternative energy resource, the importance of renewable energy and the demands of facilities to generate renewable energy are continuously rising. To satisfy such demands, a large number of photovoltaic energy generation structures are constructed and planned with large scale. However, because these facility zones are mostly constructed on land, some troubles are occurred such as rising of construction cost due to the cost of land use, environmental devastation, etc. To solve such problems, the floating type photovoltaic energy generation system using FRP members have been developed in Korea. FRP members are recently available in civil engineering applications due to many advantages such as high strength, corrosion resistance, light weight, etc. and they are suitable to fabricate the floating structures because of their material properties. In this study, the analytical and experimental investigations to evaluate the structural performance of floating PV generation structure and SMC FRP vertical member which is used to fabricate the structure were conducted. The static and dynamic performances of floating PV generation structure are evaluated through the FE analysis and the experiment, respectively. Moreover, the structural safety evaluation and buckling analysis of SMC FRP vertical compression member are also conducted by the FE analysis, and the structural behavior of SMC FRP member under compression and pullout is investigated by the experiments. From this study, it was found that the structural system composed of pultruded FRP and SMC FRP members are safe enough to resist externally applied loads.

Current State of Occupational Health in Small-Scale-Enterprises of Korea (50인 미만 소규모사업장의 보건관리 실태)

  • Yun, Soon-Nyung;Kim, Young-Im;Jung, Hye-Sun;Kim, Soon-Lae;Yoo, Kyung-Hae;Song, Young-Sook;Kim, Hwa-Joong
    • Research in Community and Public Health Nursing
    • /
    • v.11 no.1
    • /
    • pp.90-104
    • /
    • 2000
  • This study was carried out to investigate the current state of occupational health management and characteristics of employees working in small-scale-enterprises (SSE) employing less than 50 workers. Samples were chosen among the two thousands employees working in 838 factories where located in Youngdungpo-Ku, Seoul, Korea. The study results were as followed: 1. Most factories investigated in the study were manufactures (68.6%) which were established in 5 to 10 years ago (29.2%), employing less than 5 workers (72.9%) and registered in accident compensation insurance (23.0%). 2. Health screening was undertaken in 24.9% workplaces for periodic health examination and in 1.5% for special health examination. Environmental monitoring was done in 3.3% factories. Very few factories displayed Material Substance Data Sheet (MSDS) in 3.1% among the total factories. 3. Workplaces usually had their own toilets in 75.9% and washing basin in 58.6% as types of sociowelfare facilities. 4. Employees responded in the study were mostly in the range of age from 30 to 39 in 34.7%. male in 84.8%. the married in 70.3%. manual workers in 42.0%. mostly working regularly 51 hours per a week in 48.2% and earned 710.000 Won to 1.000.000 Won per month in 35.0%. Medical utilization for employees were covered by factories sponsored medical insurance in 12.7% and by provincial sponsored medical insurance in 83.4%. 5. Two point six percents of employees were suffered by diseases. The health complaints indicated were mainly digestive problems in 46.7% and hypertension in 24.4%. 6. Employees wore personal protective equipments for work such as gloves in 48.1%. safety shoes in 30.5%. ear plug in 5.5% and mask in 6.9%. Based on the results of study, we recommend that various types of occupational health management should be developed according to workplace working condition of each factory. In addition to the development of occupational health strategies. we think that it is more important to monitor and to allocate how effectively they operate each other on the basis of longitudinal continuity. Besides, we would like to insist that these all management effort should be focused on prevention of disease and occupational health education of employees.

  • PDF

Determination of Cost and Measurement of nursing Care Hours for Hospice Patients Hospitalized in one University Hospital (일 대학병원 호스피스 병동 입원 환자의 간호활동시간 측정과 원가산정)

  • Kim, Kyeong-Uoon
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.6 no.3
    • /
    • pp.389-404
    • /
    • 2000
  • This study was designed to determine the cost and measurement of nursing care hours for hospice patients hostpitalized in one university hospital. 314 inpatients in the hospice unit 11 nursing manpower were enrolled. Study was taken place in C University Hospital from 8th to 28th, Nov, 1999. Researcher and investigator did pilot study for selecting compatible hospice patient classification indicators. After modifying patient classification indicators and nursing care details for general ward, approved of content validity by specialist. Using hospice patient classification indicators and per 5 min continuing observation method, researcher and investigator recorded direct nursing care hours, indirect nursing care hours, and personnel time on hospice nursing care hours, and personnel time on hospice nursing care activities sheet. All of the patients were classified into Class I(mildly ill), Class II (moderately ill), Class III (acutely ill), and Class IV (critically ill) by patient classification system (PCS) which had been carefully developed to be suitable for the Korean hospice ward. And then the elements of the nursing care cost was investigated. Based on the data from an accounting section (Riccolo, 1988), nursing care hours per patient per day in each class and nursing care cost per patient per hour were multiplied. And then the mean of the nursing care cost per patient per day in each class was calculated. Using SAS, The number of patients in class and nursing activities in duty for nursing care hours were calculated the percent, the mean, the standard deviation respectively. According to the ANOVA and the $Scheff{\'{e}$ test, direct nursing care hours per patient per day for the each class were analyzed. The results of this study were summarized as follows : 1. Distribution of patient class : class IN(33.5%) was the largest class the rest were class II(26.1%) class III(22.6%), class I(17.8%). Nursing care requirements of the inpatients in hospice ward were greater than that of the inpatients in general ward. 2. Direct nursing care activities : Measurement ${\cdot}$ observation 41.7%, medication 16.6%, exercise ${\cdot}$ safety 12.5%, education ${\cdot}$ communication 7.2% etc. The mean hours of direct nursing care per patient per day per duty were needed ; 69.3 min for day duty, 64.7 min for evening duty, 88.2 min for night duty, 38.7 min for shift duty. The mean hours of direct nursing care of night duty was longer than that of the other duty. Direct nursing care hours per patient per day in each class were needed ; 3.1 hrs for class I, 3.9 hrs for class II, 4.7 hrs for class III, and 5.2 hrs for class IV. The mean hours of direct nursing care per patient per day without the PCS was 4.1 hours. The mean hours of direct nursing care per patient per day in class was increased significantly according to increasing nursing care requirements of the inpatients(F=49.04, p=.0001). The each class was significantly different(p<0.05). The mean hours of direct nursing care of several direct nursing care activities in each class were increased according to increasing nursing care requirements of the inpatients(p<0.05) ; class III and class IV for medication and education ${\cdot}$ communication, class I, class III and class IV for measurement ${\cdot}$ observation, class I, class II and class IV for elimination ${\cdot}$ irrigation, all of class for exercise ${\cdot}$ safety. 3. Indirect nursing care activities and personnel time : Recognization 24.2%, house keeping activity 22.7%, charting 17.2%, personnel time 11.8% etc. The mean hours of indirect nursing care and personnel time per nursing manpower was 4.7 hrs. The mean hours of indirect nursing care and personnel time per duty were 294.8 min for day duty, 212.3 min for evening duty, 387.9 min for night duty, 143.3 min for shift duty. The mean of indirect nursing care hours and personnel time of night duty was longer than that of the other duty. 4. The mean hours of indirect nursing care and personnel time per patient per day was 2.5 hrs. 5. The mean hours of nursing care per patient per day in each class were class I 5.6 hrs, class II 6.4 hrs, class III 7.2 hrs, class IV 7.7 hrs. 6. The elements of the nursing care cost were composed of 2,212 won for direct nursing care cost, 267 won for direct material cost and 307 won for indirect cost. Sum of the elements of the nursing care cost was 2,786 won. 7. The mean cost of the nursing care per patient per day in each class were 15,601.6 won for class I, 17,830.4 won for class II, 20,259.2 won for class III, 21,452.2 won for class IV. As above, using modified hospice patient classification indicators and nursing care activity details, many critical ill patients were hospitalized in the hospice unit and it reflected that the more nursing care requirements of the patients, the more direct nursing care hours. Emotional ${\cdot}$ spiritual care, pain ${\cdot}$ symptom control, terminal care, education ${\cdot}$ communication, narcotics management and delivery, attending funeral ceremony, the major nursing care activities, were also the independent hospice service. But it is not compensated by the present medical insurance system. Exercise ${\cdot}$ safety, elimination ${\cdot}$ irrigation needed more nursing care hours as equal to that of intensive care units. The present nursing management fee in the medical insurance system compensated only a part of nursing car service in hospice unit, which rewarded lower cost that that of nursing care.

  • PDF

Evaluation and Verification of the Attenuation Rate of Lead Sheets by Tube Voltage for Reference to Radiation Shielding Facilities (방사선 방어시설 구축 시 활용 가능한 관전압별 납 시트 차폐율 성능평가 및 실측 검증)

  • Ki-Yoon Lee;Kyung-Hwan Jung;Dong-Hee Han;Jang-Oh Kim;Man-Seok Han;Jong-Won Gil;Cheol-Ha Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.489-495
    • /
    • 2023
  • Radiation shielding facilities are constructed in locations where diagnostic radiation generators are installed, with the aim of preventing exposure for patients and radiation workers. The purpose of this study is seek to compare and validate the trend of attenuation thickness of lead, the primary material in these radiation shielding facilities, at different maximum tube voltages by Monte Carlo simulations and measurement. We employed the Monte Carlo N-Particle 6 simulation code. Within this simulation, we set a lead shielding arrangement, where the distance between the source and the lead sheet was set at 100 cm and the field of view was set at 10 × 10 cm2. Additionally, we varied the tube voltages to encompass 80, 100, 120, and 140 kVp. We calculated energy spectra for each respective tube voltage and applied them in the simulations. Lead thicknesses corresponding to attenuation rates of 50, 70, 90, and 95% were determined for tube voltages of 80, 100, 120, and 140 kVp. For 80 kVp, the calculated thicknesses for these attenuation rates were 0.03, 0.08, 0.21, and 0.33 mm, respectively. For 100 kVp, the values were 0.05, 0.12, 0.30, and 0.50 mm. Similarly, for 120 kVp, they were 0.06, 0.14, 0.38, and 0.56 mm. Lastly, at 140 kVp, the corresponding thicknesses were 0.08, 0.16, 0.42, and 0.61 mm. Measurements were conducted to validate the calculated lead thicknesses. The radiation generator employed was the GE Healthcare Discovery XR 656, and the dosimeter used was the IBA MagicMax. The experimental results showed that at 80 kVp, the attenuation rates for different thicknesses were 43.56, 70.33, 89.85, and 93.05%, respectively. Similarly, at 100 kVp, the rates were 52.49, 72.26, 86.31, and 92.17%. For 120 kVp, the attenuation rates were 48.26, 71.18, 87.30, and 91.56%. Lastly, at 140 kVp, they were measured 50.45, 68.75, 89.95, and 91.65%. Upon comparing the simulation and experimental results, it was confirmed that the differences between the two values were within an average of approximately 3%. These research findings serve to validate the reliability of Monte Carlo simulations and could be employed as fundamental data for future radiation shielding facility construction.