• 제목/요약/키워드: Material Safety A Sheet

검색결과 78건 처리시간 0.024초

미량 및 신종유해물질의 국내 방류 환경에서의 위해성 평가: 환경부 지정 1순위 80종 대상으로 (Risk Assessment of Micro and Emerging Contaminants in Domestic Effluent Environment: Targeting on 80 First-class substances assigned by Ministry of Environment)

  • 이재엽;박새롬;김일호
    • 한국물환경학회지
    • /
    • 제37권6호
    • /
    • pp.501-509
    • /
    • 2021
  • In 2018, total 263 micro and emerging contaminants were selected as target substances by the Ministry of Environment, and 80 of them were first-class substance including endocrine disruptors, residual Pharmaceuticals and Personal Care Products (PPCPs), residual organic pollutants, pesticides and heavy metals. In this study, in order to evaluate the Hazard Quotient (HQ) of the 80 types in the domestic water environment the concentration of discharged effluent and nearby water environment reported by Korean institutes since 2010 was investigated. There were 45 substances reported to be detected, and Measurement Environment Concentration (MEC) were obtained by collectively converting them into water environment concentration. For biotoxicity, half maximal Effective Dose (EC50) to Daphnia magna, a water fleas species widely adopted in Material Safety Data Sheet (MSDS) was applied. As for the biotoxicity level, the Predicted No-Effect Concentration (PNEC) was obtained by applying the Assessment Factor (AF) and the HQ was derived by dividing it from the MEC. As a result of calculating the HQ, more than 1 substances were Cabamazepine, Mefenamic acid, Acetaminophen, Ibuprofen, Nonylphenol, Nickel, Erythromycin, Acetylslic acid, etc. Meanwhile, perfluorinated compounds were identified as hazardous substances in the water env ironment, with 5 out of 14 species included in the 20 ranks of first-class substance.

FRP를 활용한 수상 부유식 태양광발전 구조물의 요소기술 개발 (Development of Element Technique for the Floating PV Generation Structure Using FRP)

  • 서수홍;최진우;주형중;남정훈;윤순종
    • Composites Research
    • /
    • 제27권3호
    • /
    • pp.103-108
    • /
    • 2014
  • 섬유강화복합재는 단위중량당 강도와 강성이 뛰어나고, 단위중량이 작으며, 내부식성이 뛰어난 점 등의 다양한 재료성질의 장점이 있는 재료로서 건설분야에 적용이 점차 증가하고 있으며, 섬유강화복합재의 건설분야에 활용한 예로 수상 부유식 태양광발전 구조물이 있다. 수상 부유식 태양광발전 구조물은 최근 저탄소 녹색성장의 대표적인 사례로 각광받고 있으며, 안전성 및 경제성을 확보하기 위한 연구가 다수 진행되었다. 또한 수상 부유식 태양광발전 구조물은 최근 국내에 상용화 단지가 시공되었다. 본 논문에서는 상용화 과정에서 경제성 및 시공성을 위해 개발된 수상 부유식 태양광발전 구조물의 요소기술의 연구 개발 내용을 제시하였다.

바이오디젤 혼합물의 인화 및 연소 위험성에 관한 연구 (A Study on the Flammability and Combustion Risk of Biodiesel Mixture)

  • 김주석;고재선
    • 한국재난정보학회 논문집
    • /
    • 제17권1호
    • /
    • pp.10-24
    • /
    • 2021
  • 연구목적: 본 연구의 목적은 현재 대체연료로 사용하고 있는 바이오디젤과 일반디젤 혼합물의 위험성을 장비별(태그방식과 펜스키마르텐 방식) 시험방식에 따른 인화점 및 연소점의(밀폐, 오픈) 차이를 비교 분석, 측정함으로서 혼합물의 위험성을 확인하고, 화학물질의 위험성 평방법을 확립하여 화재원인 물질의 감식과 감정에 참고 자료로 활용하고자 함이다. 연구방법: 인화점 실험 방법 및 결과 처리는 원유 및 석유 제품 인화점 및 연소점 시험방법으로 사용되고 있는 테그밀폐식 및 펜스키마텐스식 시험방법인 ASTM 및 KS M mode를 기준으로 실험하였다. 본 실험에 사용한 장비의 제조사는 일본의 TANAKA사에서 생산한 장비로 KS M 2010의 시험규격을 만족하는 시험장비로 인화점 및 연소점을 측정하였고, 바이오디젤과 일반디젤 혼합물의 시험방식에 따른 인화점(밀폐, 오픈) 차이를 확인하고, 바이오디젤과 일반디젤 혼합물의 발화점을 기존의 디젤과의 비교 발화위험성을 비교 분석하였다. 연구결과: 실험결과를 살펴보면 먼저 혼합물의 인화 위험성에 대한 실험 결과 분석으로 인화점이 64.5℃인 일반 디젤을 기준으로 했을 때 바이오디젤이 70% 함유된 물질의 인화점은 약 92℃로 확인되었고, 가솔린과 바이오디젤 또는 바이오디젤 혼합물을 합성했을 때 인화점이 낮아지는 경향을 확인할 수 있었다. 아울러 인화점과 연소점의 차이는 약 20~30℃정도로 분석되었고, 소량의 가솔린 또는 메탄올의 혼합시 인화점은 낮아지나, 연소점은 기존의 혼합물의 연소점과 유사하다는 것을 확인하였다. 결론: 본 연구에서는 기존의 위험물안전관리법렬상의 위험물 판정 기준에 대한 세부내용의 실효성 확보 및 위험물 판정의 신뢰성 및 재현성 확보를 목적으로, 인화성 혼합물에 대한 실험적 연구를 통해서 혼합물에 대한 위험성 판단기준을 확인, 소방현장에서 단속되는 인화성 액체 대한 실험적 판정 기준에 대한 참고적인 자료를 제공할 수 있을 것이다. 또한 향후 본 연구로 시험방법별 실험에 대한 노하우를 축적한다면 위험물의 위험성 평가 연구에 있어 기초 자료이자 위험물 판정에 관한 연구의 기반으로 활용될 수 있기를 기대한다.

스탬핑용 고강도강 TRB 판재의 성형 특성 (The formability of high strength steel plate applied TRB for stamping)

  • 박현경;정지원;이경민
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.184-189
    • /
    • 2018
  • 최근에 안전기준과 환경규제 강화의 증대로 인해, 차체의 경량화에 대한 연구가 지속적으로 증가하고 있다. 고강도강의 응용은 가장 보편화 된 차체 경량화의 효과적인 방법 중에 하나이다. TWB(Tailor Welded Blank)는 다양한 두께와 용접을 사용하여 부분적인 강도와 경량화를 만족시키는 주요한 공법으로 활용되고 있다. 그러나 추가적인 용접공정으로 인해 판재간의 용접성이 중요하고 용접부에 대한 품질관리가 중요하다. 이점을 개선하기 위해, TRB(Tailor Rollded Blank)공법이 제안되었다. TRB는 롤러 압력을 조절하여 판재의 두께를 다르게 하고, 용접을 사용하는 TWB 공법보다 추가적인 용접공정이 없기 때문에 생산 비용적인 측면에서 훨씬 더 효율적이다. 본 연구에서는 Blank의 압연 영향을 조사하기 위해 스탬핑용 고강도강 TRB 판재의 성형성을 분석하였다. 성형성을 분석하기 위해, TRB 판재에서 0.8 mm, 1 mm의 두께를 갖는 부분을 채취하여 시험하였다. 시편에 새겨진 그리드마킹의 변형도를 분석하여 변형률을 조사하였고, 0.8 mm와 1.0 mm의 두께를 갖는 TRB 시편으로 Erichsen 시험을 한 후에 FE분석을 활용하여 성형성과 고유진동수를 비교하였다.

수상 부유식 태양광발전 구조물의 구조적 성능 평가 (Structural Performance Evaluation of Floating PV Power Generation Structure System)

  • 최진우;서수홍;주형중;윤순종
    • 대한토목학회논문집
    • /
    • 제34권5호
    • /
    • pp.1353-1362
    • /
    • 2014
  • 최근 화석연료의 과도한 소비로 인해 다양한 환경문제가 발생하고 있으며, 이에 대한 대안으로 신재생에너지의 중요성과 그에 대한 시설의 수요가 꾸준히 증가하고 있다. 이러한 수요를 만족하기 위하여, 다수의 태양광발전 구조물들이 건설, 계획되고 있다. 그러나 대부분의 태양광발전 시설들은 육지에 시공되고 있기 때문에 토지 이용에 따른 건설비의 증가와 토지 개간에 의한 추가적인 환경문제 등이 발생하고 있다. 이러한 문제점을 해결하기 위하여 최근 국내에서는 FRP를 활용한 수상 부유식 태양광발전 구조물에 대한 연구를 지속적으로 수행하고 있다. FRP는 높은 강도와 내부식성 및 작은 단위중량 등의 장점을 가지고 있기 때문에 최근 토목분야에서 각광받고 있으며, 이러한 재료적 특성은 자중에 따라 부력체의 크기가 결정되는 수상 구조물에 특히 유용하다. 이 연구에서는 수상 부유식 태양광발전 구조물과 구조물을 구성하는 SMC FRP 수직재의 구조적 성능을 평가하기 위한 해석적, 실험적 연구를 수행하였다. 수상 부유식 태양광발전 구조물은 유한요소해석을 통해 정적거동을 평가하고, 실험을 통해 동적거동을 평가하였다. 또한 SMC FRP 수직재는 유한요소해석을 통해 구조안전성 및 좌굴안정성을 평가하였으며, 실험을 통해 압축 및 인발 하중에 대한 구조적 거동 특성을 검토하였다. 검토 결과 펄트루젼 FRP (pultruded FRP)와 SMC (Sheet Modoling Compound) FRP로 구성된 구조시스템은 외부하중에 대한 안전성을 확보하고 있음을 확인하였다.

50인 미만 소규모사업장의 보건관리 실태 (Current State of Occupational Health in Small-Scale-Enterprises of Korea)

  • 윤순녕;김영임;정혜선;김순례;유경혜;송영숙;김화중
    • 지역사회간호학회지
    • /
    • 제11권1호
    • /
    • pp.90-104
    • /
    • 2000
  • This study was carried out to investigate the current state of occupational health management and characteristics of employees working in small-scale-enterprises (SSE) employing less than 50 workers. Samples were chosen among the two thousands employees working in 838 factories where located in Youngdungpo-Ku, Seoul, Korea. The study results were as followed: 1. Most factories investigated in the study were manufactures (68.6%) which were established in 5 to 10 years ago (29.2%), employing less than 5 workers (72.9%) and registered in accident compensation insurance (23.0%). 2. Health screening was undertaken in 24.9% workplaces for periodic health examination and in 1.5% for special health examination. Environmental monitoring was done in 3.3% factories. Very few factories displayed Material Substance Data Sheet (MSDS) in 3.1% among the total factories. 3. Workplaces usually had their own toilets in 75.9% and washing basin in 58.6% as types of sociowelfare facilities. 4. Employees responded in the study were mostly in the range of age from 30 to 39 in 34.7%. male in 84.8%. the married in 70.3%. manual workers in 42.0%. mostly working regularly 51 hours per a week in 48.2% and earned 710.000 Won to 1.000.000 Won per month in 35.0%. Medical utilization for employees were covered by factories sponsored medical insurance in 12.7% and by provincial sponsored medical insurance in 83.4%. 5. Two point six percents of employees were suffered by diseases. The health complaints indicated were mainly digestive problems in 46.7% and hypertension in 24.4%. 6. Employees wore personal protective equipments for work such as gloves in 48.1%. safety shoes in 30.5%. ear plug in 5.5% and mask in 6.9%. Based on the results of study, we recommend that various types of occupational health management should be developed according to workplace working condition of each factory. In addition to the development of occupational health strategies. we think that it is more important to monitor and to allocate how effectively they operate each other on the basis of longitudinal continuity. Besides, we would like to insist that these all management effort should be focused on prevention of disease and occupational health education of employees.

  • PDF

일 대학병원 호스피스 병동 입원 환자의 간호활동시간 측정과 원가산정 (Determination of Cost and Measurement of nursing Care Hours for Hospice Patients Hospitalized in one University Hospital)

  • 김경운
    • 간호행정학회지
    • /
    • 제6권3호
    • /
    • pp.389-404
    • /
    • 2000
  • This study was designed to determine the cost and measurement of nursing care hours for hospice patients hostpitalized in one university hospital. 314 inpatients in the hospice unit 11 nursing manpower were enrolled. Study was taken place in C University Hospital from 8th to 28th, Nov, 1999. Researcher and investigator did pilot study for selecting compatible hospice patient classification indicators. After modifying patient classification indicators and nursing care details for general ward, approved of content validity by specialist. Using hospice patient classification indicators and per 5 min continuing observation method, researcher and investigator recorded direct nursing care hours, indirect nursing care hours, and personnel time on hospice nursing care hours, and personnel time on hospice nursing care activities sheet. All of the patients were classified into Class I(mildly ill), Class II (moderately ill), Class III (acutely ill), and Class IV (critically ill) by patient classification system (PCS) which had been carefully developed to be suitable for the Korean hospice ward. And then the elements of the nursing care cost was investigated. Based on the data from an accounting section (Riccolo, 1988), nursing care hours per patient per day in each class and nursing care cost per patient per hour were multiplied. And then the mean of the nursing care cost per patient per day in each class was calculated. Using SAS, The number of patients in class and nursing activities in duty for nursing care hours were calculated the percent, the mean, the standard deviation respectively. According to the ANOVA and the $Scheff{\'{e}$ test, direct nursing care hours per patient per day for the each class were analyzed. The results of this study were summarized as follows : 1. Distribution of patient class : class IN(33.5%) was the largest class the rest were class II(26.1%) class III(22.6%), class I(17.8%). Nursing care requirements of the inpatients in hospice ward were greater than that of the inpatients in general ward. 2. Direct nursing care activities : Measurement ${\cdot}$ observation 41.7%, medication 16.6%, exercise ${\cdot}$ safety 12.5%, education ${\cdot}$ communication 7.2% etc. The mean hours of direct nursing care per patient per day per duty were needed ; 69.3 min for day duty, 64.7 min for evening duty, 88.2 min for night duty, 38.7 min for shift duty. The mean hours of direct nursing care of night duty was longer than that of the other duty. Direct nursing care hours per patient per day in each class were needed ; 3.1 hrs for class I, 3.9 hrs for class II, 4.7 hrs for class III, and 5.2 hrs for class IV. The mean hours of direct nursing care per patient per day without the PCS was 4.1 hours. The mean hours of direct nursing care per patient per day in class was increased significantly according to increasing nursing care requirements of the inpatients(F=49.04, p=.0001). The each class was significantly different(p<0.05). The mean hours of direct nursing care of several direct nursing care activities in each class were increased according to increasing nursing care requirements of the inpatients(p<0.05) ; class III and class IV for medication and education ${\cdot}$ communication, class I, class III and class IV for measurement ${\cdot}$ observation, class I, class II and class IV for elimination ${\cdot}$ irrigation, all of class for exercise ${\cdot}$ safety. 3. Indirect nursing care activities and personnel time : Recognization 24.2%, house keeping activity 22.7%, charting 17.2%, personnel time 11.8% etc. The mean hours of indirect nursing care and personnel time per nursing manpower was 4.7 hrs. The mean hours of indirect nursing care and personnel time per duty were 294.8 min for day duty, 212.3 min for evening duty, 387.9 min for night duty, 143.3 min for shift duty. The mean of indirect nursing care hours and personnel time of night duty was longer than that of the other duty. 4. The mean hours of indirect nursing care and personnel time per patient per day was 2.5 hrs. 5. The mean hours of nursing care per patient per day in each class were class I 5.6 hrs, class II 6.4 hrs, class III 7.2 hrs, class IV 7.7 hrs. 6. The elements of the nursing care cost were composed of 2,212 won for direct nursing care cost, 267 won for direct material cost and 307 won for indirect cost. Sum of the elements of the nursing care cost was 2,786 won. 7. The mean cost of the nursing care per patient per day in each class were 15,601.6 won for class I, 17,830.4 won for class II, 20,259.2 won for class III, 21,452.2 won for class IV. As above, using modified hospice patient classification indicators and nursing care activity details, many critical ill patients were hospitalized in the hospice unit and it reflected that the more nursing care requirements of the patients, the more direct nursing care hours. Emotional ${\cdot}$ spiritual care, pain ${\cdot}$ symptom control, terminal care, education ${\cdot}$ communication, narcotics management and delivery, attending funeral ceremony, the major nursing care activities, were also the independent hospice service. But it is not compensated by the present medical insurance system. Exercise ${\cdot}$ safety, elimination ${\cdot}$ irrigation needed more nursing care hours as equal to that of intensive care units. The present nursing management fee in the medical insurance system compensated only a part of nursing car service in hospice unit, which rewarded lower cost that that of nursing care.

  • PDF

방사선 방어시설 구축 시 활용 가능한 관전압별 납 시트 차폐율 성능평가 및 실측 검증 (Evaluation and Verification of the Attenuation Rate of Lead Sheets by Tube Voltage for Reference to Radiation Shielding Facilities)

  • 이기윤;정경환;한동희;김장오;한만석;길종원;백철하
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.489-495
    • /
    • 2023
  • 방사선 방어시설은 진단용 방사선 발생장치가 설치되어 있는 장소에 구축되어 환자, 방사선 작업 종사자 등의 피폭을 방지한다. 본 연구에서는 이러한 방사선 방어시설의 주 재료인 납에 대해 최대관전압별 차폐 두께의 경향성을 몬테칼로 시뮬레이션과 실측을 통해 비교 검증하고자 한다. 몬테칼로 시뮬레이션 코드 중 Monte Carlo N-Particle 6를 활용하였으며 해당 시뮬레이션 상에 모사한 납 차폐 구조도는 선원과 납 시트 사이의 거리는 100 cm, 조사야 크기는 10 × 10 cm2이며 관전압은 80, 100, 120, 140 kVp로 설정하였다. 각 관전압별 에너지 스펙트럼을 산출하여 시뮬레이션에 적용하였다. 80, 100, 120, 140 kVp별 각각 50, 70, 90, 95% 차폐율을 보이는 납 두께를 산출하였다. 80 kVp에서 각 차폐율에 해당하는 두께는 각각 0.03, 0.08, 0.2 1, 0.33 mm이며, 100 kVp에서는 0.05, 0.12, 0.30, 0.50 mm, 120 kVp에서는 0.06, 0.14, 0.38, 0.56 mm, 140 kV p에서는 0.08, 0.16, 0.42, 0.61 mm로 나타났다. 산출된 납 두께에 대해 실측을 진행하였으며 사용된 방사선 발생장치는 GE Healthcare 사의 Discovery XR 656이며 선량계측기의 경우 IBA 사의 MagicMax이다. 실측결과 80 kVp에서 각 두께별 차폐율은 43.56, 70.33, 89.85, 93.05%였으며 100 kVp에서는 52.49, 72.26, 86.31, 92.17%, 120 kVp에서는 48.26, 71.18, 87.30, 91.56%, 140 kVp에서는 50.45, 68.75, 89.95, 91.65%.로 나타났다. 시뮬레이션과 실측을 비교한 결과 두 값의 차이가 평균 약 3% 이내로 작은 것으로 확인되었다. 본 연구의 결과는 몬테칼로 시뮬레이션의 신뢰성을 검증함과 동시에 향후 방사선 방어시설의 구축에 있어 기초 데이터로 활용될 수 있을 것으로 사료된다.