• 제목/요약/키워드: Material Measurements

검색결과 1,577건 처리시간 0.027초

Growth and properties of LCMO/YBCO heterostructure

  • Kumar, Manish;Lee, Hyun Hwi
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.151.1-151.1
    • /
    • 2016
  • Complex oxide heterointerfaces have been extensively explored in the past due to the novel phenomenon emerging at such interfaces that differ from their individual bulk counterparts. The integration of a ferromagnetic (FM) material with the superconducting (SC) material leading to proximity effect is one of the commonly studied phenomenon in these heterostructures. In continuation, we have stabilized the FM layer La0.7Ca0.3MnO3 (LCMO) on SC material YBa2Cu3O7-${\delta}$ (YBCO) using pulsed laser deposition technique and explored the structural, magnetic, electrical and magneto-transport properties of this heterostructure. ${\Phi}$-scan measurements confirm the epitaxial nature of LCMO/YBCO heterostructure grown on single crystalline SrTiO3 substrate. The FM transition of LCMO and SC transition of YBCO are observed in the magnetization measurements of the bilayer structure. Through electrical measurements, we understood that the proximity effect leads to lowering of the SC transition of YBCO. The role of interface in the bilayer structure is also realized through electrical transport measurements.

  • PDF

Accuracy of three-dimensional periodontal ligament models generated using cone-beam computed tomography at different resolutions for the assessment of periodontal bone loss

  • Hangmiao Lyu;Li Xu;Huimin Ma;Jianxia Hou;Xiaoxia Wang;Yong Wang;Yijiao Zhao;Weiran Li;Xiaotong Li
    • 대한치과교정학회지
    • /
    • 제53권2호
    • /
    • pp.77-88
    • /
    • 2023
  • Objective: To develop a method for generating three-dimensional (3D) digital models of the periodontal ligament (PDL) using 3D cone-beam computed tomography (CBCT) reconstruction and to evaluate the accuracy and agreement of the 3D PDL models in the measurement of periodontal bone loss. Methods: CBCT data collected from four patients with skeletal Class III malocclusion prior to periodontal surgery were reconstructed at three voxel sizes (0.2 mm, 0.25 mm, and 0.3 mm), and 3D tooth and alveolar bone models were generated to obtain digital PDL models for the maxillary and mandibular anterior teeth. Linear measurements of the alveolar bone crest obtained during periodontal surgery were compared with the digital measurements for assessment of the accuracy of the digital models. The agreement and reliability of the digital PDL models were analyzed using intra- and interexaminer correlation coefficients and Bland-Altman plots. Results: Digital models of the maxillary and mandibular anterior teeth, PDL, and alveolar bone of the four patients were successfully established. Relative to the intraoperative measurements, linear measurements obtained from the 3D digital models were accurate, and there were no significant differences among different voxel sizes at different sites. High diagnostic coincidence rates were found for the maxillary anterior teeth. The digital models showed high intra- and interexaminer agreement. Conclusions: Digital PDL models generated by 3D CBCT reconstruction can provide accurate and useful information regarding the alveolar crest morphology and facilitate reproducible measurements. This could assist clinicians in the evaluation of periodontal prognosis and establishment of an appropriate orthodontic treatment plan.

Measurements of the rheological properties of standard reference material 2490 using an in-line micro-Fourier rheometer

  • Smith R. S.;Glasscock J. A.
    • Korea-Australia Rheology Journal
    • /
    • 제16권4호
    • /
    • pp.169-173
    • /
    • 2004
  • The control of the rheological properties of a fluid during processing is important and can determine the efficiency of the production in addition to the performance of the final product. The vast majority of process fluids are viscoelastic, hence an instrument that measures both the viscous and elastic properties of the material during processing would be of great practical use. However, most in-line instruments commercially available to date are only capable of measuring viscosity at a single shear rate. An in-line rheometer that measures both the viscous and elastic properties of fluids over a wide range of shear rates simultaneously has been described in a previous publication (Glasscock et at., 2003) in which the results of measurements on flowing sunflower oil were presented. Before this instrument can be used in an industrial situation, it must be demonstrated that the generated results are the same as, or bear some fixed relationship to, the results obtained by conventional off-line rheometers. To this end, the present investigation describes the measurements of a standard reference fluid, polyisobutylene dissolved in 2,6,10,14-tetramethylpentadecane, labelled SRM2490 by the National Institute of Standards and Technology (NIST) in the USA. The results obtained using the in-line rheometer show remarkably good correlation for viscosity, using a modified Cox­Merz rule, with the results supplied with the reference material from NIST.

방사선측정치를 이용한 아스콘 포장 및 노상의 현장밀도와 함수비 측정에 관한 연구 (A Study on the Determination of Density and Moisture Content of Asphalt Concrete Pavement and Subgrade Using Nuclear Density Meter)

  • 진성기;도덕현
    • 한국농공학회지
    • /
    • 제36권4호
    • /
    • pp.103-116
    • /
    • 1994
  • The objective of this study was to determine the criteria for density and moisture content measurements made with a nuclear density meter on common materials in the construction field. The study also sought to test a full-type nuclear density meter in controlling the density of overlay layers( 2.5~5.0cm). In order to determine the accuracy and reliablility of nuclear guage measurements made on construction materials, laboratory and field tests were conducted. Wooden blocks( 65 x 45 ${\times}$ 50 cm) and a special steel compactor( 4.7kg) were constructed in order to carry out tests which were conducted on three different materials; coarse gramed soil, fine grained soil, and AC material. Throughout all laboratory and field tests, the nuclear density and moisture content were determined using Humboldt 5OOLP nuclear gauge. The tests on subgrade material entailed obtaining density measurements by means of both the sand replacement method and the nuclear density meter. The results of the sand replacement method were then compared to the readings recorded bu the meter. As in the subgrade material tests, density measurements made during AC pavement tests were also determined using the unclear meter in addition to a second means; through the core method. The meter readings and core densties were compared as was done in the tests on subgrade materials. The correlation between the results of the sand replacement test( also, the core method) and meter readings on subgrade material was then determined. Sirnilarly, the observed results were then analyzed through linear regression. The tests to determine thin-lift density by means of a full-type nuclear density meter also conducted on the overlay layers( about 4. 8cm thickness) above AC pavements at road construction sities in Korea.

  • PDF

중성자선과 감마선 동시측정이 가능한 휴대용 계측시스템 개발에 관한 연구 (Development of a Portable Detection System for Simultaneous Measurements of Neutrons and Gamma Rays)

  • 김희경;홍용호;정영석;김재현;박수연
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.481-487
    • /
    • 2020
  • Radiation measurement technology has steadily improved and its usage is expanding in various industries such as nuclear medicine, security search, satellite, nondestructive testing, environmental industries and the domain of nuclear power plants (NPPs). Especially, the simultaneous measurements of gamma rays and neutrons can be even more critical for nuclear safety management of spent nuclear fuel and monitoring of the nuclear material. A semiconductor detector comprising cadmium, zinc, and tellurium (CZT) enables to detect gamma-rays due to the significant atomic weight of the elements via immediate neutron and gamma-ray detection. Semiconductor sensors might be used for nuclear safety management by monitoring nuclear materials and spent nuclear fuel with high spatial resolution as well as providing real-time measurements. We aim to introduce a portable nuclide-analysis device that enables the simultaneous measurements of neutrons and gamma rays using a CZT sensor. The detector has a high density and wide energy band gap, and thus exhibits highly sensitive physical characteristics and characteristics are required for performing neutron and gamma-ray detection. Portable nuclide-analysis device is used on NPP-decommissioning sites or the purpose of nuclear nonproliferation, it will rapidly detect the nuclear material and provide radioactive-material information. Eventually, portable nuclide-analysis device can reduce measurement time and economic costs by providing a basis for rational decision making.

저압 화학 증착된 WSix 박막의 열처리에 따른 거동 (Annealing Behaviors of Wsix Film Formed by LPCVD)

  • 이재호;임호빈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1988년도 춘계학술대회 논문집
    • /
    • pp.52-55
    • /
    • 1988
  • Tunsten silicide (WSix) films on polycrystalline silicon were formed by low-pressure chemical vapor deposition (LPCVD) and were annealed in $N_2$ for 30 mins at various temperatures. The annealing behaviors of tungsten silicide films have been investigated by electrical resistivity measurements, X-ray diffraction methods, scanning electron microscopy (SEM) and Hall measurements. The electrical resistivity decreased almost linearly with increasing annealing temperature and reached $35{\mu}{\Omega}-cm$ at $1000^{\circ}C$ annealing. The X-ray and SEM analyses indicate that crystallization of $WSi_2$ and grain growth occurs when annealed above $1000^{\circ}C$. Excess silicon redistribution occurs considerably when annealed above $1000^{\circ}C$. By Hall measurements, the carrier type for specimens annealed at $1000^{\circ}C$ was found to be positive holes, while the carriers were electrons in the specimens that were annealed at $800^{\circ}C$.

  • PDF

CONE CALORIMETER STUDIES OF WOOD SPECIES

  • Grexa, Ondrej;Horvathova, Elena;Osvald, Anton
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.77-84
    • /
    • 1997
  • Cone calorimeter measurements can be used for the calculation of effective material properties, which can be used as input parameters in modeling of fire. Main parameter measured in Cone calorimeter is heat release rate. Some other parameters as time to ignition, effective heat of combustion, mass loss rate or total heat released is also measured in Cone calorimeter. Total heat released is important from the point of view of total energy available in material in Fire situation. Cone calorimeter. measurements were done on several wood species (oak, beech, spruce, poplar). Measurements were provided at external irradiances 30, 50 and 65 ㎾/$m_2$ in horizontal orientation. Heat release rate data were evaluated and compared as a function of external irradiance for various species of wood. furthermore the influence of external irradiance on effective heat of combustion and total heat release was also evaluated for the period of flame combustion.

  • PDF

자유단 공시체에 있어서 압축파, 전단파, 휨파의 공진특성 (Resonances of Unconstrained Compressive, Shear and Flexural Waves in Free-Free Cylinder Specimens)

  • 박병선;조성호;이상헌;강태호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.582-589
    • /
    • 2006
  • Shear wane velocity is important property for grasping the dynamic characteristics of material. It is has been used in various fields such as non-destructive testings of structures, seismic analysis of geotechnical structures and maintenance of concrete structure, and etc. Usually, shear wave velocities of rock cores and concrete cylinders are determined by free-free resonance tests, Shear wave measurement in free-free resonance tests is not straightforward, as compared with rod wave and flexural wane measurements. In This study, a new technique using resonance features of flexural and shear waves were proposed in which the nodal points for the fundamental mode of flexural waves were employed to generate and measure the shear waves with the flexural waves minimized. The real measurements for aluminum cylinders proved validity and reliability of the proposed algorithm. In addition to the proposed algorithm, the effects of material properties on elastic-wave velocities in resonance measurements were also studied. In summary, a new framework of the resonance measurements for shear-wave velocity determination was established, based on the results of this thesis.

  • PDF

초음파 계측에 의한 2.25Cr-1Mo강의 열화도 평가에 관한 연구 (A Study on the Evaluation of Material Degradation for 2.25Cr-1Mo Steel by Ultrasonic Measurements)

  • 박은수;박익근;김정석
    • 한국공작기계학회논문집
    • /
    • 제10권3호
    • /
    • pp.61-67
    • /
    • 2001
  • The remaining life estimation for the aged component is very important because mechanical properties of the compo-nents are degraded with time of service exposure in high temperature etc. The destructive method is widely used for the estimation of material degradation, but it has a difficulty in preparing specimens from in-service industrial facilities. In order to evaluate the feasibility of ultrasonic evaluation method for properties of high temperature materials, 2.25Cr-1Mo steel specimens which were prepared by the isothermal aging heat treatment at 63$0^{\circ}C$ were evaluated by ultra-sonic measurements investigating the change of velocities and attenuation coefficient. In this results, attenuation coefficient was found to be sensitive to material degradation mainly attributed to the change of grain size and the precipitation of impurities in grain boundaries, but velocity was not for all specimens.

  • PDF

테라헤르츠 전자기 펄스를 이용한 이산화규소의 전기적 광학적 특성 (The Electrical and Optical Characteristics of Silica Sand by Terahertz Electromagnetic Pulses)

  • 전태인
    • 한국전기전자재료학회논문지
    • /
    • 제14권3호
    • /
    • pp.202-206
    • /
    • 2001
  • Using THz time-domain spectroscopy (THz-TDS), the power absorption, the index of refraction, and the real conductivity of silica sand are measured from 0.1[Thz] to 0.5[Thz] frequency range. It is impossible to measure the characterization of the silica sand by simple electrical measurements using mechanical contacts, e.g., Hall effect or four-point probe measurements. However, the THz-TDS technique can measure not only electrical but also optical characterization of he sample. Also this technique can measure frequency dependent results. Especially, the real conductivity was increased according to THz frequency. This is unusual material compare with metal and semiconductor materials; the measured real conductivity are not followed by the simple Drude theory.

  • PDF