• 제목/요약/키워드: Material Defects

검색결과 1,308건 처리시간 0.026초

성견 치근이개부 병소에서 흡수성 차폐막의 치주조직재생에 미치는 영향에 대한 조직병리학적 연구 (A Histo-Pathological Study of Effect on Periodontal Regeneration with Bioabsorbable Membrane on The Grade II Furcation Defects in Beagle Dogs)

  • 김재광;임성빈;정진형;이종헌
    • Journal of Periodontal and Implant Science
    • /
    • 제32권1호
    • /
    • pp.161-172
    • /
    • 2002
  • The present study evaluated the effects of guided tissue regeneration using xenograft material(deproteinated bovine bone powder), with and without biodegradable membrane in beagle dogs. Contralateral fenestration defects (6 ${\times}$ 4mm) were created 4 mm apical to the buccal alveolar crest of maxillary premolar teeth in 5 beagle dogs. Deproteinated bovine bone powders were implanted into fenestration defect and one randomly covered biodegradable membrane (experimental group). Biodegradable membrane was used to provide GTR. Tissue blocks including defects with soft tissues which were harvested following four & eight weeks healing interval, prepared for histo-phathologic analysis. The results of this study were as follows. 1. In control group, at 4 weeks after surgery, new bony trabecular contacted with interstitial tissue and osteocytes like cell were arranged in new bony trabecule. Bony lamellation was not observed. 2. In control gruop, at 8 weeks after surgery, scar-like interstitial tissue was filled defect and bony trabecule form lamellation. New bony trabecular was contacted with interstitial tissue but defect was not filled yet. 3. In experimental group, at 4 weeks after surgery, new bony trabecular partially recovered around damaged bone. But new bony trabecular was observed as irregularity and lower density. 4. In experimental group, at 8 weeks after surgery, lamella bone trabecular developed around bone cavity and damaged tissue was replaced with dense interstitial tissue. In conclusion, new bone formation regenerated more in experimental than control groups and there was seen observe more regular bony trabecular in experimental than control groups at 4 weeks after surgery. In control group, at 8 weeks after surgery, the defects was filled with scar-like interstitial tissue but, in experimental group, the defects was connected with new bone. Therefore xenograft material had osteoconduction but could not fill the defects. We thought that the effective regeneration of periodontal tissue, could be achieved using GTR with biodegradable membrane.

Effectiveness of porcine-derived xenograft with enamel matrix derivative for periodontal regenerative treatment of intrabony defects associated with a fixed dental prosthesis: a 2-year follow-up retrospective study

  • Kim, Yeon-Tae;Jeong, Seong-Nyum;Lee, Jae-Hong
    • Journal of Periodontal and Implant Science
    • /
    • 제51권3호
    • /
    • pp.179-188
    • /
    • 2021
  • Purpose: Due to the difficulty of the hygienic care and sanitary management of abutment teeth and subpontic areas associated with fixed dental prostheses (FDPs), intrabony defects occur and accelerate due to the accumulation of plaque and calculus. This study aimed to evaluate the efficacy of regenerative periodontal surgery for intrabony defects associated with FDPs. Methods: The study inclusion criteria were met by 60 patients who underwent regenerative treatment between 2016 and 2018, involving a total of 82 intrabony defects associated with FDPs. Periodontal osseous lesions were classified as 1-, 2-, and 3-wall intrabony defects and were treated with an enamel matrix derivative in combination with bone graft material. The changes in clinical (pocket probing depth [PPD] and clinical attachment level [CAL]) and radiographic (defect depth and width) outcomes were measured at baseline and at 6, 12, and 24 months. Results: Six months after regenerative treatment, a significant reduction was observed in the PPD of 1-wall (P<0.001), 2-wall (P<0.001), and 3-wall (P<0.001) defects, as well as a significant reduction in the CAL of 2-wall (P<0.001) and 3-wall (P<0.001) intrabony defects. However, there was a significant increase in the CAL of 1-wall intrabony defects (P=0.003). Radiographically, a significant reduction in the depth of the 3-wall (P<0.001) defects and a significant reduction in the width of 2-wall (P=0.008) and 3-wall (P<0.001) defects were observed. The depth decreased in 1-wall defects; however, this change was not statistically significant (P=0.066). Conclusions: Within the limitations of the current study, regenerative treatment of 2- and 3-wall intrabony defects associated with FDPs improved clinical and radiological outcomes. Additional prospective studies are necessary to confirm our findings and to assess long-term outcomes.

A Study on Ultrasonic Evaluation of Material Defects in Carbon/carbon Composites

  • Im, Kwang-Hee;David K. Hsu;Cha, Cheon-Seok;Sim, Jae-Ki;Yang, In-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제16권12호
    • /
    • pp.1652-1663
    • /
    • 2002
  • It is desirable to perform nondestructive evaluation to assess material properties and part homogeneity because manufacturing of carbon/carbon (C/C) composites requires complicated and costly processes. In this work several ultrasonic techniques were applied to carbon/carbon composites for the evaluation of spatial variations in material properties that are attributable to the manufacturing process. In a large carbon/carbon composite manufactured by chemical vapor infiltration (CVI) method, the spatial variation of ultrasonic velocity was measured and found to be consistent with the densification behavior in CVI process in order to increase the density of C/C composites. Ultrasonic velocity and attenuation depend on a density variation of materials. Low frequency through-transmission scans based on both amplitude and time-of-flight of the ultrasonic pulse were used for mapping out the material property inhomogeneity These results were compared with that obtained by dry-coupling ultrasonics. Pulse-echo C-scans was used to image near-surface material property anomalies such as the placement of spacers between disks during CVI. Also, optical micrograph had been examined on the surface of C/C composites using a destructive way.

토끼의 두개골내에 형성된 골결손부에서 $HA/{\beta}-TCP$ composite powders의 골형성에 관한 조직학적 연구 (Bone formation effect of $HA/{\beta}-TCP$ composite powders in rabbit calvarial bone defects;Histologic study)

  • 이광호;장현선;박주철;김흥중;김종관;김병옥
    • Journal of Periodontal and Implant Science
    • /
    • 제36권1호
    • /
    • pp.1-14
    • /
    • 2006
  • The purpose of the present study was to evaluate the histologic results of bone cavities that were surgically created in the calvaria of rabbit and filled with $HA/{\beta}-TCP$ composite powders, which had been developed in Korea (Dentium, Korea). Ten young adult rabbits were used. Four defects were surgically produced in calvaria of each rabbit. Each rabbit was anesthetized with Ketamine-HCI (5 mg/kg, Yuhan Cor. Korea) and Xylazine-HCI (1.5 ml/kg, Yuhan Cor. Korea)). An incision was made to the bony cranium and the periosteum was reflected. Using a trephine bur (external diameter: 8 mm, 3i, USA), 4 'through-and-through' bone defects were created with copious irrigation, and classified into 4 groups: control group: no graft materials, experimental group I: normal saline + graft materials: experimental group II: venous blood + graft materials: experimental group III: graft materials only. The defects were randomly filled with graft materials. The defects were closed with resorbable suture material. At the end of the surgical procedure, all animals received a single intramuscular injection of antibiotics Gentamicin (0.1 mg/kg, Dae Sung Microb. Korea). Rabbits were sacrificed with phentobarbital (100 mg/kg) intravenously at 1-, 2-, 4-, 6- and 8-week after. Specimens were treated with hydrochloric acid decalcifying solution (Fisher Scientific, Tustin, CA) and sectioned by bisecting the 8 mm diameter defects. The histologic specimens were prepared in the general method with H & E staining at 6 ${\mu}m$ in thickness. The results were as follows; 1. New bone formation showed from after 2-week of surgery in defect area. As time lapsed, lots of new bone formation and mature bones showed. 2. Histologically, degree of new bone formation could not be discerned among the experimental groups. But, for experimental group II, lots of cells gathered around graft materials after 1-week of surgery, new bone formed slightly faster and than the others at 1-week after. For experimental group I, a few inflammatory finding showed around graft material at after 1-week and after 2-week of surgery. 3. No bone formation did show for control group. Based on histologic results, the new $HA/{\beta}-TCP$ composite powders appeared to act as a scaffolding material for regeneration of osseous defects.

CMP와 Spin Etching에 의한 Blanket Wafer(TEOS) 가공 특성 비교에 관한 연구 (A Study on Machining Characteristic Comparison of Blanket Wafer(TEOS) by CMP and Spin Etching)

  • 김도윤;정해도;이은상
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.1068-1071
    • /
    • 2001
  • Recently, the minimum line width shows a tendancy to decrease and the multi-level to increase in semiconductor. Therefore, a planarization technique is needed, which chemical polishing(CMP) is considered as one of the most important process. CMP accomplishes a high polishing performance and a global planarization of high quality. But there are several defects in CMP such as microscratches, abrasive contaminations, and non-uniformity of polished wafer edges. Spin Etching can improve the defects of CMP. It uses abrasive-free chemical solution instead of slurry. Wafer rotates and chemical solution is simultaneously dispensed on a whole surface of the wafer. Thereby chemical reaction is occurred on the surface of wafer, material is removed. On this study, TEOS film is removed by CMP and Spin Etching, the results are estimated at a viewpoint of material removal rate(MRR) and within wafer non-uniformity(WIWNU).

  • PDF

방사선조사에 따른 원전 저압케이블용 절연재료의 특성분석 (Characterization of Insulation Materials for Low Voltage Cables in a Nuclear Power Plant with ${\gamma}$-Ray Irradiation)

  • 박정기;이우선;한재홍
    • 한국전기전자재료학회논문지
    • /
    • 제14권5호
    • /
    • pp.397-404
    • /
    • 2001
  • This study describes the effect of γ-ray irradiation on the properties of insulation materials for low voltage cables in a nuclear power plant. The radiation effects were characterized by measuring OIT, FTIR, electrical properties of the irradiated specimens. As a result, they showed the decrease of OIT and the increase of chemical structural defects with the increase of γ-ray amount. Also, the electrical properties such as dielectrical constant, tan $\delta$ and current were changed by aging. These changes may come from the increase of chemical structural defects by $\delta$-ray irradiation.

  • PDF

층상구조 재료의 소결: 출발물질이 소결결함 및 잔류응력에 미치는 영향 (Sintering of Layer Structure Materials: Effect of Starting Material on Sintering Defects and Residual Stress)

  • 정연길
    • 한국세라믹학회지
    • /
    • 제36권1호
    • /
    • pp.61-68
    • /
    • 1999
  • 층상구조를 이루는 재료의 소결시 형성되는 다양한 결함 및 잔류응력을 고찰하기 위해 TZP-SUS계 및 ZT/SUS계다층재료와 porcelain/alumina 및 porcelain/Y-TZP 이층재료를 소결법으로 제조하였다. 상압소결로 제조한 다층재료에서는 층간의 소결수축율 차이에 의해 warping, splitting, 균열 등의 소결결함이 관찰되었으며, 중간층수 및 두께의 조절과 출발물질의 제어를 통해 이러한 소결결함이 완화됨을 알 수 있었다. Tape casting법으로 제조한 다층재료에서는 소결시 가한 압력에 의해 소결결함, 특히 warping이 제어됨을 확인할 수 있었다. 이층재료에서 형성되는 잔류응력은 vickers 압입법으로 관찰하였다. Porcelain/alumina에서는 porcelain 측의 계면에 작은 인장응력이, porcelain/Y-TZP에서는 압축응력이 형성됨을 확인할 수 있었으며, 이러한 잔류응력은 이층재료의 강도에도 영향을 미침을 알수 있었다. 결국 다층재료의 소결결함 및 잔류응력은 재료설계와 출발물질 상수에 영향을 받는다는 것을 알 수 있었다.

  • PDF

배열와전류프로브를 이용한 증기발생기 세관의 결함 변화에 따른 유한요소해석 (Finite Element Method Analysis of Eddy Current Array Probe According to Defects Variation of Steam Generator)

  • 김지호;이향범
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.54-58
    • /
    • 2009
  • In this paper, the ECT(eddy current testing) signal analysis of eddy current array probe for inspection of SG(steam generator) tube in NPP(nuclear power plant) using electromagnetic FEM(finite element method) was performed. To obtain the electromagnetic characteristics of probes, the governing equation was derived from Maxwell's equation, and the problem was solved by using the 3-dimensional FEM. The types of defects were FBH(flat bottomed hole) and OD groove, Spiral groove, natural defects(pitting, SCC, multiple SCC, wear). The depth of FBH defects were 20%, 40%, 60%, 80%, 100 of SG tube thickness, and it was assumed that the defects were located on the tube outside. And the operation frequency of 100kHz, 300kHz and 400kHz were used. Material of specimen was Inconel 600 which is usually used for SG tubes in NPP. The signal difference could be observed according to the variation of size and depth on FBH defects and operation frequencies. The results in this paper can be helpful when the ECT signals from EC array probe are evaluated and analyzed.

  • PDF

Acupuncture Therapy for Color Vision Defects

  • Park, Yong-Sin;Kim, Chang-Myung;Lee, Eun-Hee
    • 대한한의학회지
    • /
    • 제35권2호
    • /
    • pp.41-46
    • /
    • 2014
  • Objectives: We have treated people who have color vision defects with oriental medicine; here we demonstrate several representative cases to illustrate the effectiveness of our treatment. Material and methods: We recruited study patients who visited one oriental hospital for color vision defects. We show several representative cases to illustrate the effectiveness of our treatment. The study initially consisted of 178 subjects who took part during a 3-year period. Subjects, all of whom consented to this treatment and trial, were classified by those who have a color vision defect and those who don't by the Ishihara test and another by the Hahn color vision test. We tried color vision correction treatment with acupuncture. Acupuncture therapy where the retina and optic nerves were activated was conducted in parallel with vision correction. Assessment of therapy was conducted at 30 times, 60 times, 90 times, or 120 times of therapy. Results: Assessment of therapy was performed by conducting treatment 30 times, 60 times, 90 times, or 120 times. Surprisingly, all subjects could correctly recognize color after the treatment; although there were case by case differences according to the number of therapy treatments each individual received. Conclusions: Color vision defects can be treated. To enable those with color vision defects to enjoy better quality of life and increased opportunity in color vision-dependent job fields, therapy to correct the problem is a viable option.

진동 억제를 위한 Wafer Packing Box 재료 최적화 (Wafer Packing Box for Vibration Suppression Material Optimization)

  • 윤재훈;허장욱;이일환
    • 반도체디스플레이기술학회지
    • /
    • 제21권2호
    • /
    • pp.51-56
    • /
    • 2022
  • Recently, the demand for semiconductors is expanded to various industries, and the use of high-quality and high-performance chips is increasing. With the trend, the diameter magnification and high integration of the semiconductor wafers are mandatory. As a result, there is a growing demand for the productivity improvement and the surface precision. There have been many studies on the stabilization of the wafer manufacturing processes in order to satisfy those specifications. Many complaints have been appealed by the wafer buyers that there are many unacceptable wafers with surface defects and foreign material adhesion which are caused by the vibrations during transportation. This study intends to derive the material improvement of the packing box of the wafers to suppress the vibrations of the box, and eventually to reduce the surface defects and the foreign material adhesion. The result shows that optimal material can substantially decrease the vibration of the packing box.