• 제목/요약/키워드: Material Changes

검색결과 3,658건 처리시간 0.03초

핸드니트 기법을 응용한 니트디자인 연구 (Knit Design Represented with the Technique of Hand-knit)

  • 박유현;최정욱
    • 대한가정학회지
    • /
    • 제45권4호
    • /
    • pp.43-51
    • /
    • 2007
  • This study analyzed the knit wear trend, which has gained attention as a sensuous and luxury item, through collection magazines, and used the technique of hand-knit to produce and present the knit wear that was designed based on the study results. Accordingly, the purpose of this study is to raise awareness of the expansion of hand knit's new expression techniques and expression areas and to verify its possibility as a higher value-added product. The trends of hand-knit wear resulted from the analysis of collections divided into the following four groups, and the knit designs were also grouped accordingly: First was "The design using object." The trend survey showed the results that the form of drops or flowers was often used as a factor of object. Accordingly, as for the study design, the drop-knitting technique, which is one of the pattern knitting techniques, was used to present a design that employed drops as the object. Second was "The design matched with woven material." It is a way to emphasize aesthetic formativeness and at the same time to activate the area of knit design by matching woven material, which is different from knit in texture, with knit. This study presented a design that tried to combine knit texture and woven material by connecting denim material with various textures and colors. Third was "The design to express see-through." A sense of showing through knit wear was expressed through changes in the type of thread or knitting technique. In this study, the sense of see-through was expressed using piano wires and wool threads and through changes in the thickness of needle. Fourth was "The design to emphasize coloring." It was analyzed that regarding the production of hand knit, the method of coloring expression was to express points, lines and sides or to create harmony by changing the material's color or texture to show particular objects or shapes. In this study, a jacket was designed using the method to express points, lines and sides by changing the material's color.

판파를 이용한 화력 발전 설비의 물성 평가 (Use of Guided Waves for Monitoring Material Conditions in Fossil-Fuel Power Plants)

  • 조윤호;정경식;이재선
    • 대한기계학회논문집A
    • /
    • 제34권6호
    • /
    • pp.695-700
    • /
    • 2010
  • 가스터빈 날개를 덮고 있는 덮개판(Lock plate)의 재료 물성을 유도초음파를 이용하여 측정을 하였다. Lock plate는 가스터빈 발전소에서 아무 극한 환경에서 작동을 하는 부분 중 하나이다. 초음파 속도와 감쇠계수가 서로 다른 3가지 조건의 열처리상태의 재료 물성을 측정하는데 사용되었다. 일반적인 기계적 파괴 인장실험과 비교했을 때, 인코넬 x-750의 재료특성은 다른 열처리 조건에서 탄성계수와 포아슨비를 활용하여 비파괴적인 방법으로 더 효과적으로 알아냈다. 초음파 속도와 인코넬 x-750의 강도는 서로 비례관계에 있으며, 이러한 재료물성 측정은 여러 산업 분야에서 손상 측정에 활용될 수 있다. 또한 유도초음파 기법을 활용하여 장거리, 광범위한 진단으로 시간과 비용을 절감하는데 도움이 되리라 기대된다.

개시제와 교차결합제 농도의 변화에 따른 소프트콘택트렌즈의 물리적 성질과 약물용출 농도의 변화 (Changes in Drug Elution Concentration and Physical Characteristics of Soft Contact Lenses Depending on the Initiator and Crosslinker)

  • 박현주;이현미
    • 한국안광학회지
    • /
    • 제19권2호
    • /
    • pp.145-151
    • /
    • 2014
  • 목적: 개시제와 교차결합제의 농도에 따른 소프트콘택트렌즈의 재질을 변화시켜서 재질변화에 대한 물리적 특성 및 약물의 용출량 및 속도를 비교하였다. 방법: HEMA에 개시제인 AIBN과 교차결합제인 EGDMA의 농도을 변화시켜서 콘택트렌즈를 제작하였다. 항균물질인 노플록사신(norfloxacin)은 고분자 중합 시 0.1% 농도로 단량체와 함께 혼합하였다. 재질변화에 따른 물리적 성질 변화를 확인하기 위해 약물용출 농도, 함수율, 굴절률, 단백질 흡착량 등에 대한 실험을 통하여 비교하였으며, 통계분석을 통해 유의성을 확인하였다. 결과: 개시제의 농도을 변화 시킨 콘택트렌즈는 함수율의 변화가 거의 없으며, 굴절률의 값에도 별 변화가 없었다. 교차결합제 농도이 증가하면 함수율이 낮아지고 굴절률이 높아졌다. 약물용출의 농도를 살펴보면 개시제의 변화에 의해서는 많은 변화를 보이지 않았으며, 함수율이 높을수록 용출되는 농도가 증가하였다. 단백질 흡착양은 개시제에 의한 변화는 거의 없었으며 함수율이 낮을수록 흡착되는 양이 증가하였다. 결론: 개시제의 농도에 대한 변화는 특성 변화에 영향력이 거의 없었으며, 교차결합제 농도에 따라서는 많은 변화를 보였다. 교차결합제의 농도가 증가할수록 함수율은 감소하며 굴절률은 증가하였다. 또한 함수율의 증가에 따라 약물이 많이 용출되었으며 단백질의 흡착량은 감소되었다.

알지네이트 인상재의 혼합방법과 트레이 어드헤시브 도포에 따른 모형의 정확도 비교 (COMPARISON OF THE ACCURACY OF STONE CASTS MADE FROM ALGINATE IMPRESSION MATERIAL BY MIXING METHODS AND APPLICATION OF TRAY ADHESIVE)

  • 김진형;정문규
    • 대한치과보철학회지
    • /
    • 제39권5호
    • /
    • pp.492-501
    • /
    • 2001
  • The use of alginate impression materials today is prevalent because of its efficiency and simplicity in clinical settings. Unfortunately, the simplicity of the procedure tends to lull the dentist into a sense of well-being, and lead him into using careless or sloppy technique. Alginate impression materials are used to fabricate diagnostic and preliminary casts, and the final cast. Incorrect use of this material is known to affect the accuracy of the final prosthesis. The purpose of this study was to compare the effect of different mixing methods of alginate impression material and tray adhesive on the accuracy of the stone cast produced by each method. A total of 30 stone casts were produced by using 3 different types of mixing methods (10 stone cast for each mixing method, respectively). The first method utilized an automatic-mixing machine to mix alginate while the second method was carried out manually, strictly following manufacturer's instructions. The third method also involved manual mixing, but did not follow the manufacturer's instructions and was done in a random fashion. Also, 20 additional stone casts were produced by using alginate with or without tray adhesives were included in the study to evaluate effects of tray adhesives on the accuracy of alginate impression. 10 stone casts were produced by adding tray adhesives to the interior surface of the impression tray prior to taking the impression. The other 10 excluded this step. A total of 50 stone casts were analyzed by the three-dimensional measuring machine to measure and compare the dimensional changes of the impression material of each group. The results are as follows. 1. No significant difference was found between the automatic mixing group and the manually-mixing group(p>0.05). 2. For the group that followed manufacturer's instructions, less dimensional changes were record ed than the group that didn't in measuring distanced 4(p<0.05). 3. The group that used tray adhesives showed less dimensional changes(p<0.05). The findings revealed that mechanical methods of mixing alginate impression materials had little influence on dimensional changes. However, it is proven that following manufacturers instructions in alginate impression taking is an important step in acquiring accurate impressions and tray adhesives may play an important role in enhancing the results.

  • PDF

Influence of wound closure on volume stability with the application of different GBR materials: an in vitro cone-beam computed tomographic study

  • Naenni, Nadja;Berner, Tanja;Waller, Tobias;Huesler, Juerg;Hammerle, Christoph Hans Franz;Thoma, Daniel Stefan
    • Journal of Periodontal and Implant Science
    • /
    • 제49권1호
    • /
    • pp.14-24
    • /
    • 2019
  • Purpose: To assess the influence of using different combinations of guided bone regeneration (GBR) materials on volume changes after wound closure at peri-implant dehiscence defects. Methods: In 5 pig mandibles, standardized bone defects were created and implants were centrally placed. The defects were augmented using different combinations of GBR materials: xenogeneic granulate and collagen membrane (group 1, n=10), xenogeneic granulate and alloplastic membrane (group 2, n=10), alloplastic granulates and alloplastic membrane (group 3, n=10). The horizontal thickness was assessed using cone-beam computed tomography before and after suturing. Measurements were performed at the implant shoulder (HT0) and at 1 mm (HT1) and 2mm (HT2) below. The data were statistically analysed using the Wilcoxon signed-rank test to evaluate within-group differences. Bonferroni correction was applied when calculating statistical significance between the groups. Results: The mean horizontal thickness before suturing was $2.55{\pm}0.53mm$ (group 1), $1.94{\pm}0.56mm$ (group 2), and $2.49{\pm}0.73mm$ (group 3). Post-suturing, the values were $1.47{\pm}0.31mm$ (group 1), $1.77{\pm}0.27mm$ (group 2), and $2.00{\pm}0.48mm$ (group 3). All groups demonstrated a loss of horizontal dimension. Intragroup changes exhibited significant differences in group 1 (P<0.001) and group 3 (P<0.01). Intergroup comparisons revealed statistically significant differences of the relative changes between groups 1 and 2 (P=0.033) and groups 1 and 3 (P=0.015). Conclusions: Volume change after wound closure was minimized by using an alloplastic membrane. The stability of the augmented horizontal thickness was most ensured by using this type of membrane irrespective of the bone substitute material used for membrane support.

차량용 브레이크 코너 모듈에서 마찰재의 온도와 압력에 따른 물성치 변화를 고려한 스퀼 소음 해석 연구 (A Study on Squeal Noise Simulation considering the Friction Material Property Changes according to Temperature and Pressure in an Automotive Brake Corner Module)

  • 조호준;김정태;채호중
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.546-552
    • /
    • 2012
  • This paper is a study on squeal noise simulation under the consideration of temperature and pressure dependent material properties of friction material. For this, data of pressure and temperature dependent material properties of lining is achieved by using lining data base and exponential curve fit. Complex eigenvalue analysis is performed for predicting squeal noise frequency and instability and chassis dynamo test is performed for achieving squeal noise frequency, sound pressure level, occurrence temperature & pressure. Initial multi models are composed for considering complex interface conditions such as pad ear-clip, piston-housing and guide pin-torque member. The simulation result of base models is compared with the test result. Squeal noise simulation under the consideration of temperature and pressure dependent material properties of friction material is performed and analyzed using multi models. And additional condition is disc material property variation. Entire simulation conditions are combined and analyzed. Finally, this paper proposes direction of the warm squeal noise model.

  • PDF

Evaluation on the buffer temperature by thermal conductivity of gap-filling material in a high-level radioactive waste repository

  • Seok Yoon;Min-Jun Kim ;Seeun Chang ;Gi-Jun Lee
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4005-4012
    • /
    • 2022
  • As high-level radioactive waste (HLW) generated from nuclear power plants is harmful to the human body, it must be safely disposed of by an engineered barrier system consisting of disposal canisters and buffer and backfill materials. A gap exists between the canister and buffer material in a HLW repository and between the buffer material and natural rock-this gap may reduce the water-blocking ability and heat transfer efficiency of the engineered barrier materials. Herein, the basic characteristics and thermal properties of granular bentonite, a candidate gap-filling material, were investigated, and their effects on the temperature change of the buffer material were analyzed numerically. Heat transfer by air conduction and convection in the gap were considered simultaneously. Moreover, by applying the Korean reference disposal system, changes in the properties of the buffer material were derived, and the basic design of the engineered barrier system was presented according to the gap filling material (GFM). The findings showed that a GFM with high initial thermal conductivity must be filled in the space between the buffer material and rock. Moreover, the target dry density of the buffer material varied according to the initial wet density, specific gravity, and water content values of the GFM.

Design of Tissue-Transfer Container Using Thermoelectric Element Module

  • Park, Yong Pil;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권2호
    • /
    • pp.66-69
    • /
    • 2017
  • The internal temperature of human-tissue transfers must be steadily maintained regardless of the external environmental changes. An ice pack and dry ice are the coolants for the transfer containers for which heat-insulating materials such as EPP (expended polypeopylene and EPS (expended polystrene) are used; however, changes of the external temperature/pressure and the melting of the coolants that is due to a long carriage result in changes of the internal temperature, and this makes it difficult to maintain the temperature. Accordingly, the thermoelectric element was used to design/manufacture a transfer container to maintain the internal temperature regardless of the external environmental changes. As a result of the measurement of the changes of the internal temperatures of the manufactured thermoelectric-element container and the EPS container over time, the internal temperature of the EPS container was increased, whereas the internal temperature of the thermoelectric-element container was maintained. The temperature of the distilled water that was poured into the containers indicated a pattern identical to that of the internal temperature.

온도조건에 따른 표면보호재의 부착강도 특성 및 변형 특성에 관한 실험적 연구 (An experimental study on the Bonding Strength and Strain of Coating Material according to Temperature Condition)

  • 배준영;권인표;김경덕;강석표;곽주호;김정환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.293-296
    • /
    • 2006
  • Normally, using coating material could result in different performance according to the various changes of environments or operation conditions. For these reasons, there are decreasing tendency for the durability, beauty and scenery of structures as the separation or exfoliation occurred after operation. Especially we must find out not only bond strength characteristics of coating material under temperature conditions but also bond strength reduction under heating-cooling repeat test because Korea has four distinct seasons. In this paper, the deformation and bond strength characteristics of coating material have been investigated. and we suggest some preliminary data of coating material for its best performance under various temperature condition.

  • PDF

실물시험을 통한 흡방습 건축자재의 성능평가 (Performance Evaluation of Water Vapour Adsorption/Desorption Property for a Building Material by Mock up Test)

  • 김혜정;송규동;이윤규
    • KIEAE Journal
    • /
    • 제9권2호
    • /
    • pp.53-58
    • /
    • 2009
  • There are increasing developments and uses of functional building materials are recently developed and introduced to the test method for the materials. Especially, moisture problem has a major role are also being established in indoor air quality problems. The purpose of this study is to evaluate the water vapour adsorption/desorption property of a ceiling material. The variation of the temperature and moisture were measured with the application materials by mock up test based on JIS 1470-1. The result shows that water vapour adsorption/desorption property of ceiling material is appeared in changes of moisture adsorption and desorption in comparison with that of a general ceiling material. Therefore, in case of decreasing and increasing in humidity, these materials can be used as an finishing material to sustain comfort condition.