• 제목/요약/키워드: Matching Ratio

검색결과 501건 처리시간 0.031초

고온초전도 마이크로스트립 안테나의 온도 종속 초고주파 특성 (Microwave Properties of High Tc Superconducting Microstrip Antenna with Temperature Dependence)

  • 정동철;최명호;강형곤;임성훈;한병성
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.124-128
    • /
    • 1999
  • We report microwave properties of high-T$_c$ superconducting (HTS) microstrip antennas without impedance matching circuits, where the impedance mismatching is obvious under the critical temperature (T$_c$). The superconducting thin films used in this report were YBa$_2Cu_3O_{7-x}$ (YBCO) films deposited on MgO substrates produced by pulse laser deposition (PLD) technique. At around T$_c$, 86 K the reflection coefficient rapidly drops, and the standing wave ratio (SWR) becomes almost unity, and the characteristic impedance based on the Smith chart is nearly 50 ${\Omega}$. The reflection coefficient and the SWR of the HTS microstrip antenna were - 62.52 dB and 1.0015, respectively, at the resonant frequency of 11.812 CHz at 86 K.

  • PDF

Physicochemical Characters of Ultra Violet Ray Resistant Deinococcus sp. Isolated from Air Dust

  • Nalae, Yun;Lee, In-Jeong;Lee, Young-Nam
    • 미생물학회지
    • /
    • 제30권6호
    • /
    • pp.483-487
    • /
    • 1992
  • Among a few number of UV-resistant isolated form various environmental sources (10), we made a comparative physio-chemoanalytical study on one of spherical bacteria isolated from air dust, presumably Deinococcus sp. (CM strain 29) with an UV resistant bacterium, Deinococcus radiophilus ATCC 27603 as the reference strain. Our isolate of UV resistant coccus, Deinococcus sp. CM 29 and D. radiophilus ATCC 27603 showed more than 75% matching coefficient in metabolic activity of various substrates. The most predominant cellular fatty acid of both strains was palmitoleic acid (C 16 :1, cis 9), but the detail fatty acid profiles were slightly dissimilar to each other. Cell-bound arange pigment seemed to be an identical chemicals on spectrophotometric analysis. L-ornithine was detected as cell-wall amino acid in both strains. Galactose was detected as cell-wall sugar in D. radiophilus ATCC 27603, whereas glucose in Deinococcus sp. CM 29. G-C molar ratio of both strains was comparable, 63-65%.

  • PDF

An Adaptive FEC Code Control Algorithm for Mobile Wireless Sensor Networks

  • Ahn Jong-Suk;Hong Seung-Wook;Heidemann John
    • Journal of Communications and Networks
    • /
    • 제7권4호
    • /
    • pp.489-498
    • /
    • 2005
  • For better performance over a noisy channel, mobile wireless networks transmit packets with forward error correction (FEC) code to recover corrupt bits without retransmission. The static determination of the FEC code size, however, degrades their performance since the evaluation of the underlying channel state is hardly accurate and even widely varied. Our measurements over a wireless sensor network, for example, show that the average bit error rate (BER) per second or per minute continuously changes from 0 up to $10^{-3}$. Under this environment, wireless networks waste their bandwidth since they can't deterministically select the appropriate size of FEC code matching to the fluctuating channel BER. This paper proposes an adaptive FEC technique called adaptive FEC code control (AFECCC), which dynamically tunes the amount of FEC code per packet based on the arrival of acknowl­edgement packets without any specific information such as signal to noise ratio (SNR) or BER from receivers. Our simulation experiments indicate that AFECCC performs better than any static FEC algorithm and some conventional dynamic hybrid FEC/ARQ algorithms when wireless channels are modeled with two-state Markov chain, chaotic map, and traces collected from real sensor networks. Finally, AFECCC implemented in sensor motes achieves better performance than any static FEC algorithm.

적충 강압형 압전변압기 Ag/Pd 전극의 $TiO_2$ 와 PZT 분말의 첨가에 따른 효과연구 (Effect. of $TiO_2$ and PZT powder additions on the Ag/Pd Electrode for Step-down Multilayer Piezoelectric Transformer)

  • 주현규;김인성;보비엣탕;정순종;김민수;송재성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.334-334
    • /
    • 2010
  • In order to fabricate the multilayer piezoelectric transformer by tape casting method, we investigated the effect of $TiO_2$ and PZT powder additions on the Ag/Pd electrode. Meanwhile, effects of $TiO_2$ and PZT powder additives on the microstructure and electrical properties of Ag/Pd electrode were investigated in detail. In addition, the multilayer piezoelectric transformers were fabricated and the characteristics with various load resistance were measured at resonance frequency. The voltage step-up ratio was continuously change with increasing input voltage and load resistance, and then output voltage and powers were increased with increasing input voltage at matching impedance. The temperature rise of multilayer piezoelectric transformers were increased with increasing input voltage and load resistance. Meanwhile, multilayer piezoelectric transformers sintered at $1100^{\circ}C$ show the favorable characteristics with a power of 15 W at $100\;{\Omega}$.

  • PDF

On-chip Smart Functions for Efficiency Enhancement of MMIC Power Amplifiers for W-CDMA Handset Applications

  • Youn S. Noh;Kim, Ji H.;Kim, Joon H.;Kim, Song G.;Park, Chul S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제3권1호
    • /
    • pp.47-54
    • /
    • 2003
  • New efficiency enhancement techniques have been devised and implemented to InGaP/GaAs HBT MMIC power amplifiers for W-CDMA mobile terminals applications. Two different types of bias current control circuits that select the efficient quiescent currents in accordance with the required output power levels are proposed for overall power efficiency improvement. A dual chain power amplifier with single matching network composed of two different parallel-connected power amplifier is also introduced. With these efficiency enhancement techniques, the implemented MMIC power amplifiers presents power added efficiency (PAE) more than 14.8 % and adjacent channel leakage ratio(ACLR) lower than -39 dBc at 20 dBm output power and PAE more than 39.4% and ACLR lower than -33 dBc at 28 dBm output power. The average power usage efficiency of the power amplifier is improved by a factor of more than 1.415 with the bias current control circuits and even up to a factor of 3 with the dual chain power amplifier.

Post-earthquake building safety evaluation using consumer-grade surveillance cameras

  • Hsu, Ting Y.;Pham, Quang V.;Chao, Wei C.;Yang, Yuan S.
    • Smart Structures and Systems
    • /
    • 제25권5호
    • /
    • pp.531-541
    • /
    • 2020
  • This paper demonstrates the possibility of evaluating the safety of a building right after an earthquake using consumer-grade surveillance cameras installed in the building. Two cameras are used in each story to extract the time history of interstory drift during the earthquake based on camera calibration, stereo triangulation, and image template matching techniques. The interstory drift of several markers on the rigid floor are used to estimate the motion of the geometric center using the least square approach, then the horizontal interstory drift of any location on the floor can be estimated. A shaking table collapse test of a steel building was conducted to verify the proposed approach. The results indicate that the accuracy of the interstory drift measured by the cameras is high enough to estimate the damage state of the building based on the fragility curve of the interstory drift ratio. On the other hand, the interstory drift measured by an accelerometer tends to underestimate the damage state when residual interstory drift occurs because the low frequency content of the displacement signal is eliminated when high-pass filtering is employed for baseline correction.

High Response and Precision Control of Electronic Throttle Controller Module without Hall Position Sensor for Detecting Rotor Position of BLDCM

  • Lee, Sang-Hun;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.97-103
    • /
    • 2013
  • This paper describes the characteristics of Electronic Throttle Controller (ETC) module in BLDC motor without the hall sensor for detecting a rotor position. The proposed ETC control system, which is mainly consisted of a BLDC motor, a throttle plate, a return spring and reduction gear, has a position sensor with an analogue voltage output on the throttle valve instead of BLDC motor for detecting the rotor position. So the additional commutation information is necessarily needed to control the ETC module. For this, the estimation method is applied. In order to improve and obtain the high resolution for the position control, it is generally needed to change the gear ratio of the module or the electrical switching method etc. In this paper, the 3-phase switching between successive commutations is adapted instead of the 2-phase switching that is conventionally used. In addition, the position control with a variable PI gain is applied to improve a dynamic response during a transient period and reduce vibration at a stop in case of matching position reference. The mentioned method can be used to estimate the commutation state and operate the high-precision position control for the ETC module and the high response characteristics. The validity of the proposed method is examined through the experimental results.

저잡음 증폭기를 위한 새로운 구조의 검사용 설계회로 (A New Design-for-Testability Circuit for Low Noise Amplifiers)

  • 류지열;노석호
    • 대한전자공학회논문지TC
    • /
    • 제43권3호
    • /
    • pp.68-77
    • /
    • 2006
  • 본 논문에서는 4.5-5.5GHz 저잡음 증폭기 (low noise amplifiers, LNAs)를 위한 새로운 구조의 검사용 설계(Design-for-Testability, DfT) 회로를 제안한다. 이러한 검사용 설계회로는 고가의 장비를 사용하지 알고도 저잡음 증폭기의 전압 이득, 잡음 지수, 입력 임피던스, 입력 반사 손실 및 출력 신호대 잡음 전력비를 측정한다. 검사용 설계회로는 $0.18{\mu}m$ SiGe 공정을 이용하여 설계되었으며, 입력 임피던스 정합과 직류 출력 전압 측정을 이용한다. 이러한 회로를 이용한 회로 검사 기술은 검사 방법이 간단하고 검사하는데 드는 비용이 저렴하다.

Effect of columnar defects on the irreversibility line in pristine and iodine-intercalated Bi$_2$Sr$_2$CaCu$_2$O$_{8+{\delta}} single crystals

  • Kim, Ki-Joon;Kim, Mun-Seog;Choi, Jae-Hyuk;Kang, W.N.;Lee, Sung-Ik;Ha, Dong-Han;Kim, Dong-Ho
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.45-50
    • /
    • 2000
  • We have investigated the influence of columnar defects (CD) on the vortex dynamics in pristine and iodine-intercalated Bi$_2$Sr$_2$CaCu$_2$O$_{8+{\delta}} single crystals from do SQUID magnetization measurements. Especially, the temperature dependence of the irreversibility fields, H$_{irr}$(T), were studied. Anisotropy ratio ${\gamma}$, estimated from the fitting to the 2-dimensional melting model (A. Schilling et al., Phys. Rev. Lett. 71 1899 (1993)) in higher fields than the matching field B$_{\phi}$ at low temperature region, turns out to be decreased by the iodine-intercalation and additionally by the heavy-ion irradiation.

  • PDF

중환자실 환자의 입실시 반코마이신 내성 장구균 집락의 위험요인과 임상적 결과 (Risk Factors and Clinical Outcomes for Vancomycin-Resistant Enterococcus Colonization on Intensive Care Unit Admission)

  • 변숙진;강지연
    • 대한간호학회지
    • /
    • 제43권2호
    • /
    • pp.287-295
    • /
    • 2013
  • Purpose: The purpose of this study was to identify vancomycin-resistant enterococcus (VRE) colonization rate in patients admitted to the intensive care unit (ICU), associated risk factors and clinical outcomes for VRE colonization. Methods: Of the 7,703 patients admitted to the ICUs between January, 2008 and December, 2010, medical records of 554 VRE colonized and 503 uncolonized patients were reviewed retrospectively. To analyzed the impact of colonization on patients' clinical outcomes, 199 VRE colonized patients were matched with 199 uncolonized patients using a propensity score matching method. Results: During the study period, 567 (7.2%) of the 7,703 patients were colonized with VRE. Multivariate analysis identified the following independent risk factors for VRE colonization: use of antibiotics (odds ratio [OR]=3.33), having bedsores (OR=2.92), having invasive devices (OR=2.29), methicillin-resistant Staphylococcus aureus co-colonization (OR=1.84), and previous hospitalization (OR=1.74). VRE colonized patients were more likely to have infectious diseases than uncolonized patients. VRE colonization was associated with prolonged hospitalization and higher mortality. Conclusion: Strict infection control program including preemptive isolation for high-risk group may be helpful. Further research needs to be done to investigate the effects of active surveillance program on the incidence of colonization or infection with VRE in the ICU.