Enthalpy transport in pulse tube refrigerators (맥동관냉동기의 앤탈피이동)

  • 강영구;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.180-192
    • /
    • 1998
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations assuming that the axial temperature gradient in the pulse tube is constant. Time-averaged second-order conservation equations of mass, momentum and energy were used to show the existence of steady mass streaming and enthalpy streaming. Effects of axial temperature gradient, velocity amplitude ratio and heat transfer between the gas and the wall on the steady mass streaming and enthalpy streaming were shown. Enthalpy loss due to the steady mass streaming is zero for basic and orifice pulse tube refrigerators, but it is proportional to the axial temperature gradient and steady mass flow rate through a pulse tube for double inlet pulse tube refrigerators.

  • PDF

Net Enthalpy Transport in Pulse Tube Refrigerators

  • Kang, Young-Goo;Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.33-44
    • /
    • 1999
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations assuming that the axial temperature gradient in the pulse tube was constant. The time-averaged second-order conservation equations of mass, momentum and energy were used to show the existence of steady mass and enthalpy streaming. Effects of the axial temperature gradient, velocity amplitude ratio, and heat transfer between the gas and the tube wall On the steady mass and enthalpy streaming were shown. Enthalpy loss due to the steady mass streaming is zero for basic and orifice pulse tube refrigerators, but it is proportional to the axial temperature gradient and steady mass flow rate through a pulse tube for double inlet pulse tube refrigerators.

  • PDF

Enthalpy Flow Loss by Steady Mass Streaming in Pulse Tube Refrigerators (맥동관냉동기의 정상상태 질량흐름에 의한 엔탈피손실)

  • 백상호;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.623-631
    • /
    • 2000
  • Effects of the taper angle and the angular velocity of a pulse tube on the enthalpy flow loss associated with the steady mass streaming were analysis by two-dimensional analysis of a pulse tube with variable cross-section. It was shown that the steady mass flux can lead to a large steady second-order temperature. The enthalpy flow loss associated with the steady mass streaming increases as the angular velocity increases. For a pulse tube where the viscous penetration depth is far thinner than the inner radius, the enthalpy flow loss can be significantly reduced by tapering the pulse tube since both the steady mass flux and the steady second-order temperature decrease as the taper angle increase.

  • PDF

Two-Dimensional Analysis Model for Tapered Pulse Tubes (테이퍼를 갖는 맥동관의 2차원 해석모델)

  • Baek, Sang-Ho;Jeong, Eun-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.668-676
    • /
    • 2000
  • A two-dimensional model for pulse tubes with tapered cross-section was proposed. Net enthalpy flow and steady mass streaming were investigated by two-dimensional analysis of mass, momentum and energy equations of the gas as well as energy conservation of the tube wall. Steady mass flux profiles show good agreement with the previous approximate solution. It was shown that steady mass streaming can be reduced by tapering a pulse tube and by increasing the length of a pulse tube. Effects of the velocity phase angle and frequency on steady mass streaming were shown.

FLUID MASS STREAMING IN A CHANNEL UNDER STANDING WALLS VIBRATIONS

  • Lee, Kwi-Joo;Shugan, Igor;Kim, Kyoung-Hwa
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.171-176
    • /
    • 2003
  • Peristaltic mass transfer of fluid in a channel with standing wall oscillations is analyzed. Averaged nonlinear Navier-Stokes equations of motion are examined for a wide range of Reynolds numbers and external pressure drops. Nonpropogating wall oscillations with relatively big amplitudes essentially increase the liquid flow. Most effective intensifying of mass transfer occurred for low Reynolds numbers.

  • PDF

Developing Program for Processing a Mass DEM Data using Streaming Method (스트리밍 방식을 이용한 대용량 DEM 프로세싱 프로그램의 개발)

  • Lee, Dong-Ha;Lee, Yong-Gyun;Suh, Yong-Cheol
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.4
    • /
    • pp.61-66
    • /
    • 2009
  • This Paper describes a new program called DEM Generator need to process DEM from LiDAR data or digital map data. It is difficult to generate raster DEM from LiDAR mass point data sets and digital maps too large to fit into memory. The DEM Generator was designed to process DEM and shaded relief image of GeoTiff format in order of streaming meshes; I/O minimize tag, delaunay triangle, natural neighborhood or TIN, temporary files and grid. It is expected that we can be improved the precision of DEM and solved the time consuming problem of DEM generating of a wider area.

  • PDF

Efficient Real-time Multimedia Streaming System Using Partial Transport Stream for IPTV Services

  • Lee, Eun-Jo;Park, Sung-Kwon
    • Journal of Ubiquitous Convergence Technology
    • /
    • v.2 no.2
    • /
    • pp.88-96
    • /
    • 2008
  • IPTV Content delivery systems over wired networks confront scalability problems due to their high network bandwidth requirement for real-time services. Especially, VoD service provides Trick Mode features such as pause, fast forward and similar operations. However, Trick Mode services are delivered by the method of unicast only for controlling of the stream. With a point of views, this paper propose a new real-time multimedia streaming architecture over IP Networks, which tries to achieve bandwidth efficiency and supporting for mass clients better than traditional unicast services. The proposed methods divide the Transport Stream into a series of segments. After that, this divided partial Transport Stream makes multicast streaming periodically. Meanwhile Set-top Box of a client makes a rearrangement orderly by using Presentation Time Stamp field from the served Transport Stream packets. While the current Transport Stream segment is playing, it should be guaranteed that the next segment is downloaded on time. Consequently, the original video content can be played out continuously. The detail introduction of a new real-time multimedia streaming system with analysis and simulation follows as below.

  • PDF

The Relation of Enhancement Heat Transfer to Acoustic Pressure by Acoustic Streaming (음향흐름에 의한 음압과 열전달 촉진과의 관계)

  • Yang, Ho-Dong;Oh, Yool-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.591-596
    • /
    • 2005
  • The objectives in the present study are to investigate that the enhancement heat transfer was experimentally measured and was compared with the acoustic pressure obtained by numerical analysis. From the results of the present study, a strong Fluid motion initiated by ultrasonic vibrations can affect heat and mass transfer. This phenomenon. called acoustic streaming, clearly observed by PIV measurement leads to increase in velocity of a Fluid which is a crucial physical concept to explain the enhancement heat transfer. The heat transfer coefficient is increased with increase in the ultrasonic intensities. The largest enhancement heat transfer (about 26%) is measured at the ultrasonic intensity of 300W. Acoustic streaming results from sudden acoustic pressure variations in the liquid. The results of numerical analysis reveal that acoustic pressure is increased by 59.5% at the ultrasonic intensity of 300W. The higher acoustic pressure near four ultrasonic transducers develops more intensive flow destroying the flow instability. Also, the profiles of acoustic pressure variation are consistent with those of enhancement heat transfer.

  • PDF

Comparison of Flocculati on-Spectrophotometry and Streaming Current Detector Method to the Control of Flocculants for the Removal of Humic Acid

  • Sang-Kyu Kam;Lee
    • Journal of Environmental Science International
    • /
    • v.1 no.2
    • /
    • pp.137-144
    • /
    • 1992
  • Flocculation-spectrophotometry and streaming current detector( SCD ) method were investigated and compared in order to determine the optimum dosages of synthetic cationic polymers of different charge density and molecular mass for the removal of humic acid. The optimum dosage for each of the polymers was determined with the dosage at which the lowest absorbance of humic acid was shown for the formal. and was determined with the dosage required during charge neutralization of humic acid for the latter It was in good agreement between both methods and there is a strong inverse correlation between the optimum dosage and charge density of the polymers, with highly charged polymer giving the lowest optimum dosage, pointing out the importance the charge neutralization. By flocculation-spectrophotometry, it was found that the absorbance of humid acid with the amount of each of the polymers dosed, changes sharply for polymers of high charge density, but changes rather broadly for polymers of low and middle charge density, Both methods showed that a stoichiometric correlation exists between the optimum dosage of each of the cationic polymers and the negatively charged humic acid.

  • PDF

Comparison of Flocculation-Spectrophotometry and Streaming Current Detector Method to the Control of Flocculants for the Removal of Humic Acid

  • Kam Sang-Kyu;An Lee-Sun;Lee Min-Gyu
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.1 no.2
    • /
    • pp.137-144
    • /
    • 1997
  • Flocculation-spectrophotometry and streaming current detector(SCD) method were investigated and compared in order to determine the optimum dosages of synthetic cationic polymers of different charge density and molecular mass for the removal of humic acid. The optimum dosage for each of the polymers was determined with the dosage at which the lowest absorbance of humic acid was shown for the former and was determined with the dosage required during charge neutralization of humic acid for the latter. It was in good agreement between both methods and there is a strong inverse correlation between the optimum dosage and charge density of the polymers, with highly charged polymer giving the lowest optimum dosage, pointing out the importance the charge neutralization. By flocculation-spectrophotometry, it was found that the absorbance of humic acid with the amount of each of the polymers dosed, changes sharply for polymers of high charge density, but changes rather broadly for polymers of low and middle charge density. Both methods showed that a stoichiometric correlation exists between the optimum dosage of each of the cationic polymers and the negatively charged humic acid.

  • PDF