• 제목/요약/키워드: Mass streaming

검색결과 23건 처리시간 0.025초

맥동관냉동기의 앤탈피이동 (Enthalpy transport in pulse tube refrigerators)

  • 강영구;정은수
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.180-192
    • /
    • 1998
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations assuming that the axial temperature gradient in the pulse tube is constant. Time-averaged second-order conservation equations of mass, momentum and energy were used to show the existence of steady mass streaming and enthalpy streaming. Effects of axial temperature gradient, velocity amplitude ratio and heat transfer between the gas and the wall on the steady mass streaming and enthalpy streaming were shown. Enthalpy loss due to the steady mass streaming is zero for basic and orifice pulse tube refrigerators, but it is proportional to the axial temperature gradient and steady mass flow rate through a pulse tube for double inlet pulse tube refrigerators.

  • PDF

Net Enthalpy Transport in Pulse Tube Refrigerators

  • Kang, Young-Goo;Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.33-44
    • /
    • 1999
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations assuming that the axial temperature gradient in the pulse tube was constant. The time-averaged second-order conservation equations of mass, momentum and energy were used to show the existence of steady mass and enthalpy streaming. Effects of the axial temperature gradient, velocity amplitude ratio, and heat transfer between the gas and the tube wall On the steady mass and enthalpy streaming were shown. Enthalpy loss due to the steady mass streaming is zero for basic and orifice pulse tube refrigerators, but it is proportional to the axial temperature gradient and steady mass flow rate through a pulse tube for double inlet pulse tube refrigerators.

  • PDF

맥동관냉동기의 정상상태 질량흐름에 의한 엔탈피손실 (Enthalpy Flow Loss by Steady Mass Streaming in Pulse Tube Refrigerators)

  • 백상호;정은수
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.623-631
    • /
    • 2000
  • Effects of the taper angle and the angular velocity of a pulse tube on the enthalpy flow loss associated with the steady mass streaming were analysis by two-dimensional analysis of a pulse tube with variable cross-section. It was shown that the steady mass flux can lead to a large steady second-order temperature. The enthalpy flow loss associated with the steady mass streaming increases as the angular velocity increases. For a pulse tube where the viscous penetration depth is far thinner than the inner radius, the enthalpy flow loss can be significantly reduced by tapering the pulse tube since both the steady mass flux and the steady second-order temperature decrease as the taper angle increase.

  • PDF

테이퍼를 갖는 맥동관의 2차원 해석모델 (Two-Dimensional Analysis Model for Tapered Pulse Tubes)

  • 백상호;정은수
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.668-676
    • /
    • 2000
  • A two-dimensional model for pulse tubes with tapered cross-section was proposed. Net enthalpy flow and steady mass streaming were investigated by two-dimensional analysis of mass, momentum and energy equations of the gas as well as energy conservation of the tube wall. Steady mass flux profiles show good agreement with the previous approximate solution. It was shown that steady mass streaming can be reduced by tapering a pulse tube and by increasing the length of a pulse tube. Effects of the velocity phase angle and frequency on steady mass streaming were shown.

FLUID MASS STREAMING IN A CHANNEL UNDER STANDING WALLS VIBRATIONS

  • Lee, Kwi-Joo;Shugan, Igor;Kim, Kyoung-Hwa
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 추계학술대회 논문집
    • /
    • pp.171-176
    • /
    • 2003
  • Peristaltic mass transfer of fluid in a channel with standing wall oscillations is analyzed. Averaged nonlinear Navier-Stokes equations of motion are examined for a wide range of Reynolds numbers and external pressure drops. Nonpropogating wall oscillations with relatively big amplitudes essentially increase the liquid flow. Most effective intensifying of mass transfer occurred for low Reynolds numbers.

  • PDF

스트리밍 방식을 이용한 대용량 DEM 프로세싱 프로그램의 개발 (Developing Program for Processing a Mass DEM Data using Streaming Method)

  • 이동하;이영균;서용철
    • 대한공간정보학회지
    • /
    • 제17권4호
    • /
    • pp.61-66
    • /
    • 2009
  • 본 연구는 넓은 지역의 DEM 생성 시 하드웨어 성능에 따라 자료를 부분적으로 처리해야 하는 불편을 개선하고 DEM의 정밀도를 개선하는 것에 그 목적이 있다. 본 연구에서 개발된 DEM Generator 프로그램은 대용량 LiDAR 자료, 수치지형도 자료에 스트리밍 방식을 적용하여 인덱싱 및 델로니 삼각망 생성을 수행하고, Natural Neighborhood 또는 TIN 보간법을 적용한 가상 파일을 생성하여 특정한 해상도로 대규모 지역의 DEM 및 음영기 복도를 효율적으로 생성하도록 설계되었다. 최종적으로 생성된 DEM 및 음영기복도는 GeoTIFF 포맷으로 제공된다. DEM Generator 프로그램은 GIS, 기상, 환경 분석 등 넓은 지역의 DEM 생성이 필요한 분야에서 기존의 부분적인 DEM 생성 및 인접 처리 과정에 의해 발생했던 시간적 경제적 손실을 절감시킬 수 있을 것으로 판단되며, 추가적인 인접 및 수정 작업이 불필요하여 DEM의 정밀도를 높일 수 있을 것으로 판단된다.

  • PDF

Efficient Real-time Multimedia Streaming System Using Partial Transport Stream for IPTV Services

  • Lee, Eun-Jo;Park, Sung-Kwon
    • Journal of Ubiquitous Convergence Technology
    • /
    • 제2권2호
    • /
    • pp.88-96
    • /
    • 2008
  • IPTV Content delivery systems over wired networks confront scalability problems due to their high network bandwidth requirement for real-time services. Especially, VoD service provides Trick Mode features such as pause, fast forward and similar operations. However, Trick Mode services are delivered by the method of unicast only for controlling of the stream. With a point of views, this paper propose a new real-time multimedia streaming architecture over IP Networks, which tries to achieve bandwidth efficiency and supporting for mass clients better than traditional unicast services. The proposed methods divide the Transport Stream into a series of segments. After that, this divided partial Transport Stream makes multicast streaming periodically. Meanwhile Set-top Box of a client makes a rearrangement orderly by using Presentation Time Stamp field from the served Transport Stream packets. While the current Transport Stream segment is playing, it should be guaranteed that the next segment is downloaded on time. Consequently, the original video content can be played out continuously. The detail introduction of a new real-time multimedia streaming system with analysis and simulation follows as below.

  • PDF

음향흐름에 의한 음압과 열전달 촉진과의 관계 (The Relation of Enhancement Heat Transfer to Acoustic Pressure by Acoustic Streaming)

  • 양호동;오율권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.591-596
    • /
    • 2005
  • The objectives in the present study are to investigate that the enhancement heat transfer was experimentally measured and was compared with the acoustic pressure obtained by numerical analysis. From the results of the present study, a strong Fluid motion initiated by ultrasonic vibrations can affect heat and mass transfer. This phenomenon. called acoustic streaming, clearly observed by PIV measurement leads to increase in velocity of a Fluid which is a crucial physical concept to explain the enhancement heat transfer. The heat transfer coefficient is increased with increase in the ultrasonic intensities. The largest enhancement heat transfer (about 26%) is measured at the ultrasonic intensity of 300W. Acoustic streaming results from sudden acoustic pressure variations in the liquid. The results of numerical analysis reveal that acoustic pressure is increased by 59.5% at the ultrasonic intensity of 300W. The higher acoustic pressure near four ultrasonic transducers develops more intensive flow destroying the flow instability. Also, the profiles of acoustic pressure variation are consistent with those of enhancement heat transfer.

  • PDF

Comparison of Flocculati on-Spectrophotometry and Streaming Current Detector Method to the Control of Flocculants for the Removal of Humic Acid

  • Sang-Kyu Kam;Lee
    • 한국환경과학회지
    • /
    • 제1권2호
    • /
    • pp.137-144
    • /
    • 1992
  • Flocculation-spectrophotometry and streaming current detector( SCD ) method were investigated and compared in order to determine the optimum dosages of synthetic cationic polymers of different charge density and molecular mass for the removal of humic acid. The optimum dosage for each of the polymers was determined with the dosage at which the lowest absorbance of humic acid was shown for the formal. and was determined with the dosage required during charge neutralization of humic acid for the latter It was in good agreement between both methods and there is a strong inverse correlation between the optimum dosage and charge density of the polymers, with highly charged polymer giving the lowest optimum dosage, pointing out the importance the charge neutralization. By flocculation-spectrophotometry, it was found that the absorbance of humid acid with the amount of each of the polymers dosed, changes sharply for polymers of high charge density, but changes rather broadly for polymers of low and middle charge density, Both methods showed that a stoichiometric correlation exists between the optimum dosage of each of the cationic polymers and the negatively charged humic acid.

  • PDF

Comparison of Flocculation-Spectrophotometry and Streaming Current Detector Method to the Control of Flocculants for the Removal of Humic Acid

  • Kam Sang-Kyu;An Lee-Sun;Lee Min-Gyu
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제1권2호
    • /
    • pp.137-144
    • /
    • 1997
  • Flocculation-spectrophotometry and streaming current detector(SCD) method were investigated and compared in order to determine the optimum dosages of synthetic cationic polymers of different charge density and molecular mass for the removal of humic acid. The optimum dosage for each of the polymers was determined with the dosage at which the lowest absorbance of humic acid was shown for the former and was determined with the dosage required during charge neutralization of humic acid for the latter. It was in good agreement between both methods and there is a strong inverse correlation between the optimum dosage and charge density of the polymers, with highly charged polymer giving the lowest optimum dosage, pointing out the importance the charge neutralization. By flocculation-spectrophotometry, it was found that the absorbance of humic acid with the amount of each of the polymers dosed, changes sharply for polymers of high charge density, but changes rather broadly for polymers of low and middle charge density. Both methods showed that a stoichiometric correlation exists between the optimum dosage of each of the cationic polymers and the negatively charged humic acid.

  • PDF