• 제목/요약/키워드: Mass standards

검색결과 465건 처리시간 0.026초

소형 전기자동차 CAN 데이터 기반의 시뮬레이션 모델 개발 (Development of a Simulation Model based on CAN Data for Small Electric Vehicle)

  • 이홍진;차준표
    • 한국분무공학회지
    • /
    • 제27권3호
    • /
    • pp.155-160
    • /
    • 2022
  • Recently, major developed countries have strengthened automobile fuel efficiency regulations and carbon dioxide emission allowance standards to curb climate change caused by global warming worldwide. Accordingly, research and manufacturing on electric vehicles that do not emit pollutants during actual driving on the road are being conducted. Several automobile companies are producing and testing electric vehicles to commercialize them, but it takes a lot of manpower and time to test and evaluate mass-produced electric vehicles with driving mileage of more than 300km on a per-charge. Therefore, in order to reduce this, a simulation model was developed in this study. This study used vehicle information and MCT speed profile of small electric vehicle as basic data. It was developed by applying Simulink, which models the system in a block diagram method using MATLAB software. Based on the vehicle dynamics, the simulation model consisted of major components of electric vehicles such as motor, battery, wheel/tire, brake, and acceleration. Through the development model, the amount of change in battery SOC and the mileage during driving were calculated. For verification, battery SOC data and vehicle speed data were compared and analyzed using CAN communication during the chassis dynamometer test. In addition, the reliability of the simulation model was confirmed through an analysis of the correlation between the result data and the data acquired through CAN communication.

상업용 건물에 있어서 외벽의 축열용량이 난방부하에 미치는 영향 연구 - ASHRAE Standard 90. 1안에서 사용된 Delta Load 개념의 평가 - (COMPARISON OF THE EFFECTS OF THERMAL MASS EXTERIOR WALLS ON HEATING AND COOLING LOADS IN COMMERCIAL BUILDINGS - Evaluation of Delta Load Concept Used in The Draft Standard ASHRAE 90. 1 -)

  • 박상동
    • 대한설비공학회지:설비저널
    • /
    • 제15권4호
    • /
    • pp.372-379
    • /
    • 1986
  • 본고는 상업용 건물에 있어서의 냉난방부하에 대한 외벽의 축열(열용량)효과를 비교$\cdot$분석하는데 그 목적이 있다. 가장 최근에 발표된 에너지 해석 프로그램인 DOE-2.1C를 이용하여 Berkeley Solar Group (BSG) 이 제안한 축열효과를 분석하였다. 본 고에서의 축열효과는 "delta load"로서 표현되어 있으며 "delta load"는 전형적인 나무구조 건물과 벽돌조 건물의 연간 냉난방부하의 차이로서 표시된다. BSG 보고서에 의하면 delta load는 (1)구조물의 위치와 관련한 단열방법 (2)벽의 열용량 (3)벽의 열관류을 (4)기후조건에 따라 달라진다고 되어 있다. 본 고에서의 delta load 계산은 중규모 사무소 건물을 대상으로 하였으며 Lake Charles, LA와 Madison, WI 기후 데이터를 사용하였는데 DOE-2.1C 사용에 의한 delta load는 BSG의 결과와 일반적으로 잘 조화가 되는 것으로 나타났으나 외주부의 방향에 따른 dalta load와 난방에 있어서는 다소 큰 차이를 보여 주고 있으며, 외단열과 중간열의 효과는 BSG의 결과와 마찬가지로 비슷하였다.

  • PDF

반 건조 하수슬러지와 폐플라스틱 혼합물의 파일롯 규모 연속식 열분해에 의한 생산물과 발생 오염물질 (Products and pollutants of half dried sewage sludge and waste plastic co-pyrolysis in a pilot-scale continuous reactor)

  • 김용화;천승규
    • 한국응용과학기술학회지
    • /
    • 제34권2호
    • /
    • pp.327-337
    • /
    • 2017
  • 반 건조 소화 하수슬러지와 폐플라스틱을 혼합하여 파일롯 규모(85.3kg/hr)의 연속식 저온($510^{\circ}C{\sim}530^{\circ}C$) 열분해 실험을 하였다. 실험결과 열분해가스 발생량은 투입물 건량의 최대 68.3%, 발열량은 $40.9MJ/Nm^3$이었으며, 연속식 열분해에 따른 외기 유입율이 19.6%이었다. 오일은 투입물 건량의 4.2%가 발생하였고, 저위발열량은 32.5 MJ/kg이었으며 시설부식 등을 일으킬 수 있는 황과 염소의 함량이 각각 0.2% 이상이었다. 투입물 건량의 27.5%가 발생한 탄화물의 저위 발열량은 10.2 MJ/kg이었고, 용출시험 결과 지정폐기물에 해당하지 않았다. 열분해가스의 연소 배가스는 일산화탄소, 황산화물, 시안화수소 등의 배출농도가 특히 높았고, 다이옥신 (PCDDs/DFs)은 $0.034ng-TEQ/Sm^3$로서 법적 기준치 이내였다. 건조 배가스 응축으로 발생한 폐수는 수질오염물질 47개 항목 중 총질소, n-H 추출물질, 시안 등의 고농도 항목이 많아 전처리 후 하수처리장 등에서의 병합처리 방식을 고려할 필요가 있었다.

광주 지역에서 aethalometer 측정 블랙 카본 입자의 질량흡수단면 평가 (Aethalometer-based Estimate of Mass Absorption Cross Section of Black Carbon Particles at an Urban Site of Gwangju)

  • 박승식;유근혜;이상일;배민석
    • 한국대기환경학회지
    • /
    • 제34권5호
    • /
    • pp.727-734
    • /
    • 2018
  • In this study, real-time absorption coefficients of carbonaceous species in $PM_{2.5}$ was observed using a dual-spot 7-wavelength Aethalometer between November 1, 2016 and December 31, 2017 at an urban site of Gwangju. In addition, 24-hr integrated $PM_{2.5}$ samples were simultaneously collected at the same site and analyzed for organic carbon and elemental carbon (OC and EC) using the thermal-optical transmittance protocol. A main objective of this study was to estimate mass absorption cross section (MAC) values of black carbon (BC) particles at the study site using the linear regression between aethalometer-based absorption coefficient and filter-based EC concentration. BC particles observed at 880 nm is mainly emitted from combustion of fossil fuels, and their concentration is typically reported as equivalent BC concentration (eBC). eBC concentration calculated using MAC value of $7.77m^2/g$ at wavelength of 880 nm, which was proposed by a manufacturer, ranged from 0.3 to $7.4{\mu}g/m^3$ with an average value of $1.9{\pm}1.2{\mu}g/m^3$, accounting for 7.3% (1.5~20.9%) of $PM_{2.5}$. The relationship between aerosol absorption coefficients at 880 nm and EC concentrations provided BC MAC value of $15.2m^2/g$, ranging from 11.4 to $16.2m^2/g$. The eBC concentrations calculated using the estimated MAC of $15.2m^2/g$ were significantly lower than those reported originally from aethalometer, and ranged from 0.2 to $3.8{\mu}g/m^3$, with an average of $1.0{\pm}0.6{\mu}g/m^3$, accounting for 3.7% of $PM_{2.5}$ (0.8~10.7%). Result from this study suggests that if the MAC value recommended by the manufacturer is applied to calculate the equivalent BC concentration and radiative forcing due to BC absorption, they would result in significant errors, implying investigation of an unique MAC value of BC particles at a study site.

화장품에 함유된 미량의 프탈레이트 함량을 정확히 분석하기 위한 가스크로마토그래피-질량분석 시험법 및 그 시험법의 유효성 (Accurate Analysis of Trace Phthalates and Method Validation in Cosmetics using Gas Chromatography with Mass Spectrometric Detection)

  • 김민기;정혜진;조준철
    • 대한화장품학회지
    • /
    • 제38권1호
    • /
    • pp.33-41
    • /
    • 2012
  • 네일락카와 헤어스프레이 같은 화장품에 존재하는 미량의 프탈레이트를 정량분석하기 위하여, 가스크로마토그래피와 질량분석기를 사용한 효과적이면서 환경친화적인 분석방법을 개발하였다. 이들 화장품들은 다량의 유기용매를 함유되어 프탈레이트를 분석하기 위하여 널리 사용되는 시료의 클린업 방법이 적합하지 않았다. 더군다나 미량의 프탈레이트 분석시에는 실험과정 중에서의 오염으로 인해 실제보다 높은 분석값을 산출하게 되는 경우가 매우 많다. 이에 정확한 함량분석 및 이차오염을 방지하기 위해 유기용매를 사용하여 시료를 직접 희석하는 시료 전처리를 적용하였다. 이 분석방법은 높은 정확성, 분석감도, 그리고 시료전처리를 간략히 할 수 있는 이점을 가진다. 화장품에서의 검출되는 빈도가 높고, 사람과 동물에 영향을 미치는 환경호르몬으로 보고되는 dibutyl phthalate (DBP)와 di (2-ethylhexyl) phthalate (DEHP) 두 종의 프탈레이트를 분석대상으로 선정하였다. 정량시 그 정확도 향상을 위해서 내부표준물질로 두 물질의 중수소치환체인 DBP-$d_4$,와 DEHP-$d_4$를 사용하였다. 시험법의 유효화를 시행한 결과 본 시험법이 ppm 농도의 프탈레이트 정량분석에 적합함을 확인하였으며, 네일락카와 헤어스프레이 제품에 약 $25{\mu}g/g$의 농도로 표준물질을 첨가하여 분석한 회수율은 95 - 106.1 % 범위였고, % 상대표준편차 값은 3.9 % 이하였다.

가스크로마토그래피/질량분석기를 이용한 약물의 확인 및 간이 정량분석 프로그램 개발 (Development of Rapid and Simple Drug Identification and Semi Quantitative Analytical Program by Gas Chromatography-Mass Spectrometry)

  • 김은미;한은영;홍효정;정수진;최상길;이종숙;정진미;염혜선;이한선;이상기
    • 약학회지
    • /
    • 제55권2호
    • /
    • pp.106-115
    • /
    • 2011
  • Systematic toxicological analysis (STA) means the process for general unknown screening of drugs and toxic compounds in biological fluids. In order to establish STA, in previous study we investigated pattern of drugs & poisons in autopsy cases during 2007~2009 in Korea, and finally selected 62 drugs as target drugs for STA. In this study, rapid and simple drug identification and quantitative analytical program by gas chromatography-mass spectrometry(GC-MS) was developed. The in-house program, "DrugMan", consisted of modified chemstation data analysis menu and newly developed macro modules. Total 55 drugs among 62 target drugs were applied to this program, they were 14 antidepressants, 8 anti-histamines, 5 sedatives/hypnotics, 5 narcotic analgesics, 3 antipsychotic drugs, and etc. For calibration curves, fifty five drugs were divided into four groups of range considering their therapeutic or toxic concentrations in blood specimen, i.e. 0.05~1 mg/l, 0.1~1 mg/l, 0.1~5 mg/l or 0.5~10 mg/l. Standards spiked bloods were extracted by solid-phase extraction (SPE) with trimipramine-D3 as internal standard. Parameters such as retention times, 3 mass fragment ions, and calibration curves for each drug were registered to DrugMan. A series of identification, semi quantitation of target drugs and reporting the results were performed automatically. Calibration curves for most drugs were linear with correlation coefficients exceeding 0.98. Sensitivity rate of DrugMan was 0.90 (90%) for 55 drugs at the level of 0.5 mg/l. For standard spiked bloods at the level of 0.5 mg/l for 29 drugs, semi quantitative concentrations were ranged 0.36~0.64 mg/l by DrugMan. If more drugs are registered to database in DrugMan in further study, it will be useful tools for STA in forensic toxicology.

Tandem Mass Spectrometric Analysis for Disorders in Amino, Organic and Fatty Acid Metabolism : 2 Years of SCL Experience in Korea

  • Yoon, Hye-Ran;Lee, Kyung Ryul
    • 대한유전성대사질환학회지
    • /
    • 제3권1호
    • /
    • pp.86-93
    • /
    • 2003
  • Background : The SCL began screening of newborns and high risk group blood spots with tandem mass spectrometry (MS/MS) in April 2001. Our goal was to determine approximate prevalence of metabolic disorders, optimization of decision criteria for estimation of preventive effect with early diagnosis. This report describes the ongoing effort to identify more than 30 metabolic disorders by MS/MS in South Korea. Methods : Blood spot was collected from day 2 to 30 (mostly from day 2 to 10) after birth for newborn. Blood spot of high risk group was from the pediatric patients in NICU, developmental delay, mental retardation, strong family history of metabolic disorders. One punch (3.2 mm ID) of dried blood spots was extracted with $150{\mu}L$ of methanol containing isotopically labelled amino acids (AA) and acylcarnitines (AC) internal standards. Butanolic HCl was added and incubated at $65^{\circ}C$ for 15 min. The butylated extract was introduced into the inlet of MS/MS. Neutral loss of m/z 102 and parent ion mode of m/z 85 were set for the analyses of AA and AC, respectively. Diagnosis was confirmed by repeating acylcarnitine profile, urine organic acid and plasma amino acid analysis, direct enzyme assay, or molecular testing. Results : Approximately 31,000 neonates and children were screened and the estimated prevalence (newborn/high risk group), sensitivity, specificity and recall rate amounted to 1:2384/1:2066, 96.55%, 99.98%, and 0.73%, respectively. Confirmed 28 (0.09%) multiple metabolic disorders (newborn/high risk) were as follows; 13 amino acid disorders [classical PKU (3/4), BH4 deficient-hyperphenylalaninemia (0/1), Citrullinemia (1/0), Homocystinuria (0/2), Hypermethioninemia (0/1), Tyrosinemia (1/0)], 8 organic acidurias [Propionic aciduria (2/1), Methylmalonic aciduria (0/1), Isovaleric aciduria (1/1), 3-methylcrotonylglycineuria (1/0), Glutaric aciduria type1 (1/0)], 7 fatty acid oxidation disorders [LCHAD def. (2/2), Mitochondrial TFP def. (0/1), VLCAD def. (1/0), LC3KT def. (0/1). Conclnsion : The relatively normal development of 10 patients with metabolic disorders among newborns (except for the expired) demonstrates the usefulness of newborn screening by MS/MS for early diagnosis and medical intervention. However, close coordination between the MS/MS screening laboratory and the metabolic clinic/biochmical geneticists is needed to determine proper decision of screening parameters, confirmation diagnosis, follow-up scheme and additional tests.

  • PDF

3성분계 시멘트를 활용한 실 대형 지하구조물의 매스 콘크리트 수화 발열 특성 및 균열 저항성 평가 (Evaluation of Hydration Heat Properties of Mass Concrete and Crack Resistance Performance in Practical Large Underground Structures Using Ternary Blended Cement)

  • 최연왕;오성록;이재남
    • 한국건설순환자원학회논문집
    • /
    • 제7권1호
    • /
    • pp.82-91
    • /
    • 2019
  • 본 연구에서는 실 대형 지하구조물의 매스 콘크리트의 수화 발열 특성 및 균열 저항성을 평가하기 위하여 실 구조물 내부의 온도이력 및 열 특성을 고려한 해석을 실시하였다. 해석 결과는 실측값과 비교를 통하여 해석의 신뢰성을 검증하였으며, 균열에 대한 저항성을 평가하였다. 실 구조물의 온도 측정 결과, 슬래브의 단열 온도 상승 계수 K 및 ${\alpha}$$35.1^{\circ}C$와 0.72이었으며, 벽체는 $29.3^{\circ}C$와 0.67로 분석되었다. 분석된 단열온도상승계수 및 현장조건을 적용한 수화열 해석 결과 실측값과 상관계수(r)는 각각 0.95 및 0.98로 나타났다. 슬래브 및 벽체의 균열 저항성을 평가한 결과 슬래브 및 벽체의 최소 균열지수는 각각 1.22 및 1.20으로 나타나 현장 관리기준을 만족하는 것으로 나타났다.

Bioactive lipids in gintonin-enriched fraction from ginseng

  • Cho, Hee-Jung;Choi, Sun-Hye;Kim, Hyeon-Joong;Lee, Byung-Hwan;Rhim, Hyewon;Kim, Hyoung-Chun;Hwang, Sung-Hee;Nah, Seung-Yeol
    • Journal of Ginseng Research
    • /
    • 제43권2호
    • /
    • pp.209-217
    • /
    • 2019
  • Background: Ginseng is a traditional herbal medicine for human health. Ginseng contains a bioactive ligand named gintonin. The active ingredient of gintonin is lysophosphatidic acid C18:2 (LPA C18:2). We previously developed a method for gintonin-enriched fraction (GEF) preparation to mass-produce gintonin from ginseng. However, previous studies did not show the presence of other bioactive lipids besides LPAs. The aim of this study was to quantify the fatty acids, lysophospholipids (LPLs), and phospholipids (PLs) besides LPAs in GEF. Methods: We prepared GEF from white ginseng. We used gas chromatography-mass spectrometry for fatty acid analysis and liquid chromatography-tandem mass spectrometry for PL analysis, and quantified the fatty acids, LPLs, and PLs in GEF using respective standards. We examined the effect of GEF on insulin secretion in INS-1 cells. Results: GEF contains about 7.5% linoleic (C18:2), 2.8% palmitic (C16:0), and 1.5% oleic acids (C18:1). GEF contains about 0.2% LPA C18:2, 0.06% LPA C16:0, and 0.02% LPA C18:1. GEF contains 0.08% lysophosphatidylcholine, 0.03% lysophosphatidylethanolamine, and 0.13% lysophosphatidylinositols. GEF also contains about 1% phosphatidic acid (PA) 16:0-18:2, 0.5% PA 18:2-18:2, and 0.2% PA 16:0-18:1. GEFmediated insulin secretion was not blocked by LPA receptor antagonist. Conclusion: We determined four characteristics of GEF through lipid analysis and insulin secretion. First, GEF contains a large amount of linoleic acid (C18:2), PA 16:0-18:2, and LPA C18:2 compared with other lipids. Second, the main fatty acid component of LPLs and PLs is linoleic acid (C18:2). Third, GEF stimulates insulin secretion not through LPA receptors. Finally, GEF contains bioactive lipids besides LPAs.

반응셀 유도결합플라스마 질량분석분석기를 이용한 칼슘 동위원소비율의 측정과 동위원소희석법의 적용 (Application of Dynamic Reaction Cell - Inductively Coupled Plasma Mass Spectrometry for the Determination of Calcium by Isotope Dilution Method)

  • 서정기;임용현;황의진;이상학
    • 분석과학
    • /
    • 제15권5호
    • /
    • pp.417-426
    • /
    • 2002
  • 반응셀이 장치된 유도결합플라스마 사중극자 질량분석기를 이용하여 자연적으로 존재하는 6개의 칼슘 동위원소의 검출특성에 관한 연구를 수행하였다. 동적반응셀 (dynamic reaction cell, DRC)장치를 이용한 실험에서 최적의 신호 대 잡음비를 얻기 위한 실험조건을 조사하였다. 본 실험을 통해서 반응기체로서 0.7 mL/min의 $NH_3$를 사용하고 rejection parameter (RPq)값을 0.6으로 사용함으로써, Ca의 질량위치인 m/z 40, 42, 43, 44, 46 그리고 m/z 48의 위치에서 잠재적인 간섭이온인 $Ar^+$, ${CO_2}^+$, ${NO_2}^+$, $CNO^+$ 등이 효과적으로 제거됨을 확인하였다. 검출한계는 동위원소 $^{40}Ca$, $^{42}Ca$, $^{43}Ca$, $^{44}Ca$, 및 $^{48}Ca$에 대해서 각각 1, 29, 169, 34, and 15 pg/g으로 얻을 수 있었다. 이러한 실험조건 하에서 국제비교분석을 위해서 영국의 LGC (Laboratory of the Government Chemistry, Queens Road, Teddington, England)로부터 공급된 합성식품분해물질 중의 Ca을 동위원소희석법을 적용하여 분석하였다. 동위원소희석법에 의한 측정의 불확도는 ISO/GUM과 EURACHEM지침서에 따라 평가하였다. 측정된 시료중의 Ca의 농도와 불확도는 ($66.4{\pm}1.2$) mg/kg이었다. 또한 본 실험방법의 유효성을 확인하기 위해 농도가 인증된 표준시료 NRCC (National Research Council of Canada)의 SLRS-3 (riverine water CRM)과 NIST (National Institute of Science and Technology)의 SRM1643d (trace element in water)를 분석하였다.