• Title/Summary/Keyword: Mass output

Search Result 380, Processing Time 0.033 seconds

Position Control of Chained Multiple Mass-Spring-Damper Systems - Adaptive Output Feedback Control Approaches

  • S. S. Ge;L. Huang;Lee, T. H.
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.2
    • /
    • pp.144-155
    • /
    • 2004
  • This paper addresses the issue of position control of a chain of multiple mass-spring-damper (CMMSD) units which can be found in many physical systems. The dynamic model of a CMMSD system with any degrees of freedom is expressed in a closed-form for the convenience of the controller design. Backstepping and model reference adaptive control (MRAC) approaches are then used to develop two adaptive output feedback controllers to control the position of a CMMSD system. The proposed controllers rely on the measurements of the input (force) and the output (position of the mass unit at the end of the chain) of the system without the knowledge of its parameters and internal states. Simulations are used to verify the effectiveness of the controllers

Real-Time Haptic Rendering for Multi-contact Interaction with Virtual Environment (가상현실을 위한 다중 접촉 실시간 햅틱 랜더링)

  • Lee, Kyung-No;Lee, Doo-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.7
    • /
    • pp.663-671
    • /
    • 2008
  • This paper presents a real-time haptic rendering method for multi-contact interaction with virtual environments. Haptic systems often employ physics-based deformation models such as finite-element models and mass-spring models which demand heavy computational overhead. The haptic system can be designed to have two sampling times, T and JT, for the haptic loop and the graphic loop, respectively. A multi-rate output-estimation with an exponential forgetting factor is proposed to implement real-time haptic rendering for the haptic systems with two sampling rates. The computational burden of the output-estimation increases rapidly as the number of contact points increases. To reduce the computation of the estimation, the multi-rate output-estimation with reduced parameters is developed in this paper. Performance of the new output-estimation with reduced parameters is compared with the original output-estimation with full parameters and an exponential forgetting factor. Estimated outputs are computed from the estimated input-output model at a high rate, and trace the analytical outputs computed from the deformation model. The performance is demonstrated by simulation with a linear tensor-mass model.

Experimental verification of leverage-type stiffness-controllable tuned mass damper using direct output feedback LQR control with time-delay compensation

  • Chu, Shih-Yu;Yeh, Shih-Wei;Lu, Lyan-Ywan;Peng, Chih-Hua
    • Earthquakes and Structures
    • /
    • v.12 no.4
    • /
    • pp.425-436
    • /
    • 2017
  • Vibration control using a tuned mass damper (TMD) is an effective technique that has been verified using analytical methods and experiments. It has been applied in mechanical, automotive, and structural applications. However, the damping of a TMD cannot be adjusted in real time. An excessive mass damper stroke may be introduced when the mass damper is subjected to a seismic excitation whose frequency content is within its operation range. The semi-active tuned mass damper (SATMD) has been proposed to solve this problem. The parameters of an SATMD can be adjusted in real time based on the measured structural responses and an appropriate control law. In this study, a stiffness-controllable TMD, called a leverage-type stiffness-controllable mass damper (LSCMD), is proposed and fabricated to verify its feasibility. The LSCMD contains a simple leverage mechanism and its stiffness can be altered by adjusting the pivot position. To determine the pivot position of the LSCMD in real time, a discrete-time direct output-feedback active control law that considers delay time is implemented. Moreover, an identification test for the transfer function of the pivot driving and control systems is proposed. The identification results demonstrate the target displacement can be achieved by the pivot displacement in 0-2 Hz range and the control delay time is about 0.1 s. A shaking-table test has been conducted to verify the theory and feasibility of the LSCMD. The comparisons of experimental and theoretical results of the LSCMD system show good consistency. It is shown that dynamic behavior of the LSCMD can be simulated correctly by the theoretical model and that the stiffness can be properly adjusted by the pivot position. Comparisons of experimental results of the LSCMD and passive TMD show the LSCMD with less demand on the mass damper stroke than that for the passive TMD.

Input and Output Budgets for Nitrogen of Paddy Field in South Korea

  • Jung, Goo-Bok;Hong, Seung-Chang;Kim, Min-Kyeong;Kim, Myung-Hyun;Choi, Soon-Kun;So, Kyu-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.1
    • /
    • pp.60-65
    • /
    • 2016
  • The main objective of this research was to estimate the total mass of nitrogen discharged from various sources in paddy field area of South Korea in 2010 and 2013. Input and output budgets for nitrogen were estimated by mass balance approach. The mass balance approach reduces the effect of flow variations, and the large scale approach minimizes local effects, resulting in easier and faster establishment of strategy for nonpoint pollution problems. Nitrogen inputs were chemical fertilizer, compost, atmospheric deposition, biological fixation, and agricultural water, while crop uptake, denitrification, volatilization, and infiltration were nitrogen outputs. The estimated total nitrogen inputs for paddy field in South Korea were $266,211ton\;yr^{-1}$, $260,729ton\;yr^{-1}$, while those of total nitrogen outputs were $168,463ton\;yr^{-1}$, $164,994ton\;yr^{-1}$ in 2010 and 2013, respectively. Annual amounts of potential nitrogen outflow from paddy field were $97,748ton\;yr^{-1}$, $95,735ton\;yr^{-1}$ in 2010 and 2013. Also, annual rate of potential nitrogen outflow were 36.7%, 36.7% in 2010 and 2013, respectively.

Comparison of the Characteristics of 16 Commercial Nebulizer/Compressor Combinations Used in Korea (국내 시판되는 16가지 연무기/압축기의 성능 평가)

  • Kim, Hyun Jung;Lee, Cho Ae;Hwang, Eun Kyung;Han, Man Young;Ann, Uk Sung;Cho, Young Min
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1235-1241
    • /
    • 2003
  • Purpose : We assessed the dynamic characteristics of 16 nebulizer/compressor combinations currently available in Korea. Methods : The 16 nebulizer/compressor combinations(Pariboy Type 38/Long life, Pariboy Type N/Long life, Pariboy Type N/Salter 8900, Pariboy Type N/LC, Devilbiss pulmoaid-LT/Hudson, Devilbiss pulmoaid/Hudson, Mesmed neb-300/Own, San-up 3040/Hudson, Midas(Basic)/Own, AirJolie 2/Hudson, Thomas 1127/Salter 8900, Noel NE-2000/Salter 8900, Omron CX3/Hudson, Chang Woo CWN-100/Salter 8900, Voyage/Mefar, Chang Woo ASI-Pro/Medel jet pulse) were evaluated in terms of particle size and mass output. In addition, we determined the effects of nebulizer fill volume on mass output. Results : Pariboy Type N/Long life has the highest respirable mass of 0.184 mg/min and Mesmed Neb-300/Own has the lowest 0.019 mg/min. Pariboy Type N/Long life has the highest mass output of 0.68 mg/min and the shortest mass median aerodynamic diameter(MMAD) of $3.76{\mu}m$. All combinations other than Pariboy Type N/Long life produced a MMAD of over $5{\mu}m$. MMAD over a 5 min nebulization ranged 3.76 to $9.83{\mu}m$. There were no significant effects of fill volume on mass output. Conclusion : We concluded that there is a wide variation in performance of nebulizer/compressor combinations. The characteristics of nebulizer/compressor combinations should be considered in selecting products.

Service commonality index in a service product (서비스 제품에서 서비스 공통성 지수)

  • Kim, Jun-Hong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.30 no.3
    • /
    • pp.82-88
    • /
    • 2007
  • Service engineering is a new discipline which aims at basically understanding of service and a concrete methodology using engineering approach for service design. In this paper is introduced the serviset graph [7] which is a comprehensive concept to represent service products, processes, and operation activities. The proposed concept is a degree of commonality index in a service product in order to deal with service mass customization using the input-output analysis in economic model.

Analytical and experimental investigation of stepped piezoelectric energy harvester

  • Deepesh, Upadrashta;Li, Xiangyang;Yang, Yaowen
    • Smart Structures and Systems
    • /
    • v.26 no.6
    • /
    • pp.681-692
    • /
    • 2020
  • Conventional Piezoelectric Energy Harvesters (CPEH) have been extensively studied for maximizing their electrical output through material selection, geometric and structural optimization, and adoption of efficient interface circuits. In this paper, the performance of Stepped Piezoelectric Energy Harvester (SPEH) under harmonic base excitation is studied analytically, numerically and experimentally. The motivation is to compare the energy harvesting performance of CPEH and SPEHs with the same characteristics (resonant frequency). The results of this study challenge the notion of achieving higher voltage and power output through incorporation of geometric discontinuities such as step sections in the harvester beams. A CPEH consists of substrate material with a patch of piezoelectric material bonded over it and a tip mass at the free end to tune the resonant frequency. A SPEH is designed by introducing a step section near the root of substrate beam to induce higher dynamic strain for maximizing the electrical output. The incorporation of step section reduces the stiffness and consequently, a lower tip mass is used with SPEH to match the resonant frequency to that of CPEH. Moreover, the electromechanical coupling coefficient, forcing function and damping are significantly influenced because of the inclusion of step section, which consequently affects harvester's output. Three different configurations of SPEHs characterized by the same resonant frequency as that of CPEH are designed and analyzed using linear electromechanical model and their performances are compared. The variation of strain on the harvester beams is obtained using finite element analysis. The prototypes of CPEH and SPEHs are fabricated and experimentally tested. It is shown that the power output from SPEHs is lower than the CPEH. When the prototypes with resonant frequencies in the range of 56-56.5 Hz are tested at 1 m/s2, three SPEHs generate power output of 482 μW, 424 μW and 228 μW when compared with 674 μW from CPEH. It is concluded that the advantage of increasing dynamic strain using step section is negated by increase in damping and decrease in forcing function. However, SPEHs show slightly better performance in terms of specific power and thus making them suitable for practical scenarios where the ratio of power to system mass is critical.

Performance and Emissions of a SI Engine Operated with LPG-DME Blended Fuel (LPG-DME 혼합연료를 사용하는 전기점화 기관의 성능 및 배기특성에 관한 연구)

  • Lee, Seok-Hwan;Oh, Seung-Mook;Kang, Kern-Yong;Choi, Won-Hak;Cha, Kyoung-Ok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.175-182
    • /
    • 2008
  • In this study, a spark ignition engine operated with LPG and DME blended fuel was studied experimentally. Performance and emissions characteristics of a LPG engine fuelled by LPG and DME blended fuel were examined. Results showed that stable engine operation was possible for a wide range of engine loads within 20% mass content of DME fuel. Also, engine output power within 10% mass content of DME fuel was comparable to pure LPG fuel operation. Exhaust emissions measurements showed that hydrocarbon and NOx were increased with the blended fuel at low engine speed. Engine output power was decreased and break specific fuel consumption (BSFC) was severely increased with the blended fuel since the energy content of DME was much lower than that of LPG. Considering the results of engine output power and exhaust emissions, the blended fuel within 20% mass content of DME could be used as an alternative fuel for LPG.

Performance Test and Flue Gas Characteristics of a 350 kW Wood Pellet Boiler (350 kW(300,000 kcal/h)급 우드 펠렛 보일러 운전 특성 및 성능 평가)

  • Kim, Jong-Jin;Kang, Sae-Byul
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.167-171
    • /
    • 2009
  • We conducted performance test of a 350 kW class wood pellet boiler installed at a dormitory whose total area is $1,354\;m^2$. The maximum heating capacity of the boiler is 350 kW(300,000 kcal/kg). The wood pellet boiler consists of 3 parts; boiler, hot water storage tank and wood pellet storage tank. In testing the boiler, we shut off hot water utility supply and open up floor heating water system in order to measure exact value of the heating output of the wood pellet boiler. To determine the efficiency and heating output of the wood pellet boiler, we measured mass flow rate of wood pellet, the lower heating value(LHV) of the wood pellet, mass flow rate and temperature of water for floor heating and so on. We measured the mass flow rate of fuel, wood pellet with respect to rotational speed of auger, wood pellet feeding screw. We also measured the flue gas concentration of the wood pellet boiler by using a gas analyser. The result shows that the efficiency of the wood pellet boiler is 80.6% based on lower heating value at 124 kW of heating output. At this condition, O2 concentration of the flue gas is 6.0%, CO and NOx concentrations are 85 and 102 ppm.

  • PDF

Water and Nutrient Mass Balances in Paddy Field with Groundwater Irrigation in Low-Rainfall Year (저강우연도 지하수 관개 필지논에서 수도재배기간 동안의 물질수지)

  • Hwang, H.S.;Jeon, J.H.;Kim, B.H.;Yoon, C.G.
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.4
    • /
    • pp.39-50
    • /
    • 2002
  • Field experiment was performed to investigate water and nutrient mass balances in paddy field with groundwater irrigation from May to October, 2001. The total water inflow was about 1,183mm in which rainfall, overflow from upstream paddy, and groundwater irrigation accounted for 43, 30, and 27%, respectively. Notice that the precipitation of the study period was less than the average annual precipitation. The total drainage was almost balanced with the inflow and more than half of it was occurred by surface drainage. From the nutrient mass balance analysis, the T-P output (17.56kg/ha) was estimated slightly lower than the input (20.90kg/ha) and the T-N output (130.41kg/ha) was slightly greater than the input(129.24kg/ha). However, the difference was within the expectation and the nutrient mass was thought to be balanced considering uncertainties in field experiment and other activities not included in the study such as algae and soil microorganisms. The surface discharge of nutrient, which was about 10% of total nutrient output, was mainly affected by fertilization and rainfall runoff. Therefore, prudent surface drainage plan might be necessary particularly for the fertilization period to prevent degradation of receiving water quality. The study was performed under abnormally low rainfall compared to the average annual rainfall record, and further monitoring in diverse rainfalls and irrigation methods is recommended to estimate nutrient behavior in the paddy field more reasonably.