• Title/Summary/Keyword: Mass load

Search Result 1,036, Processing Time 0.027 seconds

A Study on Cooling Characteristics of Ground Source Heat Pump with Variation of Water Switching and Refrigerant Switching Methods (수절환 및 냉매절환방식에 따른 지열히트펌프의 냉방특성에 관한 연구)

  • Cha, Dong-An;Kwon, Oh-Kyung;Park, Cha-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.605-611
    • /
    • 2012
  • The objective of this study is to investigate the influence of the cooling performance for a water-to-water 10 RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The cooling capacity and refrigerant mass flow rate of the heat pump increased with increasing ground heat source temperature. But COP of the heat pump decreased with increasing ground heat source temperature. As a result, the water switching method with counter flow, compared to a refrigerant switching method, improves the cooling capacity and COP by approximately 6~9% in average, respectively.

Performance Characteristics of Liquid-Cooling Heat Exchangers with MPCM Slurry Designed for Telecommunication Equipment (MPCM을 적용한 액냉형 냉각기의 성능 특성에 관한 연구)

  • Jeon, Jong-Ug;Kim, Yong-Chan;Choi, Jong-Min;Hyun, Dong-Soo;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.10
    • /
    • pp.710-717
    • /
    • 2007
  • Electric and telecommunication industries are constantly striving towards miniaturization of electronic devices. Miniaturization of chips creates extra space on PCBs that can be populated with additional components, which decreases the heat transfer surface area and generates very high heat flux. Even though an air-cooling technology for telecommunication equipment has been developed in accordance with rapid growth in electrical industry, it is confronted with the limitation of cooling capacity due to the rapid increase of heat density. In this study, liquid-cooling heat exchangers with MPCM slurries were designed and tested by varying geometry and operating conditions. The liquid-cooling heat exchangers with 4-paths showed higher cooling performance than the others. The cooling performance of liquid cooling heat exchanger with MPCM slurries was more enhanced than that of the air cooling system. It's performance was also slightly superior to that of the water cooling system at the inlet temperature of $19^{\circ}C$.

Experimental Study on Hydrodynamic Coefficients of Autonomous Underwater Glider Using Vertical Planar Motion Mechanism Test (VPMM 시험을 통한 무인 수중 글라이더 모형의 동유체력 계수 추정에 관한 연구)

  • Jung, Jin-Woo;Jeong, Jae-Hun;Kim, In-Gyu;Lee, Seung-Keon
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.119-125
    • /
    • 2014
  • A vertical planar motion mechanism(VPMM) test was used to increase the prediction accuracy for the maneuverability of an underwater glider model. To improve the accuracy of the linear hydrodynamic coefficients, the analysis techniques of a pure heave test and pure pitch test were developed and confirmed. In this study, the added mass and damping coefficient were measured using a VPMM test. The VPMM equipment provided pure heaving and pitching motions to the underwater glider model and acquired the forces and moments using load cells. As a result, the hydrodynamic coefficients of the underwater glider could be acquired after a Fourier analysis of the forces and moments. Finally, a motion control simulation was performed for the glider control system, and the results are presented.

Cycle Analysis and Experiment for a Small-Scale Organic Rankine Cycle Using a Partially Admitted Axial Turbine (부분분사 축류형 터빈을 이용한 소규모 유기랭킨 사이클의 실험 및 예측에 관한 연구)

  • Cho, Soo-Yong;Cho, Chong-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.5
    • /
    • pp.33-41
    • /
    • 2015
  • Organic Rankine cycle (ORC) has been used to generate electrical or mechanical power from low-grade thermal energy. Usually, this thermal energy is not supplied continuously at the constant thermal energy level. In order to optimally utilize fluctuating thermal energy, an axial-type turbine was applied to the expander of ORC and two supersonic nozzle were used to control the mass flow rate. Experiment was conducted with various turbine inlet temperatures (TIT) with the partial admission rate of 16.7 %. The tip diameter of rotor was to be 80 mm. In the cycle analysis, the output power of ORC was predicted with considering the load dissipating the output power produced from the ORC as well as the turbine efficiency. The predicted results showed the same trend as the experimental results, and the experimental results showed that the system efficiency of 2 % was obtained at the TIT of $100^{\circ}C$.

Topology Optimization of Inner-Wall Stiffener for Critical Buckling Loads of Cylindrical Containers (임계좌굴하중을 고려한 원통형 용기 내부 벽면 보강격자의 위상최적설계)

  • Youn Sung-Kie;Yeon Jeoung-Heum;Chang Su-Young;Yoo loon-Tae;Seo Yu-Deok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.3 s.234
    • /
    • pp.503-510
    • /
    • 2005
  • In this paper, the topology optimization of inner-wall stiffener of cylindrical containers for the use as a rocket fuel tank is presented. Such structures for space mission should have high stiffness against the buck]ins while their weight should be maintained low from the viewpoint of cost and performance. Therefore, in the present work the reciprocal of critical buckling load is adopted as an objective function and the total mass of stiffener is constrained to a prescribed value. Due to the restriction of computational resources a section of cylindrical container is topologically optimized and this result is repeated to obtain the full design. Also, for manufacturability the concept of periodic topology pattern in design domain is newly introduced. In the numerical examples, the results by the proposed approach are investigated and compared with those of isogrid design.

Advanced One-zone Heat Release Analysis for IDI Diesel Engine (IDI 디젤기관의 개선된 단일영역 열발생량 계산)

  • Kim Gyu-Bo;Jeon Choung-Hwan;Chang Young-Jun;Lee Suk-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.7
    • /
    • pp.1101-1110
    • /
    • 2004
  • An one-zone heat release analysis was applied to a 4 cylinder indirect injection diesel engine. The objective of the study is to calculate heat release accurately considering the effect of specific heat ratio. heat transfer and crevice model and to find out combustion characteristics of an indirect diesel engine considering the effect of the pressures in main and swirl chambers. Especially specific heat ratio indicating combustion characteristics is adapted. instead of that indicating matter properties, which has been used in former studies Moreover by adaption of blowby model, cylinder gas mass became accurately calculated. Therefore, with ideal gas equation, calculating cylinder gas temperature, it was found to affect heat transfer loss and heat release. Determining heat transfer constants $C_1$. $C_2$ as 0.6 respectively. the integrated gross heat release values were predicted well for the measured value at various engine speed, full load operating conditions. The curve of heat release rate was similar to SI engine rather than DI engine. That is originated from that swirl chamber reduce an instant combustion which occurs in DI engine due to ignition delay on early stage of combustion.

Measurements of Particulate Matters for the HSDI Diesel Engine with DOC using the ELPI (ELPI를 이용한 산화촉매 장착 고속 직접분사식 디젤엔진의 입자상물질 계측)

  • Choi, Byung-Chul;Jang, Se-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2245-2250
    • /
    • 2003
  • Particulate matters(PM) have bad effect on the health. We carried out measurements of diesel PM under $10{\mu}m$ diameter from a HSDI diesel engine with a diesel oxidation catalyst(DOC) by using the ELPI. This paper compares the two results of the smoke level and the PM level of masses and numbers. We also investigated the effect of the DOC. Under high speed and load, HSDI diesel engine exhausts much masses of particulate matters over 100nm diameter, and a number of PM from 7 to 100nm diameters at the same condition. DOC could reduce the total mass of the PM. However, the DOC could increase the number of ultra fine PM. Before light-off of the soot, the DOC absorb the PM and the DOC oxidize the PM after light-off temperature. The fine PM could be made during the oxidation. Therefore, the advanced DOC is needed to reduce the number of the fine PM.

  • PDF

Study of Air Clearing during Severe Transient of Nuclear Reactor Coolant System (원자로 사고 또는 과도상태시 공기방출현상에 대한 연구)

  • Bae Yoon Yeong;Kim Hwan Yeol;Song Chul-Hwa;Kim Hee Dong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.835-838
    • /
    • 2002
  • An experiment has been performed using a facility, which simulates the safety depressurization system (SDS) and in-containment refueling water storage tank (IRWST) of APR1400, an advanced PWR being developed in Korea, to investigate the dynamic load resulting from the blowdown of steam from a steam generator through a sparser. The influence of the key parameters, such as air mass, steam pressure, submergence, valve opening time, and pool temperature, on frequency and peak toads was investigated. The blowdown phenomenon was analyzed to find out the real cause of the initiation of bubble oscillation and discrepancy in frequencies between the experiment and calculation by conventional equation for bubble oscillation. The cause of significant damping was discussed and is presumed to be the highly tortuous flow path around bubble. The Rayleigh-Plesset equation, which is modified by introducing method of image, reasonably reproduces the bubble oscillation in a confined tank. Right after the completion of air discharge the steam discharge immediately follows and it condenses abruptly to provide low-pressure pocket. It may contribute to the negative maximum being greater than positive maximum. The subsequently discharging steam does not play as at the driving force anymore.

  • PDF

A Study on Fuzzy Control Simulator of Naturally Circulated Boiler (자연 순환식보일러의 퍼지제어 모사기 개발에 관한 연구)

  • Kim, Kwang-Sun;Kim, Sam-Un
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.543-554
    • /
    • 2000
  • The engineering equations, which have been used in many engineering companies, were employed for the dynamic modelling part in order to develop the naturally circulated boiler simulator. The fuzzy algorithm, which is similar to the algorithm of making decision by the human being, was developed for the boiler simulator controller and its simulated variables were compared with those of classical PID simulations to verify the stability and the effectiveness of fuzzy controller. The simulator is for the naturally circulated boiler and the main components are the furnace, the drum, the super heater, and the economizer. The combustion and thermal radiation dominant equations were used within the furnace and the mass conservation and the energy rate balance equations were employed for the drum part. The heat transfer rates were calculated using the logarithmic mean temperature differences both for the super heater and for the economizer. The simulations are very useful to understand the boiler operations and the engineering design of the main components. The main program was developed under the PC window condition by linking the fuzzy controller to the main boiler program using the Visual C++ language. The various operational conditions such as the abrupt changes of load, the changes of water supply pipes and the diameter of drum were simulated.

Virtual Sensor Verification Using Neural Network Theory of the Quadruped Robot (보행로봇의 신경망 이론을 이용한 가상센서 검증)

  • Ko, Kwang-Jin;Kim, Wan-Soo;Yu, Seung-Nam;Han, Chang-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.11
    • /
    • pp.1326-1331
    • /
    • 2009
  • The sensor data measured by the legged robot are used to recognize the physical environment or information that controls the robot's posture. Therefore, a robot's ambulation can be advanced with the use of such sensing information. For the precise control of a robot, highly accurate sensor data are required, but most sensors are expensive and are exposed to excessive load operation in the field. The seriousness of these problems will be seen if the prototype's practicality and mass productivity, which are closely related to the unit cost of production and maintenance, will be considered. In this paper, the use of a virtual sensor technology was suggested to address the aforementioned problems, and various ways of applying the theory to a walking robot obtained through training with an actual sensor, and of various hardware information, were presented. Finally, the possibility of the replacement of the ground reaction force sensor of legged robot was verified.