• 제목/요약/키워드: Mass Flux

검색결과 916건 처리시간 0.026초

수평원관상의 LiBr-수용액에 수증기가 흡수될때의 열 및 물질전달 (Coupled Heat and Mass Transfer during the Absorption of Water Vapor into LiBr-H2O Liquid Solution Flowing down the Outside of the Horizontal Cylinder)

  • 이관수;서석청;김영인;박동규
    • 대한설비공학회지:설비저널
    • /
    • 제17권2호
    • /
    • pp.140-149
    • /
    • 1988
  • The problem of heat and mass transfer accompanying the absorption of water vapor into LiBr-$H_2O$ liquid solution flowing over the outside of the horizontal cylinder was theoretically studied to understand the absorption process occuring in the absorber of the absorption heat pump. Numerical results are presented for various quantities of interest relating to temperature, concentration, heat flux and mass flux. Also, the effects of mass flowrate, initial average velocity, and the radius of the cylinder were investigated.

  • PDF

Downward particle flux in the eastern Bransfield Strait, Antarctica

  • Kim, Dongseon;Kim, Dong-Yup;Jeonghee Shim;Kang, Young-Chul;Kim, Taerim
    • Journal of the korean society of oceanography
    • /
    • 제38권1호
    • /
    • pp.1-10
    • /
    • 2003
  • A time-series sediment trap was deployed at a depth of 1034 m in the eastern Bransfield Strait from December 25, 1998 to December 24, 1999. Particle fluxes showed large seasonal variation; about 99% of the annual total mass flux (49 g m/sup -2/) was collected during the austral summer and fall (January-March). Settling particles consisted primarily of biogenic silica, organic carbon, calcium carbonate, and lithogenic material. Biogenic silica and lithogenic material predominated settling particles, comprising 36% and 30% of the total mass flux, respectively, followed by organic carbon, 11% and calcium carbonate, merely 0.6%. The annual organic carbon flux was 5.4 g C m/sup -2/ at 1000 m in the eastern Bransfield Strait, which is greater than the central Strait flux. The relatively lower flux of organic carbon in the central Bransfield Strait may be caused by a stronger surface current in this region. Organic carbon flux estimates in the eastern Bransfield Strait are the highest in the Southern Ocean, perhaps because of the fast sinking of fecal pellets, which leads to less decomposition of organic material in the water column. Approximately 5.8% of the organic carbon produced on the surface in the eastern Bransfield Strait is exported down to 1000 m; this percentage exceeds the maximum EF/sub 1000/ values observed in the Atlantic and Southern Oceans. The eastern Bransfield Strait appears to be the most important site of organic carbon export to the deep sea in the Southern Ocean.

성층 데브리층에서의 강제대류 드라이아웃 열유속 (Forced Flow Dryout Heat Flux in a Stratified Debris Bed)

  • Cha, Jong-Hee;Chung, Moon-Ki;Jin, Yong-Suk
    • Nuclear Engineering and Technology
    • /
    • 제20권2호
    • /
    • pp.112-119
    • /
    • 1988
  • 이 연구의 목적은 가혹한 사고후 손상된 원자로심을 모의한 열이 발생하는 성충 데브리층에서의 강제대류 드라이아웃 열유속 자료를 실험 적으로 얻고자 한 것이다. 여 기서는 일정한 층의 깊이와 냉각재 유입온도 조건하에서 선정된 몇 가지 크기의 입자로 성층을 형성한 데브리층에서 주로 냉각재질량유속이 드라이아웃 열유속에 미치는 영향을 관찰하였다. 이 실험적 연구로부터 얻은 주요 결과는 다음과 같다 (1) 성층 데브리층에서의 드라이아웃 열유속은 질량유속의 증가와 더불어 증가하며 그 증가의 경향은 크기가 균일한 입자층에 대한 것과 유사하다. (2) 이론치와 실험치와의 비교에서 입자직경으로는 표면적 평균 직경을 사용하는 것이 적합하다.

  • PDF

오일러형 해빈류 모형의 파랑응력 비교 (Comparison of Wave Stresses in the Eulerian Nearshore Current Models)

  • 안경모;서경덕;천후섭
    • 한국해안·해양공학회논문집
    • /
    • 제29권6호
    • /
    • pp.350-362
    • /
    • 2017
  • 오일러형 해빈류 모형은 계산된 질량흐름에 파랑질량흐름이 포함되어 있지 않기 때문에 수치모의된 계산결과를 정점 관측결과와 직접 비교할 수 있다. 또한 포물선형 연직분포를 가진 연안류를 재현할 수 있음으로 인해 라그랑지형 해빈류 모형보다 장점이 있다. 그러나 오일러형 해빈류 모형에서 파랑에 의한 응력인 파랑응력이 해빈류 모형에 따라 형태가 달라, 서로 다른 계산 결과가 나타나게 된다. Newberger and Allen(2007)의 파랑응력은 연직방향으로 수심의 함수가 아닌 상수인 반면에 Chun(2012)의 파랑응력은 수심의 함수로 표현된다. 이러한 차이는 해빈류 계산 결과에 직접적인 영향을 미치고 있어 본 논문에서는 이들 파랑응력의 차이를 해석적으로 비교하였다. 각 파랑응력에 대한 해빈류 모형을 Hamilton et al.(2001)의 LSTF(Large-scale Sediment Transport Facility) 수리모형 실험에 적용하여 차이를 비교함으로써 파랑응력항의 차이에 따른 해빈류 계산 결과의 특성을 검토하였다.

평활관에서 이산화탄소의 증발열전달 특성에 관한 실험연구 (Experimental Study on Characteristics of Evaporation Heat Transfer of CO2 in a Smooth Tube)

  • 이상재;최준영;이재헌;권영철
    • 에너지공학
    • /
    • 제16권4호
    • /
    • pp.181-186
    • /
    • 2007
  • 본 연구에서는 이산화탄소의 증발열전달 특성을 이해하기 위해 질량유속, 열유속 기리고 포화온도를 변화시키면서 이산화탄소의 증발 열전달계수와 압력강하를 측정하였다. 질량유속과 열유속은 기존의 실험범위보다 크게 확장하여 내경 7.75 mm, 길이 5.0 m의 수평관에서 실험하였다. 실험장치는 시험부, 전원공급기, 히터, 칠러, 기어펌프, 유량계, 계측시스템 등으로 구성되었다. 건도가 증가할수록 증발 열전달계수는 감소하였으며, 이산화탄소의 증발 열전달계수는 질량유속보다 열유속에 더 민감함을 확인하였다. 또한 주어진 열유속과 포화온도에 따라 증발 열전달계수의 급격한 감소가 다르게 관찰되었다. 압력강하는 질량유속 증가에 대해 선형적인 증가를 보였지만 열유속 증가에 대한 압력강하의 증가효과가 크지 않았다.

하이브리드 로켓에서의 압력에 따른 연소특성에 관한 연구 (A Study on Combustion Characteristic with Chamber Pressure in Hybrid Rocket)

  • 조정태;김기훈;이정표;김학철;박성우;박준형;한희수;황재웅;문희장;성홍계;김진곤
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.243-246
    • /
    • 2008
  • 하이브리드 연소에서 연소실 압력에 따른 고체 연료의 연소 특성을 실험적으로 연구하였다. 본 연구는 낮은 산화제 평균 질량 유속구간에서 고체 연료 후퇴율이 산화제 유속 뿐만 아니라 연소실 압력에 영향이 있는지 실험적으로 확인하였다. 연료로 Poly-Ethylene과 산화제로 GOX를 이용하였으며, 동일 산화제 유속에서 연소실 압력 변화는 6mm,9mm의 노즐 목 직경으로 사용하였다. 낮은 산화제 질량유속구간에서 고체연료 후퇴율이 산화제 유속뿐만 아니라 압력에 의한 영향이 있고, 동일 산화제 유속에서 압력이 증가 할수록 후퇴율이 증가함을 확인 하였다.

  • PDF

알루미늄 다채널 평판관 증발기 내 냉매분배 (Distribution of Air-Water Two-Phase Flow in a Flat Tube Heat Exchanger)

  • 김내현;박태균;한성필;이응렬
    • 설비공학논문집
    • /
    • 제18권10호
    • /
    • pp.800-810
    • /
    • 2006
  • The R-134a flow distribution is experimentally studied for a heat exchanger composed of round headers and 10 flat tubes. The effects of tube protrusion depth as well as mass flux, and quality are investigated, and the results are compared with the previous air-water results. The flow at the header inlet is stratified. For the downward flow configuration, the liquid distribution improves as the protrusion depth or the mass flux increases, or the quality decreases. For the upward configuration, the liquid distribution improves as the mass flux or quality decreases. The protrusion depth has minimal effect. For the downward configuration. the effect of quality on liquid distribution is significantly affected by the flow regime at the header inlet. For the stratified inlet flow, the liquid is forced to rear part of the header as the quality decreases. However, for the annular inlet flow, the liquid was forced to the frontal part of the header as the quality decreased. For the upward flow, the effect of the mass flux or quality on liquid distribution of the stratified inlet flow is opposite to that of the annular inlet flow. The high gas velocity of the annular flow may be responsible for the trend. Generally, the liquid distribution of the stratified inlet flow is better than that of the annular inlet flow. Possible explanation is provided from the flow visualization results.

막냉각량 및 작동점 변화가 액체로켓 칼로리미터의 열유속에 미치는 영향 (Parametric Study on Heat Flux Characteristics of a Sub-scale Calorimeter)

  • 김종규;이광진;서성현;한영민;최환석;조원국
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.346-350
    • /
    • 2005
  • 연소압 50bar 이상의 연소조건에서 반복 사용이 가능하도록 제작된 물냉각형 칼로리미터에서 막냉각량 및 작동점의 변화 시 열유속의 특성을 알아보았다. 분사기 헤드와 칼로리미터 사이에 12개의 오리피스를 갖는 막냉각 링이 삽입된다. 칼로리미터는 연소실부와 노즐부로 구성되어 있으며, 총 19개의 냉각 채널로 구성되어 있다. 설계점 연소시험 시 막냉각량이 주 연료의 10.5% 유량일 때, 막냉각량이 없는 경우보다 노즐목에서의 최대 열유속은 약 30% 감소되었고, 막냉각량이 없는 경우, 탈설계점(OD3)이 설계점에 비해 노즐목에서의 최대 열유속이 약 31% 증가 하였다.

  • PDF

미세 수평 사각 유로에서의 비등 열전달에 대한 실험적 연구 (An Experimental Study on Flow Boiling Heat Transfer within Horizontal Rectangular Channels with Small Heights)

  • 이상용;이한주
    • 대한기계학회논문집B
    • /
    • 제25권9호
    • /
    • pp.1209-1218
    • /
    • 2001
  • The present paper proposes a new correlation for the flow boiling heat transfer coefficients in the low flow rate condition (Re(sub)LF$\leq$200) within horizontal rectangular channels with small gaps (heights). The gap between the upper and the lower plates of each channel ranges from 0.4 to 2mm while the channel width being fixed to 20mm. Refrigerant 113 was used as the test fluid. The mass flux ranges from 50 to 200kg/㎡s and the channel walls were uniformly heated with the heat flux range of 3-15kW/㎡. The quality range covers from 0.19 to 0.76 and the flow pattern is considered to be annular. The measured heat transfer coefficients increase with the mass flux and the local quality; however the effect of the heat flux appears to be minor. At the low mass flux condition, which is more likely with the smaller gap size, the heat transfer is primarily controlled by the liquid film thickness. The proposed F factor for the heat transfer coefficient in the range of Re(sub)LF$\leq$200 well represents the experimental data within the deviation of $\pm$20%. The Kandlikars flow boiling correlation covers the higher flow-rate range(Re(sub)LF>200) within the deviation of $\pm$20%.

수평미세관내 R-290의 비등열전달 특성 (Boiling Heat Transfer Characteristics of R-290 in Horizontal Smooth Minichannel)

  • 최광일;;오종택
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.906-914
    • /
    • 2006
  • The present paper dealt with an experimental study of boiling heat transfer characteristics of R-290. Pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal smooth minichannel were obtained with inner tube diameter of 3.0 mm and length of 2,000 mm. The direct electric heating method was applied for supplying a heat to the refrigerant uniformly. The experiments were conducted with R-290 purity of 99.99%, at saturation temperature of 0 to $10^{\circ}C$, a mass flux range of $50{\sim}250kg/m^2s$, and a heat flux range of $5{\sim}20kW/m^2$. The heat transfer coefficients of R-290 increased with increasing mass flux and saturation temperature, wherein the effect of mass flux was higher than that of the saturation temperature. Heat flux has a low effect on the increasing of heat transfer coefficient. The heat transfer coefficient was compared with six existing heat transfer coefficient correlations. The Zhang et al.'s correlation (2004) gave the best prediction of heat transfer coefficient. A new correlation to predict the two-phase flow heat transfer coefficient was developed based on the Chen correlation. The new correlation predicted the experimental data well with a mean deviation of 11.78% and average deviation of -0.07%.