• Title/Summary/Keyword: Mass Flux

Search Result 916, Processing Time 0.025 seconds

Coupled Heat and Mass Transfer during the Absorption of Water Vapor into LiBr-H2O Liquid Solution Flowing down the Outside of the Horizontal Cylinder (수평원관상의 LiBr-수용액에 수증기가 흡수될때의 열 및 물질전달)

  • Lee, K.S.;Seo, S.C.;Kim, Y.I.;Park, D.K.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.2
    • /
    • pp.140-149
    • /
    • 1988
  • The problem of heat and mass transfer accompanying the absorption of water vapor into LiBr-$H_2O$ liquid solution flowing over the outside of the horizontal cylinder was theoretically studied to understand the absorption process occuring in the absorber of the absorption heat pump. Numerical results are presented for various quantities of interest relating to temperature, concentration, heat flux and mass flux. Also, the effects of mass flowrate, initial average velocity, and the radius of the cylinder were investigated.

  • PDF

Downward particle flux in the eastern Bransfield Strait, Antarctica

  • Kim, Dongseon;Kim, Dong-Yup;Jeonghee Shim;Kang, Young-Chul;Kim, Taerim
    • Journal of the korean society of oceanography
    • /
    • v.38 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • A time-series sediment trap was deployed at a depth of 1034 m in the eastern Bransfield Strait from December 25, 1998 to December 24, 1999. Particle fluxes showed large seasonal variation; about 99% of the annual total mass flux (49 g m/sup -2/) was collected during the austral summer and fall (January-March). Settling particles consisted primarily of biogenic silica, organic carbon, calcium carbonate, and lithogenic material. Biogenic silica and lithogenic material predominated settling particles, comprising 36% and 30% of the total mass flux, respectively, followed by organic carbon, 11% and calcium carbonate, merely 0.6%. The annual organic carbon flux was 5.4 g C m/sup -2/ at 1000 m in the eastern Bransfield Strait, which is greater than the central Strait flux. The relatively lower flux of organic carbon in the central Bransfield Strait may be caused by a stronger surface current in this region. Organic carbon flux estimates in the eastern Bransfield Strait are the highest in the Southern Ocean, perhaps because of the fast sinking of fecal pellets, which leads to less decomposition of organic material in the water column. Approximately 5.8% of the organic carbon produced on the surface in the eastern Bransfield Strait is exported down to 1000 m; this percentage exceeds the maximum EF/sub 1000/ values observed in the Atlantic and Southern Oceans. The eastern Bransfield Strait appears to be the most important site of organic carbon export to the deep sea in the Southern Ocean.

Forced Flow Dryout Heat Flux in a Stratified Debris Bed (성층 데브리층에서의 강제대류 드라이아웃 열유속)

  • Cha, Jong-Hee;Chung, Moon-Ki;Jin, Yong-Suk
    • Nuclear Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.112-119
    • /
    • 1988
  • The purpose of this work is to obtain the experimental data for the forced How dryout heat flux in a heat generating stratified debris bed which simulates the degraded nuclear reactor core after severe accident. The present observations were mainly focused on the effect of coolant mass flux on the dryout heat flux in the stratified debris bed which consists of several layers with selected particle sizes under constant bed depth and temperature of inlet coolant flow conditions. The following results were obtained from this experimental work: (1) The dryout heat flux in the stratified debris bed increases with increase of upward forcing mass flux of coolant. The similar trend of increase rate of dryout heat flux in the stratified bed was observed in the uniform particle size bed. (2) For the comparison of theoretical values and experimental data, the use of surface area mean diameter as a particle diameter was suitable for the calculation of dryout heat flux.

  • PDF

Comparison of Wave Stresses in the Eulerian Nearshore Current Models (오일러형 해빈류 모형의 파랑응력 비교)

  • Ahn, Kyungmo;Suh, Kyung-Duck;Chun, Hwusub
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.6
    • /
    • pp.350-362
    • /
    • 2017
  • The Eulerian nearshore current model is more advantageous than the Lagrangian model in the way that numerical results from the Eulerian model can be directly compared with the measurements by the stationary equipment. It is because the wave mass flux is not included in the computed mass flux of Euleran nearshore current model. In addition, the Eulerian model can simulate the longshore currents with depth varying parabolic profile. However, the numerical models proposed by different researcher have different forms of the wave stress terms. For example, wave stresses in Newberger and Allen's (2007) model is constant over the depth, while those of Chun (2012) are vertically distributed. In the present study, these wave stress terms were compared against Hamilton et al.'s (2001) laboratory experiments to see the effects of different wave stress terms performed on the computation of nearshore currents.

Experimental Study on Characteristics of Evaporation Heat Transfer of CO2 in a Smooth Tube (평활관에서 이산화탄소의 증발열전달 특성에 관한 실험연구)

  • Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Journal of Energy Engineering
    • /
    • v.16 no.4
    • /
    • pp.181-186
    • /
    • 2007
  • In order to investigate the heat transfer coefficient and pressure drop during evaporation of $CO_2$, basic experiment on the evaporation heat transfer characteristics in a horizontal smooth tube was performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes ($200{\sim}1200\;kg/m^2s$), heat fluxes ($10{\sim}80\;kW/m^2$) and saturation temperatures ($-5{\sim}5^{\circ}C$). With the increase of quality, the evaporation heat transfer coefficient decreased. With the increase of heat flux, the evaporation heat transfer coefficient increased. Significantly change of the heat transfer coefficient was observed at any heat flux and mass flux. With the increase of saturation temperature, the heat transfer coefficient increased. Pressure drop increased with the increase of mass flux and the decrease of saturation temperature.

A Study on Combustion Characteristic with Chamber Pressure in Hybrid Rocket (하이브리드 로켓에서의 압력에 따른 연소특성에 관한 연구)

  • Cho, Jung-Tae;Kim, Gi-Hun;Lee, Jung-Pyo;Kim, Hak-Chul;Park, Seon-Woo;Park, Joon-Hyng;Han, Hee-Soo;Hwang, Jae-Woong;Moon, Hee-Jang;Sung, Hong-Gye;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.243-246
    • /
    • 2008
  • The combustion characteristic of solid fuel with chamber pressure were experimentally studied in hybrid combustion. This paper was experimental confirmed whether solid fuel affected not only oxidizer mass flux but also chamber pressure. Poly-Ethylene(PE) was used as fuel, GOX was used as oxidizer. Chamber pressure was controled by nozzle throat diameter 6mm and 9mm. In low oxidizer mass flux, solid fuel regression rate was affected not only oxidizer mass flux but also chamber pressure. As well, the regression rate increase as chamber pressure increase with same oxidizer mass flux.

  • PDF

Distribution of Air-Water Two-Phase Flow in a Flat Tube Heat Exchanger (알루미늄 다채널 평판관 증발기 내 냉매분배)

  • Kim Nae-Hyun;Park Tae-Gyun;Han Sung-Pil;Lee Eung-Ryul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.800-810
    • /
    • 2006
  • The R-134a flow distribution is experimentally studied for a heat exchanger composed of round headers and 10 flat tubes. The effects of tube protrusion depth as well as mass flux, and quality are investigated, and the results are compared with the previous air-water results. The flow at the header inlet is stratified. For the downward flow configuration, the liquid distribution improves as the protrusion depth or the mass flux increases, or the quality decreases. For the upward configuration, the liquid distribution improves as the mass flux or quality decreases. The protrusion depth has minimal effect. For the downward configuration. the effect of quality on liquid distribution is significantly affected by the flow regime at the header inlet. For the stratified inlet flow, the liquid is forced to rear part of the header as the quality decreases. However, for the annular inlet flow, the liquid was forced to the frontal part of the header as the quality decreased. For the upward flow, the effect of the mass flux or quality on liquid distribution of the stratified inlet flow is opposite to that of the annular inlet flow. The high gas velocity of the annular flow may be responsible for the trend. Generally, the liquid distribution of the stratified inlet flow is better than that of the annular inlet flow. Possible explanation is provided from the flow visualization results.

Parametric Study on Heat Flux Characteristics of a Sub-scale Calorimeter (막냉각량 및 작동점 변화가 액체로켓 칼로리미터의 열유속에 미치는 영향)

  • Kim Jong-Gyu;Lee Kwang-Jin;Seo Seong-Hyeon;Han Yeoung-Min;Choi Hwan-Seok;Cho Won-Kook
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.346-350
    • /
    • 2005
  • Effects of the changes of a film cooling mass flow rate and operating conditions on the heat flux characteristics of the subscale calorimeter were studied. A film cooling ring with twelve orifices is inserted between the injector head and the calorimeter. The calorimeter is composed of nineteen cooling channels. When a mass flow rate of film cooling is 10.5 % of a main fuel mass flow rate, maximum heat flux at the nozzle throat is decreased by 30% compared to that without film cooling. In the OD3(of-design point) test result, maximum heat flux at the nozzle throat is increased by 31% compared to that of the DP(design point) test when a film cooling flow rate is zero.

  • PDF

An Experimental Study on Flow Boiling Heat Transfer within Horizontal Rectangular Channels with Small Heights (미세 수평 사각 유로에서의 비등 열전달에 대한 실험적 연구)

  • Lee, Sang-Yong;Lee, Han-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1209-1218
    • /
    • 2001
  • The present paper proposes a new correlation for the flow boiling heat transfer coefficients in the low flow rate condition (Re(sub)LF$\leq$200) within horizontal rectangular channels with small gaps (heights). The gap between the upper and the lower plates of each channel ranges from 0.4 to 2mm while the channel width being fixed to 20mm. Refrigerant 113 was used as the test fluid. The mass flux ranges from 50 to 200kg/㎡s and the channel walls were uniformly heated with the heat flux range of 3-15kW/㎡. The quality range covers from 0.19 to 0.76 and the flow pattern is considered to be annular. The measured heat transfer coefficients increase with the mass flux and the local quality; however the effect of the heat flux appears to be minor. At the low mass flux condition, which is more likely with the smaller gap size, the heat transfer is primarily controlled by the liquid film thickness. The proposed F factor for the heat transfer coefficient in the range of Re(sub)LF$\leq$200 well represents the experimental data within the deviation of $\pm$20%. The Kandlikars flow boiling correlation covers the higher flow-rate range(Re(sub)LF>200) within the deviation of $\pm$20%.

Boiling Heat Transfer Characteristics of R-290 in Horizontal Smooth Minichannel (수평미세관내 R-290의 비등열전달 특성)

  • Choi, Kwang-Il;Pamitran, A.S.;Oh, Jong-Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.906-914
    • /
    • 2006
  • The present paper dealt with an experimental study of boiling heat transfer characteristics of R-290. Pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal smooth minichannel were obtained with inner tube diameter of 3.0 mm and length of 2,000 mm. The direct electric heating method was applied for supplying a heat to the refrigerant uniformly. The experiments were conducted with R-290 purity of 99.99%, at saturation temperature of 0 to $10^{\circ}C$, a mass flux range of $50{\sim}250kg/m^2s$, and a heat flux range of $5{\sim}20kW/m^2$. The heat transfer coefficients of R-290 increased with increasing mass flux and saturation temperature, wherein the effect of mass flux was higher than that of the saturation temperature. Heat flux has a low effect on the increasing of heat transfer coefficient. The heat transfer coefficient was compared with six existing heat transfer coefficient correlations. The Zhang et al.'s correlation (2004) gave the best prediction of heat transfer coefficient. A new correlation to predict the two-phase flow heat transfer coefficient was developed based on the Chen correlation. The new correlation predicted the experimental data well with a mean deviation of 11.78% and average deviation of -0.07%.