• Title/Summary/Keyword: Mass Balance

Search Result 930, Processing Time 0.03 seconds

A study on the motorcycle lear cowl injection molding by CAE analysis (CAE 해석을 이용한 오토바이 리어카울 사출성형에 관한 연구)

  • Sung, Si-Myung;Jung, Sang-Jun
    • Design & Manufacturing
    • /
    • v.13 no.4
    • /
    • pp.34-39
    • /
    • 2019
  • In this paper, in order to improve the formability and quality of the injection molded parts in the molds for molding the motorcycle rear cowl injection molded parts with different volumes at the same time, the flow of the molded parts is changed through the injection molding CAE analysis by changing the gate position, runner size and position. It is to find the optimum gate position, the diameter of the runner and the position where the balance is equal. The molded article formed by the optimization resulted in the uniformity of the molten resin at the same time at the corner of the product, thereby maintaining the flow balance favorable for mass production at lower injection pressure.

Approximate Response of a Non-linear Vibration Isolation System Using the Harmonic Balance Method (하모닉 밸런스법을 이용한 비선형 진동절연 시스템의 근사적 응답)

  • Lee, Gun-Myung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.124-129
    • /
    • 2018
  • A non-linear vibration isolation system which is composed of a non-linear spring and a linear damper was proposed in past research. When the support of the isolation system is excited harmonically, the response component of the isolation system mass at the excitation frequency has been calculated approximately using the harmonic balance method. The response was approximated by a single mode, and the result was compared with a numerical result which is assumed as an accurate one. Next, the response was approximated by two modes, and the result was compared with the former one.

A study on multi-cavity injection mold and molding elemental technology for plastic product of high precision tolerance (고정밀 플라스틱 제품 성형을 위한 다수 캐비티 사출금형 및 성형 요소기술에 관한 연구)

  • Jong-In Son;Chul-Ki Kim;Byeong-Uk Song
    • Design & Manufacturing
    • /
    • v.17 no.4
    • /
    • pp.57-62
    • /
    • 2023
  • As a representative method for mass production, a multi-cavity type mold capable of simultaneously molding products of the same shape can be applied. It has the advantage of improving the productivity from several times to several tens of times, but it may cause disadvantages which is the quality deviation with each cavity. This study, therefore, has tried to increase the cavity filling balance by using a melt flipper and a flow distance control part in the runner part of the mold. Along with this, the design and manufacturing of air vents during injection molding have been verified through experimental methods to achieve a higher level of multi-cavity filling balance and dimensional accuracy.

Effect of Aquatic Walking Exercise on Gait and Balance Parameters of Elderly Women (수중걷기운동이 여성노인의 보행 및 평형능력에 미치는 영향)

  • Kang, Ki-Joo;Lee, Joong-Sook;Yang, Jeong-Ok;Park, Joon-Sung;Han, Ki-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.1
    • /
    • pp.73-81
    • /
    • 2020
  • Objective: The purpose of this study is to analyze the effects of aquatic walking exercise on gait and balance parameters of elderly women. Method: 15 elderly people were recruited for this study (age: 73.20±5.19 yrs, height: 153.87±3.36 cm, mass: 60.33±5.73 kg). All variables were measured using Gaitview AFA-50. The variables were the heel contact time ratio, gait angle, and M/P change ratio for gait patterns and ENV, REC, RMS, Total Length, TLC, Sway velocity, and Length/ENV for balance abilities. A paired t-test and the Wilcoxon signed-rank test were carried out to verify the differences in the test scores after participating in the water walking program. The significance level for all statistical analyses was set to α=.05. Results: As for the changes in their walking function after the exercise, heel contact time ratio (p<.01) showed a statistical significance, while gait angle and M/P change ratio did not reveal statistically significant differences. In the test of balance ability on both feet and with eyes opened, statistical significance was found in ENV, REC, RMS, TLC (p<.01), and sway velocity (p<.05), while the test with eyes closed showed statistical significance in length/ENV as well as ENV, REC, RMS, sway velocity (p<.01) TLC, and total length (p<.05). As for the single-leg stance balance ability, ENV and REC revealed statistically significant differences. Conclusion: These results show that water walking is effective for improving the function of the ankle flexor muscles, providing stability to the ankle joint during walking and helping efficient walk. In addition, it is also expected to help prevent falls due to loss of balance by improving the stability of lower extremity muscles and trunk.

The Comparison of the Ability of Balance Performance between Abnormal Persons with Blindness or Deafness and Normal Persons (정상인과 시각 및 청각장애인의 사이의 균형수행력 차이에 관한 연구)

  • Lim, Chang-Hun
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.6
    • /
    • pp.5-10
    • /
    • 2007
  • Purpose: This study examined whether or not the balance performing ability of the disabled (blindness and deafness) is lower than normal people. Chronometry was used to compare the balance maintaining ability of blind and deaf subjects with that of normal subjects under the same conditions. Methods: In this study, balance foam, eye bandage, earplugs and headphones were used. The balance foam used in this study is smooth with slight elasticity and a convex upper side, 60cm wide, 15cm long and 9cm high. The eye bandage was used to artificially block the sight of the normal subjects, and the earplugs and headphones to block their hearing. Results: The mean time of the normal subjects standing with their eyes open, blindfolded and wearing ear plugs was 26.7, 19.8 and 28.7sec, respectively. The mean standing maintaining time for the blind and deaf subjects was 12.5 sec and 24.1 sec, respectively. The t-test result of the calculated mean time showed no significant difference (p>0.05) between the normal subjects and the normal subjects with their hearing blocked but there was a significant difference between the normal subjects with their hearing blocked and the deaf subjects (p>0.05). Conclusion: There was significance between the normal subjects and the normal subjects with their eyes blocked but there was no significant difference between the normal subjects with their eyes blocked and the blind subjects. Furthermore, there was a significant difference between the deaf and the normal subjects, which corresponds to the report showing that sight has a significant influence on balance.

  • PDF

Analysis of Kinematic Factors between Success and Failure of Free Aerial Cartwheel on the Balance Beam (평균대 한발 몸 펴 옆 공중돌기의 성패에 따른 운동학적 요인 분석)

  • Jung, Choong Min;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.1
    • /
    • pp.24-30
    • /
    • 2022
  • Objective: The purpose of this study was to determine the factors of successful and unsuccessful movements through the analysis of kinematics and muscle activity of the Free Aerial Cartwheel on the balance beam. Method: Subjects (Age: 22.8 ± 2.4 yrs., Height: 158.7 ± 5.0 cm, Body mass: 54.1 ± 6.4 kg, Career: 13 ± 2.4 yrs.) who were currently active as female gymnasts participated in the study. They had no history of surgical treatment within 3 months. Subject criteria included more than 10 years of professional experience in college and professional level of gymnastics and the ability to conduct the Free Aerial Cartwheel on the Balance Beam. Each subject performed 10 times of Free Aerial Cartwheel on the balance beam. One successful trial and one unsuccessful trial (failure) among 10 trials were selected for the comparison. Results: It was found that longer time required in case of unsuccessful trial when performing the Free Aerial Cartwheel on the balance beam compared with successful trial. It is expected to be the result of movement in the last landing section (i.e. phase 5). In addition, it was found that the center of gravity of the body descends at a high speed to perform the jump (i.e. phase 2) in order to obtain a sufficient jumping height when the movement is successful while the knee joint is rapidly extended to perform a jump when movement fails. In the single landing section after the jump (i.e. phase 4), if the ankle joint rapidly dorsiflexed after take-off and the hip joint rapidly flexed, so landing was not successful. Conversely, in a successful landing movement, muscle activity of the biceps femoris was greatly activated resulting no shaking in the last landing section (i.e. phase 5). Conclusion: In order to succeed in this movement, it is necessary to perform a strong jump after rapidly descending the center of gravity of the body using the force of the biceps femoris muscle. Further improvement of the skills on the balance beam requires the analysis of the game-like situation with continuous research on kinematic and kinematic analysis of various techniques, jumps, turns, etc.

Application of Computer-coupled Mass Spectrometer for Continuous On-line Monitoring of Cell Growth and Growth Rate (세포증식과 증식속도의 On-line Monitoring을 위한 Computer- coupled Mass Spectrometer의 응용)

  • 남수완;최춘순;김정회
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.3
    • /
    • pp.241-246
    • /
    • 1989
  • Continuous on-line monitoring of cell concentration and growth rate in aerobic batch fermentation process was carried out by analyzing the exhaust gas composition of tormentor with a quadrupole mass spectrometer. From the mass spectrometric analyses of major gaseous components, i.e. $N_2$, $O_2$, $CO_2$ and $H_2O$, and the material balance equations for oxygen and carbon dioxide, oxygen uptake rate (OUR) rind carbon dioxide evolution rate (CER) were instantaneously calculated using a computer (16-bit IBM PC-AT) interfaced to a quadrupole mass spectrometer. The calculated OUR and CER data were used for the estimation of cell concentration and growth rate of Candida utilis during batch culture. It was found that the cell concentration could be satisfactorily estimated from the data of OUR arid CER during the culture and this method could be successfully und for the continuous monitoring of cell growth and growth rate.

  • PDF

Modeling and Parameter Identification of Pulverizer Mass Flow (미분기 질량흐름에 대한 모델링 및 파라미터 식별)

  • Li, Xinlan;Shin, Yong-Hwan;Jang, Eun-Seong;Lee, Soon-Young;Shin, Hwi-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1694_1695
    • /
    • 2009
  • In this paper, the coal mass flow of the pulverizer used in the coal-fired power plants is modeled in view of the controller design rather than the educational simulator. The coal mass flow is modeled by reinvestigating the mass balance models physically. To identify the model parameters, the Matlab Simulation Tool is used with the data gained from a plant database. It can be seen that the simulated model outputs are well matched with the measured ones.

  • PDF

Development of Balancer for Reduced Vibration of Washing Machine (세탁기의 진동 감소를 위한 밸런서 개발)

  • 폴위즈바;웨이지아카오;박정수;김형균
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.602-607
    • /
    • 1997
  • Ball balance belong to a kind of automatic balancers opten referred to as direct balancer or passive mass systems. In such systems the balancing is achieved with free masses. One of the most prevalent problems encountered in washing is the vibration during spin cycle. The primary cause of this vibration is mass unbalance associated with non unform distribution of clothes. Front loading type machine of European style, especially, has inherent unbalance mass due to its shape and this then makes the vibration worse than top loading type machine, which is more popular in Korea. Since the mass distribution of cloths is random and can not be predicted in advance, direct automatic balances appear to be the only feasible alternative. The results form computer simulation and experimental testing will be presented together with stability implications.

  • PDF

Mass Standards Calibration through Internet (인터넷을 이용한 표준분동 교정 활용)

  • 이우갑;정진완;김광표
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1109-1112
    • /
    • 2003
  • Information technology has enabled mass standards calibration to be performed through internet. For this, an automatic weight handler was manufactured. During the operation the images of weight operation and the system are provided via the measurement system and a web server. The measurement system consists of a balance, a weight handler, instruments for environment measurement and a PC. The weight handler automatically loads and unloads weights on and from the weighing pan. The weight handler allows 6 series weights to be operated for weight calibration of 100-50-20-20-10-10 gram series weight. This capability could be used for "remote training" for series weight calibration.

  • PDF