• 제목/요약/키워드: Masonry Construction

검색결과 168건 처리시간 0.022초

Equivalent frame model and shell element for modeling of in-plane behavior of Unreinforced Brick Masonry buildings

  • Kheirollahi, Mohammad
    • Structural Engineering and Mechanics
    • /
    • 제46권2호
    • /
    • pp.213-229
    • /
    • 2013
  • Although performance based assessment procedures are mainly developed for reinforced concrete and steel buildings, URM (Unreinforced Masonry) buildings occupy significant portion of buildings in earthquake prone areas of the world as well as in IRAN. Variability of material properties, non-engineered nature of the construction and difficulties in structural analysis of masonry walls make analysis of URM buildings challenging. Despite sophisticated finite element models satisfy the modeling requirements, extensive experimental data for definition of material behavior and high computational resources are needed. Recently, nonlinear equivalent frame models which are developed assigning lumped plastic hinges to isotropic and homogenous equivalent frame elements are used for nonlinear modeling of URM buildings. The equivalent frame models are not novel for the analysis of masonry structures, but the actual potentialities have not yet been completely studied, particularly for non-linear applications. In the present paper an effective tool for the non-linear static analysis of 2D masonry walls is presented. The work presented in this study is about performance assessment of unreinforced brick masonry buildings through nonlinear equivalent frame modeling technique. Reliability of the proposed models is tested with a reversed cyclic experiment conducted on a full scale, two-story URM building at the University of Pavia. The pushover curves were found to provide good agreement with the experimental backbone curves. Furthermore, the results of analysis show that EFM (Equivalent Frame Model) with Dolce RO (rigid offset zone) and shell element have good agreement with finite element software and experimental results.

조적요소의 인장응력-변형률 관계 평가 (Evaluation of Tensile Stress-strain Relationship of Masonry Elements)

  • 양근혁;이용제;황용하
    • 대한건축학회논문집:구조계
    • /
    • 제35권3호
    • /
    • pp.27-33
    • /
    • 2019
  • The purpose of this study is to provide and evaluate the tensile properties of masonry element such as tensile strength, strain, modulus of elasticity and stress-strain relationship through the direct tension test with varies of mortar strength. From the experiment, the tension fracture was observed along the interfaces between the brick and the mortar. Tension properties of masonry element was significantly affected by compressive strength of mortar, $f_m$, indicating that higher tensile strength and modulus of elasticity of masonry element were obtained with increase of $f_m$. The strain of a masonry element was inversely proportional to $f_m$ due to the lower ductility of a higher mortar strength. A tensile stress-strain relationship of masonry element was generalized based on the numerical analysis and the regression analysis using test data. The proposed model shows fairly good agreement with the test measurements.

Damages to Rubble Stone Masonry Structures during the January 24, 2020, Sivrice (Elazığ) Earthquake in Turkey

  • Ural, Ali;Firat, Fatih K.;Kara, Mehmet E.;Celik, Tulin;Tanriverdi, Sukran
    • Earthquakes and Structures
    • /
    • 제23권3호
    • /
    • pp.231-243
    • /
    • 2022
  • The earthquake with a magnitude of Mw 6.8, which occurred on January 24, 2020, hit Sivrice (Elazığ) province of Turkey. The earthquake area takes place on the East Anatolian Fault Zone (EAFZ) located between the Arabian and Turkish plates, one of the most active seismic regions in Turkey. According to the Disaster and Emergency Management Presidency of Turkey (AFAD), 584 buildings collapsed, 6845 were heavily damaged, 1207 were moderately damaged, and 14389 were slightly damaged. The authors went to the region of earthquake after the mainshock to investigate the earthquake performances of masonry buildings. This paper presents the seismological aspects of the earthquake, acceleration records, and response spectra with different damping ratios. Furthermore, some typical damages and failure mechanisms on masonry buildings like rubble stone dwellings and minarets are discussed with illustrative photos. Although many major earthquakes have occurred in the region, similar mistakes are still being made in masonry building construction. In consequence, some suggestions viewpoint of the wooden tie beams, the corner details of masonry walls, the door and window openings, the metal fasteners and the earthquake codes are made to be more careful in masonry constructions at the end of the article.

The Construction of Initial Analytical Models Structural Health Monitoring of a Masonry Structure

  • Kim, Seonwoong;Kim, Ji Young;Hwang, In Hwan
    • 국제초고층학회논문집
    • /
    • 제4권3호
    • /
    • pp.191-198
    • /
    • 2015
  • It is important to accurately predict structural responses to external excitations such as typhoons and earthquakes when designing structures for serviceability. One of the key procedures to predict reliable vibration responses is to evaluate accurate structural dynamic properties using finite element (FE) models, which properly represent the realistic behavior of buildings. In the case of historic masonry buildings, structural damage could also be caused by ambient vibrations or impacts. Therefore, the preservation plans of historic buildings for low-level vibrations or impacts should be provided by analyzing structural damages within serviceability levels. For this purpose, it is required to provide FE model construction and response analysis methods verified with field measurement data. In this research, long-term field measurement was performed for a cathedral and its dynamic properties were evaluated using measured data. Then, the model was calibrated based on the measured dynamic properties and an overall construction method for the masonry cathedral was proposed. Using the measured accelerations, the vibrations of the belfry were analyzed using the calibrated FE model and finally, the FE model for the cathedral was verified by comparing the measured accelerations with the modeled results.

외부치장적벽돌 벽체에 대한 콘크리트 보강브라켓의 보강효과에 관한 연구 (A Study on the Strengthening effect of Concrete Reinforcement Bracket on the External Clay Brick Wall)

  • 김선우;김양중
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.117-118
    • /
    • 2020
  • The masonry structure is constructed by cement mortar binding material of brick objects and uses reinforced hardware (connected hardware or wall tie) together when building. However, over time, the corrosion of reinforced steel and the deterioration of joint mortar as well as bricks cause the risk of collapse. In particular, when the externally decorated brick wall is installed on the concrete girder for each floor, the angle bracket is not constructed or corroded, the full-layer weight load is applied to the wall of 0.5B, which is an example of full-scale or collapse. The purpose of this study is to provide numerical information on the reinforcement design by experimentally studying the structural performance of concrete reinforcement brackets that reinforce the vertical load of the exterior wall.

  • PDF

조적조 건축물의 석회 모르타르 특성에 관한 실험적 연구 (An Experimental Study on the Physical Property of Lime Mortar in the Building' Masonry)

  • 권기혁;유혜란
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권5호통권57호
    • /
    • pp.133-141
    • /
    • 2009
  • 50년 이상 경과된 조적조 건축물은 석회모르타르로 시공되었으나 보수공사 시 시멘트모르타르를 사용하여 기존 재료와의 상이함으로 인한 문제가 다수 발생하였다. 또한, 조적조 건축물의 보수공사 시 참고할 수 있는 석회모르타르에 대한 객관화된 자료의 부족과 상세기준이 없으며, 미숙련 조적공의 시공으로 인하여 건축물의 객관적인 구조성능을 평가하기가 어렵다. 조적조 건축물의 원형을 보존하기 위해서는 해당 건물의 재료와 기법에 대한 기술사적 연구가 중요하다. 그러므로 본 연구는 석회모르타르의 배합비, 배합재료, 양생기간 및 조건 등에 따른 압축강도 실험을 행하고, 이를 토대로 시멘트모르타르와 석회모르타르를 비교분석하여 석회모르타르의 구조적 특성을 정리한다.

Use of Recycled Brick Masonry Aggregate (RBMA) and Recycled Brick Masonry Aggregate Concrete (RBMAC) in Sustainable Construction

  • Tara L. Cavalline;David C. Weggel;Dallas E. Schwerin
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.390-390
    • /
    • 2013
  • Use of recycled aggregates in portland cement concrete construction can offer benefits associated with both economy and sustainability. Testing performed to date indicates that RBMA can be used as a 100% replacement for conventional coarse aggregate in concrete that exhibits acceptable mechanical properties for use in structural and pavement elements, including satisfactory performance in some durability tests. RBMAC is currently not used in any type of construction in the United States. However, use of RBMAC could become a viable construction strategy as sustainable building practices become the norm. Rating systems such as LEED offer points for reuse of building materials (particularly on-site) and use of recycled materials. If renovations at an existing facility call for the demolition of existing brick masonry constructions, the rubble could be included as RBMA in new concrete pavement, sidewalks, or curb and gutter. Other potential uses for RBMAC could include those in the precast concrete industry, particularly in architectural precast concrete applications. In addition to providing acceptable strength and economy, the color of RBMA could be an attractive component of architectural precast concrete panels or other façade components. This paper explores the feasibility of use of RBMAC in several types of sustainable construction initiatives, based upon the findings of previous work with RBMAC produced from construction and demolition waste from a case study site. Guidance for obtaining and using RBMA is presented, along with a summary of material properties of RBMAC that will be useful to construction professionals.

  • PDF

건축물에너지 효율을 위한 조적조 열교 차단 브라켓의 성능 평가 연구 (A Study on Performance Evaluation of Masonry Thermal Bridge Blocking Brackets for Building Energy Efficiency)

  • 김웅회;김형규;이태규;이재현;김규용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.175-176
    • /
    • 2023
  • The masonry structure is constructed by cement mortar binding material of brick objects and uses reinforced hardware(connected hardware or wall tie) together when building. However, over time, the corrosion of reinforced steel and the deterioration of joint mortar as well as bricks cause the risk of collapse. In particular, when the externally decorated brick wall is installed on the concrete girder for each floor, the angle bracket is not constructed or corroded, the full-layer weight load is applied to the wall of 0.5B, which is an example of full-scale or collapse. As a result of the evaluation, it was confirmed that the performance was improved compared to the existing bracket, and we plan to carry out a real-life test and long-term performance review of the building using the bracket in the future.

  • PDF

고대 로마건축의 석축기법에 관한 연구 (A Study on Masonry Techniques in Ancient Roman Architecture)

  • 윤성호
    • 한국산학기술학회논문지
    • /
    • 제11권10호
    • /
    • pp.4031-4040
    • /
    • 2010
  • 건축의 시작은 벽체를 구축하는 작업이다. 고대 로마건축에서의 석축기법은 매우 다양하며 새로운 기술의 반복적인 실험을 통하여 로마제국시대의 위대한 건축물들을 완성할 수 있었다. 본 논문에서는 고대로마의 석축기법을 양식적, 구조적, 재료적 또한 의장적인 다양한 관점에서 연구하여 그 변화의 과정을 단계적으로 분석하였으며 심도있는 자료의 수집과 정리를 통하여 로마건축이 인류에게 남긴 위대한 유산의 일부분을 깊이 있게 파헤쳐 보았다. 아직도 우리에게 영향력을 미치고 있는 로마건축의 연속성을 뒷받침 하는 것은 건축의 시작인 석축기술에 있다는 것도 재확인 할 수 있었다. 다양한 실험적 정신이 훌륭한 건축물이 만들어지는 토대가 됨을 로마건축은 보여주고 있다.

Strengthening techniques for masonry structures of cultural heritage according to recent Croatian provisions

  • Hadzima-Nyarko, Marijana;Ademovic, Naida;Pavic, Gordana;Sipos, Tanja Kalman
    • Earthquakes and Structures
    • /
    • 제15권5호
    • /
    • pp.473-485
    • /
    • 2018
  • The buildings of architectural and cultural heritage are mostly built with stone or brick wall elements, which are connected using limestone or limestone cement mortar, without a full knowledge of the mechanical properties of masonry structures. The compatibility of heritage masonry buildings with valid technical specifications and the rules for earthquake resistance implies the need for construction work such as repairs, strengthening or reconstruction. By strengthening the masonry buildings, ductility and bearing capacity are increased to a level, which, in the case of the earthquake design, allows for some damage to happen, however the structure retains sufficient usability and bearing capacity without the possibility of collapse. Comparison between traditional and modern techniques for seismic strengthening of masonry buildings is given according to their effects, benefits and disadvantages. Recent Croatian provisions provided for heritage buildings enabling deviation of technical specifications are discussed.