• Title/Summary/Keyword: Mask detection

Search Result 340, Processing Time 0.023 seconds

Virtual core point detection and ROI extraction for finger vein recognition (지정맥 인식을 위한 가상 코어점 검출 및 ROI 추출)

  • Lee, Ju-Won;Lee, Byeong-Ro
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.249-255
    • /
    • 2017
  • The finger vein recognition technology is a method to acquire a finger vein image by illuminating infrared light to the finger and to authenticate a person through processes such as feature extraction and matching. In order to recognize a finger vein, a 2D mask-based two-dimensional convolution method can be used to detect a finger edge but it takes too much computation time when it is applied to a low cost micro-processor or micro-controller. To solve this problem and improve the recognition rate, this study proposed an extraction method for the region of interest based on virtual core points and moving average filtering based on the threshold and absolute value of difference between pixels without using 2D convolution and 2D masks. To evaluate the performance of the proposed method, 600 finger vein images were used to compare the edge extraction speed and accuracy of ROI extraction between the proposed method and existing methods. The comparison result showed that a processing speed of the proposed method was at least twice faster than those of the existing methods and the accuracy of ROI extraction was 6% higher than those of the existing methods. From the results, the proposed method is expected to have high processing speed and high recognition rate when it is applied to inexpensive microprocessors.

MEMS Fabrication of Microchannel with Poly-Si Layer for Application to Microchip Electrophoresis (마이크로 칩 전기영동에 응용하기 위한 다결정 실리콘 층이 형성된 마이크로 채널의 MEMS 가공 제작)

  • Kim, Tae-Ha;Kim, Da-Young;Chun, Myung-Suk;Lee, Sang-Soon
    • Korean Chemical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.513-519
    • /
    • 2006
  • We developed two kinds of the microchip for application to electrophoresis based on both glass and quartz employing the MEMS fabrications. The poly-Si layer deposited onto the bonding interface apart from channel regions can play a role as the optical slit cutting off the stray light in order to concentrate the UV ray, from which it is possible to improve the signal-to-noise (S/N) ratio of the detection on a chip. In the glass chip, the deposited poly-Si layer had an important function of the etch mask and provided the bonding surface properly enabling the anodic bonding. The glass wafer including more impurities than quartz one results in the higher surface roughness of the channel wall, which affects subsequently on the microflow behavior of the sample solutions. In order to solve this problem, we prepared here the mixed etchant consisting HF and $NH_4F$ solutions, by which the surface roughness was reduced. Both the shape and the dimension of each channel were observed, and the electroosmotic flow velocities were measured as 0.5 mm/s for quartz and 0.36 mm/s for glass channel by implementing the microchip electrophoresis. Applying the optical slit with poly-Si layer provides that the S/N ratio of the peak is increased as ca. 2 times for quartz chip and ca. 3 times for glass chip. The maximum UV absorbance is also enhanced with ca. 1.6 and 1.7 times, respectively.

Clinical Applications of Neuroimaging with Susceptibility Weighted Imaging: Review Article (SWI의 신경영상분야의 임상적 이용)

  • Roh, Keuntak;Kang, Hyunkoo;Kim, Injoong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.290-302
    • /
    • 2014
  • Purpose : Susceptibility-weighted magnetic resonance (MR) sequence is three-dimensional (3D), spoiled gradient-echo pulse sequences that provide a high sensitivity for the detection of blood degradation products, calcifications, and iron deposits. This pictorial review is aimed at illustrating and discussing its main clinical applications. Materials and Methods: SWI is based on high-resolution, 3D, fully velocity-compensated gradient-echo sequences using both magnitude and phase images. To enhance the visibility of the venous structures, the magnitude images are multiplied with a phase mask generated from the filtered phase data, which are displayed at best after post-processing of the 3D dataset with the minimal intensity projection algorithm. A total of 200 patients underwent MR examinations that included SWI on a 3 tesla MR imager were enrolled. Results: SWI is very useful in detecting multiple brain disorders. Among the 200 patients, 80 showed developmental venous anomaly, 22 showed cavernous malformation, 12 showed calcifications in various conditions, 21 showed cerebrovascular accident with susceptibility vessel sign or microbleeds, 52 showed brain tumors, 2 showed diffuse axonal injury, 3 showed arteriovenous malformation, 5 showed dural arteriovenous fistula, 1 showed moyamoya disease, and 2 showed Parkinson's disease. Conclusion: SWI is useful in detecting occult low flow vascular lesions, calcification and microbleed and characterising diverse brain disorders.

Eyelid Detection Algorithm Based on Parabolic Hough Transform for Iris Recognition (홍채 인식을 위한 포물 허프 변환 기반 눈꺼풀 영역 검출 알고리즘)

  • Jang, Young-Kyoon;Kang, Byung-Jun;Park, Kang-Ryoung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.1
    • /
    • pp.94-104
    • /
    • 2007
  • Iris recognition is biometric technology which uses a unique iris pattern of user in order to identify person. In the captured iris image by conventional iris recognition camera, it is often the case with eyelid occlusion, which covers iris information. The eyelids are unnecessary information that causes bad recognition performance, so this paper proposes robust algorithm in order to detect eyelid. This research has following three advantages compared to previous works. First, we remove the detected eyelash and specular reflection by linear interpolation method because they act as noise factors when locating eyelid. Second, we detect the candidate points of eyelid by using mask in limited eyelid searching area, which is determined by searching the cross position of eyelid and the outer boundary of iris. And our proposed algorithm detects eyelid by using parabolic hough transform based on the detected candidate points. Third, there have been many researches to detect eyelid, but they did not consider the rotation of eyelid in an iris image. Whereas, we consider the rotation factor in parabolic hough transform to overcome such problem. We tested our algorithm with CASIA Database. As the experimental results, the detection accuracy were 90.82% and 96.47% in case of detecting upper and lower eyelid, respectively.

Automatic Skin Basal Cell Carcinoma Detection Using Protophorphyrin IX((PpIX) Fluorescence Image (PpIX 형광영상을 이용한 피부 기저세포암 자동검출)

  • Yu, Hong-Yeon;Jun, Do-Young;Kim, Min-Sung;Hong, Sung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.1
    • /
    • pp.47-54
    • /
    • 2008
  • In this paper, we propose an auto-detection algorithm of basal cell carcinoma(BCC) from the protophorphyrin IX(PpIX) fluorescence image induced by appling the methyl 5-aminolaevulinate(MAL) ointment-induced protophorphyrin IX(PpIX) to the skin tumour area and then shining the wood lamp on the area. The proposed algorithm first generates 3 mask areas-tumor area, suspected tumor area and tumor free area and then applies local watershed algorithm to the turner and the suspected tumor areas to make small watershed regions that include similar luminance value pixels. Next, small watershed regions are merged by hierarchical queue based fast region merging that uses the difference between the average luminance values of adjacent watershed regions as a region merging criterion and finally BCC regions are detected. 50 tissue samples are acquired from the tumour regions of 10 patients with BCC that are extracted by using the proposed algorithm and are performed pathological examination by expert dermatologist. Experiment result shows the rate of tumor detection from BCC lesion using presurgical in vivo of MAL-indeuced PpIX fluorescence has high sensitivity 94.1% and relatively high specificity 82.6%.

Adjacent Pixels based Noise Mitigation Filter in Salt & Pepper Noise Environments (Salt & Pepper 잡음 환경에서 인접 픽셀 기반 잡음 완화 필터)

  • Seong, Chi Hyuk;Shin, Soo Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.6
    • /
    • pp.65-71
    • /
    • 2017
  • Digital images and videos are subject to various types of noise during storage and transmission. Among these noises, Salt & Pepper noise degrades the compression efficiency of the original data and causing deterioration of performance in edge detection or segmentation used in an image processing method. In order to mitigate this noise, there are many filters such as Median Filter, Weighted Median Filter, Center Weighted Median Filter, Switching Weighted Median Filter and Adaptive Median Filter. However these methods are inferior in performance at high noise density. In this paper we propose a new type of filter for noise mitigation in wireless communication environment where Salt & Pepper noise occurs. The proposed filter detects the location of the damaged pixel by Salt & Pepper noise detection and mitigates the noise by using adjacent pixel values which are not damaged in a certain area. Among the proposed filters, the performance of the filter using the $3{\times}3$ error mask is compared with that of the conventional methods and it is confirmed that when density of noise in the image is 95%, their performances are improved as 13.24 dB compared to MF and 13.09 dB compared to AMF.

An Automatic Segmentation Method for Video Object Plane Generation (비디오 객체 생성을 위한 자동 영상 분할 방법)

  • 최재각;김문철;이명호;안치득;김성대
    • Journal of Broadcast Engineering
    • /
    • v.2 no.2
    • /
    • pp.146-155
    • /
    • 1997
  • The new video coding standard Iv1PEG-4 is enabling content-based functionalities. It requires a prior decomposition of sequences into video object planes (VOP's) so that each VOP represents moving objets. This paper addresses an image segmentation method for separating moving objects from still background (non-moving area) in video sequences using a statistical hypothesis test. In the proposed method. three consecutive image frames are exploited and a hypothesis testing is performed by comparing two means from two consecutive difference images. which results in a T-test. This hypothesis test yields a change detection mask that indicates moving areas (foreground) and non-moving areas (background), Moreover. an effective method for extracting

  • PDF

Design and Implementation of UHF RFID Reader System Supporting Sensor Data Processing (센서 데이터 처리를 지원하는 UHF RFID 리더 시스템의 설계 및 구현)

  • Shin, Dong-Beom;Lee, Heyung-Sub;Choi, Gil-Young;Kim, Dae-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12A
    • /
    • pp.925-932
    • /
    • 2009
  • Precise temperature monitoring is the major preconditioning to supervise quality losses within the transport chain for fresh products. ISO/IEC18000-6REV1 defines new protocols supporting BAP(Battery Assisted Passive) RFID tag which is completely compatible with EPCglobal Class1 Generation2 specification. In this paper, we designed a modem supporting BAP RFID tag with FPGA(Field Programmable Gate Array) and implemented sensor data processing function defined in ISO/IEC18000-6REV1. The transmit block of the modem supports pulse shaping filter and the output signal of the implemented RFID reader is satisfied with the spectrum mask defined in the standard. The receive block of the modem uses Gardner TED to synchronize timing of symbol. In this paper, we designed a modem supporting ISO/IEC18000-6REV1 standard and developed a RFID reader sndard. The developed RFID reader sndard can recognize sensor tag and passive tag in the wireless environment and supports real-time processing of the sensor data in the embedded linux platform.

Cooperative Diversity MIMO System for m with 8 Transmit Antennas (8개 송신 안테나 UWB를 위한 협동 다이버시티 MIMO 시스템)

  • Lee Kwang-Jae;Hou Jia;Lee Moon-Ho;Cho Sam-Goo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.7 s.98
    • /
    • pp.709-719
    • /
    • 2005
  • The forward link of the 3 G CDMA system may become limited under the increasing of the number of users. The conventional channelization code, Walsh code, has not enough sizes for much possible non, therefore, the quasi orthogonal function(QOF), which process optimal cross-correlation with Walsh code, is considered. In this paper, we investigate quasi orthogonal function on Jacket matrices, which can lead lower correlations values and better performance in 3 G CDMA system. Moreover, to simple the detector and improve the BER performance, a novel detection for QOF CDMA system is proposed. Finally, the simple recursive generation of the bent sequences for QOF mask function is discussed.

다채널 표면 플라즈몬 공명 영상장치를 이용한 자기조립 단분자막의 표면 분석

  • Pyo, Hyeon-Bong;Sin, Yong-Beom;Yun, Hyeon-Cheol
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.74-78
    • /
    • 2003
  • Multi-channel images of 11-MUA and 11-MUOH self-assembled monolayers were obtained by using two-dimensional surface plasmon resonance (SPR) absorption. Patterning process was simplified by exploiting direct photo-oxidation of thiol bonding (photolysis) instead of conventional photolithography. Sharper images were resolved by using a white light source in combination with a narrow bandpass filter in the visible region, minimizing the diffraction patterns on the images. The line profile calibration of the image contrast caused by different resonance conditions at each points on the sensor surface (at a fixed incident angle) enables us to discriminate the monolayer thickness in sub-nanometer scale. Furthermore, there is no signal degradation such as photo bleaching or quenching which are common in the detection methods based on the fluorescence.

  • PDF