• Title/Summary/Keyword: Mary

Search Result 3,068, Processing Time 0.026 seconds

A Comparative Study of Measles According to Age (홍역에서 연령별 임상상 비교)

  • Eun, Eun-Sung;Choi, Sang-Lim;Lee, Kyung-Yil;Lee, Hyung-Shin;Hong, Ja-Hyun;Kang, Jin-Han;Whang, Kyung-Tai
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.1
    • /
    • pp.33-36
    • /
    • 2003
  • Purpose : We evaluated clinical manifestations and laboratory findings in patients with measles according to age distribution. Methods : Retrospective analyses were performed using medical records of patients with measles admitted to The Catholic University of Korea, Daejon St. Mary's Hospital from October 2000 to May 2001. We divided the patients with measles into three age groups, i.e., those who were under two years of age(159 patients), those between 9-11 years of age(39 patients), and those older than 16 years of age who were hospitalized in the department of internal medicine(young adult group; 23 patients). We compared clinical and laboratory characteristics among these three groups. Results : Almost all patients with measles were presented with fever, skin rash and cough. No statistical differences were present between the three groups in total fever duration, number of hospitalization days, complications determined with longer hospitalization for more than eight days, and positive values of anti-measles IgM. Patients under 2 years of age showed statistically higher levels of white bood cell and lymphocyte counts. However, neutropenia and lymphopenia were observed in all age groups compared with age-matched standard values. Campared with the other two age groups, the young adult group showed a higher mean level of liver enzymes(AST/ALT) and more patients with a level twice as high as the normal values. Conclusion : Clinical manifestations including complications according to age groups showed no significant differences in patients with measles. Hepatic involvement was more prevalent in the young adult group.

Development of Independent Target Approximation by Auto-computation of 3-D Distribution Units for Stereotactic Radiosurgery (정위적 방사선 수술시 3차원적 공간상 단위분포들의 자동계산법에 의한 간접적 병소 근사화 방법의 개발)

  • Choi Kyoung Sik;Oh Seung Jong;Lee Jeong Woo;Kim Jeung Kee;Suh Tae Suk;Choe Bo Young;Kim Moon Chan;Chung Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.24-31
    • /
    • 2005
  • The stereotactic radiosurgery (SRS) describes a method of delivering a high dose of radiation to a small tar-get volume in the brain, generally in a single fraction, while the dose delivered to the surrounding normal tissue should be minimized. To perform automatic plan of the SRS, a new method of multi-isocenter/shot linear accelerator (linac) and gamma knife (GK) radiosurgery treatment plan was developed, based on a physical lattice structure in target. The optimal radiosurgical plan had been constructed by many beam parameters in a linear accelerator or gamma knife-based radiation therapy. In this work, an isocenter/shot was modeled as a sphere, which is equal to the circular collimator/helmet hole size because the dimension of the 50% isodose level in the dose profile is similar to its size. In a computer-aided system, it accomplished first an automatic arrangement of multi-isocenter/shot considering two parameters such as positions and collimator/helmet sizes for each isocenter/shot. Simultaneously, an irregularly shaped target was approximated by cubic structures through computation of voxel units. The treatment planning method by the technique was evaluated as a dose distribution by dose volume histograms, dose conformity, and dose homogeneity to targets. For irregularly shaped targets, the new method performed optimal multi-isocenter packing, and it only took a few seconds in a computer-aided system. The targets were included in a more than 50% isodose curve. The dose conformity was ordinarily acceptable levels and the dose homogeneity was always less than 2.0, satisfying for various targets referred to Radiation Therapy Oncology Group (RTOG) SRS criteria. In conclusion, this approach by physical lattice structure could be a useful radiosurgical plan without restrictions in the various tumor shapes and the different modality techniques such as linac and GK for SRS.

  • PDF

Enhancement of the Deformable Image Registration Accuracy Using Image Modification of MV CBCT (Megavoltage Cone-beam CT 영상의 변환을 이용한 변환 영상 정합의 정확도 향상)

  • Kim, Min-Joo;Chang, Ji-Na;Park, So-Hyun;Kim, Tae-Ho;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.28-34
    • /
    • 2011
  • To perform the Adaptive Radiation Therapy (ART), a high degree of deformable registration accuracy is essential. The purpose of this study is to identify whether the change of MV CBCT intensity can improve registration accuracy using predefined modification level and filtering process. To obtain modification level, the cheese phantom images was acquired from both kilovoltage CT (kV CT), megavoltage cone-beam CT (MV CBCT). From the cheese phantom images, the modification level of MV CBCT was defined from the relationship between Hounsfield Units (HUs) of kV CT and MV CBCT images. 'Gaussian smoothing filter' was added to reduce the noise of the MV CBCT images. The intensity of MV CBCT image was changed to the intensity of the kV CT image to make the two images have the same intensity range as if they were obtained from the same modality. The demon deformable registration which was efficient and easy to perform the deformable registration was applied. The deformable lung phantom which was intentionally created in the laboratory to imitate the changes of the breathing period was acquired from kV CT and MV CBCT. And then the deformable lung phantom images were applied to the proposed method. As a result of deformable image registration, the similarity of the correlation coefficient was used for a quantitative evaluation of the result was increased by 6.07% in the cheese phantom, and 18% in the deformable lung phantom. For the additional evaluation of the registration of the deformable lung phantom, the centric coordinates of the mark which was inserted into the inner part of the phantom were measured to calculate the vector difference. The vector differences from the result were 2.23, 1.39 mm with/without modification of intensity of MV CBCT images, respectively. In summary, our method has quantitatively improved the accuracy of deformable registration and could be a useful solution to improve the image registration accuracy. A further study was also suggested in this paper.

Development of the Multi-Parametric Mapping Software Based on Functional Maps to Determine the Clinical Target Volumes (임상표적체적 결정을 위한 기능 영상 기반 생물학적 인자 맵핑 소프트웨어 개발)

  • Park, Ji-Yeon;Jung, Won-Gyun;Lee, Jeong-Woo;Lee, Kyoung-Nam;Ahn, Kook-Jin;Hong, Se-Mie;Juh, Ra-Hyeong;Choe, Bo-Young;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.153-164
    • /
    • 2010
  • To determine the clinical target volumes considering vascularity and cellularity of tumors, the software was developed for mapping of the analyzed biological clinical target volumes on anatomical images using regional cerebral blood volume (rCBV) maps and apparent diffusion coefficient (ADC) maps. The program provides the functions for integrated registrations using mutual information, affine transform and non-rigid registration. The registration accuracy is evaluated by the calculation of the overlapped ratio of segmented bone regions and average distance difference of contours between reference and registered images. The performance of the developed software was tested using multimodal images of a patient who has the residual tumor of high grade gliomas. Registration accuracy of about 74% and average 2.3 mm distance difference were calculated by the evaluation method of bone segmentation and contour extraction. The registration accuracy can be improved as higher as 4% by the manual adjustment functions. Advanced MR images are analyzed using color maps for rCBV maps and quantitative calculation based on region of interest (ROI) for ADC maps. Then, multi-parameters on the same voxels are plotted on plane and constitute the multi-functional parametric maps of which x and y axis representing rCBV and ADC values. According to the distributions of functional parameters, tumor regions showing the higher vascularity and cellularity are categorized according to the criteria corresponding malignant gliomas. Determined volumes reflecting pathological and physiological characteristics of tumors are marked on anatomical images. By applying the multi-functional images, errors arising from using one type of image would be reduced and local regions representing higher probability as tumor cells would be determined for radiation treatment plan. Biological tumor characteristics can be expressed using image registration and multi-functional parametric maps in the developed software. The software can be considered to delineate clinical target volumes using advanced MR images with anatomical images.

Deduction and Verification of Optimal Factors for Stent Structure and Mechanical Reaction Using Finite Element Analysis (스텐트의 구조 및 기계적인 반응에 대한 최적인자 도출과 유한요소해석법을 통한 검증)

  • Jeon, Dong-Min;Jung, Won-Gyun;Kim, Han-Ki;Kim, Sang-Ho;Shin, Il-Gyun;Jang, Hong-Seok;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.201-208
    • /
    • 2010
  • Recently, along with technology development of endoscopic equipment, a stent has been developed for the convenience of operation, shortening of recovery times, and reduction of patient's pain. To this end, optimal factors are simulated for the stent structure and mechanical reaction and verified using finite element analysis. In order to compare to present commercialized product such as Zilver (Cook, Bloomington, Indiana, USA) and S.M.A.R.T (Cordis, Bridgewater Towsnhip, New Jersey, USA), mechanical impact factors were determined through Taguchi factor analysis, and flexibility and expandability of all the products including ours were tested using finite element analysis. Also, important factors were sought that fulfill the optimal condition using central composition method of response surface analysis, and optimal design were carried out based on the important factors. From the centra composition method of Response surface analysis, it is found that importat factors for flexibility is stent thickness (T) and unit area (W) and those for expandability is stent thickness (T). In results, important factors for optimum condition are 0.17 mm for stent thickness (T) and $0.09\;mm^2$ for unit area (W). Determined and verified by finite element analysis in out research institute, a stent was manufactured and tested with the results of better flexibility and expandability in optimal condition compared to other products. Recently, As Finite element analysis stent mechanical property assessment for research much proceed. But time and reduce expenses research rarely stent of optimum coditions. In this research, Important factor as mechanical impact factor stent Taguchi factor analysis arrangement to find flexibility with expansibility as Finite element analysis. Also, Using to Center composition method of Response surface method appropriate optimized condition searching for important factor, these considering had design optimized. Production stent time and reduce expenses was able to do the more coincide with optimum conditions. These kind of things as application plan industry of stent development period of time and reduce expenses etc. be of help to many economic development.

Analysis of radiation exposure in radiation worker in medical facility and student in clinical practice (의료기관 방사선작업종사자와 임상실습 학생의 피폭선량 분석)

  • Lee, Joo-Ah;Choi, Kwan-Woo;Min, Jung-Whan;Lim, Jong-Cheon;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.442-448
    • /
    • 2016
  • This study was conducted to determine the appropriateness of systemic radiation exposure control for students in clinical practice by comparing radiation exposure in radiography employees at different stations of a hospital with that of students conducting clinical practice using identical stations. Overall, 121 students who conducted clinical practice in the department of radiology area of C university hospital from July 2014 to August 2014 and 62 workers working in the same medical facility (47 in the department of radiology, 8 in the department of radiation oncology, 7 in the department of nuclear medicine) were investigated. The radiation exposure experienced by students was measured for 8 weeks, which is the duration of the clinical practice. Additionally, radiation exposure of workers were classified into 4 groups, department of radiology, department of radiation oncology, and department of nuclear medicine was compared. Dose was measured with OSLD and differences among groups were identified by ANOVA followed by Duncan's multiple range test. Among employees, those in the department of radiology, oncology and nuclear medicine were exposed depth doses of $0.127{\pm}0.331mSv$, $0.01{\pm}0.003mSv$, and $0.431{\pm}0.205mSv$, respectively, while students were exposed to $0.143{\pm}0.136mSv$. Additionally, workers in the department of radiology, oncology and nuclear medicine were exposed to surface doses of $0.131{\pm}0.331mSv$, $0.009{\pm}0.003mSv$, and $0.445{\pm}0.198mSv$, respectively, while students were exposed to $0.151{\pm}0.14mSv$, which was significantly different in both doses (p < 0.01). The average dose that students received is higher than that of the other groups (except for nuclear medicine workers), indicating that further improvements must be made in systemic controls for individual radiation exposure by including the students as subjects of management for protection from radiation.

Evaluation of Photoneutron Dose for Prostate Cancer Radiation Therapy by Using Optically Stimulated Luminescence Dosimeter (OSLD) (전립선암 방사선치료 시 광자극발광선량계를 이용한 광중성자선량 평가)

  • Lee, Joo-Ah;Back, Geum-Mun;Kim, Yeon-Soo;Son, Soon-Yong;Choi, Kwan-Woo;Yoo, Beong-Gyu;Jeong, Hoi-Woun;Jung, Jae-Hong;Kim, Ki-Won;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.125-134
    • /
    • 2014
  • This study is to provide basic information regarding photoneutron doses in terms of radiation treatment techniques and the number of portals in intensity-modulated radiation therapy (IMRT) by measuring the photoneutron doses. Subjects of experiment were 10 patients who were diagnosed with prostate cancer and have received radiation treatment for 5 months from September 2013 to January 2014 in the department of radiation oncology in S hospital located in Seoul. Thus, radiation treatment plans were created for 3-Dimensional Conformal Radiotherapy (3D-CRT), Volumetric-Modulated Arc Radiotherapy (VMAT), IMRT 5, 7, and 9 portals. The average difference of photoneutron dose was compared through descriptive statistics and variance analysis, and analyzed influence factors through correlation analysis and regression analysis. In summarized results, 3D-CRT showed the lowest average photoneutron dose, while IMRT caused the highest dose with statistically significance (p <.01). The photoneutron dose by number of portals of IMRT was $4.37{\pm}1.08mSv$ in average and statistically showed very significant difference among the number of portals (p <.01). Number of portals and photoneutron dose are shown that the correlation coefficient is 0.570, highly statistically significant positive correlation (p <.01). As a result of the linear regression analysis of number of portals and photoneutron dose, it showed that photoneutron dose significantly increased by 0.373 times in average as the number of portals increased by 1 stage. In conclusion, this study can be expected to be used as a quantitative basic data to select an appropriate IMRT plans regarding photoneutron dose in radiation treatment for prostate cancer.

An Evaluation of Vitek MS System for Rapid Identification of Bacterial Species in Positive Blood Culture (혈액배양 양성검체에서 패혈증 원인균 신속동정을 위한 Vitek MS 시스템의 유용성 평가)

  • Park, Kang-Gyun;Kim, Sang-Ha;Choi, Jong-Tae;Kim, Sunghyun;Kim, Young-Kwon;Yu, Young-Bin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.407-412
    • /
    • 2017
  • The aim of this study was to shorten the time required for subculture and bacterial identification and obtain a simple and rapid identification method for new test methods for bloodstream infections. The following results were obtained using a mass spectrometer. In Vitek 2, 208 (81.8%) cases were well-identified and 45 isolates were not identified in blood cultures. Among 208 cases, 146 (57.5%) were Gram positive bacteria and 108 (42.5%) were Gram negative bacteria. In total, 233 were identified to the species level and 21 were identified to the genus level. The identification error was found to be Propionibacterium acnes as Clostridium bifermentans. The accuracy of Enterobacteriaceae, glucose non-fermentative bacilli (GNFB), and staphylococci were 81/83 (97.6%), 12/15 (80.0%), and 72/85 (84.7%), respectively. The concordance rate of Vitek 2 and Vitek MS by the direct method was 81.8% and 45 isolates were not identified. Most of the unidentified bacteria were Gram positive bacteria (N=37). The Gram positive bacteria were streptococci (14), coagulase-negative staphylococci (CNS) (11), enterococci (3), Staphylococcus aureus (2), Micrococcus spp. (2), Bacillus spp. (2) and Actinomyces odontolyticus, Finegoldia magna, and Peptostreptococcus spp. The results reporting time was reduced to 24~72 hours compared to the conventional method. The rate of identification of the aerobic and anaerobic cultures was similar, but the use of an anaerobic culture did not require a dissolution process, which could shorten the sample preparation time. These results suggest that the method of direct identification in blood cultures is very useful for the treatment of patients. In further studies, it might be necessary to further improve the method for identifying streptococci and CNS, which were lacking in accuracy in this study.

The Mechanism of Iron Transport after Intratracheal Instillation of Iron in Rats (랏트의 기관내 Fe 노출후 Fe 이동에 대한 연구)

  • Kwon, Min;Choi, Byung-Sun;Park, Eon-Sub;Chung, Nam-Hyun;Park, Sung-Jo;Lim, Young;Park, Jung-Duck
    • Journal of Preventive Medicine and Public Health
    • /
    • v.37 no.4
    • /
    • pp.329-336
    • /
    • 2004
  • Objectives : Iron (Fe) is an essential element in biological processes; however excessive Fe is harmful to human health. Some air pollutants contain a high level of Fe, and the human lung could therefore be over-exposed to Fe through inhaled air pollutants. This study was performed to investigate the role of metal transporters (divalent metal transporter 1, DMT1, and metal transporter protein 1, MTP1) in the lung under the environments of Fe deficiency in the body and Fe over-exposure in the lung. Methods : Rats were fed Fe deficient (FeD, 2-6 mg Fe/kg) or Fe supplemented (FeS, 120 mg Fe/kg) diet for 4 weeks, followed by a single intratracheal instillation of ferrous sulfate at low (10 mg/kg) or high (20 mg/kg) dose. Fe concentration was analyzed in the serum, lung and liver, and histopathological findings were observed in the lung at 24 hours after Fe administration. The level of DMT1 and MTP1 expression in the lung was analyzed by RT-PCR. Also, the effect of Fe deficiency in the body was evaluated on the level of Fe concentration and metal transporters compared to FeS-diet fed rats at the end of 4-week FeD or FeS diet. Results : The 4-week FeD diet in rats induced an Fe deficiency anemia with decreased serum total Fe, increased unsaturated Fe binding capacity and hypochromic microcytic red blood cells. The concentration of Fe in the lung and liver was lower in the FeD-diet fed rats than in the FeS-diet fed rats. The level of metal transporters mRNA expression was higher in the FeD-diet fed rats than in the FeS-diet. The concentration of Fe in the lung was increased in a dose-dependent pattern after intratracheal instillation of Fe into the rats, while the level of Fe in the serum and liver was not increased in the low-dose Fe administered rats. Therefore, DMT1 and MTP1 mRNA was highly expressed in both FeD-diet and FeS-diet fed rats, after intratracheal instillation of Fe. Conclusions : DMT1 and MTP1 mRNA were more highly expressed in FeD-diet fed rats than in FeS-diet fed rats. The over-exposure of Fe intratracheally induced high expression of metal transporters and increased Fe deposition in the lung in both FeD-diet and FeS-diet fed rats, but did not increase the Fe level of the serum and liver in low-dose Fe administered rats. These results suggest that the role of metal transporters in the lung might be different in a part from the duodenum under the environment of over-exposure to Fe.

The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography) (MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가)

  • Ryu, Gwi-Bok;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Dong, Kyung-Rae;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • The purpose of this study is to measure scattered ray which is occurred except for Z-axis range of the detector in MDCT's iso-center and present the basic data about the standard for reduction of scattered ray. The development of MDCT brings out the enlargement of beam thickness to the patient's Z-axis, which distributes to the increase in exposure dose according to the rise of scattered ray. Also MDCT brings out the increase of scattered ray about 4times more than SDCT. To evaluate scattered ray according to the change of beam thickness on MDCT, we measured scattered ray of MDCT's Z-axis beam thickness by using one 16-slice CTs and two 64-slice CTs. We used the ionization chamber 60ml 2026C as the equipment of measurement. In our results, we found out that the change of scattered ray according to the beam thickness in the same kVp has increase of scattered ray. Secondly we found out the increase of scattered ray according to the increase of kVp. Lastly we found out the decrease of scattered ray according to the increase of the distance from the ionization chamber.