• Title/Summary/Keyword: Marker Making

Search Result 67, Processing Time 0.03 seconds

Establishment of Functional Cells for Vascular Defect Disease from Human Embryonic Stem Cell via Region Sorting Depending on Cell Volume (세포 크기 차이를 이용한 유세포 분석을 통한 인간배아줄기세포 유래 기능성 혈관세포의 확립)

  • Lee, Ji-Hye;Kim, Ju-Mi;Chung, Hyung-Min;Chae, Jung-Il
    • Microbiology and Biotechnology Letters
    • /
    • v.39 no.4
    • /
    • pp.364-373
    • /
    • 2011
  • Human embryonic stem cells have been highlighted as a valuable cellular source in the regenerative medicine field, due to their pluripotency. However, there is the challenge of the establishment of specific functional cell type forms of undifferentiated human embryonic stem cells (hESC). To establish and purify functional cell types from hESCs, we differentiated undifferentiated hESCs into vascular lineage cells and sorted the specific cell population from the whole cell population, depending on their cell volume, and compared them with the non-sorted cell population. We observed that about 10% of the PECAM positive population existed in the VEGF induced differentiating human embryoid body (hEB), and differentiated hEBs were made into single cells for cell transplantation. After making single cells, we performed cell sorting using a fluorescence-activated cell sorter (FACs), according to their cell volume on the basis of FSC region gating, and compared their therapeutic capacity with the non-sorted cell population through cell transplantation into hindlimb ischemic disease model mice. 4 Weeks after cell transplantation, the recovery rate of blood perfusion reached 54% and 17% in the FSC regions of sorted cells- and non-sorted cells, respectively. This result suggests that derivation of a functional cell population from hESCs can be performed through cell sorting on the basis of cell volume after preliminary differentiation induction. This approach may then greatly contribute to overcoming the limitations of marker sorting.

A study on image registration and fusion of MRI and SPECT/PET (뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구)

  • Joo, Ra-Hyung;Choi, Yong;Kwon, Soo-Il;Heo, Soo-Jin
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 1998
  • Nuclear Medicine Images have comparatively poor spatial resolution, making it difficult to relate the functional information which they contain to precise anatomical structures. Anatomical structures useful in the interpretation of SPECT /PET Images were radiolabelled. PET/SPECT Images Provide functional information, whereas MRI mainly demonstrate morphology and anatomical. Fusion or Image Registration improves the information obtained by correlating images from various modalities. Brain Scan were studied on one or more occations using MRI and SPECT. The data were aligned using a point pair methods and surface matching. SPECT and MR Images was tested using a three dimensional water fillable Hoffman Brain Phantom with small marker and PET and MR Image was tested using a patient data. Registration of SPECT and MR Images is feasible and allows more accurate anatomic assessment of sites of abnormal uptake in radiolabeled studies. Point based registration was accurate and easily implemented three dimensional registration of multimodality data set for fusion of clinical anatomic and functional imaging modalities. Accuracy of a surface matching algorithm and homologous feature pair matching for three dimensional image registration of Single Photon Emission Computed Tomography Emission Computed Tomography (SPECT), Positron Emission Tomography (PET) and Magnetic Resonance Images(MRD was tested using a three dimensional water fill able brain phantom and Patients data. Transformation parameter for translation and scaling were determined by homologous feature point pair to match each SPECT and PET scan with MR images.

  • PDF

Diagnostic Utility of Pleural Fluid Soluble Triggering Receptor Expressed on Myeloid Cells 1 Protein in Patients with Exudative Pleural Effusion (삼출성흉수에서 Soluble Triggering Receptor Expressed on Myeloid Cells 1 Proteion의 진단적 유용성)

  • Sim, Yun Su;Lee, Jin Hwa;Cheun, En Mi;Chang, Jung Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.6
    • /
    • pp.499-505
    • /
    • 2007
  • Background: Triggering receptor expressed on myeloid cells 1 protein (TREM-1) is a cell surface molecule expressed on neutrophils and monocytes, and it plays an important role in myeloid cell-activated inflammatory response. The aim of this study was to investigate the diagnostic efficiency of soluble (s) TREM-1 in the patients who had pleural effusion from various causes. Methods: Forty-five patients with exudative pleural effusion were included in this study. The level of sTREM-1 was measured in both the serum and pleural fluids by immunoblot assay with using human-sTREM-1 antibody. Results: The pleural fluid sTREM-1 was significantly different in the three groups of exudative pleural effusion (p=0.011). Particularly, the patients with parapneumonic effusion were found to have significantly higher pleural fluid levels of sTREM-1 than patients with tuberculous (p<0.05) and malignant effusion, respectively (p<0.05). However, the serum sTREM-1 did not show a significant difference in the three groups. In order to evaluate the diagnostic utility of pleural fluid sTREM-1, the receiver operating characteristic (ROC) curve was constructed and the area under the curve (AUC) was 0.818 (p=0.001). Using a cutoff value of 103.5 pg/mL for the pleural fluid sTREM-1, the sensitivity and specificity were 73% and 81%, respectively, for differentiating parapneumonic effusion from tuberculous or malignant effusions. Conclusion: Pleural fluid sTREM-1 can be an additional marker for making the differential diagnosis of pleural effusion.

Development of a Low-cost Monocular PSD Motion Capture System with Two Active Markers at Fixed Distance (일정간격의 두 능동마커를 이용한 저가형 단안 PSD 모션캡쳐 시스템 개발)

  • Seo, Pyeong-Won;Kim, Yu-Geon;Han, Chang-Ho;Ryu, Young-Kee;Oh, Choon-Suk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.61-71
    • /
    • 2009
  • In this paper, we propose a low-cost and compact motion capture system which enables to play motion games in PS2(Play Station 2). Recently, motion capture systems which are being used as a part in film producing and making games are too expensive and enormous systems. Now days, motion games using common USB camera are slow and have two-dimension recognition. But PSD sensor has a few good points, such as fast and low-cost. In recently year, 3D motion capture systems using 2D PSD (Position Sensitive Detector) optic sensor for motion capturing have been developed. One is Multi-PSD motion capture system applying stereo vision and another is Single-PSD motion capture system applying optical theory ship. But there are some problems to apply them to motion games. The Multi-PSD is high-cost and complicated because of using two more PSD Camera. It is so difficult to make markers having omni-direction equal intensity in Single-PSD. In this research, we propose a new theory that solves aforementioned problems. It can measure 3D coordination if separated two marker's intensity is equal to. We made a system based on this theory and experimented for performance capability. As a result, we were able to develop a motion capture system which is a single, low-cost, fast, compact, wide-angle and an adaptable motion games. The developed system is expected to be useful in animation, movies and games.

Analyzing a Physical Marker to Identify Irradiated Dried Garlic and Cabbage (건마늘과 건양배추의 방사선 조사여부 확인을 위한 물리적 마커 분석)

  • Kim, Dong-Gil;Ahn, Jae-Jun;Jin, Qiong-Wen;Lee, Ho-Cheon;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.136-140
    • /
    • 2009
  • The verification of irradiation treatments, using dried garlic and cabbage treated at 0-20 kGy, was investigated by analyzing the photostimulated luminescence (PSL), electron spin resonance (ESR) and thermoluminescence (TL) characteristics of the samples. The PSL results showed that the photon counts/60 sec of the non-irradiated dried garlic and cabbage were 287-337, corresponding to negative, while those of the irradiated samples were 7511-54063 photon counts/ 60 sec, corresponding to positive, making it possible to discriminate the non-irradiated from the irradiated samples. In ESR analysis, the dried garlic irradiated at 20 kGy exhibited cellulose radicals, whereas the irradiated dried cabbage showed crystalline sugar-induced multi-component signals, which were not found in the non-irradiated samples. The ESR signal intensity significantly increased as the irradiation dose increase ($R^2$= 0.9369 - 0.9926). The TL glow curves of the irradiated samples appeared at a temperature interval of 150-250, which were significantly different from those of non-irradiated samples, showing a significant increase in TL signal intensity with irradiation dose ($R^2$= 0.9670 - 0.9768). To enhance the reliability of the results, the first glow curve ($TL_1$) was compared with the second glow curve ($TL_2$) obtained after a re-irradiation step at 1 kGy. The TL ratio ($TL_1/TL_2$) was in good agreement with the reported TL threshold values for both the non-irradiated (<0.1) and irradiated (> 0.1) samples.

The Usefulness of Serum Tumor Markers as a Predictor of Peritoneal Metastasis in Patients with Gastric Carcinoma: CA 19-9 and CEA (위암 환자에서 수술 전 복막전이 예측을 위한 혈청 종양 표지자의 유용성: CA 19-9와 CEA)

  • Cheong, Oh;Joo, Jae Kyun;Park, Young Kyu;Ryu, Seong Yeop;Jeong, Mi Ran;Kim, Ho Koon;Kim, Dong Yi;Kim, Young Jin
    • Journal of Gastric Cancer
    • /
    • v.8 no.3
    • /
    • pp.129-135
    • /
    • 2008
  • Purpose: The usefulness of serum tumor markers for assessing gastric carcinoma is very limited compared to that for neoplasms in other digestive organs. Many reports have shown that serum tumor markers are closely associated with the prognosis and tumor recurrence in gastric cancer patients. However, little is known about the usefulness of serum tumor markers as a predictor of distant metastasis for gastric carcinoma. Materials and Methods: With excluding the non-specific causes of elevated tumor markers, a total of 788 patients with gastric carcinoma and who were seen at our hospitals between 2004 and 2006 were included in this study. The correlation between the preoperative level of tumor makers and the clinicopathological features was analyzed. Results: CEA was significantly correlated with age, gender and nodal metastasis, but not with the depth of tumor. The CEA level was not correlated with distant metastasis, such as peritoneal or hematogenous metastasis. In contrast, the CA 19-9 level was significantly correlated not only with the depth of tumor and nodal metastasis, but also with peritoneal metastasis. Especially, the patients with over 500% elevation of the CA 19-9 level had a significant risk of peritoneal metastasis. Conclusion: CA 19-9 is useful for predicting peritoneal metastasis in gastric cancer patients. It can be used efficiently in making the diagnostic and the treatment plan, in combination with other diagnostic tools, for gastric cancer patients.

  • PDF

A Study on Establishment of Reference Value of CA 72-4 (CA 72-4 참고치 설정에 관한 연구)

  • An, Jae-Seok;Kim, Ji-Na;Joe, Ye-Ji;Yoon, Sang-Hyuk;Kim, Yoon-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.25-28
    • /
    • 2021
  • Purpose CA 72-4 is a tumor marker that uses two monoclonal antibodies, CC49 and B72.3, to measure tumor-related glycoprotein(TAG72) in the serum. CA 72-4 is used to diagnose stomach, ovarian, and pancreatic cancers, and is known to perform high specificity for stomach cancer. The purpose of this study is to re-evaluate the reference value provided by the manufacturer through revalidation of the reference value in CA 72-4. Furthermore this study was conducted to provide useful help when making a clinical diagnosis at gastric cancer center. Materials and Methods We selected 271 patients who had been to health care center in national cancer center for the month of November 2020. The gender of the subjects was 140 males and 131 females, and the age group was from 30s to 60s. The reagent used in the study was a CA 72-4 IRMA KIT (ISOTOPES, Hungary) and the results were measured using a Dream Gamma-10 gamma counter (Shinjin medics, Korea). Results Statistical analysis of the results of this study used Hoffmann's method and Bayesian's method, which are primarily used in setting reference value. As a result of measuring CA 72-4 of 271 patients, the mean value was 4.54 U/mL and the median value was 3.30 U/mL. 24 people who deviated from 3SD were excluded from the measured value, the mean calculated after that was 3.53 U/mL, median was 3.00 U/mL and SD was 1.89. The reference value calculated based on this results was set to 7.31 U/mL. Conclusion The reference value provided by the manufacturer is less than 4 U/mL. It is slightly different from the value calculated in this study, 7.31 U/mL, so it seems necessary to reset the reference value according to the laboratory environment. Currently, we are receiving inquiries about the reference value from the center for gastric cancer at National Cancer Center. If additional research is carried out along with this study, it will be possible to set more accurate reference value.