• Title/Summary/Keyword: Marine Monitoring

Search Result 1,102, Processing Time 0.026 seconds

The Effects of Starvation on Physiological Changes and Stress Response in Cultured Cobitid Loach (Misgurnus anguillicaudatus) Exposed to Sodium Nitrite

  • Hur, Jun Wook;Gil, Hyun Woo;Park, In-Seok
    • Journal of Marine Life Science
    • /
    • v.3 no.2
    • /
    • pp.87-95
    • /
    • 2018
  • To investigate effects of starvation on physiological changes, stress response, and survival of cobitid loach (Misgurnus anguillicaudatus) exposed to sodium nitrite (NaNO2), a 4-week experiment was conducted. Fewer fish survived in the starved group than those in the fed group during the experiment. Starvation resulted in growth retardation, leading to differences in body length and body depth between fed and starved groups. The fed gorup continued to grow and remained in good condition. Blood chemical analysis (plasma cortisol and glucose) showed significant differences in stress response to nitrite exposure between fed and starved groups (p < 0.05). These results suggest that all parameters employed in this study to assess effects of starvation with NaNO2 stress are useful information for researching nutritional status in cobitid loach.

A Study on the Effectiveness of Flammable Gas Monitoring System in the Cargo Pump Room of Tanker

  • Kim, Mann-Eung;Lee, Kyoung-Woo;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.455-460
    • /
    • 2008
  • The flammable gas monitoring system is to be provided in cargo pump rooms of tankers in accordance with the requirements of SOLAS regulations, and flammable gas detectors are to be arranged in a proper position. In this paper, simulation tests and CFD analysis are carried out under the actual ventilation conditions of pump rooms in the ship in service. Based on the results, a new guidelines for an arrangement of flammable gas detectors are suggested.

Case study of Corrosion Monitoring Sensor for Marine HC Structure (해양콘크리트 구조물의 철근부식 모니터링을 위한 부식센서 고찰)

  • Jang, Bong-Seok;Cha, Hung-Youn;Ahn, Jeong-Hwan;Kim, Bo-Sung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.263-264
    • /
    • 2009
  • This paper presents the example of corrosion monitoring sensor that is applied to massive RC structure exposed to marine environments. Corrosion monitoring sensor is used as an early warning system to predict the initial stage of corrosion in concrete structures. So, it can be a good method to verify the design life and prepare measures for concrete deterioration in advance.

  • PDF

A Data Analysis and RMS Development for Fish-cage in Open Sea (외해 가두리 양식장 데이터 분석 및 원격 감시 시스템 개발)

  • Oh, Jin-Seok;Kwak, Jun-Ho;Jung, Sung-Jae;Ham, Yeon-Jae;Lee, Ji-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.153-161
    • /
    • 2008
  • Recently, the research and development of the fish cage in open sea from domestic is active and it is almost complement with commercial scale test on 'seogwipo'. But domestic technology is not sufficient of management RMS(Remote Monitoring System) with advanced country, so it is difficult to maintenance and monitor fish cage in open sea. This paper introduces a fish cage environmental monitoring system for measuring pH, DO and temperature. A signal is treated with DAU(Data Acquisition Unit) by a wireless communication method and transfers data to host computer for data processing. These data are graphically shown on the monitor with LabVIEW program and logged on the data processing system in the form of file.

The Fault Diagnosis Method of Diesel Engines Using a Statistical Analysis Method (통계적 분석기법을 이용한 디젤기관의 고장진단 방법에 관한 연구)

  • Kim, Young-Il;Oh, Hyun-Kyung;Yu, Yung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.247-252
    • /
    • 2006
  • Almost ship monitoring systems are event driven alarm system which warn only when the measurement value is over or under set point. These kinds of system cannot warn until signal is growing to abnormal state that the signal is over or under the set point. therefore cannot play a role for preventive maintenance system. This paper proposes fault diagnosis method which is able to diagnose and forecast the fault from present operating condition by analyzing monitored signals with present ship monitoring system without any additional sensors. By analyzing the data with high correlation coefficient(CC), correlation level of interactive data can be defined. Knowledge base of abnormal detection can be built by referring level of CC(Fault Detection CC. FDCC) to detect abnormal data among monitored data from monitoring system and knowledge base of diagnosis built by referring CC among interactive data for related machine each other to diagnose fault part.

A study on the Internet control and monitoring system using a microprocessor embedded controller (마이크로프로세서를 이용한 인터넷 원격감시제어 시스템에 관한 연구)

  • 서인호;문복산;김경엽;김영일;천행춘;유영호
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.152-156
    • /
    • 2000
  • Many industrial equipments use RS-232C interface. But Ethernet using CSMA/CD was widly spread recently. This interface is not compatible with RS-232C and requires PC based system. So In this Paper, We decribe a Internet control and monitoring system that control and watch plants without PC. We developed IP controller consisted of microprocessor and NIC and monitoring system using VC++ and SQL database. The protocol used this system is UDP/IP because it is applicable for real time system.

  • PDF

Characteristics of Piezoceramics Sensors for Vibration Detection

  • Tan, A.C.C.;Dunbabin, M.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.285-291
    • /
    • 2004
  • Early detection of an internal malfunction of machinery plays a very important part in all condition monitoring programs. Sensors to detect amplitude. velocity and acceleration are widely used in vibration detection and control. Piezoceramic materials are largely used in sensors and actuators for vibration monitoring and control due to their relatively large output from an induced strain and their arguable self powering characteristics. In this paper a cheap and yet reliable sensors/actuators were developed to detect vibration. The results show that low cost PZT can be designed for optimum detection of bearing vibration. This paper presents the experimental results of a number of piezoceramics characteristics in terms of resonant frequencies and variation of PZT constants with temperature.

A Study on the Internet Control and Monitoring System using an Embedded System (임베디드 시스템을 이용한 인터넷 제어감시 시스템에 관한 연구)

  • Haeng-Choon Chun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.811-817
    • /
    • 2004
  • Recently embedded systems are widely used in various industrial fields as supervisory controller because they have many merits. One of merits seems to be that operating environment of embedded system is the same as development environment using PC. That makes developing and manufacturing period shorten and also proper time to market Most of all machinery have sequential control system for their maneuvering which is composed of relays. contacts. timers. etc. In this paper. software sequential control system is proposed to be able to replace hardware sequential control system by using embedded system A lot of merits by the software sequential control system can be expected in the respect of economic reproduction, intelligent technologies and utilities, And porting of LINUX operating system to embedded system is carried out and device drivers and interface boards for LINUX 05 are designed for controlling air compressor by software Internet remote control and monitoring system of air compressor is implemented with Java script and CGI for these purposes. The experiment for operating air compressor system is taken through internet networks. The results show that developed system can be used for real plant.

A Study on Development of Internet Based Power Management System Using a Microprocessor (마이크로프로세서를 이용한 인터넷기반 전력관리시스템 개발에 관한 연구)

  • 천행춘
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.746-753
    • /
    • 2004
  • In this paper, the Power Management System(PMS) which based on a decision making system according to power strategy is proposed and implemented. PMS is designed to have functions of power monitoring. controlling, synchronizing load sharing and monitoring of driving engine, etc. PMS consists of the internet communication system(ICS). Remote Management System(RMS) and Sensor Driver System (SDS) ICS transmits the monitoring and supervisory data via Internet to Remote Management System(RMS) in real-time SDS detects various power system data on local generator and utility via I/O interface system. I/O interface system receives various status data and outputs control signals. Implemented PMS is tested with dummy signal to verify proposed functions and shows good results. For future study implemented PMS will be tested under real load condition to merchandize.

The Fault Diagnosis Method of Diesel Engines Using a Statistical Analysis Method (통계적분석기법을 이용한 디젤기관의 고장진단 방법에 관한 연구)

  • Kim, Young-Il;Oh, Hyun-Gyeong;Cheon, Hang-Chun;Yu, Yung-Ho
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.281-286
    • /
    • 2005
  • Almost ship monitoring systems are event driven alarm system which warn only when the measurement value is over or under set point. These kinds of system cannot warn while signal is growing to abnormal state until the signal is over or under the set point and cannot play a role for preventive maintenance system. This paper proposes fault diagnosis method which is able to diagnose and forecast the fault from present operating condition by analyzing monitored signals with present ship monitoring system without additional sensors. By analyzing this data having high correlation coefficient(CC), correlation level of interactive data can be understood. Knowledge base of abnormal detection can be built by referring level of CC(Fault Detection CC, FDCC) to detect abnormal data among monitored data from monitoring system and knowledge base of diagnosis built by referring CC among interactive data for related machine each other to diagnose fault part.

  • PDF