A Study on the Effectiveness of Flammable Gas Monitoring System in the Cargo Pump Room of Tanker  

Kim, Mann-Eung (Energy & Industrial Technology Center, Korean Register of Shipping)
Lee, Kyoung-Woo (Energy & Industrial Technology Center, Korean Register of Shipping)
Lee, Young-Ho (Division of Mechanical & Information Engineering, Korea Maritime University)
Abstract
The flammable gas monitoring system is to be provided in cargo pump rooms of tankers in accordance with the requirements of SOLAS regulations, and flammable gas detectors are to be arranged in a proper position. In this paper, simulation tests and CFD analysis are carried out under the actual ventilation conditions of pump rooms in the ship in service. Based on the results, a new guidelines for an arrangement of flammable gas detectors are suggested.
Keywords
Cargo pump room; Upper flammable limit (UFL); Lower flammable limit (LFL); Flammable gas monitoring system;
Citations & Related Records
연도 인용수 순위
  • Reference
1 "International Convention for the Safety of Life at Sea", IMO, 2006 Consolidated Edition, IMO, 2006