• Title/Summary/Keyword: Marginal gap

Search Result 162, Processing Time 0.023 seconds

Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis

  • Park, Jin-Young;Bae, So-Yeon;Lee, Jae-Jun;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.159-169
    • /
    • 2017
  • PURPOSE. The purposes of this study were to evaluate the marginal and internal gaps, and the potential clinical applications of three different methods of dental prostheses fabrication, and to compare the prostheses prepared using the silicone replica technique (SRT) and those prepared using the three-dimensional superimposition analysis (3DSA). MATERIALS AND METHODS. Five Pekkton, lithium disilicate, and zirconia crowns were each manufactured and tested using both the SRT and the two-dimensional section of the 3DSA. The data were analyzed with the nonparametric version of a two-way analysis of variance using rank-transformed values and the Tukey's post-hoc test (${\alpha}=.05$). RESULTS. Significant differences were observed between the fabrication methods in the marginal gap (P < .010), deep chamfer (P < .001), axial wall (P < .001), and occlusal area (P < .001). A significant difference in the occlusal area was found between the two measurement methods (P < .030), whereas no significant differences were found in the marginal gap (P > .350), deep chamfer (P > .719), and axial wall (P > .150). As the 3DSA method is three-dimensional, it allows for the measurement of arbitrary points. CONCLUSION. All of the three fabrication methods are valid for measuring clinical objectives because they produced prostheses within the clinically acceptable range. Furthermore, a three-dimensional superimposition analysis verification method such as the silicone replica technique is also applicable in clinical settings.

MARGINAL FIDELITY ACCORDING TO THE MARGIN TYPES OF ALL CERAMIC CROWNS (전부도재관의 변연형태에 따른 변연적합도에 관한 연구)

  • Koo, Jae-Yong;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.3
    • /
    • pp.445-457
    • /
    • 1997
  • Poor marginal fidelity resulting in a large marginal gap increases plaque accumulation, gingival inflammation and dental caries. The purpose of this study was to evaluate the marginal fit of three different cervical finishing methods of prepared teeth. A stereomicroscope was used to measure the space between the margin of restoration and the finishing line of prepared tooth. The results were statistically analyzed using the ANOVA and Multiple Range Test(Tukey's HSD). The results were as follows : 1. There were no significant differences concerning the types of tooth and positon (P>0.05), whereas the differences were statistically significant in case of cervical finishing methods (P<0.05). 2. There were statistically significant differences between before and after cementation (P<0.05). 3. In comparison according to variable margins after cementation, the gap discrepancies were increased in $130^{\circ}$ shoulder margin, chamfer margin and $90^{\circ}$ shoulder margin in ascending order, and there were significant differences between $90^{\circ}$ shoulder margin and chamfer, $130^{\circ}$ shoulder margin 4. In comparison according to variable margins, the gap discrepancies were increased in chamfer margin, $130^{\circ}$ shoulder margin and $90^{\circ}$ shoulder margin in ascending order, and there were significant differences between $90^{\circ}$ shoulder margin and chamfer, $130^{\circ}$ shoulder margin. 5. This study demonstrated a better marginal fit with all-ceramic crowns fabricated on chamfer and $130^{\circ}$ shoulder margin compared with $90^{\circ}$ shoulder margin.

  • PDF

Optional Tariffs for Channel Coordination

  • Song, Jae-Do
    • Asia Marketing Journal
    • /
    • v.14 no.3
    • /
    • pp.49-68
    • /
    • 2012
  • When a channel is vertically separated, there can be inefficiencies, double marginalization. Channel coordination to amend this inefficiency has been an important issue in marketing and economics. Channel coordination deals with maximization of joint profit and achieving proper profit sharing among participants. In this paper, a manufacturer and heterogeneous multiple retailers with exclusive territory are assumed, and channel coordination with two-part tariff is considered. When multiple heterogeneous retailers are assumed, profit sharing can be an issue even though the tariffs based on marginal cost can maximize joint profit. In case of multiple heterogeneous retailers, the manufacturer earns the same profit (fixed fee) from each retailer. This means that a large retailer occupies all the gaps of channel profit between small and large markets. Then, the manufacturer, which generally plays the role of Stackelberg leader, will consider increasing fixed price or marginal price to earn more profit from large retailer. Those reactions can sacrifice maximization of joint profit by making small retailer withdraw or by changing the sales quantities. In this paper, to maximize joint profit and achieve proper profit sharing, two kinds of optional tariffs are considered. The first is an optional two-part tariff based on marginal cost and the second is an optional modified two-part tariff in which marginal prices are higher than the manufacturer's marginal cost. In both types of optional tariffs, maximization of joint profit in each market can be achieved. Moreover, optional tariffs alleviate the problem of profit sharing. Optional tariffs can provide a manufacturer more profit from a large retailer when profit from a small retailer is given. However, the analysis shows that the maximum share of manufacturer from a large retailer is restricted by the condition for self-selection. In case of optional two-part tariffs based on marginal cost, if the gap between demands is large, the maximum share of the manufacturer is sufficient to achieve proper profit sharing. If the gap between demands is not sufficiently large, the manufacturer cannot earn sufficient share from increased profit. An optional modified two-part tariff where marginal price is more than marginal cost of manufacturer is considered because of this scenario. The marginal price above the marginal cost may additionally control the distribution of the increased profit. However, the analysis shows that a manufacturer's maximum profit from a large retailer with given profit from a small retailer is the same as or lower than the maximum profit when optional two-part tariffs based on marginal cost are applied. Therefore, it can be concluded that the optional modified tariffs do not have additional contribution to profit sharing relative to the tariffs based on marginal cost. Although this paper does not cover all kinds of optional tariffs that are different from tariffs based on marginal cost, it shows the advantage of optional tariffs based on marginal cost and has important theoretical implications. The result of this paper also gives guide for channel coordination. Optional two-part tariff based on marginal cost can increase efficiency in channel coordination.

  • PDF

Analyzing the Impact of Inventory Management Performance on the Energy Efficiency in Korean Petrochemical Companies (재고관리성과가 에너지효율성에 미치는 영향에 대한 실증분석 : 국내 석유화학 기업을 대상으로)

  • Kim, Gilwhan;Lee, Jiwoong
    • Korean Management Science Review
    • /
    • v.34 no.3
    • /
    • pp.1-14
    • /
    • 2017
  • This study empirically analyzes the impact of inventory management performance on the energy efficiency in Korean petrochemical companies. The concept of the distance function is used to define the energy efficiency and the estimation of the distance function is performed using the stochastic frontier analysis. The inventory turnover is selected as the variable indicating the inventory management performance of the company. The main results of this study are as follows. First, the inventory turnover has a positive impact on energy efficiency. Second, during the period over 2011~2015, while the gap in energy efficiency among the companies expanded, the average energy efficiency decreased. Third, the average energy efficiency in upstream process companies was greater than downstream process companies and the gap in energy efficiency among downstream process companies was greater than upstream process companies. Fourth, the average marginal effect of inventory turnover on energy efficiency increased gradually from 2011 to 2015. Finally, the average marginal effect of inventory turnover in downstream process companies was greater than upstream process companies, and the gap in the marginal effect of inventory turnover among downstream process companies was greater than upstream process companies. These results together imply the importance of inventory management in terms of energy efficiency.

A STUDY ON MARGINAL ADAPTATION OF READY-MADE STAINLESS STEEL CROWN TO THE PRIMARY MOLAR (기성금관수복 유구치의 변연 적합도에 관한 연구)

  • Lee, Sun-Kyung;Lee, Gwang-Su;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.389-400
    • /
    • 1996
  • In Class II amalgam restoration in deciduous molar, failure rate and incidence of recurrent caries are high as children become older. In order to preserve deciduous molars till the physiologic exfoliation time, stainless steel crown is a choice of the treatment. As a result of a careless treatment, such as overhanging margin, poor marginal adaptation, poor proximal contour and inadequate mesiodistal width give rise to interfering eruption of the adjacent teeth, recurrent caries and chronic gingival irritation and insufficient arch length respectively. In this study, 252 s.s. crowned teeth extracted due to physiologic exfoliation or periapical lesion. The purpose of this study is to analyze the marginal adaptation of stainless steel crown to the deciduous molar in order to obtain better clinical result. The results were as follows : 1. Between the length of s.s. crown and the marginal gap of crown, positive correlations were shown. 2. Largest amount of marginal gap was shown at buccal side in upper deciduous molars and lower first deciduous molar, lingual side in lower second deciduous molar. But no significant diffrence were found statistically compared to second most largest one. 3. Incidence of exposed restoration and recurrent caries were higher in proximal surface than buccal/lingual surface. And extension of restoration below the margin of s.s. crown gives rise to higher rate of recurrent caries. 4. Defect of contour was found in 34%, frequently found in lower 1st deciduous molar and upper 1st deciduous molar. 5. Marginal polishing defects were found in 23%. 6. Ledge was formed in 10% especially in lower 1st deciduous molar and lower 2nd deciduous molar. 7. 16% of the teeth had wear facet due to traumatic occlusion, 7% of them had occlusal perforation.

  • PDF

An evaluation of quality of dental prostheses printed by dental 3-dimensional printing system (치과용 3D 프린팅 시스템에 의해 출력된 보철물의 품질 평가)

  • Han, Man-So
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.185-191
    • /
    • 2016
  • Purpose: The purpose of this study were to evaluate the quality of dental prostheses printed by 3-dimensional printing system. Methods: Mater model was prepared and ten study models were fabricated. Ten single crowns were printed by 3D-printing system(Resin group) and another ten single crowns using casting method were manufactured(Metal group). The marginal adaptation of single crowns were measured using by silicone replica technique. Silicone replicas were sectioned four times. The marginal adaptations were evaluated using by digital microscope. Statistical analyses were performed with Mann-Whitney test(${\alpha}=0.05$). Results: $Mean{\pm}standard$ deviations of all marginal adaptations were $92.1(20.0){\mu}m$ for Metal group and $69.7(12.3){\mu}m$ for Resin group. Two groups were no statistically significant differences(p>0.05). Conclusion: Marginal adaptation of single crowns printed by 3D-printing system were ranged within the clinical recommendation.

MARGINAL ADAPTATION OF STAINLESS STEEL IN POSTERIOR PRIMARY TOOTH (유구치 기성 금관의 변연 적합도에 관한 연구)

  • Woo, Jue-Hyung;Jang, Chul-Ho;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.27-35
    • /
    • 2007
  • Stainless steel crowns are invaluable restorative material for the treatment of badly broken down primary teeth in pediatric dentistry. But it is difficult to fit margin because selection of size is not easy and they are not adjusted for Korean children. The purpose of this study was to examine and analyze the marginal adaptation of stainless steel crown of posterior primary tooth. Marginal surface was taken by Fine Pix S602 digital camera and measurements of crown were recorded at 20 points that were randomly selected for marginal gap evaluation by Kappa image base program. 1. Mean marginal gap were large upper 2nd primary molar, lower 1st primary molar, lower 2nd primary molar, upper 1st primary molar in order(p<0.05). 2. Mean marginal surface dimension ratio was more than 20% irrespective of tooth. 3. Largest amount of marginal gap was shown at mesial surface in upper 1st, 2nd primary molar and distolingual surface in lower 1st primary molar, buccal surface in lower 2nd primary molar.

  • PDF

Effects of Property Transformation and Marginal Gap Depending on Heat-Treatment of Metal-Porcelain by Gold Electro-Forming System (전기성형법을 이용한 치과용 금속-도재관의 소성에 따른 물성 변화가 변연 간격에 미치는 영향)

  • Kim, Chi-Young;Chung, In-Sung;Choi, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.352-359
    • /
    • 2010
  • The objective of this paper is to study on the property transformation for materials and to evaluate the precision through marginal gap depending on heat-treatment of metal-porcelain by the gold electro-forming system. Specimens for evaluating property of hardness treat non-treat(HC), once(H1), twice(H2), and three times(H3) by heating, respectively. Specimens for marginal gap classified as each groups of special bonder(FS), special bonder, opaque(FO), special bonder, opaque, body(FB) and non-treatment(FC). As a result for micro-hardness test, the level of hardness on each groups of H1, H2, H3 decreased rather than HC group(p<0.05). In addition, marginal gap was not affected by the number of times being treated by heating. Therefore, the marginal fitness and the precision for mterials were not affected by the heat-treatment on the process to make GES metal-porcelain.

Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems

  • Eun-Bin Bae;Won-Tak Cho;Do-Hyun Park;Su-Hyun Hwang;So-Hyoun Lee;Mi-Jung Yun;Chang-Mo Jeong;Jung-Bo Huh
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.155-170
    • /
    • 2023
  • PURPOSE. This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS. Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS. There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 ㎛ but there was no statistically significant difference within the groups (P > .05). CONCLUSION. All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 ㎛ in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown.

MARGINAL FITNESS AND MARGINAL LEAKAGE OF FIBER-REINFORCED COMPOSITE CROWNS DEFENDING UPON LUTING CEMENTS (섬유강화형 복합레진전장관의 변연적합도 및 변연누출에 관한 연구)

  • Kim, Sun-Jong;Shin, Sang-Wan;Han, Jung-Suk;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.618-630
    • /
    • 2000
  • As Fiber-reinforced composite restorations cannot be made without leaving a marginal gap, luting cements play a pivotal role in sealing the margins as a prevention against margnal leakage. A recently introduced adhesive resin cement system is claimed to adhere chemically, as well as mechanically, to tooth substances, dental alloys and porcelain. But when considering the clinical variation conventional cementation using Zinc Phosphate and Glass-Ionomer can be requested. A vitro study was undertaken to compare microleakage and marginal fitness of Fiber-reinforced composite crowns(Targis/Vectris) depending upon luting cements. Fifty non-carious human premolar teeth were randomly divided into five experimental groups of 10 teeth each and luted with five luting cements. ($Bistite\;II^(R),\;Super-bond^(R),\;Variolink\;II^(R)$), Zinc phosphate and Glass-Ionomer cement) After 24 hours of being luted, all specimens were thermocycled 300 times through water bath of $5^{\circ}C\;and\;55^{\circ}C$ in each bath, then the quality of the marginal fitness was measured by the Digital Microscope and marginal leakage was characterized using Dye Penetration technique and the Digital Microscope The results were as follows : 1. The mean values of marginal fit were Bistite II($46.78{\mu}m$), Variolink II($56.25{\mu}m$), Super-Bond($56.78{\mu}m$), Glass-Ionomer($99.21{\mu}m$), Zinc Phosphate($109.49{\mu}m$) indicated a statistically significant difference at p<0.001. 2. The mean microleakage values of tooth-cement interface, restoration-cement interface were increased in the order of Variolink II, Bistite II, Super-Bond, Glass-Ionomer, Zinc Phosphate 3. Crowns luted with resin cement (Bistite II, Super-Bond, Variolink II, etc) exhibited less marginal gap and marginal leakage than those luted with conventional Glass-Ionomer and Zinc Phosphate cement. 4. The results indicated that all five luting systems yielded comparable and acceptable marginal fit.

  • PDF