• Title/Summary/Keyword: Marginal Fitness

Search Result 56, Processing Time 0.024 seconds

Climatic Changes and Geographical Characteristics of Solar Term Temperatures in the Korean Peninsula (한반도 절기 기온의 기후적 변화와 지리적 특성)

  • PARK, Sun-Yurp;LEE, Su-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.3
    • /
    • pp.65-81
    • /
    • 2019
  • The twenty-four Solar Terms are Chinese traditional astronomical divisions that describe seasonal cycles of the year. Based on the analyses of meteorological data during 1979~2018, study results showed that the temperatures of the Solar Terms had increased in general in the Korean Peninsula. In North Korea, temperature increases were observed on 21 Solar Terms, and their seasonal mean temperatures were increased by $0.87^{\circ}C$, $1.19^{\circ}C$, $1.45^{\circ}C$, and $0.64^{\circ}C$ on average in spring, summer, fall, and winter, respectively. The duration of summer has lengthened due to the temperature rise in fall, and the magnitude of temperature change was greater in summer compared to winter. As for South Korea, increases in temperature were observed on 18 Solar Terms, and the temperature changes were more pronounced in fall and winter than spring and summer. The Great Snow temperature decreased more than any other Solar Terms during the study period, and this temperature change was observed both in North and South Koreas. The Great Cold, which represents the coldest day of the year, showed a significant temperature increase of $3.08^{\circ}C$, while the Slight Heat had a marginal temperature increase of $0.29^{\circ}C$. The hottest day and the first day of frost tended to come later than the Great Heat and the Frost's Decent. By contrast, the coldest day tended to occur later than the Great Cold in the study area. On average over the entire study period, the climatic fitness of the Great Heat and the Frost's Decent was higher in North Korea, and that of the Great Cold was higher in South Korea, respectively.

Effects of a High Protein Diet and Aerobic Exercise on Body Weight Changes and Blood Lipids in Slightly Overweight Women

  • Suh, Kyoung Yeo;Lee, Dae Taek
    • Nutritional Sciences
    • /
    • v.8 no.1
    • /
    • pp.28-34
    • /
    • 2005
  • To examine the combined effects of a high-protein diet and aerobic exercise on body weight and composition and blood lipid profiles in overweight women, 30 young women were recruited and placed into three groups: The high-protein diet and exercise group (HPE), the exercise-only group (EXO) and the control group (CON) (30$\pm$3%, 27$\pm$2%, and 29$\pm$3% body fat, respectively) for an 8-week experimental period. Daily diet included 25% isolated soybean protein (>90% protein, approximately 400 kcal) combined with each subject s usual diet for the HPE group. The exercise program consisted of aerobic-type exercises undertaken >3 times/wk and for>30 min/session at 50-60% of maximal capacity. Physical fitness, body composition, serum total cholesterol (TC), high-density lipoprotein-cholesterol (HDL-C), triglycerides (TG) and glucose were measured before and after the experiment. Maximal aerobic capacity increased by the end of experiment in both the HPE (from 27.2$\pm$3.5 to 35.l$\pm$5.9 ml/kg/min, p<0.01) and EXO (from 30.3$\pm$5.4 to 33.8$\pm$3.8 mㅣ/kg/min, p<0.05) groups. Percent body fat decreased by 3.3% (p<0.01) in the HPE group and by 1.5% (p<0.05) in the EXO group by the end of the experiment, but not in the CON group. Lower back strength and agility increased only in the HPE group. In the HPE group, TC decreased from 168$\pm$20 to 155$\pm$18 mg/dL and HDL-C increased from 57$\pm$l0 to 61$\pm$9 mg/dL in HPE (p<0.01). But TC and HDL-C did not change in the EXO and CON groups. TG and glucose did not vary among the groups. Although the EXO group showed a similar outcome to that of the HPE group, a favorable change in body composition and blood lipids as well as an improvement in aerobic capacity was more marginal in the latter group.

A Study on the Prediction of Power Consumption in the Air-Conditioning System by Using the Gaussian Process (정규 확률과정을 사용한 공조 시스템의 전력 소모량 예측에 관한 연구)

  • Lee, Chang-Yong;Song, Gensoo;Kim, Jinho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.1
    • /
    • pp.64-72
    • /
    • 2016
  • In this paper, we utilize a Gaussian process to predict the power consumption in the air-conditioning system. As the power consumption in the air-conditioning system takes a form of a time-series and the prediction of the power consumption becomes very important from the perspective of the efficient energy management, it is worth to investigate the time-series model for the prediction of the power consumption. To this end, we apply the Gaussian process to predict the power consumption, in which the Gaussian process provides a prior probability to every possible function and higher probabilities are given to functions that are more likely consistent with the empirical data. We also discuss how to estimate the hyper-parameters, which are parameters in the covariance function of the Gaussian process model. We estimated the hyper-parameters with two different methods (marginal likelihood and leave-one-out cross validation) and obtained a model that pertinently describes the data and the results are more or less independent of the estimation method of hyper-parameters. We validated the prediction results by the error analysis of the mean relative error and the mean absolute error. The mean relative error analysis showed that about 3.4% of the predicted value came from the error, and the mean absolute error analysis confirmed that the error in within the standard deviation of the predicted value. We also adopt the non-parametric Wilcoxon's sign-rank test to assess the fitness of the proposed model and found that the null hypothesis of uniformity was accepted under the significance level of 5%. These results can be applied to a more elaborate control of the power consumption in the air-conditioning system.

Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system

  • Lee, Wan-Sun;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.265-270
    • /
    • 2017
  • PURPOSE. This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS. The discrepancy means (standard deviation) of the 3 groups are $171.6\;(97.4){\mu}m$ for the crown manufactured by the milling system and 149.1 (65.9) and $91.1\;(36.4){\mu}m$, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.

Implant prosthesis for fully edentulous patients using intra-oral scanning and abutment merging technique: A case report (무치악 환자에서 구강 스캔과 지대주 중첩을 이용한 임플란트 보철수복 증례)

  • Hwang, Chan-Hyeon;Jeong, Seung-Mi;Kim, Yong-Jun;Kim, Kyeong-Hee;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.61-70
    • /
    • 2017
  • In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.

A comparative study on the fit and screw joint stability of ready-made abutment and CAD-CAM custom-made abutment (기성 지대주와 맞춤형 CAD-CAM 지대주의 적합 및 나사 안정성 비교)

  • Kim, Jong-Wook;Heo, Yu-Ri;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.276-283
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the fit and screw joint stability between Ready-made abutment and CAD-CAM custom-made abutment. Materials and methods: Osstem implant system was used. Ready-made abutment (Transfer abutment, Osstem Implant Co. Ltd, Busan, Korea), CAD-CAM custom-made abutment (CustomFit abutment, Osstem Implant Co. Ltd, Busan, Korea) and domestically manufactured CAD-CAM custom-made abutment (Myplant, Raphabio Co., Seoul, Korea) were fabricated five each and screws were provided by each company. Fixture and abutments were tightening with 30Ncm according to the manufacturer's instruction and then preloding reverse torque values were measured 3 times repeatedly. Kruskal-Wallis test was used for statistical analysis of the preloading reverse torque values (${\alpha}=.05$). After specimens were embedded into epoxy resin, wet cutting and polishing was performed and FE-SEM imaging was performed, on the contact interface. Results: The pre-loading reverse torque values were $26.0{\pm}0.30Ncm$ (ready-made abutment; Transfer abutment) and $26.3{\pm}0.32Ncm$ (CAD-CAM custom-made abutment; CustomFit abutment) and $24.7{\pm}0.67Ncm$ (CAD-CAM custom-made abutment; Myplant). The domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) presented lower pre-loading reverse torque value with statistically significant difference than that of the ready-made abutment (Transfer abutment) and CAD-CAM custom-made abutment (CustomFit abutment) manufactured from the same company (P=.027) and showed marginal gap in the fixture-abutment interface. Conclusion: Within the limitation of the present in-vitro study, in domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) showed lower screw joint stability and fitness between fixture and abutment.