• Title/Summary/Keyword: Manual Exposure Control

Search Result 37, Processing Time 0.029 seconds

Role of Oxytocin in Post-traumatic Stress Disorder: A Systematic Review (외상 후 스트레스 장애에 대한 옥시토신의 역할: 체계적 문헌 고찰)

  • Oh, Jaeuk;Kim, Minsu;Chu, Sang Hui
    • Journal of Korean Biological Nursing Science
    • /
    • v.24 no.1
    • /
    • pp.1-16
    • /
    • 2022
  • Purpose: Recently, oxytocin has been introduced experimentally as a pharmacological treatment for post-traumatic stress disorder (PTSD). This study attempted to investigate the possibility of oxytocin as a treatment option for patients with PTSD by examining its dose, interval, and effectiveness in patients with PTSD. Methods: A systematic review was done on articles published from 1967 to 2020 using the PubMed, PsycINFO, and Cochrane databases. Our inclusion criteria were 1) subjects 18 years of age or older diagnosed with PTSD or exposed to a traumatic event that met criterion A of the Diagnostic and Statistical Manual of Mental Disorders (DSM) for PTSD, 2) oxytocin was administered at least once, 3) clinical trials, and 4) studies published in Korean or English. Two independent researchers reviewed 22 articles and recorded the contents. The risk of bias was evaluated to determine the quality of the reviewed article. Results: The parameters for evaluating the effectiveness of oxytocin were identified as socio-behavioral measures in 11 articles, neuronal imaging in 9, and biomarkers in 4. In 5 papers, oxytocin was administered multiple times. Socio-behavioral measures were improved in 3 out of 5 studies in which oxytocin was administered multiple times. In 2 studies in which prolonged exposure treatment and nasal oxytocin administration were combined for 10 weeks, patient symptoms were decreased compared to the control group. Conclusion: The possibility of oxytocin as an adjuvant treatment for PTSD psychotherapy was confirmed. Further studies are necessary to evaluate the long term effectiveness of administering oxytocin multiple times combined with psychotherapy.

Survery on Business of the Departments of Radiology in Health Centers (보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究))

  • Choi, Jong-Hak;Jeon, Man-Jin;Huh, Joon;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF

Progress of Composite Fabrication Technologies with the Use of Machinery

  • Choi, Byung-Keun;Kim, Yun-Hae;Ha, Jin-Cheol;Lee, Jin-Woo;Park, Jun-Mu;Park, Soo-Jeong;Moon, Kyung-Man;Chung, Won-Jee;Kim, Man-Soo
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.3
    • /
    • pp.185-194
    • /
    • 2012
  • A Macroscopic combination of two or more distinct materials is commonly referred to as a "Composite Material", having been designed mechanically and chemically superior in function and characteristic than its individual constituent materials. Composite materials are used not only for aerospace and military, but also heavily used in boat/ship building and general composite industries which we are seeing increasingly more. Regardless of the various applications for composite materials, the industry is still limited and requires better fabrication technology and methodology in order to expand and grow. An example of this is that the majority of fabrication facilities nearby still use an antiquated wet lay-up process where fabrication still requires manual hand labor in a 3D environment impeding productivity of composite product design advancement. As an expert in the advanced composites field, I have developed fabrication skills with the use of machinery based on my past composite experience. In autumn 2011, the Korea government confirmed to fund my project. It is the development of a composite sanding machine. I began development of this semi-robotic prototype beginning in 2009. It has possibilities of replacing or augmenting the exhaustive and difficult jobs performed by human hands, such as sanding, grinding, blasting, and polishing in most often, very awkward conditions, and is also will boost productivity, improve surface quality, cut abrasive costs, eliminate vibration injuries, and protect workers from exposure to dust and airborne contamination. Ease of control and operation of the equipment in or outside of the sanding room is a key benefit to end-users. It will prove to be much more economical than normal robotics and minimize errors that commonly occur in factories. The key components and their technologies are a 360 degree rotational shoulder and a wrist that is controlled under PLC controller and joystick manual mode. Development on both of the key modules is complete and are now operational. The Korean government fund boosted my development and I expect to complete full scale development no later than 3rd quarter 2012. Even with the advantages of composite materials, there is still the need to repair or to maintain composite products with a higher level of technology. I have learned many composite repair skills on composite airframe since many composite fabrication skills including repair, requires training for non aerospace applications. The wind energy market is now requiring much larger blades in order to generate more electrical energy for wind farms. One single blade is commonly 50 meters or longer now. When a wind blade becomes damaged from external forces, on-site repair is required on the columns even under strong wind and freezing temperature conditions. In order to correctly obtain polymerization, the repair must be performed on the damaged area within a very limited time. The use of pre-impregnated glass fabric and heating silicone pad and a hot bonder acting precise heating control are surely required.

Analysis of Factors Related to Pain Relief on Modified Mammography (변형 유방촬영술시 통증완화에 따른 요인 분석)

  • Jang, Myung Mi;Kim, Hwa Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.413-421
    • /
    • 2017
  • Mammography, the basic test for finding and treating increased breast cancer, gives the anxiety of cancer and radiation exposure to most women. In addition, it gave very severe compression pain, so we studied the degree of pain and tried to reduce the pain. The purpose of this study is to compare and analyze the modified imaging technique and the basic imaging technique based on clinical experience, respectively. The subjects of this study were 160 women from 30 to 60 years old who visited to Seoul Boramae Hospital operated by Seoul National University Hospital from February to March 2017 for breast screening. Modified 80 persons and 80 persons were divided into two groups, and each group was asked to fill out questionnaires sequentially without knowing the subjects. The first method is a modified method in which an automatic pedal is divided into four or more presses, a manual pressure is used together, and an attitude is described in detail. Secondly, we used only the automatic pedal compression method and press it within 1-3 times. In the mean of the pain distribution, the experimental group (modified method) was 2.49 and the control group (basic method) had an average of 4.86, which showed 48.8% less pain. In this modified method, the pain scores of the experimental group were lower than those of the control group, and the degree of the pain was statistically significant.

The Effects of Extracts from Ginseng, Wormwood and Pine needle in Pulmonary Structure and Anti-oxidant Enzyme in Smoking (흡연 시 인삼, 쑥, 솔잎 추출물이 폐 세포의 구조와 항산화 효소에 미치는 영향)

  • Jung, Hyuk;Kim, Sang-Ki;Kim, Sang-Guk;Sung, Mi-Young;Kim, Hyun-Jung;Kim, Bum-Hak;Kim, Yu-Young
    • KSBB Journal
    • /
    • v.19 no.2
    • /
    • pp.138-142
    • /
    • 2004
  • Cigarette smoke causes atypical structure of pulmonary (cell structural) and oxidative damage. Therefore, we carried out to determine if exposure to cigarette smoke alters pulmonary structure and anti-oxidant related enzyme in a ICR mice model, when natural product extracts using by manual sprayer. The mice were divided into five groups, control group, sham-treated group (Sham), natural product extracts-treated group (NPE), natural product extracts-treated with smoke-exposed group (NPE-SM) and smoke-exposed (SM) group. All groups are similar to control group in weight, but SM group is lower than the other groups. Microscopic image of the pulmonary structure in SM group showed deleterious alterations in the morphology, but the other groups are maintained in original structure. In anti-oxidant related enzyme, SOD (superoxide dismutase) and catalase, SM group represents the lowest enzyme activity among all groups. These results indicate that the natural product extracts is an efficient tissue protective agent against smoke-induced lung injury.

MONOMER RELEASE FROM PIT AND FISSURE SEALANT FOLLOWING BY SURFACE TREATMENT AND CURING TIME (치면열구전색제의 표면처리와 중합시간 증가에 따른 미반응 모노머 용리 평가)

  • Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.122-129
    • /
    • 2007
  • The purpose of this study was to evaluate the effects of a various light curing time on the residual monomers released from light-cured dental sealant, and to examine the effectiveness of surface treatment in reducing the oxygen-inhibited layer of light-cured dental sealant($Helioseal^{(R)}$ F, Vivadent, Liechtenstein). Specimens were cured with a halogen light curing unit(XL 3000, 3M, USA) for 20, 40, 60s. Surface treatment of a light-cured dental sealant included no treatment(control group), a 10-seconds exposure to distilled water(Group I), 10-seconds manual application using a cotton pellet wetted with 75% alcohol(Group II), and 10-seconds application of a water/pumice slurry using a rubber cup on a slow-speed handpiece The specimens were eluted in distilled water for 10 minutes. All elutes were analyzed by HPLC for identification and quantitive analysis of monomers. The results of this study can be summarized as follows. 1. None of the chromatograms of the tested sealant displayed peaks with the same retention time as that of the standard solution, except for TEGDMA. 2. The release of TEGDMA decreased with increasing curing time in conventional halogen light. 3. All surface treatment group had a decrease of monomer release in comparison with no treatment group. 4. Treatment that Group III eliminated the greatest amount of any type of residual monomers. 5. The elution of unreacted monomers from curing with halogen curing unit for 60s and Group III was less than other groups.

  • PDF

COMPARISON OF MONOMER RELEASE FROM PIT AND FISSURE SEALANT FOLLOWING VARIOUS SURFACE TREATMENT (치면열구전색제의 광중합 후 표면 처리 방법에 따른 미반응 모노머 용리 비교)

  • Lee, Sang-Woo;Lee, Ju-Hyun;Seo, Hyun-Woo;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.70-76
    • /
    • 2006
  • The aim of this study was comparison of effectiveness of surface treatment methods in reducing the oxygen-inhibited layer of a commercially available freshly polymerized, light cured dental sealant($concise^{TM}$, 3M, St Paul, USA). Surface treatment groups were consisted of no treatment(negative control group) and 3 experimental groups according to surface treatment of light-cured sealant. Experimental group I was 10 seconds' exposure to distilled water syringe, group II was 10 seconds' manual application using a cotton pellet wetted with 75% alcohol and group III was 10 seconds' prophylaxis with pumice/water slurry using rubber cup on a slow-speed handpiece. All specimens were immersed in 5ml distilled water and stored at 37c water bath for 10 minutes. All eluates were analyzed by HLPC for identification and quantitive analysis of monomers. The results of this study can be summarized as follows. 1. None of the chromatograms of the tested sealant displayed peaks with the same retention time as that of the standard solution, except for TEGDMA. 2. All surface treatment group had a statistically significant decrease of monomer release in comparison with no treatment group. 3. Removal effects of unreacted monomer in group III was statistically significant in comparison with group I and group II. These results revealed that mechanical method using pumice and rubber cup is the most effective in removing residual monomer and may be valuable to be used effectively in clinic.

  • PDF