• Title/Summary/Keyword: Manual Exposure Control

Search Result 37, Processing Time 0.057 seconds

Radiation Dose Reducing Effect during the AEC System in the Chest and Abdomen of the MDCT Scanning (흉부 및 복부에서 AEC 적용에 따른 MDCT의 선량 감소 효과)

  • Lee, Jong-Seok;Kweon, Dae-Cheol;You, Beong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.225-231
    • /
    • 2009
  • The purpose of the current study was to compare radiation dose of 64MDCT performed with automatic exposure control (AEC) with manual selection fixed tube current. We evaluated the CT scans of phantom of the chest and abdomen using the fixed tube current and AEC technique. Objective image noise shown as the standard deviation of CT value in Hounsfield units was measured on the obtained images. Compared with fixed tube current, AEC resulted in reduction of the chest and abdomen in the CTDIvol (35.2%, 5.9%) and DLP (49.3%, 3.2%). Compared with manually selected fixed tube current, AEC resulted in reduced radiation dose at MDCT study of chest and abdomen.

Development of Automated Quantitative Spray Control System for High Quality Crop Cultivation (고품질 작물 재배를 위한 자동화 정량 방제 제어 시스템 개발)

  • Oh, Seung-Ho;Yang, Seong-Wook;Kim, Hyung-Chan;Kim, Do-Hyeon;Doh, Yang-Hoi
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.267-274
    • /
    • 2017
  • Recently, several researches have been studied on agricultural automation system according to convergence of IT technology with agriculture. An automatic control system of the growth environment in crops is one of the these researches. The controls of damages caused by diseases and insects pest in crops are mainly carried out by manual mode or semi-automatic mode because of farmer's concerns for poor efficiency. But, this situation needs to be improved because it occurs various problems, such as human exposure to toxic pesticides, environmental pollution and waste due to drug overuse. In order to solve these problems, we developed an automatic quantity control system which based on the amount of pesticides for area under cultivation. The amount of pesticides is calculated according to the manufacturer's instruction for pesticides. To verify the effectiveness of our developed automatic system, we also compared with the systems of manual mode and the semi-automatic mode. The experimental results of a pest control performance of an automatic quantity control system showed that automatic system can reduce overuse of drugs. These results suggested that it can be expected to replace the existing system, with equivalent effectiveness to the manual mode.

Quality Control of Radiation Dosimetry Service (개인피폭선량 측정기관의 품질관리기준 개발)

  • Lee, Jun-Haeng;Lee, Sang-Bock;Chang, Kun-Jo;Lee, Kwang-Yong;Lee, Hyun-Koo;Kim, Hyeog-Ju;Jin, Gye-Hwan
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.253-259
    • /
    • 2009
  • We have developed standards based on international criterions for the quality control of dose tested by the measurement institutions of individual exposure doses through improving the reliability of data on the exposure dose of individuals working in radioactive environment and securing the accuracy and reliability of individual dose measurements. Laws related to radiation dose applied to domestic institutions refer to ANSI N13.11.1993, but currently, in U.S. and some other countries the measurement of radiation doses is based on ANSI N13.11.2001 that reduced test categories and tightened the standards. We made efforts to simplify the standards and to reduce the number of dosimeters required in experiment, and avoided preventing or hindering the use of future technologies not approved under the current law such as glass dosimeter and optical stimulation dosimeter. The Quality Management Manual of Radiation Dosimetry Service, Assessment Manual of Radiation Dosimetry Service Accreditation Program, and the Personnel Dosimetry Performance. Criteria for Testing are documents applicable in supervising laboratories.

  • PDF

Development of Automatic Ultrasonic Testing Equipment for Pressure-Retaining Studs and Bolts in Nuclear Power Plant (원자력 발전소 STUD BOLT의 자동초음파 주사장치 개발)

  • Suh, D.M.;Park, M.H.;Hong, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.106-110
    • /
    • 1989
  • Bolting degradation problems in primary coolant pressure boundary applications have become a major concern in the nuclear industry. In the bolts concerned, the failure mechanism was either corrosion wastage(loss of bolt diameter) or stress-corrosion cracking.(3) Here the manual ultrasonic testing of RPV(Reactor Pressure Vessel) and RCP(Reactor Coolant Pump) stud has been performed. But it is difficult to detect indications because examiner can not exactly control the rotation angle and can not distinguish the indication from signals of bolt. In many cases, the critical sizes of damage depth are very small(1-2 mm order). At critical size, the crack tends to propagatecompletly through the bolt under stress, Resulting in total fracture.(3) Automatic stud scanner for studs(bolts) was developed because the precise measurement of bolt diameter is required in this circumstance. By use of this scanner, the rotation angle of probe was exactly controlled and the exposure time of radiations was reduced.

  • PDF

The effect of body lead burden on neurobehavioral function in retired lead workers (퇴직한 납 근로자들의 체내 납 부담 노출지표가 신경행동학적 기능에 미치는 영향)

  • Kim, Nam-Soo;Kim, Jin-Ho;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.3
    • /
    • pp.156-167
    • /
    • 2010
  • To evaluate the effect of lead biomarkers including bone lead on neurobehavioral test in retired lead workers, 131 retired lead workers without any occupational exposure to organic solvent, mercury and arsenic were agreed to participate this study. For the control subjects 56 non-occupationally lead exposed subjects were recruited from same area of retired lead workers with consideration of demographic characteristics. The mean levels of blood and bone lead of retired lead workers were significantly higher than control group and there were significant correlation among other lead biomarkers. Compared with controls without occupational lead exposure, lead exposured subjects had worse performance on 10 tests out of 12 neurobehavioral tests, but only two tests(Purdue pegboard nondominant and both hand) showed statistical significance of differences. In multiple linear regression analysis of neurobehavioral tests with lead biomarkers and demographic and lifestyle variables, age was associated negatively with 11 neurobehavioral tests, whereas log-transformed ZPP was associated with Purdue pegboard(both hand) and Santa Ana manual dexterity(non-dominant hand). On the other hand, tibia lead was associated Pursuit aiming test(correct) and Purdue pegboard(dominant hand) and calcaneal lead was associated with Purdue pegboard(dominant hand). This study confirmed that among all relevant variables age was most significantly associated with the poor performance of neurobehavioral tests. The blood lead did not have any significant association with neurobehavioral tests, but tibia and calcaneal bone lead and blood ZPP showed significant association with a few tests even after more than mean 9 years from their retirements.

Hormone Replacement Therapy and Risk of Breast Cancer in Korean Women: A Quantitative Systematic Review

  • Bae, Jong-Myon;Kim, Eun Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.48 no.5
    • /
    • pp.225-230
    • /
    • 2015
  • Objectives: The epidemiological characteristics of breast cancer incidence by age group in Korean women are unique. This systematic review aimed to investigate the association between hormone replacement therapy (HRT) and breast cancer risk in Korean women. Methods: We searched electronic databases such as KoreaMed, KMbase, KISS, and RISS4U as well as PubMed for publications on Korean breast cancer patients. We also conducted manual searching based on references and citations in potential papers. All of the analytically epidemiologic studies that obtained individual data on HRT exposure and breast cancer occurrence in Korean women were selected. We restricted the inclusion of case-control studies to those that included age-matched controls. Estimates of summary odds ratio (SOR) with 95% confidence intervals (CIs) were calculated using random effect models. Results: One cohort and five case-control studies were finally selected. Based on the heterogeneity that existed among the six studies (I-squared=70.2%), a random effect model was applied. The summary effect size of HRT history from the six articles indicated no statistical significance in breast cancer risk (SOR, 0.983; 95% CI, 0.620 to 1.556). Conclusions: These facts support no significant effect of HRT history in the risk of breast cancer in Korean women. It is necessary to conduct a pooled analysis.

Association of Pre- and Perinatal Risk Factors With Tourette Syndrome or Chronic Tic Disorders in a Korean School-Age Population

  • Wooseok Choi;Soon-beom Hong;Johanna Inhynag Kim;Jung Lee;Soomin Jang;Yebin D Ahn;You Bin Lim;Sumin Kim;Mee Rim Oh;Bung-Nyun Kim
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.34 no.1
    • /
    • pp.37-44
    • /
    • 2023
  • Objectives: Tic disorders are highly heritable; however, growing evidence suggests that environmental factors play a significant role in their pathogenesis. Studies on these factors have been inconsistent, with conflicting results. Therefore, this study aimed to examine the associations of pre- and perinatal exposure to Tourette syndrome (TS) or chronic tic disorders (CTD) in Korean school-aged children. Methods: This case-control study used data from a large prospective cohort study. The primary outcome was TS/CTD diagnosis according to the Diagnostic and Statistical Manual of Mental Disorders, 5th edition (DSM-5) criteria and Kiddie-Schedule for Affective Disorders and Schizophrenia-Present and Lifetime Version-Korean Version. Demographic, pre-, and perinatal information was obtained from the maternal questionnaires. Data between the TS/CTD and control groups were compared using the chi-squared or Student's t-test, as appropriate. Two-step logistic regression analyses were used to test the association between TS/CTD and pre- and perinatal risk factors. Results: We included of 223 children (78 with TS/CTD and 145 controls). Significant differences in the demographic data between the two groups were observed. The male sex ratio, mean parental age, parental final education level, and family history of tics were included as confounders. In the final adjusted multivariable model, TS/CTD was significantly associated with antiemetic exposure during pregnancy (odds ratio [OR]=16.61, 95% confidence interval [CI] 1.49-185.22, p=0.02) and medically assisted reproduction (OR=7.89, 95% CI 2.28-27.28, p=0.01). Conclusion: Antiemetic exposure and medically assisted reproduction are significantly associated with the risk of TS/CTD. These results should be replicated in future prospective and gene-by-environment studies.

Characteristics of Workers' Exposure to Aerosolized Particles during the Production of Carbon Nanotube-enabled Composites (탄소나노튜브 복합체 취급 작업자의 공기 중 입자상 물질 노출 특성)

  • Kwon, Jiwoon;Kim, Sungho;Jang, Miyeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2020
  • Objectives: The purpose of this case study is to assess workers' exposure to carbon nanotubes(CNTs) and characterize particles aerosolized during the process of producing CNT-enabled polytetrafuoroethylene(PTFE) composites at a worksite in Korea. Methods: Personal breathing zone and area samples were collected for determining respirable concentrations of elemental carbon(EC) using NIOSH(National Institute for Occupational Safety and Health) Method 5040. Personal exposure to nano-sized particles was measured as the number concentration and mean diameter using personal ultrafine particle monitors. The number concentration by particle size was measured using optical particle sizers(OPS) and scanning mobility particle sizers(SMPS). Transmission electron microscopy (TEM) area samples were collected on TEM grids and analyzed to characterize the size, morphology, and chemistry of the particles. Results: Respirable EC concentrations ranged from 0.04 to 0.24 ㎍/㎥, which were below 23% of the exposure limit recommended by NIOSH and lower than background concentrations. Number concentrations by particle size measured using OPS and SMPS were not noticeably elevated during CNT-PTFE composite work. Instant increase of number concentrations of nano-sized particles was observed during manual sanding of CNT-PTFE composites. Both number concentrations and mean diameters did not show a statistically significant difference between workers handing CNT-added and not-added materials. TEM analyses revealed the emission of free-standing CNTs and CNT-PTFE aggregate particles from the powder supply task and composite particles embedded with CNTs from the computer numerical control(CNC) machining task with more than tens of micrometers in diameter. No free-standing CNT particles were observed from the CNC machining task. Conclusions: Significant worker exposure to respirable CNTs was not found, but the aerosolization of CNTs and CNT-embedded composite particles were observed during handing of CNT-PTFE powders and CNC machining of CNT-PTFE composites. Considering the limited knowledge on the toxicity of CNTs and CNT composite particles to date, it seems prudent to take a precautionary approach for the protection of workers' health.

Studies on the Establishment of Tolerance Level of Radioactive Compounds in Livestock Feeds (가축 사료 중 방사성 물질 허용 기준 설정에 관한 연구)

  • Lee, Wanno;Ji, Sang-Yun;Kim, Jin Kyu;Lee, Yun-Jong;Park, Jun Cheol;Moon, Hong Kil;Lee, Ju-Woon
    • Journal of Radiation Industry
    • /
    • v.5 no.4
    • /
    • pp.337-345
    • /
    • 2011
  • In order to provide an effective preparedness for a nuclear or radiological emergency happening in the domestic or neighborhood countries and to solve the vague fear of the people for the ingestion of radioactive livestock products, the establishment of national guideline level for radionuclides in feed is urgently necessary. This is because it is important to secure the safety and to manage the crisis in the agricultural, fishery and food sector by performing the effective safety control during and after nuclear incident. This study was performed to investigate the report cases of international organizations and foreign countries to set up a domestic control standard for managing radioactive substances that may be contaminated in animal feeds due to the nuclear power plant incident. In addition, an attempt was made to provide a useful reference that can help prepare a domestic control standard, using a coefficient that can consider the transfer into livestock through the intake of radioactive contaminated animal feeds. The standard radioisotopes investigated were confined to radioactive cesium ($^{137+134}Cs$) and iodine ($^{131}I$). Guideline level for the radionuclides was calculated by using the transfer coefficient factor and the maximum daily intake of animal feed provided by IAEA. For example, the maximum daily intake of animal feed was set as $25kg\;d^{-1}$ for dairy cows, $10kg\;d^{-1}$ for beef cattle, $3.0kg\;d^{-1}$ for pigs and $0.15kg\;d^{-1}$ for chickens. The result values for radioactive cesium were calculated as $8,696Bq\;kg^{-1}$, $4,545Bq\;kg^{-1}$, $1,667Bq\;kg^{-1}$ and $2,469Bq\;kg^{-1}$, respectively. The results for radioactive iodine showed the ranges between $741Bq\;kg^{-1}$ and $76,628Bq\;kg^{-1}$. These data can be utilized as a scientific reference for the preparation of a crisis management manual for the emergency control due to nuclear power plant accident in Korea and neighboring country. These results will contribute to establish the safe feed management system at national level as manual for responding the radioactive exposure of agricultural products and animal feeds, which are currently not established.

Implementation of color CCD Camera using DSP(GCB4101) (디지털 신호처리 칩(GCD4101)을 사용한 컬러 CCD 카메라 구현)

  • Kwon, O-Sang;Lee, Eung-Hyuk;Min, Hong-Ki;Chung, Jung-Seok;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.69-79
    • /
    • 1999
  • The research and implementation was preformed on high-resolution CCTV camera with CCD exclusive DSP conventional analog signal processor CCTV camera has its limit on auto exposure(AE), auto white balance(AWB), back light compensation(BLC) processing, severe distortion and noise of image, manual control parameter setting, etc. In our study, to resolve the problems in conventional CCTV camera, we made it possible to control AE, AWB, BLC automatically by the use of the DSP, which are used exclusively in the CCD camera produced domestically, and the microcontroller. And we utilized the function of screen display of microcontroller for the user-friendly interface to control CCD camera. And the electronic variable resister(EVR) was used to avoid setting parameters manually in the level of manufacturing process. As the result, It became possible to control parameters of the camera by program. And the cost-down effect was accomplished by improving the reliability of parameter values and reducing the efforts in setting parameters.

  • PDF