• Title/Summary/Keyword: Mann-Whitney test.

Search Result 1,213, Processing Time 0.034 seconds

CEA, AFP, CA125, CA153 and CA199 in Malignant Pleural Effusions Predict the Cause

  • Wang, Xin-Feng;Wu, Yan-Hua;Wang, Mao-Shui;Wang, Yun-Shan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.1
    • /
    • pp.363-368
    • /
    • 2014
  • Determination of the cause of malignant pleural effusions is important for treatment and management, especially in cases of unknown primaries. There are limited biomarkers available for prediction of the cause of malignant pleural effusion in clinical practice. Hence, we evaluated pleural levels of five tumor biomarkers (CEA, AFP, CA125, CA153 and CA199) in predicting the cause of malignant pleural effusion in a retrospective study. Kruskal-Wallis or Mann-Whitney U tests were carried out to compare levels of tumor markers in pleural effusion among different forms of neoplasia - lung squamous cell carcinoma, adenocarcinoma, or small cell carcinoma, mesothelioma, breast cancer, lymphoma/leukemia and miscellaneous. Receiver operator characteristic analysis was performed to evaluate sensitivity and specificity of biomarkers. The Kruskal-Wallis test showed significant differences in levels of pleural effusion CEA (P<0.01), AFP (P<0.01), CA153 (P<0.01) and CA199 (P<0.01), but not CA125 (P>0.05), among the seven groups. Receiver operator characteristic analysis showed that, compared with other four tumor markers, CA153 was the best biomarker in diagnosing malignant pleural effusions of lung adenocarcinoma (area under curve (AUC): 0.838 (95%confidence interval: 0.787, 0.888); cut-off value: 10.2U/ml; sensitivity: 73.2% (64.4-80.8)%, specificity: 85.2% (77.8-90.8)%), lung squamous cell carcinoma (AUC: 0.716 (0.652, 0.780); cut-off value: 14.2U/ml; sensitivity: 57.6% (50.7-64.3)%, specificity: 91.2% (76.3-98.0)%), and small-cell lung cancer (AUC: 0.812 (0.740, 0.884); cut-off value: 9.7U/ml; sensitivity: 61.5% (55.0-67.8)%, specificity: 94.1% (71.2-99.0)%); CEA was the best biomarker in diagnosing MPEs of mesothelioma (AUC: 0.726 (0.593, 0.858); cut-off value: 1.43ng/ml; sensitivity: 83.7% (78.3-88.2)%, specificity: 61.1% (35.8-82.6)%) and lymphoma/leukemia (AUC: 0.923 (0.872, 0.974); cut-off value: 1.71ng/ml; sensitivity: 82.8% (77.4-87.3)%, specificity: 92.3% (63.9-98.7)%). Thus CA153 and CEA appear to be good biomarkers in diagnosing different causes of malignant pleural effusion. Our findings implied that the two tumor markers may improve the diagnosis and treatment for effusions of unknown primaries.

MICROLEAKAGE OF 2-STEP ADHESIVE SYSTEMS IN DIAMOND-PREPARED CAVITY (다이아몬드 기구로 삭제한 와동에서 2단계 접착제의 미세누출 비교)

  • Lee, Myung-Goo;Cho, Kwon-Hwan;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.437-444
    • /
    • 2007
  • The purpose of this study was to compare the marginal microleakage of different 2-step adhesive systems in Class V cavities prepared with different diamond points. Forty Class V cavities were prepared with two different (coarse or fine) diamond points on cervical third of extracted molars. The occlusal and gingival margin of cavities was located in enamel and dentin, respectively. They were divided into one of four equal groups (n = 10) and ; Group 1-prepared with coarse diamond point (EX-41), restored with Single Bond and Z 250, Group 2-prepared with fine diamond piont (TF-21F), restored with Sing)e Bond and Z 250, Group 3-prepared with coarse diamond point (EX-41), restored with Clearfil SE Bond and Clearfil AP-X, Group 4-prepared with fine diamond point (TF-21F), restored with Clearfil SE Bond and Clearfil AP-X. Specimens were thermocycled, immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed leakages at enamel and dentinal margins. Data were analyzed using Mann-Whitney and Wilcoxon signed ranked test. In this study, marginal microleakage or Single Bond was not affected by type of diamond points. But Clearfil SE Bond showed higher marginal microleakage at both enamel and dentinal margin when Class V cavity was prepared with coarse diamond point.

Assessment of Predicting Factors for Pediatric Sleep Disordered Breathing (소아 수면호흡장애의 예측 인자 평가)

  • Moon, Soyeon;Lee, Daewoo;Kim, Jaegon;Yang, Yeonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.4
    • /
    • pp.377-388
    • /
    • 2020
  • The aim of this study was to evaluate the association between various predicting tools and Apnea-Hypopnea Index (AHI) to identify children with sleep disordered breathing (SDB). From 5 to 10 years old who came for orthodontic counseling, 61 children, whom had lateral cephalograms, pediatric sleep questionnaire (PSQ) records, and portable sleep monitoring results, were included in this study. A total of 17 measurements (11 distances and 6 angles) were made on lateral cephalograms. The measurements of lateral cephalograms, PSQ scales and portable sleep monitoring results were statistically analyzed. 49 of 61 (80%) patients showed AHI > 1, which suspected to have SDB and their mean AHI was 2.75. In this study, adenoid size (A/N ratio), position of the hyoid bone from mandibular plane, gonial angle, and PSQ scale were related to a higher risk of pediatric SDB. Also, oxygen desaturation index (ODI) and snoring time from sleep monitoring results were statistically significant in children with SDB using Mann-Whitney test (p < 0.05). In conclusion, evaluation of hyoid bone position, adenoidal hypertrophy, gonial angle in lateral cephalogram, and PSQ scale was important to screen out potential SDB, especially in children with frequent snoring.

Evaluation of Validity of Edentulous Digital Model for Complete Denture Fabrication (총의치 제작을 위한 무치악 디지털 모형의 정확도 평가)

  • Kim, Won-Soo;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.15 no.4
    • /
    • pp.393-398
    • /
    • 2015
  • One of the most critical causes in determining the clinical outcomes of dental prostheses is the validity of models. However, studies that evaluated validity of digital models are few. The objectives of this study were to evaluate validity of edentulous digital models for full denture fabrication. Twenty stone models (edentulous model) were manufactured and scanned by dental blue light emitting diode scanner. Twenty digital models were manufactured. Six linear distances (inter-canine distance, inter-molar distance, two dental arch lengths (right, left), two diagonal of dental arch lengths (right, left) were measured for validity evaluation. The measurements of distances of stone models were used by digital vernier caliper and digital models were used by computer program. The mean${\pm}$deviations values of six distances were calculated. The means were compared by the Mann Whitney U test (${\alpha}=0.05$). All statistical analysis were performed using IBM SPSS Statistics ver. 20.0. Although digital models were smaller than stone models in six distances, there were no significant differences (p>0.05) and non exceeded the clinical acceptable range. The edentulous digital models for full denture fabrication can be considered clinically acceptable.

Effectiveness of 70% Alcohol Solution and Hand Washing Methods on Removing Transient Skin Bacteria in Foodservice Operation (급식시설의 손 세척을 위한 70% 알콜 소독제 사용 및 세척방법의 적용효과 분석)

  • Gwak, Dong-Gyeong;Jang, Hye-Ja;Ryu, Gyeong;Kim, Seong-Hui
    • Journal of the Korean Dietetic Association
    • /
    • v.4 no.2
    • /
    • pp.235-244
    • /
    • 1998
  • Hand washing is an important component of hygiene program for food handlers. Hands can be a source of direct or indirect contamination of foods with pathogenic microorganisms. In this study, the effectiveness of hand washing methods and the use of 70% alcohol solution against transient skin bacteria was tested in an university foodservice facility. 70% alcohol solution is sprayed for 5 seconds automatically when hands are placed in the dispenser. Samples were taken using swab technique in meat cutting area, vegetable trimming area, and vegetable cutting area: before and after washing hands according to planned methods, and after being sprayed with 70% alcohol solution after washing hands. The bacteriological analysis of total plate counts, coliform, fecal coliform of food handlers' hands was done. Statistical data analysis was completed with Mann-Whitney U test and Kruskal-Wallis model using the SPSS program. The levels of initial contamination of workers' hand were significantly different by the work areas($x^2$=9.156, p<0.01). Workers in the vegetable trimming area had more heavily soiled hands than in the other work areas. Mean of TPC counts and coliform was 8.97×$10^5$ CFU/12.4$cm^2$, 2.93×$10^2$ MPN/12.4$cm^2$ respectively, but fecal coliform was not detected. Transient bacteria were removed from hands after washing and using 70% alcohol solution but were not removed completely. Mean reduction percentage in TPC varied among work areas and ranged from 93.19% to 94.99%, and in coliforms from 97.31% to 100%. A significant difference in TPC was found between before and after hand disinfection (Z=-2.714, p<.01) and between standardized hand washing procedures and un-standardized hand washing procedures(z=-2.301, p<.01). Subjects using the hand sanitizer showed a great elimination of TPC(99.45% reduction), but this effect was valid only after following proper washing procedures. Based on the results, the most effective hand washing method was recommended as the combination of the standardized hand washing procedure with warm-water and use of the 70% alcohol solution. The results can be used to develop hand hygiene programs and training strategies for enhancing hand hygiene practices for food handlers in foodservice operations.

  • PDF

Long Term Average Spectrum Characteristics of Head and Chest Register Sounds of Western Operatic Singers : Extended Study (성악다들의 목소리에 대한 Long Term Average Spectrum 분석 -$2^{nd}$ Singer's Formant의 존재 가능성에 대하여-)

  • Ban, Jae-Ho;Kwon, Young-Kyung;Jin, Sung-Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.1
    • /
    • pp.31-36
    • /
    • 2004
  • Background and Objectives : It has been shown that the epilaryngeal tube in the human airway is responsible for vocal ring, or the singer's formant. In previous study, authors showed that in trained tenors, besides the conventional singer's formant in the region of ,5500Hz, another energy peak was observed in the region of 8,000Hz. This peak was interpreted as the second resonance of the epilarynx tube. Singers in other voice categories who produce vocal ring are assumed to have the same peak, but no measurements have as yet been made. Materials and Methods : Fifteen tenors, fourteen baritones, seven sopranos and five mezzo sopranos attending the music college, department of vocal music who could reliably produce the head and chest registers were chosen for this study. Each subject was asked to produce an/ah/sound for at least three seconds for the head register sound(tenors ; G4, barions ; E4 sopranos ; F5 and mezzosopranos ; C5) and for the chest register sound (tenors ; C3, baritones ; D3, sopranos ; D4 and Mezzosoprano ; A3). The sound data was analyzed using the Fast Fourier Transform (FFT)-based power spectrum, Long term average(LTA) power spectrum using the FFT algorithm of the Computerized Speech Lab (CSL, Kay elemetrics, Model 4300B, USA). Statistical analysis was performed using the Mann-Whitney test of the Statistical Package for Social sciences(SPSS). Results : For head register sounds, a significant increase was seen in the 2,200-3,400Hz region(p<0.05) and the Similar to the head register sounds, there was a significant increase in energy in the four trained singer group compared with the untrained group in the 2,200-3,100Hz region(p<0.05), the 7,800-8,400Hz region(p<0.05) for the chest register sounds. Conclusions : When good vocal production was made for the head and chest registers, an energy peak was observed near 2,500Hz, a frequency already known as the "singer's formant', in all subjects in the study group. Another region of increased energy was observed around 8,000Hz that had not been noticed previously. The authors believe this region to be the second singer's formant.

  • PDF

Cephalometric Predisposing Factors of the Snoring and Obstructive Sleep Apnea (코골이 및 폐쇄성 수면 무호흡증의 두부 규격 방사선 계측학적 기여 인자)

  • Seo, Eun-Woo;Lee, Ho-Kyung;Han, Min-Woo;Seo, Mi-Hyun;Kim, Hyun-Jun;Song, Seung-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.3
    • /
    • pp.161-166
    • /
    • 2013
  • Purpose: This study was intended to perform a cephalometric comparison between the patients with and without obstructive sleep apnea (OSA). The factors influencing the OSA in the lateral cephalogram were also investigated. Methods: Fifty patients who had visited the Sleep Disorder Clinic at the Ajou University Hospital and evaluated with the polysomnograph (PSG) and cephalogram, were included in the study. The patients had the apnea-hypopnea episode over 5 times per hour (apnea-hypopnea index $[AHI]{\geq}5$) were diagnosed as OSA after the overnight PSG. To evaluate the hard and soft tissue profiles, the cephalometric radiograms were taken at the maximal intercuspation. The correlation between the patient's age, height, weight, body mass index (BMI) and AHI was inspected in the OSA and control group. The difference between the OSA and control group was evaluated (Mann-Whitney U Test). The cephalometric influencing factors to OSA were analyzed (Pearson's correlation coefficient) statistically using SPSS statistics. Results: The OSA Group had a significantly higher BMI than the control group. The mean lower facial height (ANS-Me) was longer in the OSA group; however, statistically significant difference was not detected in the anteroposterior craniofacial measurements. The distance between mandibular plane and hyoid bone of the OSA group was significantly longer than that of the control group. The hyoid position (MP-Hyoid) had a positive correlation between AHI (P<0.001). However, the measurements of oropharyngeal airway were not different between the two groups. The hypothesis, that the antero-posteriorly narrow oropharyngeal airway may aggravate the airway resistance and give rise to a higher AHI, was rejected in the study. Conclusion: We suggest that the lateral cephalogram may be utilized as a useful method to evaluate OSA. The patients with a lower hyoid position can be expected to have higher risks of OSA. However, a comprehensive intraoral inspection, including the soft palate and tonsilar hypertrophy, is emphasized, as the lateral cepahlogram cannot visualize the oropharyngeal status completely.

THE EFFECTS OF ATELO-COLLAGEN SPONGE INSERTION ON THE PERIODONTAL HEALING OF SECOND MOLARS AFTER IMPACTED MANDIBULAR THIRD MOLAR EXTRACTION (매복 하악 제3대구치 발치와에 Atelo-collagen Sponge 삽입이 제2대구치 예후에 미치는 영향)

  • Nam, Jin-Woo;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.2
    • /
    • pp.112-119
    • /
    • 2009
  • Extracellular matrix(ECM) is known to function as a reservoir of endogenous growth factors, can be an effective delivery system of growth factor that easily lost bioactivity in solution. Fibrillar collagens like type I collagen, are the major constituent of the ECM and structural protein of bone. Also, it can be a scaffold for osteoblast migration. The purpose of this study was to compare the effects of absorbable Atelo-collagen Sponge($Teruplug^{(R)}$) insertion in tooth extraction sites on periodontal healing of the mandibular second molar after the extraction of the impacted third molar. The study population comprised 31 cases who had been scheduled for surgical removal of impacted mandibular third molars. All patients were in good general health and were not using any medication that would influence wound healing after surgery. In 15 cases control group, none was inserted into the tooth extraction site. In 16 cases experimental groups, $Teruplug^{(R)}$ was inserted into the tooth extraction site. We evaluated tooth mobility, pocket depth, gingival margin level preoperatively and 1 week, 2 weeks, 4 weeks, and 3 months postoperatively. The change was compared with two groups using Mann-Whitney test. The results were as follows. 1. There was no significant change of tooth mobility on both groups. 2. There was tendency of decreasing of previous pocket depth causing tooth extraction on both groups. 3. On gingival margin level, there was various change according to initial swelling and loss of attachment on both groups. 4. There was tendency of decreasing of gingival margin level on both groups because of removal of inflammation and decreasing of previous pocket depth. 5. There was large change of pocket depth on buccal middle, distal, lingual distal area because of tooth extraction and bone reduction. Compared with the control group and experimental group, we observed significant difference during some periods. The results of this study suggest that absorbable atelo-collagen sponge($Teruplug^{(R)}$) is relatively favorable bone void filler with prevention of tissue collapse, food packing and enhance periodontal healing.

MARGINAL MICROLEAKAGE OF SELF-ETCHING PRIMER ADHESIVES AND A SELF-ETCHING ADHESIVE (자가 산부식 프라이머와 자가 산부식 접착제의 변연 미세누출)

  • Cho, Young-Gon;Cho, Kong-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.493-501
    • /
    • 2002
  • This study evaluated the microleakage performance of four self-etcing primer adhesives(Clearfil SE Bond, Clearfil Liner Bond 2, UniFil Bond, and FL Bond) and one self-etching adhesive(Prompt L-Pop). Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of 50 extracted human molar teeth. Prepared teeth were randomly divided into five groups and restored using one of five adhesives and composite resins: Prompt L-Pop/Filtek Z 250(Group 1), Clearfil SE Bond/Clearfil AP-X(Group 2), Clearfil Liner Bond 2/Clearfil AP-X(Group 3), UniFil Bond/UniFil F(Group 4), and FL Bond/Filtek Z 250(Group 5). Following one day storage in room temperature water, the restored teeth were thermocycled for 500 cycles between 5$^{\circ}C$ and 55$^{\circ}C$. Marginal microleakage was assessed by dye penetration using 2% methylene blue dye. After 24 hours, the teeth were sectioned longitudinally and evaluated for microleakage under steromicroscope The data were statistically analysed by Kruskal-Wallis Test, Mann-Whitney and Wilcoxon signed ranked tests. The results of this study were as follows ; 1. The microleakges at both enamel and dentinal mal$.$gins were the lowest in group 4. increasing among groups in the following order: group 2, follwed by group 5, follwed by group 1, and the highest in group 3. 2. At the enamel margins, the microleakage of group 3 was significantly higher than those of groups 2. 4 and 5(p<0.05), and also the microleakage of group 1 was statistically higher than those of groups 2 and 5(p<0.05). 3. At the dentinal margins, microleakage of group 3 was signincantly higher than microleakages of groups 1, 2, 4 and 5(p<0.05). 4. Compared with microleakages between the enamel and dentinal margins of each group, groups 1, 4 and 5 at enamel margin and group 2 and group 3 at dentinal margin were higher microleakage. But there was no significant difference between enamel and dentinal microleakages of each group(p>0.05).

Development and evaluation of standards for clinical dental hygiene practice (국내 표준 임상치위생실무지침의 개발 및 타당성 평가)

  • Lee, Hyo-Jin;Bae, Soo-Myoung;Choi, Yong-Keum;Kwak, Seon-Hui;Kim, Hyun-Sook;Kim, Hye-Jin;Lim, Keun-Ok;Lim, Hee-Jung;Jang, Sun-Ok;Han, Yang-Keum;Shin, Bo-Mi
    • Journal of Korean society of Dental Hygiene
    • /
    • v.20 no.5
    • /
    • pp.717-731
    • /
    • 2020
  • Objectives: The purpose of this study was to develop applicable standards for clinical dental hygiene practice in Korea and to evaluate their validity. Methods: Based on the standards for clinical dental hygiene practice developed in the United States and Canada, the standards were adapted to be applicable in Korea. The validity of the standards was evaluated by a self-writing questionnaire among 14 professors and 10 clinicians using a developed tool for evaluating the standards. A focus group interview was additionally conducted for clinicians to increase the validity of the standards. Descriptive statistics and Mann-Whitney test were performed using SPSS 25.0. To analyze the content of the focus group interviews, content analysis was conducted. Results: The standards for clinical dental hygiene practice consisted of five elements of professionalism for dental hygienists and a total of 28 items to perform the five stages of dental hygiene process of care (assessment, diagnosis, planning, implementation, and evaluation) and included conceptual meaning, clinical significance, and application methods with examples for each item. Conclusions: The standards for clinical dental hygiene practice developed in this study could contribute to standardizing dental clinical practices provided by dental hygienists. It is necessary to consistently improve the standards that are highly practical, to prevent oral diseases and maintain oral health of the public, based on the results of this validity evaluation.