• Title/Summary/Keyword: Mandibular second premolar

Search Result 154, Processing Time 0.025 seconds

Prevalence and Patterns of Congenitally Missing Teeth among Pediatric Patients Aged 8 - 16 in Pusan National University Dental Hospital (부산대학교 치과병원에 내원한 8 - 16세 환자의 선천성 치아 결손 유병률 및 유형 평가)

  • Eunjin Kim;Soyoung Park;Eungyung Lee;Taesung Jeong;Jonghyun Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.2
    • /
    • pp.179-191
    • /
    • 2023
  • The purpose of this study was to investigate the prevalence and patterns of congenitally missing teeth in permanent teeth excluding third molars, in patients aged 8 to 16 years who visited Pusan National University Dental Hospital from January 2010 to February 2021. This retrospective study evaluated tooth agenesis and the pattern of missing teeth represented by the tooth agenesis code by reviewing panoramic radiographs and electronic medical records of 11,759 patients, including 5,548 females and 6,211 males. The prevalence of congenitally missing teeth was 10.74% (females 11.95%, males 9.66%, p < 0.0001). Patients with tooth agenesis had an average of 2.22 missing teeth, and congenitally missing teeth occurred more frequently in the mandible (8.39%) than in the maxilla (4.52%, p < 0.0001). The mandibular second premolar (58.19%) was the most frequently missing tooth. The second premolar was the most frequently missing tooth in all quadrants (30.10%, 31.67%, 43.14%, and 35.59%) when a single tooth was absent, while the first and second premolars were the most commonly absent teeth (11.69%, 11.47%, 5.94%, and 5.24%) when two or more teeth were missing. In the relationship between maxillary-mandibular antagonistic quadrants and full mouth, the 1st to 4th place of the missing patterns were all involved with the 1st and 2nd premolars. This study can be clinically helpful in establishing a treatment plan for patients with missing teeth. In addition, it can be used as basic data for molecular biological research to find out the relationship between tooth agenesis and specific genes.

Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system (가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형 상에서 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내면 적합도 비교)

  • Wan-Sun Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.72-81
    • /
    • 2024
  • Purpose: This study aimed to assess the marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures (FPDs) fabricated via computer-aided design and computer-aided manufacturing (CAD/CAM) from solid working casts and removable die system. Materials and Methods: The tooth preparation protocol for a zirconia crown was executed on the mandibular right first premolar and mandibular right first molar, with the creation of a reference cast featuring an absent mandibular right second premolar. The reference cast was duplicated using polyvinyl siloxane impression, from which 20 working casts were fabricated following typical dental laboratory procedures. For comparative analysis, 10 FPDs were produced from a removable die system (RD group) and the remaining 10 FPDs from the solid working casts (S group). The casts were digitized using a dental desktop scanner to establish virtual casts and design the FPDs using CAD. The definitive 3-unit monolithic zirconia FPDs were fabricated via a CAM milling process. The seated FPDs on the reference cast underwent digital evaluation for marginal and internal fit. The Mann-Whitney U test was applied for statistical comparison between the two groups (α = 0.05). Results: The RD group showed significantly higher discrepancies in fit for both premolars and molars compared to the S group (P < 0.05), particularly in terms of marginal and occlusal gaps. Color mapping also highlighted more significant deviations in the RD group, especially in the marginal and occlusal regions. Conclusion: The study found that the discrepancies in marginal and occlusal fits of 3-unit monolithic zirconia FPDs were primarily associated with those fabricated using the removable die system. This indicates the significant impact of the fabrication method on the accuracy of FPDs.

Cone-beam computed tomography analysis of root and canal morphology of mandibular premolars in a Spanish population

  • Llena, Carmen;Fernandez, Jaime;Ortolani, Pablo Sebastian;Forner, Leopoldo
    • Imaging Science in Dentistry
    • /
    • v.44 no.3
    • /
    • pp.221-227
    • /
    • 2014
  • Purpose: This study aimed to investigate the clinical anatomy of lower premolar roots in a Spanish population by using cone-beam computed tomography (CBCT), correlating findings with patient gender and tooth type. Materials and Methods: Using 70 CBCT images, we evaluated 126 healthy, untreated, well-developed lower premolars. The number and morphology of roots and root canals, and the foramina number were assessed. Results for gender and tooth type were compared using the chi-squared and ANOVA tests. Results: The average length of teeth and roots was significantly higher in men (p=0.00). All 126 premolars had a single root. One canal was found in 83.3% of the premolars, with no gender or tooth type differences; Vertucci configuration types I and V were the most prevalent. The first premolars showed significantly greater variability than the second premolars (p=0.03). A single apical foramen was found in 89.7% of the premolars, with no differences by tooth type. Women had a significantly higher prevalence of two apical foramina than men (p=0.04). Some degree of curvature was observed in 65% of the premolars, with no differences by gender or tooth type. A root angle of more than $20^{\circ}$ was found in 12.98% of the premolars, without any differences by gender or tooth. Conclusion: All premolars were single-rooted. One canal had the most prevalent morphology. More variability in canal anatomy was found in the first premolars. Curvatures greater than $20^{\circ}$ were found at less than 5 mm from the apex.

INFLUENCE OF A FUNCTIONAL LOADING TIME ON BONE FORMATION AROUND OSSEOINTEGRATED TITANIUM IMPLANTS IN ADULT DOGS (성견에서 골유착성 타이타늄 임프란트의 기능적 노출 시기가 주위의 골형성에 미치는 영향)

  • Yang Ja-Ho;Lee Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.55-74
    • /
    • 1991
  • The purpose of this study was to investigate the influence of early functional load around osseointegrated titanium implants. 24 titanium plasma spray coated implants (ITI HS-type) were placed into the previously extracted site in the mandible of six adult dogs. The implants were divided into three groups : the control group was the implants without abutment during the experimental period; the experimental group I was loaded by connecting the contoured abutment after 6 weeks of healing; the experimental group II was loaded after 12 weeks of healing: and the mandibular second premolar and surrounding tissues were selected for natural tooth group to compare the implanted group. All dogs were injected intravenously tetracycline, alizarin red S, and calcein for bone labeling. After the experimental period of 18 weeks, the dogs were sacrificed and longitudinal sections of the bone-implant interface were cut and observed using light microscope, scanning electron microscope, and fluorescence microscope. The results of the study were as follows: 1. Light and scanning electron microscopically, all implant surfaces were well contact with bone tissue at the cortical layer, but some areas of cancellous bone were not contact directly. 2. Fluorescence microscopically, number and size of the new secondary osteons around the implant were increased than those of the natural tooth. 3. Fluorescence microscopically, linear and concentrical fluorescence was observed at or near the surface of all implants, and the bone formation and remodeling of the implants loaded after 6 week of healing were great, and unloaded implants were worst. 4. Fluorescence microscopically, endosteal bone formation was greater than periosteal bone formation at or near the implants. 5. Fluorescence microscopically, number and size of linear and concentric fluorescence was increased at the lingual side than the buccal side of the loaded implants. The result of the study indicate the possibility of the early load to the implant via a prosthesis.

  • PDF

Qualitative and quantitative evaluation of root injury risk potentially burdening insertion of miniscrew implants

  • Antoszewska, Joanna;Trzesniewska, Paulina;Kawala, Beata;Ludwig, Bjorn;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.112-120
    • /
    • 2011
  • Objective: Microscrew implants (MSls) offer many advantages, but some complications are known to occur during their insertion. One of the most commonly reported complications is root injury. Our aim was to identify factors associated with root injury and to evaluate their qualitative and quantitative values. Methods: Thirty-five orthodontists placed MSls (AbsoAnchor$AbsoAnchor^{(R)}$, Dentos Co. Ltd, Daegu, Korea) in the upper jaw of typodonts, labially between the second premolar and the first molar, in low and high vertical positions. Root contacts were counted, and distances between MSI apices and roots were measured. Fear level of the orthodontists was surveyed before and after the experiment. Wilcoxon's test, chi-square test, and Mann-Whitney test were used for statistical analysis. Results: Overall root contact rate of MSI insertion was 23.57%. The root contact rate was significantly higher in MSls inserted at $90^{\circ}$ (45.71%) than at $30^{\circ}$ (1.43%). The distance between the dental root and MSI also increased significantly in MSls inserted at $30^{\circ}$. Mean fear level before MSI insertion (4.6) significantly decreased after insertion (3.2); the causative factors were risk of injury to dental root and maxillary sinus or mandibular canal. Conclusions: Root injury is relatively rare, and oblique angulation reduces the risk of root and MSI contact.

A CEPHALOMETRIC STUDY ON MESIODISTAL AXIAL INCLINATION OF POSTERIOR TEETH IN OPEN BITE AND DEEP BITE (개방교합과 과개교합에서 구치의 근원심 치축경사도에 관한 두부방사선계측학적 연구)

  • Jeon, Sang-Beom;Kim, Jin-Beom;Shon, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.23 no.3 s.42
    • /
    • pp.391-403
    • /
    • 1993
  • For the purpose of investigating mesiodistal axial inclination of posterior teeth in normal occlusion group, open bite and deep bite group and investigating the correlationship between the axial inclination of posterior teeth and overbite of anterior teeth, a cephalometric study was performed on the subjects consisted of normal occlusion group(40), open bite group(71 : Angle's Class I, Class II, division 1 25, Class III 25) and deep bite group(64 : Angle's Class I 23, Class II, division 1 21, Class III 20). Mesiodistal axial inclination of posterior teeth to occlusal, mandibular and palatal plane were measured. The findings of this study were as follows : 1. Upper and lower posterior teeth were more mesially inclined to occlusal plane in open bite group than in deep bite group. 2. Lower posterior teeth were more mesially inclined in deep bite group than in open bite group in Angle's Class II, division 1 malocclusion but there were no significant differences in Angle's Class I and Class III malocclusion. 3. There was no significant correlationship between the axial inclination of posterior teeth to each plane and overbite of anterior teeth in open bite group. 4. There was a significant correlationship between the axial inclination of upeer and lower second premolar to occlusal plane and overbite of anterior teeth in Angle's Class I, Class II, division 1 and Class III malocclusion.

  • PDF

Conservative approach of a symptomatic carious immature permanent tooth using a tricalcium silicate cement (Biodentine): a case report

  • Villat, Cyril;Grosgogeat, Brigitte;Seux, Dominique;Farge, Pierre
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.4
    • /
    • pp.258-262
    • /
    • 2013
  • The restorative management of deep carious lesions and the preservation of pulp vitality of immature teeth present real challenges for dental practitioners. New tricalcium silicate cements are of interest in the treatment of such cases. This case describes the immediate management and the follow-up of an extensive carious lesion on an immature second right mandibular premolar. Following anesthesia and rubber dam isolation, the carious lesion was removed and a partial pulpotomy was performed. After obtaining hemostasis, the exposed pulp was covered with a tricalcium silicate cement (Biodentine, Septodont) and a glass ionomer cement (Fuji IX extra, GC Corp.) restoration was placed over the tricalcium silicate cement. A review appointment was arranged after seven days, where the tooth was asymptomatic with the patient reporting no pain during the intervening period. At both 3 and 6 mon follow up, it was noted that the tooth was vital, with normal responses to thermal tests. Radiographic examination of the tooth indicated dentin-bridge formation in the pulp chamber and the continuous root formation. This case report demonstrates a fast tissue response both at the pulpal and root dentin level. The use of tricalcium silicate cement should be considered as a conservative intervention in the treatment of symptomatic immature teeth.

A CASE OF ODONTOGENIC MYXOMA RELATED TO BOTH IMPACTED CANINE TEETH IN THE MANDIBLE (소아에서 하악 양측 매복 견치와 연관된 치성 점액종)

  • Choi, Se-Hoon;Jeong, Jong-Cheol;Song, Min-Soek;Seo, Ji-Hoon;Kim, Soeng-Boem;Jun, Chang-Hun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.64-67
    • /
    • 2003
  • Odontogenic myxoma is a rare tumor which occurs almost exclusively in the jaws, and seems to be of odontogenic origin. Clinically this tumor tends to appear in the second and third decades of life, and most of the lesions are located in the premolar - molar region. It is characterized grossly by mucoid or gelatinous gray-whitish tissue that replaces the cancellous bone and expands the cortex. It is invasive locally and has a high recurrence rate ranging from 10% to 33%. Radiographically, the appearance of this tumor is varied, but usually appears as a unilocular or multilocualr radioluscency of varying size. We experienced a rare case of odontogenic myxoma 12 years old patient related to mandibular bilateral impacted canines in the mandible, so we report this case with literature.

Five-year retrospective radiographic follow-up study of dental implants with sandblasting with large grit, and acid etching-treated surfaces

  • Kim, Hak-Kyun;Lee, Eun-Young;Kim, Jae-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.6
    • /
    • pp.317-321
    • /
    • 2015
  • Objectives: The purpose of this study is to evaluate five-year radiographic follow-up results of the Korean sandblasting with large grit, and acid etching (SLA)-treated implant system. Materials and Methods: The subjects of the study are 54 patients who have been followed-up to date, of the patients who underwent implant surgery from May 1, 2009 to April 30, 2011. In all, 176 implant placements were performed. Radiographs were taken before the first surgery, immediately after the first and second surgeries, immediately and six months after the final prosthesis installation, and every year after that. Bone loss was evaluated by the method suggested by Romanos and Nentwig. Results: A total of 176 implant placements were performed - 122 in men and 54 in women. These patients have been followed-up for an average of 4.9 years. In terms of prosthetic appliances, there were 156 bridges and 20 single prostheses. Nine implants installed in the maxillary molar area, three in the mandibular molar area and two in the maxillary premolar area were included in group M, with bone loss less than 2 mm at the crestal aspect of the implant. Of these, eight implants were single prostheses. In all, six implants failed - four in the mandible and two in the maxilla. All of these failures occurred in single-implant cases. The implant survival rate was 98.1% on the maxilla and 94.3% on the mandible, with an overall survival of 96.6%. Conclusion: Within the limitations of this study, implants with the SLA surface have a very superior survival rate in relatively poor bone environments such as the maxilla.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF INTERNALLY CONNECTED IMPLANT SYSTEMS (내부연결방식 임플랜트 시스템의 삼차원 유한요소법적 연구)

  • Kim Yu-Lee;Cho Hye-Won;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.85-102
    • /
    • 2006
  • Statement of problem: Currently, there are some 20 different geometric variations in implant/abutment interface available. The geometry is important because it is one of the primary determinants of joint strength, joint stability, locational and rotational stability. Purpose: As the effects of the various implant-abutment connections and the prosthesis height variation on stress distribution are not yet examined this study is to focus on the different types of implant-abutment connection and the prosthesis height using three dimensional finite element analysis. Material and method. The models were constructed with ITI, 3i TG, Bicon, Frialit-2 fixtures and solid abutment, TG post, Bicon post, EstheticBase abutment respectively. And the super structures were constructed as mandibular second premolar shapes with 8.5 mm, 11 mm, 13.5 mm of crown height. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the central pit of an occlusal surface. von Mises stresses were recorded and compared in the crowns, abutments, fixtures. Results: 1. Under the oblique loading, von Mises stresses were larger in the crown, abutment, fixture compared to the vertical loading condition. 2. The stresses were increased proportionally to the crown height under oblique loading but showed little differences with three different crown heights under vertical loading. 3. In the crown, the highest stress areas were loading points under vertical loading, and the finish lines under oblique loading. 4. Under the oblique loading, the higher stresses were located in the fixture/abutment interface of the Bicon and Frialit-2 systems compared to the ITI and TG systems. Conclusions: The stress distribution patterns of each implant-abutment system had difference among them and adequate crown height/implant ratio was important to reduce the stresses around the implants.