• Title/Summary/Keyword: Mandibular positions

Search Result 114, Processing Time 0.021 seconds

Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load (하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석)

  • Bae, Sook-Jin;Chung, Chae-Heon;Jeong, Seung-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.

Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load (임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석)

  • Jang, Jong-Seok;Jeong, Yong-Tae;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

Three-year follow-up of full mouth rehabilitation with anterior implant surveyed bridges and distal extension removable partial denture (전방 임플란트 써베이드 고정성 보철물과 후방연장 국소의치를 이용한 전악 보철 치료의 3년 경과 관찰 증례)

  • Gil, Ki-Sung;Yi, Hyo-Gyoung;Kim, Kyoung-A;Lee, Jung-Jin;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.218-226
    • /
    • 2018
  • In partial edentulous patients, implant-assisted removable partial denture which provide additional retention and support by placing a small number of implants in strategic positions might be suitable treatment. This case of patient with loss of maxillary posterior teeth and moderate to severe wear of residual dentition, three implants were placed in the maxillary anterior edentulous area and then surveyed bridges were made including remaining anterior natural teeth. Posterior edentulous area was restored with distal extension removable partial denture (RPD). In addition, the worn mandibular natural teeth were restored with fixed prostheses. As a result, reduced vertical dimension and collapsed occlusal plane were rehabilitated, and improved functionally and aesthetically. The purpose of this case was to report the results of three-year follow-up of full mouth rehabilitation with anterior implant surveyed bridges and distal extension RPD.

Case Report : Botulinum Toxin Treatment in Oromandibular Dystonia (보툴리눔 톡신을 이용한 구강하악 근긴장이상증의 치료 증례)

  • Ryu, Ji-Won;Hong, Seong-Ju;Bae, Kook-Jin;Yoon, Chang-Lyuk;Ahn, Jong-Mo
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.4
    • /
    • pp.421-427
    • /
    • 2009
  • Oromandibular dystonia is a focal neurological movement disorder characterized by involuntary sustained and often painful muscle contraction, usually producing repetitive movements or abnormal positions of the mouth, jaw and.or tongue. Patients suffering from oromandibular dystonia often experience difficulties in chewing, swallowing and speaking, resulting from the impairment of mandibular movements. At present there is no etiologic treatment for oromandibular dystonia, because the pathophysiology of primary and focal dystonia is still incompletely understood. Many treatments such as medication, behavioral therapy, surgery are suggested to decrease the involuntary movements. But these success rates are relatively low and they have a lot of complications. many studies suggested that chemodenervation with botulinum toxin is the most effective treatment for oromandibular dystonia. We reported the 2 cases which were treated oromandibular dystonia with botulinum toxin and reviewed the orofacial movement disorders(especially oromandibular dystonia) and botulinum toxin treatment for oromanfibular dystonia.

INTERRELATIONSHIP BETWEEN MANDIBULAR CONDYLAR HEAD POSITION IN TRANSCRANIAL VIEW AND ARTICULAR DISC POSITION (경두개방사선사진에서의 하악과두 위치와 관절원판 위치간의 상호관계)

  • Ko Jae-Hee;Choi Soon-Chul;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.319-330
    • /
    • 1995
  • This study was designed to evaluate the interrelationship between the condylar head position in transcranial view and the articular disc position in the arthrography. The condylar positions were assessed by subjective method and linear measurement method on the transcranial view. The subjects for this study consisted of 24 symptomatic joints with normal disc position, 37 joints with anterior disc displacement with reduction and 44 joints with anterior disc displacement without reduction that were classified by arthrotomography under the fluoroscopic guidance. The interrelationship between the condylar head position in transcranial view and the articular disc position in the arthrography was evaluated by Chi square test. The obtained results were as follows : 1. There was no significant interrelationship between the position of condylar head in closed mouth state on transcraniaJ view and articular disc position in the arthrography (p>0.05). 2. There was no significant interrelationship between the changes of interarticular distance in 1 inch opening state and articular disc position in the arthrography (p>0.05). 3. There was no significant interrelationship between the position of condylar head related to the apex of articular eminence in 1 inch opening state and articular disc position in the arthrography(p>0.05). 4. There was significant interrelationship between the changes of interarticular distance that is assessed by linear measurement method in maximum opening state and articular disc position in the arthrography(p<0.05), but there was no significant interrelationship when the condylar head position was assessed by subjective method(p>0.05). 5. There was significant interrelationship between the degree of condylar translation in maximum opening state and articular disc position in the arthrography(p<0.05). 6. The correlation coefficient between two methods to assess the position of condylar head were 0.7989: the condylar head position in articular fossa in closed state, 0.6847: interarticular space in 1 inch opening state, 0.8965: the degree of condylar translation in 1 inch opening state, 0.5944: the changes of interarticular space in maximum opening state, 0.9215: the degree of condylar translation in maximum opening state.

  • PDF

Development and application of stent-based image guided navigation system for oral and maxillofacial surgery (구강외과 수술용 스텐트 기반 영상유도 수술 시스템의 개발)

  • Lee, Woo-Jin;Kim, Dae-Seung;Yi, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Myung-Jin;Lee, Jee-Ho
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.149-156
    • /
    • 2009
  • Purpose : The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. Materials and Methods : We devised a patient-specific stent for patient-to-image registration and navigation. Three-dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. Results : The accuracy over 8 anatomical landmarks showed an overall mean of $0.56{\pm}0.16\;mm$. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. Conclusion : The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  • PDF

Customized maxillary incisor position relative to dentoskeletal and soft tissue patterns in Chinese women: A retrospective study

  • Zhou, Xueman;Zheng, Yingcheng;Zhang, Zhenzhen;Zhang, Zihan;Wu, Lina;Liu, Jiaqi;Yang, Wenke;Wang, Jun
    • The korean journal of orthodontics
    • /
    • v.52 no.2
    • /
    • pp.150-160
    • /
    • 2022
  • Objective: To provide reliable prediction models based on dentoskeletal and soft tissue variables for customizing maxillary incisor positions and to optimize digitalized orthodontic treatment planning. Methods: This study included 244 Chinese women (age, 18-40 years old) with esthetic profiles after orthodontic treatment with fixed appliances (133 in group I: 1° ≤ The angle between the nasion [N]-A point [A] plane and the N-B point [B] plane [ANB] ≤ 4°; 111 in group II: 4° < ANB ≤ 7°). Dental, skeletal, and soft tissue measurements were performed on lateral cephalograms of the participants. Correlation and multiple linear regression analyses were used to determine the influence of dentoskeletal and soft tissue variables on maxillary incisor position. Results: The ideal anteroposterior position of the maxillary incisor varied between sagittal skeletal patterns. The position of the maxillary incisor correlated with the sagittal discrepancy between the maxilla and the mandible (ANB), protrusion of the midface, nasal tip projection, development of the chin, and inclination of both the maxillary and mandibular incisors. Distance from the maxillary central incisor to nasion-pogonion plane predicted using multiple linear regression analysis was accurate and could be a practical measurement in orthodontic treatment planning. Conclusions: Instead of using an average value or norm, orthodontists should customize a patient's ideal maxillary incisor position using dentoskeletal and soft tissue evaluations.

Treatment with upper complete denture and lower implant-fixed restorations on an elderly patient presenting fully edentulous maxilla and bilateral posterior edentulous mandible: a case report (상악 완전무치악 및 하악 양측 구치부 결손 고령환자에 대한 상악 가철성, 하악 고정성 보철치료: 증례보고)

  • Joseph Junesirk Choi;Richard Leesungbok;Suk-Won Lee;Phyo Ei Ei Htay;Jeong-yun Park;Jin-Young Chon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.284-292
    • /
    • 2023
  • Stable posterior occlusal support is crucial for adequate masticatory function and facial aesthetics. In elderly patients over the age of 65, masticatory ability has a significant impact on nutritional intake and overall health. This case report presents a prosthetic treatment of an elderly patient with edentulous maxilla and bilateral posterior edentulous mandible. The upper jaw was restored with a complete denture to establish an ideal occlusal plane, and the three-dimensional positions of the mandibular implants were determined accordingly. The implants were placed through computer-guided implant surgery and were immediately loaded with fixed provisional restorations. The implant-fixed zirconia final restorations were inserted in the lower posterior region, and the occlusal surface of posterior artificial teeth in the upper denture was substituted with cobalt-chrome alloy to resist occlusal wear. The patient's posterior occlusal support and masticatory function were promptly restored through this treatment process, and long-term stability against wear was also obtained.

Size and Retention of Tongue Bulb for Tongue Retaining Device (혀 유지구의 크기와 유지력 평가)

  • Park, Nam-Seon;Lee, Ki-Ho;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.283-292
    • /
    • 2007
  • In several treatment modalities for snoring and obstructive sleep apnea (OSA), oral appliances mainly including mandibular advancement appliance (MAA) and tongue retaining device (TRD) are recognized as a non-invasive, reversible alternative with favorable results. Tongue bulb is a major component of TRD which prevents the tongue from approaching the posterior wall of the pharynx and can be combined with MAA. Determination of tongue bulb size for the patient is important for therapeutic effect, but frequently needs time-consuming work. For effective fabrication and standardization of tongue bulbs, this study aimed to categorize tongue bulb size for healthy young men and to examine its relation with maximum retention force and with physical parameters including tongue-related variables. 36 non-snoring, asymptomatic young men with normal occlusion were voluntarily participated in this study (mean age: $24.47{\pm}2.58$ years). Experimental procedures consisted of prefabrication of tongue bulb set (20 types with a width of 27-36mm and thickness of 8 and 10 mm), determination of tongue bulb size and the maximum retention force for each subject, and measurement of physical parameters including body mass index (BMI), neck circumference and width, thickness and length of tongue. This study showed that there was significant difference of retention force among the bulb size-related groups both in upright and supine position (p<0.05) and that retention force increased with bulb size. Correlation of tongue bulb size with physical parameters was not clearly verified and there was no significant difference in retention force between upright and supine positions. Based on our results, it can be suggested that retention force relates with tongue bulb size, ultimately with tongue volume. A further study needs to be performed in the patients with snoring and OSA.

Changes in atlas position with Class ll activator treatment in Class II malocclusion patients (II급 부정교합자에서 액티베이터 사용에 따른 atlas의 위치 변화에 관한 연구)

  • Cho, Moon-Ki;Cha, Kyung-Suk;Chung, Dong-Hwa;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.44-55
    • /
    • 2007
  • Objective: Previous studies have reported that morphological features of the first cervical vertebra (atlas) have been associated with mandibular growth direction. The purpose of this study was to show the possible positional and morphological changes of the Atlas from activator treatment in Class II malocclusion patients. Methods: Lateral cephalometric radiograph tracings were made at initial, middle and final stages of treatment. Angular and linear measurements of skeletal and morphological features were measured on the anatomical landmarks and reference planes. Results: The skeletal effects of activator treatment on Class II malocclusion patients were evident on ramal height, body length, effective body length, ANB, and overjet. Clockwise rotation of the long axis of the Atlas was found in Group 1, but there was no inclination change of the Atlas in groups 2 and 3. There was no significant correlation between anterior and posterior positions of the atlas or morphological change in all groups. - except for posterior movements of the Atlas found in group 1. Conclusion: Clockwise rotation of the atlas axis resulted from activator treatment in Cl II malocclusion patients. Change in atlas axis can be thought of as an indicator for success of activator treatment.