• Title/Summary/Keyword: Mandibular first molar

Search Result 382, Processing Time 0.023 seconds

In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials

  • Choi, Yu-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.162-169
    • /
    • 2012
  • PURPOSE. Fracture of the veneering material of zirconia restorations frequently occurs in clinical situations. The purpose of this in vitro study was to compare the fracture strengths of zirconia crowns veneered with various ceramic materials by various techniques. MATERIALS AND METHODS. A 1.2 mm, $360^{\circ}$ chamfer preparation and occlusal reduction of 2 mm were performed on a first mandibular molar, and 45 model dies were fabricated in a titanium alloy by CAD/CAM system. Forty-five zirconia copings were fabricated and divided into three groups. In the first group (LT) zirconia copings were veneered with feldspathic porcelain by the layering technique. In the second group (HT) the glass ceramic was heat-pressed on the zirconia coping, and for the third group (ST) a CAD/CAM-fabricated high-strength anatomically shaped veneering cap was sintered onto the zirconia coping. All crowns were cemented onto their titanium dies with Rely $X^{TM}$ Unicem (3M ESPE) and loaded with a universal testing machine (Instron 5583) until failure. The mean fracture values were compared by an one-way ANOVA and a multiple comparison post-hoc test (${\alpha}$= 0.05). Scanning electron microscope was used to investigate the fractured interface. RESULTS. Mean fracture load and standard deviation was $4263.8{\pm}1110.8$ N for Group LT, $5070.8{\pm}1016.4$ for Group HT and $6242.0{\pm}1759.5$ N for Group ST. The values of Group ST were significantly higher than those of the other groups. CONCLUSION. Zirconia crowns veneered with CAD/CAM generated glass ceramics by the sintering technique are superior to those veneered with feldspathic porcelain by the layering technique or veneered with glass ceramics by the heat-pressing technique in terms of fracture strength.

THE EFFECTS OF EXTRACTIONS IN FACIAL VERTICAL CHANGES (발치가 안모의 수직변화에 미치는 영향)

  • Ma, Joon;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.6 s.65
    • /
    • pp.905-916
    • /
    • 1997
  • The purpose of this investigation were to evaluate facial vortical changes occurring in patients treated orthodontically with first premolar, second remolar and second molar extractions : to compare these changes with those occurring in patients treated orthodontically without extractions : and finally, to evaluate the effects of extractions in facial vortical changes. Cephalometric records of 50 male & female nonextraction patients and 88 male & female extraction patients were obtained from the department of orthodontics at Chosun University, College of Dentistry. The second molar fully erupted pPatients to have little variation according to growth were chosen as the sample for this investigation. For comparisons, the samples of 88 male & female extraction patients were subdivided into 42 first premolar extraction, 24 second premolar extraction, and 22 second molar extraction patients. Fourteen cephalometric measurements were selected to examine whether orthodontic extraction treatment led to vertical changes or not. The pretreatment and posttreatment lateral cephalographs were taken on the same radiographic unit. $SPSS/PC^+$ statistical program was used to compare and to analyze the changes between 'before & after' orthodontic treatment. The results of this study were as follows. 1. There were no statistical significances in any cephalometric measurements between 'before & after' orthodontic treatment regardless of orthodontic extractions for each group. 2. On average, the upper 6 to palatal Plane and the lower 6 to mandibular plane after orthodontic treatment were increased in all group. This means most of orthodontic mechanics are extrusive in nature. Especially, in orthodontic extraction. cases, it may be caused by orthodontic mechanics for space closure and alignments. 3. On average, in the second molar extraction group, the facial vertical dimension was increased after orthodontic treatment. It nay be induced as a result of moving the molars distally to gain enough space to correct the molar relationship and to simultaneously improve the deep bite. 4. There was no statistical significance between orthodontic extractions and facial vertical changes. This means that orthodontic extractions have no influence on facial vortical changes. 5. The cephalometric measurements with statistical significance in ficial vertical changes for each group were PP-MP, Op-MP, $\underline{1}$ to PP and $\overline{1}$ to MP.

  • PDF

Cortical bone thickness and root proximity at mandibular interradicular sites: implications for orthodontic mini-implant placement (하악의 교정용 미니 임플랜트 식립 부위에서의 피질골 두께와 치근간 거리: 3차원으로 재구성한 CT 영상을 이용한 연구)

  • Lim, Ju-Eun;Lim, Won-Hee;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.397-406
    • /
    • 2008
  • Objective: The purpose of this study was to provide clinical guidelines to indicate the best location for mini-implants as it relates to the cortical bone thickness and root proximity. Methods: CT images from 14 men and 14 women were used to evaluate the buccal interradicular cortical bone thickness and root proximity from mesial to the central incisor to the 2nd molar. Cortical bone thickness was measured at 4 different angles including $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, and $45^{\circ}$. Results: There was a statistically significant difference in cortical bone thickness between the second premolar/first permanent molar site, central incisor/central incisor site, between the first/second permanent molar site and in the anterior region. A statistically significant difference in cortical bone thickness was also found when the angulation of placement was increased except for the 2 mm level from the alveolar crest. Interradicular spaces at the 1st/2nd premolar, 2nd premolar/1st permanent molar and 1st/2nd permanent molar sites are considered to be wide enough for mini-implant placement without root damage. Conclusions: Given the limits of this study, mini-implants for orthodontic anchorage may be well placed at the 4 and 6 mm level from the alveolar crest in the posterior region with a $30^{\circ}$ and $45^{\circ}$ angulation upon placement.

Changes in periodontium after extraction of a periodontally-involved tooth in rats

  • Kim, Dong-Ju;Cha, Jae-Kook;Yang, Cheryl;Cho, Ahran;Lee, Jung-Seok;Jung, Ui-Won;Kim, Chang-Sung;Lee, Seung-Jong;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.5
    • /
    • pp.158-165
    • /
    • 2012
  • Purpose: Recent interest has focused on intentional replantation to restore an original tooth. Some studies have shown successful results with intentional replantation for periodontally involved teeth. For long-term success of replantation, a healthy periodontal status of the recipient site is required so that delayed replantation is more suitable for periodontally involved teeth. To reveal the ideal timing for delayed replantation of periodontally involved teeth, the healing process of extraction sockets after extraction of periodontitis-induced teeth in rats was evaluated. Methods: Twenty-eight rats were randomly divided into two groups: a control group (n=8) and test group (n=20). In the test group, periodontitis was induced by a ligature around the cervix of the mandibular first molar of all of the rats. Two weeks later, the mandibular first molars were extracted in all of the animals. The animals were sacrificed on days 0, 3, 7, and 10 after extraction and histological and immunohistochemical analysis was performed. Results: In histological analysis of the test group, inflammatory cell infiltrate was found abundantly in the remaining periodontium 3 days after tooth extraction and decreased gradually at later time points. In immunohistochemical analysis of the test group, both interleukin-6 (IL-6) and, tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) were numerous in the furcation area at each postextraction day. IL-6 was stained more heavily between 3 and 7 days after extraction; at day 10 after extraction, little staining was observed. TNF-${\alpha}$ staining was more intense at 3 days after extraction and gradually weakened at later points in time. Conclusions: Within the limits of this study, it takes at least 10 days to resolve periodontal inflammation in rat extraction sockets.

Extraction of mandibular third molars: relationship of preoperative anxiety with body mass index, serum high-sensitivity C-reactive protein levels, and visual analog scale scores and predictors of postoperative complications

  • Eunjee Lee;Yu-Jin Jee;Jaewoong Jung;Mu Hang Lee;Sung ok Hong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.5
    • /
    • pp.252-261
    • /
    • 2023
  • Objectives: Patients undergoing oral surgery exhibit high anxiety, which may elevate their cortisol levels and affect postoperative recovery. Overweight patients are often encountered in the dental clinic due to the increasing prevalence of overweight. We aimed to investigate the relationships between preoperatively assessed body mass index (BMI), serum cortisol and high-sensitivity C-reactive protein (hs-CRP) levels, and visual analog scale (VAS) scores and preoperative anxiety in patients undergoing mandibular third molar (MM3) extraction and to identify predictors of postoperative complications. Patients and Methods: We analyzed 43 patients (age, 20-42 years) undergoing MM3 extraction. At the first visit, patients completed the Modified Dental Anxiety Scale (MDAS) and Amsterdam Preoperative Anxiety and Information Scale (APAIS) questionnaires. Their BMI and VAS scores were also calculated. The participants underwent blood tests 1 hour before MM3 extraction. On the first postoperative day, the participants' VAS scores and serum hs-CRP levels were reevaluated. Results: We found that BMI was significantly correlated with preoperative VAS scores. Further, BMI and preoperative hs-CRP levels were significantly correlated among women and patients undergoing extractions of fully impacted MM3s. No correlations were found between serum cortisol and other variables. The preoperative MDAS and VAS scores were significantly positively correlated, especially among patients undergoing extractions of fully impacted MM3s. Multiple linear regression showed that BMI and the eruption status of the MM3 were significant predictors of postoperative hsCRP levels and VAS scores, respectively. Conclusion: In MM3 removals, patients with higher BMI showed elevated hs-CRP and higher VAS scores before surgery. Patients with higher anxiety among those undergoing extractions of fully impacted MM3s showed higher preoperative VAS scores. The two main predictors of postoperative complications were BMI and MM3 eruption status.

Repeated failure of implants at the same site: a retrospective clinical study

  • Kang, Dong-Woo;Kim, So-Hyun;Choi, Yong-Hoon;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.27.1-27.9
    • /
    • 2019
  • Background: Implants are becoming the first choice of rehabilitation for tooth loss. Even though they have a high success rate, failures still occur for many reasons. The objective of this study is to analyze the reasons for recurring failure at the same site and the results of re-implantation. Methods: Thirteen patients (11 males and 2 females, mean age 60 ± 9.9 years) who experienced implant surgery failure at the same site (same tooth extraction area) two or more times in the Department of Oral and Maxillofacial Surgery, Seoul National University Bundang Hospital, between 2004 and 2017 were selected. The medical records on a type, sites, diameter, and length of implants; time and estimated cause of failure; and radiographs were reviewed. Data were collected and analyzed retrospectively, and the current statuses were evaluated. Results: A total of 14 implants experienced failure in the same site more than two times. Twelve implants were placed in the maxilla, while 2 implants were placed in the mandible. The maxillary molar area was the most common site of failure (57.1%), followed by the mandibular molar, anterior maxilla, and premolar areas (14.3% each). The first failure occurred most commonly after prosthetic treatment (35.7%) with an average period of failure of 3.8 months after loading. Ten cases were treated as immediate re-implantation, while the other 4 were delayed reimplantation after an average of 3.9 months. The second failure occurred most commonly after prosthetic treatment (42.9%), with an average of 31 months after loading; during the healing period (42.9%); and during the ongoing prosthetic period (14.3%). In 3 cases (21.4%), the treatment plan was altered to an implant bridge, while the other 11 cases underwent another implant placement procedure (78.6%). Finally, a total of 9 implants (64.3%) survived, with an average functioning period of 60 months. Conclusions: Implants can fail repeatedly at the same site due to overloading, infection, and other unspecified reasons. The age and sex of the patient and the location of implant placement seem to be associated with recurring failure. Type of implant, bone augmentation, and bone materials used are less relevant.

GARRE'S OSTEOMYELITIS IN CHILDREN (소아에서의 Garre 골수염)

  • Woo, Se-Eun;Kim, Young-Jin;Kim, Hyun-Jung;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.4
    • /
    • pp.413-420
    • /
    • 2011
  • Garre's osteomyelitis is associated with bacterial infection and bone necrosis resulting from obstruction of blood supply. The most common cause for Garre's osteomyelitis is odontogenic infection that originates from periodontal tissue or dental pulp. Subperiosteal abscess may also cause Garre's osteomyelitis in the progress of the infection. Mandible is more often affected than maxilla, most commonly in the permanent first molar region of mandible. Clinically, it results in a hard swelling over the jaw, producing facial asymmetry. Meanwhile, radiograph shows a characteristic feature of irregular pulpal cavity, showing new periosteal proliferation located in successive layers to the condensed cortical bone on stimulated site. The treatment method for Garre's osteomyelitis are removal of the infection source, root canal treatment, antibiotic medication, and incision and drainage. This report presents a case of Garre's osteomyelitis under 15 years old. The patient was successfully treated by antibiotic medication accompanied with root canal treatment. Since the symptom of pediatric patients is less severe than adult, careful diagnosis with history taking and clinical examination is necessary. Furthermore long-term follow-up examination is needed to prevent recurrence even after the symptom disapears.

Fracture resistance of implant- supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns

  • Elshiyab, Shareen H;Nawafleh, Noor;Ochsner, Andreas;George, Roy
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2018
  • PURPOSE. The aim of this in vitro study was to investigate the fracture resistance under chewing simulation of implant-supported posterior restorations (crowns cemented to hybrid-abutments) made of different all-ceramic materials. MATERIALS AND METHODS. Monolithic zirconia (MZr) and monolithic lithium disilicate (MLD) crowns for mandibular first molar were fabricated using computer-aided design/computer-aided manufacturing technology and then cemented to zirconia hybrid-abutments (Ti-based). Each group was divided into two subgroups (n=10): (A) control group, crowns were subjected to single load to fracture; (B) test group, crowns underwent chewing simulation using multiple loads for 1.2 million cycles at 1.2 Hz with simultaneous thermocycling between $5^{\circ}C$ and $55^{\circ}C$. Data was statistically analyzed with one-way ANOVA and a Post-Hoc test. RESULTS. All tested crowns survived chewing simulation resulting in 100% survival rate. However, wear facets were observed on all the crowns at the occlusal contact point. Fracture load of monolithic lithium disilicate crowns was statistically significantly lower than that of monolithic zirconia crowns. Also, fracture load was significantly reduced in both of the all-ceramic materials after exposure to chewing simulation and thermocycling. Crowns of all test groups exhibited cohesive fracture within the monolithic crown structure only, and no abutment fractures or screw loosening were observed. CONCLUSION. When supported by implants, monolithic zirconia restorations cemented to hybrid abutments withstand masticatory forces. Also, fatigue loading accompanied by simultaneous thermocycling significantly reduces the strength of both of the all-ceramic materials. Moreover, further research is needed to define potentials, limits, and long-term serviceability of the materials and hybrid abutments.

Impact of surface roughness of gypsum materials on adaptation of zirconia cores

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Sa-Hak
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.199-206
    • /
    • 2015
  • PURPOSE. The present study investigated the influences of various gypsum materials on the precision of fit of CAD/CAM-fabricated prostheses and analyzed their correlation with surface roughness. MATERIALS AND METHODS. The master model of the mandibular right first molar was replicated, and four experimental groups based on two types of Type IV stone (GC Fujirock EP, Die keen) and two types of scannable stone (Aesthetic-Basegold, Everest Rock) were created to include a total of 40 specimens, 10 in each group. The surface roughness of the working models for the respective experimental groups was measured. Once the zirconia cores had been fabricated, the marginal and internal fits were measured with a digital microscope using the silicone replica technique. The mean and standard deviation of the respective points of measurement were computed and analyzed through the one-way ANOVA and Tukey's HSD test. The correlation between surface roughness and the precision of fit of the zirconia core was analyzed using the Pearson correlation analysis (${\alpha}$=.05). RESULTS. The zirconia cores fabricated from the scannable stone working models exhibited a superior precision of fit as compared to those fabricated from the Type IV stone working models. The correlation analysis results showed a clear positive correlation between surface roughness and the precision of fit of zirconia cores in all of the experimental groups (P<.05). CONCLUSION. The results confirmed that the surface roughness of dental working models has a decisive influence on the precision of fit of zirconia cores.

Qualitative and quantitative evaluation of root injury risk potentially burdening insertion of miniscrew implants

  • Antoszewska, Joanna;Trzesniewska, Paulina;Kawala, Beata;Ludwig, Bjorn;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.112-120
    • /
    • 2011
  • Objective: Microscrew implants (MSls) offer many advantages, but some complications are known to occur during their insertion. One of the most commonly reported complications is root injury. Our aim was to identify factors associated with root injury and to evaluate their qualitative and quantitative values. Methods: Thirty-five orthodontists placed MSls (AbsoAnchor$AbsoAnchor^{(R)}$, Dentos Co. Ltd, Daegu, Korea) in the upper jaw of typodonts, labially between the second premolar and the first molar, in low and high vertical positions. Root contacts were counted, and distances between MSI apices and roots were measured. Fear level of the orthodontists was surveyed before and after the experiment. Wilcoxon's test, chi-square test, and Mann-Whitney test were used for statistical analysis. Results: Overall root contact rate of MSI insertion was 23.57%. The root contact rate was significantly higher in MSls inserted at $90^{\circ}$ (45.71%) than at $30^{\circ}$ (1.43%). The distance between the dental root and MSI also increased significantly in MSls inserted at $30^{\circ}$. Mean fear level before MSI insertion (4.6) significantly decreased after insertion (3.2); the causative factors were risk of injury to dental root and maxillary sinus or mandibular canal. Conclusions: Root injury is relatively rare, and oblique angulation reduces the risk of root and MSI contact.