• Title/Summary/Keyword: Mandibular First Molar

Search Result 382, Processing Time 0.027 seconds

Comparison of interradicular distances and cortical bone thickness in Thai patients with Class I and Class II skeletal patterns using cone-beam computed tomography

  • Khumsarn, Nattida;Patanaporn, Virush;Janhom, Apirum;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.117-125
    • /
    • 2016
  • Purpose: This study evaluated and compared interradicular distances and cortical bone thickness in Thai patients with Class I and Class II skeletal patterns, using cone-beam computed tomography (CBCT). Materials and Methods: Pretreatment CBCT images of 24 Thai orthodontic patients with Class I and Class II skeletal patterns were included in the study. Three measurements were chosen for investigation: the mesiodistal distance between the roots, the width of the buccolingual alveolar process, and buccal cortical bone thickness. All distances were recorded at five different levels from the cementoenamel junction (CEJ). Descriptive statistical analysis and t-tests were performed, with the significance level for all tests set at p<0.05. Results: Patients with a Class II skeletal pattern showed significantly greater maxillary mesiodistal distances (between the first and second premolars) and widths of the buccolingual alveolar process (between the first and second molars) than Class I skeletal pattern patients at 10 mm above the CEJ. The maxillary buccal cortical bone thicknesses between the second premolar and first molar at 8 mm above the CEJ in Class II patients were likewise significantly greater than in Class I patients. Patients with a Class I skeletal pattern showed significantly wider mandibular buccolingual alveolar processes than did Class II patients (between the first and second molars) at 4, 6, and 8 mm below the CEJ. Conclusion: In both the maxilla and mandible, the mesiodistal distances, the width of the buccolingual alveolar process, and buccal cortical bone thickness tended to increase from the CEJ to the apex in both Class I and Class II skeletal patterns.

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.5
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

Posterior maxillary segmental osteotomy for management of insufficient intermaxillary vertical space and intermolar width discrepancy: a case report

  • Baeg, SeungWoo;On, SungWoon;Lee, JeongKeun;Song, SeungIl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.28.1-28.6
    • /
    • 2016
  • Backgrounds: Insufficient intermaxillary space is caused by non-restoration following tooth extraction in the past, and this involves eruption of the opposing teeth and changes of the arch structure. Such cases are difficult just by a simple prosthetic approach, and diversified treatment plans should be established. Among these, posterior maxillary segmental osteotomy (PMSO) is an efficient treatment option than extraction of opposing teeth as it surgically repositions multiple erupted teeth and alveolar bone. PMSO can preserve the natural teeth; therefore, it is being regarded as a treatment method which can improve insufficient intermaxillary space significantly. Case presentation: In this case report, the first patient received PMSO in order to place an implant in the mandibular edentulous space after decreased vertical dimension is restored, and the second patient received PMSO along with orthodontic treatment to obtain the intermaxillary space and balance the interarch molar width. Conclusion: PMSO is the treatment of choice when occlusion is compromised in the presence of decreased vertical dimension or arch length discrepancy.

Evaluation of the marginal and internal fit of lithium disilicate crowns fabricated by different scanning methods (다른 스캐닝 방법으로 제작된 리튬 디실리케이트 단관의 변연 및 내면 적합도 평가)

  • Kim, Jae-Hong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.36 no.2
    • /
    • pp.75-81
    • /
    • 2014
  • Purpose: This study was to compare adaptations of lithium disilicate CAD/CAM crowns fabricated with different scanning systems. Methods: This study selected the mandibular right first molar as an abutment for experiments and produced 10 working models. Lithium disilicate crowns appropriate for each abutment were produced by using a CEREC$^{(R)}$ CAD/CAM system. The independent t-test was then used to compare and analyze the data obtained from the two groups(${\alpha}$=0.05). Results: Mean(SD) adaptation were $86.93(22.82){\mu}m$ for the InS group, $88.42(26.77){\mu}m$ for the ExS group. They were no statistically significant differences between groups for adaptation(p>0.05). Conclusion: Within the limitations of this study, the results suggest that the accuracy of all investigated optical scanner were satisfactory for clinical use. Further assessment and improvement of the lithium disilicate ceramic for the fabrication of FPDs is evidently still required.

LARGE COMPLEX ODONTOMA OF MAXILLARY SINUS: A CASE REPORT AND LITERATURE REVIEW (상악동에 발생한 큰 복잡성 치아종 : 증례보고 및 문헌 고찰)

  • Kim, Byung-Wook;Jung, Jae-Hyung;Kim, Moon-Key;Lee, Hyun-Jung;Kim, Jung-Ihn;Lee, Mi-Kyung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.2
    • /
    • pp.179-182
    • /
    • 2006
  • The term odontoma, first introduced by Broca, was originally applied to all odontogenic tumors. Related to the clinical and histological differences, 2 groups of odontoma were defined: compound odontoma and complex odontoma. Complex odontoma is more common in the mandible than in the maxilla, usually occuring in the mandibular premolar-molar area. And this consists of small mass of irregularly arranged enamel, dentine, cementum, and connective tissue, but tooth-like structures are not found. In our case, 34 year old man was diagnosed as the complex odontoma of maxillary sinus by the physical exam, Panex, and C.T scan. We sectioned and removed it, and then confirmed the diagnosis histopathologically. Its uncommon location and size made us report that case and review the literature concerned.

Comparison of marginal gap of monolithic CAD/CAM-generated crowns according to the ceramic materials for CEREC system (CEREC system에서 사용하는 세라믹 소재로 가공된 CAD/CAM 전부도재관의 변연간격 비교분석)

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.119-125
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate the marginal gap of all-ceramic crowns fabricated by CEREC$^{(R)}$ in-office CAD/CAM system. Methods: The mandibular first molar was selected as the abutment for the experiments. Thirty working models were prepared. VITA Mark II(VM) and VITA Enamic(VE), LAVA Ultimate(LU) blocks were milled using CEREC MCXL with CEREC 3D system to construct 10 crowns for each groups. To measure marginal gap, milled restorations were examined under digital microscope with scale under 160x magnifications. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${\alpha}=0.05$). Results: There was no significant difference in the marginal gap regarding to ceramic materials(p>0.05). Conclusion: Single crowns fabricated using CEREC in-office CAD/CAM system provided clinically acceptable marginal gap. This confirmed that the type of ceramic material used does not determine the precision of fit of a prosthesis.

The Effect of Masticatory Muscle Fatigue on the Occlusal Contact Stability and Masticatory Muscle Actibities (저작근의 피로가 치아접촉안정성 및 저작근활성에 미치는 효과)

  • Hye-Yeong Kim;Sun-Ha Kim;Jae-Kap Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.17 no.1
    • /
    • pp.41-50
    • /
    • 1992
  • The authors performed a experimental study to evaluate the effects of masticatory muscle fatigue on tooth contact and masticatory muscle activity in 26 normal healthy women. The experimental masticatory muscle fatigue was induced by unilateral biting of 5kg force on mandibular first molar. The results were as follows : 1. The initial symptom related to muscle fatigue pain appeared in 85.19 seconds of isometric contraction and the endurance time of isometric contraction was 203.15 seconds. 2. The pain occurred more frequently in masseter region than in temporal region. In masseter pain the incidence was almost equal between both sides, whereas the temporal pain was more in contralateral side. 3. The spontaneity and the symmetry of tooth contact during maximum clenching were reduced after isometric unilateral biting. 4. After induction of experimental muscle fatigue, the EMG activities of masseter muscles of both sides and ipsilateral temporal muscle showed the tendency of decreasing activities. 5. The asymmetry indicies of masseter and temporal muscles were reduced after isometric bilateral biting.

  • PDF

Retrieval of a separated nickel-titanium instrument using a modified 18-guage needle and cyanoacrylate glue: a case report

  • Andrabi, Syed Mukhtar-Un-Nisar;Kumar, Ashok;Iftekhar, Huma;Alam, Sharique
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.2
    • /
    • pp.93-97
    • /
    • 2013
  • During root canal preparation procedures, the potential for instrument breakage is always present. When instrument breakage occurs, it leads to anxiety of the clinician and as well as a metallic obstruction of the canal which hinders further cleaning and shaping. Separated instruments must always be attempted for retrieval and if retrieval is not possible bypass should be tried. With the increased use of nickel-titanium (NiTi) instruments the incidence of separated instruments has increased. A considerable amount of research has been done to understand the various factors related to the fracture of NiTi instruments to minimize its occurrence. This paper presents a review of the literature regarding the fracture of NiTi instruments and also describes a case report showing the use of a modified 18-guage needle and cyanoacrylate glue to retrieve a separated NiTi instrument from the mesiolingual canal of a mandibular first molar.

Periosteal reaction as a crucial radiographic finding for desmoplastic fibroma of the jaw bone in children: A case report

  • Motevasseli, Safa;Yousefi, Zahra;Kajan, Zahra Dalili;Modanlou, Reza;Roudbari, Niousha
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.319-326
    • /
    • 2022
  • This report presents the case of a 5-year-old boy with a hard swelling on the right side of the mandible body. An important point of this case is that the primary imaging finding was fine spicules in the inferior border of the mandible on panoramic radiography without significant changes in bone density. Cone-beam computed tomography views revealed a lytic lesion on the lingual side of the right mandibular body with the destruction of the lingual cortex and periosteal reaction from the midline to the first molar area. Careful attention to this radiographic finding in the primary stage in the absence of other significant imaging findings, particularly in children, could result in the early diagnosis of desmoplastic fibroma. Therefore, a better prognosis can be expected following early surgical treatment.

Ingestion and surgical retrieval of an endodontic file: a case report

  • Devon Marta Ptak;Elinor Alon;Robert Bruce Amato;Julia Tassinari;Adrian Velasquez
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.4
    • /
    • pp.32.1-32.8
    • /
    • 2023
  • Ingestions and aspirations of foreign bodies are rare, but do occasionally occur during dental treatment. Although reports exist, few include photos demonstrating the extensive surgical intervention that may be necessary to manage such events. Perhaps this lack of visualization, and associated lack of awareness, is one of the reasons some clinicians still provide nonsurgical root canal therapy (NSRCT) without a rubber dam. This case report outlines the medical treatment of a 30-year-old male who initially presented to a general dentist's office (not associated with the authors) for NSRCT of their mandibular right first molar. A rubber dam was not used for this procedure, during which the accidental ingestion of an endodontic K-file occurred. The patient was subsequently hospitalized for evaluation and treatment, consisting of numerous imaging studies, endoscopic evaluation, and surgical removal of the file from his small intestine. The ingestion of foreign bodies, and the associated complications, can be reduced through the routine use of a rubber dam, which is considered the standard of care for NSRCT. This case graphically illustrates the potential consequences associated with deviating from the standard of care and should remind clinicians that a rubber dam is necessary for all cases of NSRCT.