• Title/Summary/Keyword: Management area in non-point source

Search Result 109, Processing Time 0.028 seconds

A Study for the Selection Method of Control Area of Nonpoint Pollution Source (비점오염원 관리지역의 선정 기법에 관한 연구)

  • Park, Sanghyun;Jeong, Woohyeok;Yi, Sangjin;Lim, Bongsu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.761-767
    • /
    • 2010
  • This study introduces a model of territorial analysis on Chungcheongnam-do Nonsan-chun valley area, which gives an example of a method of selecting the management area for non-point pollution source from land use to help eliminate its source. High discharge load per unit area signify high level of land ratio with high level of basic unit of development load (including factory sites, school sites, roadways), which mean that there are a significant level of urbanization. It is these areas with the examination of the water quality of the nearby river that should be considered as the management area for non-point pollution source. Thus, the management area for non-point pollution source should be sought in areas with high discharge load per unit area and high density of water pollution area. When level of drainage is high the pollution density level is relatively lower, and when the level of drainage is low the density level is relatively higher. The level of pollution from non-point pollution source is much lower with more water flowing through. The possible non-point pollution source areas that were selected with these standards were then examined with the distance from the river, the slope angle, land usage, elevation, BOD discharge density load, T-N discharge density load, T-P discharge density load, and were given a level one through five. Out of the possible areas Nonsan-si Yeonmu-eup Anshim-li was the densest area, and it was given level one. The level one area should be examined further with the field analysis to be selected as the actual management area for non-point pollution source.

A Study on Landscape Improvement of Cut-Slopes and Management of Non-Point Pollution Using Coir-Blocks (코이어블록(Coir-Blocks)을 이용한 절토사면의 경관개선 및 비점오염원 관리에 관한 연구)

  • Lee, Kwan-Choon;Park, Yool-Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.5
    • /
    • pp.27-36
    • /
    • 2015
  • This study was conducted to grasp the effect of afforestation of cut slope using coir blocks on the improvement of scenery and the management of non point pollution source. Total four experimental tanks such as general soil slope, coir blocks, installation slope, slope refilling the inside of coir blocks slope with pebble, slope refilling the inside of coir blocks with soil and plant were installed, pollution source water was supplied and the possibility of reduction management of non point pollution source was analyzed at four items of COD, SS, T-N, T-P and main results drawn from this study are as follows. In conclusion, biodegradable materials like coir blocks and soil and plant layers are judged to be helpful in reduction management of non point pollution source inflowing to water space from land area. Thus, the reduction of non point pollution source occurring at land area is thought to be fully controlled at the cut slope, the space prior to inflowing to water ecological space like a stream or a swamp area.

Improvement on Management of Non-point Source Pollution for Reasonable Implementation of TMDL - Focusing on Selection of Non-point Source Pollution Management Region and Management of Non-point Source Pollutant - (수질오염총량관리제의 합리적인 시행을 위한 비점오염원관리 개선방안 - 비점오염원 관리지역 선정 및 비점오염물질 관리를 중심으로 -)

  • Yi, Sang-Jin;Kim, Young-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.10
    • /
    • pp.719-723
    • /
    • 2014
  • For effective implementation of total maximum daily load (TMDL), this study presented the improving plans of non-point source pollution management including the classification of non-point source pollution, calculation of non-point source pollution load (generated, discharged), selection of non-point source pollution management regions and management of non-point source pollutant. First of all, the definition of point source pollution and non-point source pollution based on the legal and scientific viewpoint should be precisely classified and managed. Especially, the forest, grassland and river without occurrence of environmental damage by activity of business and human should be separately classified natural background pollutants. The unit for generated and discharged non-point source pollution should be preferentially changed according to actual condition of watershed. The calculation methods of generated and discharged non-point source pollution should be corrected consideration on the amount and duration of rainfall. While the TMDL is implemented, non-point source pollution management regions should be selected in the watersheds exceed the targeted water quality standards by the rainfall. The non-point source pollution management regions should be selected in the minimal regions where have high values of discharged non-point source pollution density in the urban area, farmland and site area except forest, grassland in the whole watershed. The non-point source pollutant treatment facilities, which take into consideration non-point source pollution load per unit area, duration of the excess concentration, realizable possibility of treatment, effectiveness of treatment cost versus point source pollutant, should be established in the regions with a large generated non-point source pollution load and a high concentration of water quality exceed the targeted water quality standards by the rainfall.

Stormwater Runoff Characteristics of Non-point Source Pollutants according to Landuse of Urban Area (도시지역 토지이용에 따른 비점원 오염물질 유출특성)

  • Jeong, Dong-Hwan;Shin, Dongseok;Rhew, Doughee;Jung, Dongil
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.6
    • /
    • pp.525-532
    • /
    • 2007
  • In order to establish and implement the total maximum daily load (TMDL) management plan in Korea, it is necessary to set the source units and calculate discharge loads for non-point source pollutants such as BOD, COD, SS, TN and TP. This study analysed the corelation between stormwater runoff characteristics and event mean concentrations (EMCs) of non-point source pollutants. As the result of the corelation analysis, we knew that all the antecedent dry days (ADD) and the rainfall correlated lowly with non-point source pollutants in the urban areas such as resident area, industrial area, business area, road area and parking area. Therefore, it is necessary to get all samples from stormwater starting point to stormwater ending point and standardize the sampling method of stormwater in order to obtain more accurate EMCs for landuse.

Application of SWMM for Management of the Non-point Source in Urban Area -Case Study on the Pohang City- (도시지역 비점오염원 관리를 위한 SWMM의 적용 -포항시를 대상으로-)

  • Lee, Jae-Yong;Jang, Seong-Ho;Park, Jin-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.247-254
    • /
    • 2008
  • Non-point source pollution that originates from surface applied chemicals in either liquid or solid form is a part of urban activities and it appears in the surface runoff caused by rainfall. This study investigates the characteristics of non point source pollution in relation to storm events and the first washing effect in the Study area, which is comprised of different land use types. Then, a Best Management Practices (BMP) model, for urban areas, is applied with the Storm water Management Model (SWMM) Windows Interface which was developed by the EPA in the USA. During the storm event analysis of the hydrographic and pollutographic data showed that the peak of pollutants concentration was within the peak flow, 30 to 60 minute into the storm event in the Study area. The results of simulation using SWMM Windows Interface, Structure Techniques as applied in the study were highly efficient for removal of pollutants. Predicted removal efficiency was 26.0% for SS, 22.1 for BOD, 24.1% for COD, 20.6% for T-N, and 21.6% for T-P, respectively.

Evaluation of the Effectiveness of Low Impact Development Practices in an Urban Area: Non-point Pollutant Removal Measures using EPA-SWMM (EPA-SWMM을 이용한 LID 기법의 비점오염 저감효과 분석)

  • Cho, SeonJu;Kang, MinJi;Kwon, Hyeok;Lee, JaeWoon;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.466-475
    • /
    • 2013
  • Non-point source pollution management is one of the most important issues in Korean water quality/watershed management. In recent years, Low Impact Development (LID) has emerged as an effective approach to control stormwater in an urban area. This study illustrates how to design and evaluate the effect of non-point pollutant management using EPA-SWMM LID module and suggests design parameters for modeling LID facilities. In addition, optimal installation locations of LID can be determined by a simple distributed hydrologic model by using SWMM for a long-term.

Study on the Runoff Characteristics of Non-point Source Pollution in Municipal Area Using SWMM Model -A Case Study in Jeonju City (SWMM모델을 이용한 도시지역 비점오염원의 유출특성 연구 -전주시를 대상으로)

  • Paik Do-Hyson;Lim Young-Hwan;Choi Jin-Kyu;Jung Paul-Gene;Kwak Dong-Heui
    • Journal of Environmental Science International
    • /
    • v.14 no.12
    • /
    • pp.1185-1194
    • /
    • 2005
  • The runoff characteristics of non-point source pollutions in the municipal area of Jeonju were investigated and analyzed by using the SWMM (Storm Water Management Model). The flow rates and water qualities of runoff from two types of drainage conduits were measured respectively. One was a conventional combined sewer system and the other was a separated sewer system constructed recently From August to November in 2004, investigations on two rainfall events were performed and flow rate, pH, BOD, COD, SS, T-N and T-P were measured. These data were also used for model calibration. On the basis of the measured data and the simulation results by SWMM, it is reported that $80-90\%$ of pollution load is discharged in the early-stage storm runoff. Therefore, initial 10-30 mm of rainfall should be controlled effectively for the optimal treatment of non-point source pollution in urban area. Also, it was shown that the SWMM model was suitable for the management of non-point source pollution in the urban area and for the analysis of runoff characteristics of pollutant loads.

Runoff Characteristics of Non-point Pollutants Source in Suwon City (수원시 비점오염물질의 유출 특성)

  • Chi, Hong-Jin;Lee, Sang-Eun;Lee, Jae-Dong
    • Journal of Environmental Science International
    • /
    • v.22 no.4
    • /
    • pp.493-505
    • /
    • 2013
  • This study was to investigate the runoff characteristics of non-point pollutants source at the urban area in Suwon city. The highest T-N and T-P concentration of rainfall runoff observed in agricultural area. In residential area, the highest $BOD_5$ and SS concentration of rainfall runoff was investigated. During rainfall events, the peak concentrations of SS and $BOD_5$ were observed after 1~2 hours of rainfall in urban area. Whereas, the peak concentrations occurred within 1~2 hours after rainfall and then the highest concentrations of SS and $BOD_5$ sharply decreased, showing strong first flush effect in urban area. The EMC results indicated that the highest value of T-N and T-P in agricultural area was observed. While residential area was shown the lowest EMC value as T-N and T-P. Non-point pollutant loads on the land use types in urban area were investigated in the order of residential>industrial>agricultural>highway. $BOD_5$ and SS loads on urban watershed were investigated in the order of Suwon>Hwangguji>Seoho>Wonchunri. Whereas, T-N and T-P loads on urban watershed were investigated in the order of Hwangguji>Suwon>Wonchunri>Seho.

Characteristics of Pollutant Loads in Saemangeum Watershed Using HSPF (논문 - HSPF를 이용한 새만금 유역의 오염부하 특성)

  • Jung, Ji-Yeon;Shin, Yu-Ri;Choi, Jung-Hoon;Choi, In-Kyu;Yoon, Chun-Gyeong;Son, Yeong-Kwon
    • KCID journal
    • /
    • v.18 no.2
    • /
    • pp.54-65
    • /
    • 2011
  • This study was performed to analyze the influence of pollutant loads characteristics on the point and non-point sources in Saemangeum watershed area using Hydrological Simulation Program, Fortran (HSPF). The simulation items were flow, BOD, T-N, and T-P(2007~2010). The pollutant loads trend reflects the precipitation. Specifically, the point source loads were almost constant, but the non-point source loads were influenced in the precipitation. It was found that the effect of non-point source is larger than point source. The water quality had a clear trend by the season. However, pollutant loads did not show distinct seasonal changes. The reason is that the pollutant concentration is diluted by the increased flow at summer season. Therefore, it is important to control the non-point source in order to manage water quality in the region. For the management of Saemangeum lake, it is need to control of supplied pollutant loads from Saemangeum watershed.

  • PDF

Non-point Source Impact Analysis through Linkage of Watershed Model and River Water Quality Model (유역모형과 하천수질모형의 연계를 통한 비점오염원 영향분석)

  • Choi, Hyun Gu;Kim, Dong Il;Kim, Ji Eun;Han, Kun Yeun
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.1
    • /
    • pp.25-36
    • /
    • 2011
  • In this study, the accurate water quality analysis in rivers, including the non-point source is performed. First of all, watershed model, SWAT(Soil and Water Assessment Tool) was applied to analyze the impact of the non-point source in study area. And then, water quality analysis integrating the point source and the non-point source is implemented using QUALKO model. For more exact simulation, it should be the calibration and verification of variables and parameters which are needed for simulation. In addition, the importance of considering the non-point source was confirmed in river water quality simulation. BOD, TN, TP were analysed, and the results shows that BOD, TN and TP concentration was increased to 16.8%, 8.2% and 25.8% respectively. The more accurate estimate will be carried if use of reliable measurements and watershed simulation be done in models linking process. The suggested technique will improve the accuracy of the water quality analysis. The methodologies presented in this study will contribute to basin-wide water quantity and quality management.