• Title/Summary/Keyword: Malodorous compound

Search Result 13, Processing Time 0.031 seconds

Odor Characteristics and Concentration of Malodorous Volatile Organic Compounds Emitted from a Sewer and Its Outlet (하수관거 및 토구에서 발생하는 휘발성 유기화합물 악취 특성)

  • Park, Sang Jin;Kwon, Soo Youl
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.6
    • /
    • pp.457-466
    • /
    • 2017
  • Objectives: This study was carried out to investigate the characteristics of volatile organic compounds (VOCs) emitted from sewerage facilities such as a sanitary sewers, outlets, and catch basins. In addition, the dominant malodorous VOCs among the compounds in this study were studied. Methods: Waste gas samples were collected at 27 points in a sanitary sewer in commercial and residental areas. The concentrations of seven volatile organic compounds, including benzene and toluene, in the samples were analyzed by gas chromatograph mass spectrophotometer (GC/MS). Odor concentrations were estimated using the concentration data of the VOCs and each compound's threshold limit value. Results: As a result, it appeared that the average concentration of total observed data for acetaldehyde was 15.98 ppb and benzene 1.87 ppb, toluene 82.31 ppb, ethyl benzene 63.12 ppb, m+p-xylene 15.66 ppb, oxylene 18.73 ppb, and styrene 4.39 ppb. VOC concentrations in the commercial area were higher than those in the residential area. VOC concentrations of waste gas emitted from sewer lines was also higher than those at the outlet and in the catch basins. It was estimated that the main malodorous VOC among the seven VOCs was acetaldehyde. Conclusions: As there is little data on VOC concentrations inside sewer facilities in Korea, these data will be helpful for estimating impact assessment of VOCs and establishing a counter-plan for the abatement of VOCs from sewer facilities in the future.

Odor Removal Characteristics of Biofilters in Domestic Sewage Treatment Facilities Analyzing Composite Odor and Odor Quotient (복합악취와 악취농도지수 분석을 통한 국내 하수처리시설 바이오필터의 악취제거 특성)

  • Ko, Byung-Churl;Park, Young-Ho;Kim, Dong-Il;Lee, Min-Gyu;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.109-117
    • /
    • 2013
  • The removal characteristics of composite odor and malodorous substances using 33 biofilters in sewage treatment facilities were investigated. The geometry mean values of composite odor and odor quotient were reduced by 52.7% and 59.2% at the outlet of the biofilters, respectively. The removal efficiencies of the biofiltes for the composite odor and odor quotient show a significant difference statistically(p=0.000<0.05). The median value of odor quotient of sulfur compounds was reduced by 69.1% at the outlet of the biofilter and the odor quotient of the sulfur compound at the inlet and outlet of the biofilter shows a significant difference statistically(p=0.000<0.05); on the other hand, those of the $NH_3$ and trimethylamine, aldehydes, VOCs and alcohols, organic acids do not.

Odor Characteristics of Malodorous Sulfur-containing Gas Emitted from a Sewer and Its Outlets (하수관거 및 토구에서 발생하는 유황계 화합물 악취특성)

  • Park, Sang Jin;Kwon, Soo Youl
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.6
    • /
    • pp.477-483
    • /
    • 2014
  • Objectives: This study was carried out to investigate the characteristics of odors emitted from sewage in a sanitary sewer and its outlets. Methods: The concentration of mal-odorous sulfur was analyzed by gas chromatograph, and odor intensity was estimated by an on-site sensory test. Odor intensity calculated from instrumental analysis results was compared with odor intensity observed at field. Results: As a results, the concentration of $H_2S$ ranged from 2.4 ppb to 5,889 ppb (average 703 ppb), while $CH_3SH$, $(CH_3)_2S$, and $(CH_3)_2S_2$ showed from 10 ppb to 554 ppb (average 119 ppb) and from 20 ppb to 332 ppb (average 70 ppb) and from 2.7 ppb to 8.1 ppb (average 5 ppb) individually. Average odor intensity observed in the field was degree three. Odor intensity calculated from sulfur compound concentration was confirmed as similar to the observed odor intensity because the coefficient of variance between the observed and the calculated intensities was less than one. Conclusion: It was expected that the results of this study will be helpful to design a deodorizing device to reduce odor emissions from sewerage facilities in the future.

Adsorption and Removal of Volatile Organic Compounds from Fabrics with β-Cyclodextrin Finish (직물의 β-cyclodextrin 가공에 따른 휘발성 유기성분의 흡착과 제거)

  • Chung, Haewon;Hwang, Nawon;Kim, Joo-Yeon;Shin, Seung-Yeop
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.37 no.1
    • /
    • pp.113-123
    • /
    • 2013
  • Clothes that retain and emanate body odor feel uncomfortable and unclean; subsequently, the adsorption, desorption and removal amounts of malodorous compounds from fabrics with different polarities were examined. 1-Octen-3-one, octanal and isovaleric acid, which are important malodor compounds from the body, were used as volatile organic compounds (VOC). Samples were prepared with unfinished and ${\beta}$-CD finished cotton, nylon and PET fabrics. The amounts of VOCs retained on the fabrics were measured using headspace GC-MS; in addition, the odor intensity of the samples were evaluated by 10 trained panelists. The amounts adsorbed were estimated by weight gain; however, moisture was found to have a larger effect on the increase in weight than VOCs. The polarity of the VOCs decreased in the order of isovaleric acid, octanal and 1-octen-3-one. Despite the exceptionally large amounts of octanal adsorbed on the nylon sample, the amounts of malodorous compounds adsorbed on fabrics increased with the decreasing VOC molecular weight. The unfinished PET sample adsorbed more VOCs than the unfinished-fabric samples. The odor intensity was mostly weaker in the ${\beta}$-CD finished fabrics than in the unfinished fabrics. The odor intensity of the ${\beta}$-CD finished fabrics was lower than unfinished fabrics. The amount of VOCs that remained on the soiled fabric samples after storing in air for 24 hrs decreased with the increasing VOC vapor pressure. Most VOCs were removed by washing; however, more VOCs were left on the ${\beta}$-CD finished fabrics than unfinished fabrics. The intensity of the odor from the unfinished PET and ${\beta}$-CD finished fabrics was stronger and weaker, respectively, than that of other fabrics, even when the same amounts of VOCs remained.

Control of Low-level Malodorous Reduced Sulfur Compound with Visible-light Irradiation

  • Sin, Myeong-Hui;Kim, Jong-Tae;Jang, Jong-Dae;Kim, Mo-Geun;Gwon, Gi-Dong;Lee, Hyeon-Cheol;Jo, Wan-Geun
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.103-106
    • /
    • 2008
  • 악취물질 중 특히 황계열 물질인 Dimethyl sulfide(DMS)을 가시광선 조사아래 실내환경조건에서 광촉매 제거효율을 평가하였다. 농도에 의한 영향에서 1000, 20000$\mu$g/m$^3$에서 램프를 켜자마자 활성이 저하되는 것을 발견하였다. 이는 촉매 산화반응에 의한 부산물의 흡착 때문이다. 습도에 의한 영향평가에서 습도가 낮을 수로 제거율도 떨어졌다. 이는 유기물 산화를 일으키는 라디칼이 물분자에 의해 생성되기 때문에 낮은 습도에서 OH 의 공급원인 물분자의 결핍이 생겨 Dimethyl sulfide(DMS)제거효율을 떨어뜨렸다.

  • PDF

Clinical evaluation of cetylpyridinium chloride-containing mouthwash in halitosis

  • Kang, Minkyung;Kim, Boyeon;Park, Hyounggeun;Lee, Eunseok
    • International Journal of Oral Biology
    • /
    • v.44 no.1
    • /
    • pp.27-29
    • /
    • 2019
  • Halitosis is a very common disease that affects the majority of the population and is characterized by unpleasant odor during expiration. Anaerobic bacteria produce a range of malodorous substances including volatile sulfur compounds. To reduce oral malodor, the amount of oral microorganisms should be managed through brushing, scraping, and use of antibacterial agents. In this study, a mouthwash containing 0.05% cetylpyridinium chloride was tested on 22 candidates with oral malodor for two weeks to confirm oral malodor reduction through the use of antibacterial mouthwashes. Volatile sulfur compound measurements were significantly lower after using the mouthwash than before using it; thus, the mouthwash effectively reduced oral malodor.

Investigation of the Condition of the Operation of the Livestock Liquid Manure Bin and Assessment of Malodorant Emissions (축분뇨 액비 저장조의 운영실태 및 악취 물질 발생량 조사)

  • Kim T. I.;Song J. I.;Joung S.;Jeong J. W.;Chung E. S.;Barroga A. J.;Yoo Y. H.;Yang C. B.;Kim M. K.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.189-196
    • /
    • 2005
  • This study was carried out to determine the acceptability of liquid manure bin among livestock farmers and agricultural farmers, and quantify its malodorous compounds. The results were as follows; 1. The size of the manure bins owned by $93\%$ of 60 farmers surveyed was 200 M/T and were all in normal operation. Around $57\%$ of the normally operated bins were processed under aerobic condition. 2. Filly percent of the respondents utilized their liquid manure bin twice a year while $64\%$ used commercial microbial products to enhance maturity of their liquid manure and abatement of malodorous emissions. On the other hand, $43\%$ mentioned problems on the labor requirement, mechanical maintenance and lending cost of liquid manure processing and utilization, and the price of the commercial microbial products. 3. Malodorants emitted from livestock liquid manure bins and their boundary bin depended upon the livestock liquid manure processing condition. Within bin under the aerobic processing condition, Iso-valeric and propionic acid were ranged 0.012 to 0.07ppm and 0.17 to 2.85ppm, respectively. Within bin under the anoxic processing condition, n-butyric, n-valeric acid, and acetaldehyde were ranged 1.5 to 2.3ppm, 1.3 to 1.8ppm, and 0.8 to 2.1ppm, respectively. Malodorants emitted from the boundary of livestock liquid manure bins under the anoxic processing condition were detected the range of 0.4 to 0.9 ppm, more than the concentration of law regulation, as an acetaldehyde, but under the aerobic processing condition, they did not any detection.

  • PDF

Effect of Biofilter on Reducing Malodor Emission (악취 발산감소를 위한 필터의 이용 효과)

  • 김원영;정광화;노진식;김원호;전병수;류호현;전영륜
    • Journal of Animal Environmental Science
    • /
    • v.4 no.2
    • /
    • pp.161-166
    • /
    • 1998
  • Controlling malodor originating from livestock feces has become a major issue, due to its influence on the health of man and livestock, together with its influences on atmospheric pollution. In this study, Five types of biofilters filled with saw-dust, night soil, fermented compost, leaf mold and a mixture(a compound of night soil, fermented compost and leaf mold at the same rates, respectively) were manufactured and tested. To study the effect of the biofilter on reducing malodor in a composting facility and swine building, a pilot scale composting facility enclosed with polyethylene film was constructed. Swine feces was composted in the facility and malodorous gas generated from the decomposition of organic matter in the feces was gathered by vacuum pump. Each biofilter achieved 87∼96% NH3 removal efficiency. This performance was maintained throughout 10 days of operation. The highest NH3 removal efficiency was achieved by leaf mold on the first day of operation period. It reduced the concentration of NH3 by about 96%. Night soil and fermented compost showed nearly equal performance of 93 to 94% for 10 days from the beginning of operation. The mixture achieved the lowest NH3 removal efficiency. It reduced NH3 concentration by about 89∼94% for 10 days from the beginning of operation. However NH3 removal efficiency of each biofilter declined with the passage of operational time. After 30 days from the beginning of operation, NH3 removal efficiency of each biofilter of each biofilter was below 60%, respectively. The concentration of H2S and CH3-SH originating from compost were equal to or less than 5mg/l and 3mg/l, respectively. After passing throughout the biofilter, the concentration of H2S and CH3-SH were not detected.

  • PDF

Application of Non-Thermal Plasma for the Simultaneous Removal of Odor and Sludge (무기악취와 슬러지 동시처리를 위한 저온플라즈마의 적용)

  • Hwang, Hyun-Jung;Ann, Hae-Young;Shin, Seung-Kyu;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.85-92
    • /
    • 2010
  • In this study, odorous compounds emitted from various wastewater treatment were treated with using the non-thermal plasma reaction, and the effluent gas from the plasma reactor was introduced to a waste sludge reactor to achieve simultaneous sludge reduction. Hydrogen sulfide, the model odorous compound, was removed at 70% using the plasma reaction, and greater than 99% removal efficiency was observed when treated by the sludge reactor. In addition, the sludge reactor showed a high efficiency of ozone removal. As ozone reacted with sludge, oxidation with organic matters took place, and total COD decreased by 50~60% and soluble COD increased gradually. As a result, the integrated process consisting of the non-thermal plasma and the sludge reactor can be successfully applied for the simultaneous treatment of malodorous gas and waste sludge.

Studies of gas chromatographic analysis of malodorous S compounds in air (대기 중 악취황 성분들에 대한 GC 분석의 특성)

  • Kim, Ki-Hyun;Oh, Sang In;Choi, Y.J.
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.145-152
    • /
    • 2004
  • In this study, analytical characteristics of S gas detection technique were investigated against four major reduced S compounds (including hydrogen sulfide; methyl mercaptan; dimethyl sulfide (DMS); and dimethyl disulfide (DMDS)). To analyze such properties, an analytical system was constructed by combining the GC/PFPD system with the loop injection method. The results of our analysis indicated that response behavior of S gases differs greatly between compounds; H2S exhibited the weakest sensitivity of all compounds, while DMDS with two S-atom compounds the strongest sensitivity. To learn more about their response behavior on GC/PFPD method, their calibration patterns were compared using the three arbitrarily set concentration ranges of low, intermediate, and high. The results showed that calibration patterns of each compound are distinguished because of different factors. There was a line of evidence that calibration of $H_2S$ was affected noticeably by adsorptive loss within the system, whereas those of DMS and DMDS were influenced most sensitively by such factor as the linearity response at a given PMT voltage setting. The overall results of our study suggest that quantification of malordorous S compounds require a better knowledge of compound-specific response behavior against GC detection.