• Title/Summary/Keyword: Male Image

Search Result 756, Processing Time 0.024 seconds

Geometry of Resident's ridge with Multidetector-Row Computed Tomograph Image (다중검출기 컴퓨터 단층 영상 분석을 이용한 Resident's ridge의 형태학적 연구)

  • Roh, Jeong-Ho;Min, Byoung-Hyun;Park, Jeong-Wook;Ahn, Byung-Moon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.40-44
    • /
    • 2008
  • Purpose: The purpose of this study was to report the real geometry of Resident's ridge doing in anterior cruciate ligament reconstruction Materials and Methods: From Jan 2007 to Aug 2007, 48 cases which had normal distal femoral condyle analyzed with Multidetector-Row Computed Tomography. Resident's ridge was defined as change of height above 1 mm in lateral wall of intercondylar notch. Anterior-posterior length of intercondylar notch, length and height of Resident's ridge, distance of Resident's ridge from posterior cortex were estimated with 3-D reconstruction using $Lucion^{(R)}$ program. Results: Cases were $59{\pm}16$ years olds and male was 16 cases, female was 32 cases. 9 cases had no Resident's ridge, anterior-posterior length of intercondylar notch was $25.4{\pm}3.5$ mm, average of length and height of the Resident's ridge was $8.2{\pm}2.6,\;3.5{\pm}1.5$ mm. Distance of the Resident's ridge from posterior cortex was $7.6{\pm}2.6$ mm. Conclusion: Resident's ridge was used as landmark in anterior cruciate ligament reconstruction, which presented in many cases and which had distinct length and height.

  • PDF

The Comparative Study of Alveolar Bone Level and Root Form of the Mandibular Molar on Radiographic Image and Clinical Examination (방사선사진과 임상검사에서 하악 대구치 치근의 형태학적 구조 및 치조골 수준에 관한 비교연구)

  • Park, Jung-Bae;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.2
    • /
    • pp.281-292
    • /
    • 2004
  • Periodontal defects of the furcation are characterized by several inherent anatomic factors that can make successful periodontal therapy difficult and results unpredictable. The severity and rate of occurrence of periodontal disease are directly related to the location of the furcation relative to the cementa-enamel junction and anatomical form of the root by limiting the accessibility and effectiveness of the periodontal instrumentation. This study investigated the reliability and accuracy of panoramic radiograph diagnoses of the periodontal state of mandibular molars, particularly regarding the diagnosis of furcation area periodontal defects, treatment planning, and prognosis prediction. This study examined a total of 110 teeth belonging to 33 subjects (19 male, 14 female) presenting with incipient to moderate periodontitis 4-7mmpocket depth. The alveolar bone level, length and width of the root trunk, and root separation angle were measured using the panoramic radiograph and compared to the results taken directly by retracting a full-thickness flap. The results of the study are as follows: 1. Data regarding the alveolar bone level of the mandibular first molar showed that the directly taken surgical measurements resulted in $5.1{\pm}0.9mm$ that was slightly deeper than the corresponding panoramic measurement resulted in $4.8{\pm}0.8mm$, but these differences were statistically insignificant (p>0.05). 2. The data of the directly taken surgical measurement of the mandibular second molar $(5.1{\pm}1.1mm)$ was slightly deeper than the corresponding panoramic measurement $(4.7{\pm}1.2mm)$, but these differences were statistically insignificant (p>0.05). 3. The measured values of the length and width of the mandibular first molar root trunks were determined to be $4.1{\pm}0.6mm$ and $7.3{\pm}0.9mm$, respectively, while the values of the mandibular second molar root trunks were determined to be $4.6{\pm}1.3mm$ and $7.6{\pm}0.9mm$ respectively. The differences between these values were found to be statistically significant (p<0.01). 4. The measured values of the root separation angle showed that the mandibular first molars averaged $34.5{\pm}4.4^{\circ}$, while the mandibular second molars averaged $23.0{\pm}10.0^{\circ}$. The differences between these values were found to be statistically significant (p<0.01).

Cultural Politics of Gendered Schadenfreude Surrounding an Idol Focusing on the debate over IU (아이돌을 둘러싼 젠더화된 샤덴프로이데(Schadenfreude)의 문화정치학 <아이유 사태>를 중심으로)

  • Kim, Hyun Gyung
    • Korean journal of communication and information
    • /
    • v.80
    • /
    • pp.115-142
    • /
    • 2016
  • This study aims to reveal the content of and logic behind a recent negative public sentiment toward female idols with the example of a debate over songstress IU's fourth album that was released late last year. While previous studies on fandom have focused on the identification process towards entertainers and making community, a recent phenomenon of "anti-fandom" or "malicious comments" implies that more research is needed on negative emotions such as hostility or schadenfreude (feelings of pleasure from others' misfortunes). Schadenfreude is a social sentiment that originated in modern liberalism, which features contradictions between public equality and private ownership, and that has been intensified in neoliberalism, which features a maximization of this contradiction centering on a meritocracy. Celebrities in Korea often become the targets of schadenfreude, which is associated with the suspicion that they gain popularity not from their abilities but from "just being popular." It should also be noted that this kind of schadenfreude operates differently between male and female entertainers. Specifically, the acquisition of money and fame by modern women whose presence used to be located in the private possessions of males is considered to be due to their unjustified use of sexuality. This is also the background of the recent online misogyny culture in Korea. In this context, IU, who had been successful at building a differentiated image of "sister-like idol artist," became a valid target. Although accusing IU of utilizing pedophilia reflects a stalemate that a current politics of sexual violence faces, it rather damages the name of an individual than attracts public attention to the structural causes of childsexualabuse. This is why I see the way that pedophilia was used in the debate over IU as a schadenfreude. Consequently, the term pedophilia here contributes to an expansion of the entertainment economy that is sustained by rises and falls of the celebrities' stock prices.

  • PDF

Development of Two-Dimensional Scanning Videokymography for Analysis of Vocal Fold Vibration

  • Wang, Soo-Geun;Lee, Byung-Joo;Lee, Jin-Choon;Lim, Yun-Sung;Park, Young Min;Park, Hee-June;Roh, Jung-Hoon;Jeon, Gye-Rok;Kwon, Soon-Bok;Shin, Bum-Joo
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.24 no.2
    • /
    • pp.107-111
    • /
    • 2013
  • Objectives : We developed two-dimensional (2D) scanning videokyomography to evaluate the mucosal wave of whole vocal cords in real time to overcome the limit of preexisting stroboscopy and line scanning videokymography which could not evaluate it. Methods : We implemented a continuous light source with high brightness, a high-definition CMOS camera, and capture board for saving the data. We created the software program to analyze the image data from the system. The test of the functionality of the 2D scanning videokymography camera was performed in one of the authors (P.H.J 32 years old male). Vocal cord images were obtained during normal phonation and falsetto phonation. Images were obtained also during cough, diplophonia. Results : The system made it possible to measure objective parameters, including fundamental frequency, amplitude, regularity, mucosal wave, and phase difference, medial and lateral peak, opening versus closing duration related to vocal fold vibration. Simultaneously, it enabled analysis of the whole mucosal wave of the entire vocal fold in real time. 2D scanning videokymography was also effective for evaluating the dynamic status of the vocal fold when the subject phonated aperiodic voice. Conclusion : In conclusion, 2D scanning videokymography can support the analysis of the whole mucosal wave of the entire vocal cord with objective vocal parameters, overcoming the limitations of stroboscopy and previous line scanning videokymography techniques.

  • PDF

Arthroscopic Posterior Capsular Shaft for Traumatic Recurrent Unidirectional Posterior Subluxation of the Shoulder (외상으로 인한 재발성 단방향 견관절 후방 아탈구의 관절경을 이용한 후방낭 이동술)

  • Kim, Seung-Ho;Ha, Kwon-Ick;Yoo, Jae-Chul;Lee, Yong-Seuk;Lee, Hui-Dong
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.55-66
    • /
    • 2003
  • Background: The purpose of this study was to evaluated results of arthroscopic treatment of the traumatic recurrent unidirectional posterior subluxation. Materials and Methods: We treated twenty-seven patients who had traumatic recurrent unidirectional posterior subluxation of the shoulder by arthroscopic labral repair and posterior capsular shift and prospectively evaluated for a mean of thirty-nine months (range,24 to 85 months). Patients who had posteroinferior instability, multidirectional instability, atraumatic onset, or revision cases were excluded. There were twenty-five male and two female patients with the mean age of twenty-one years (range, 14 to 33 years). All patients were involved in sports activity. All had a significant traumatic event prior to the onset of the instability. Stability, motion, three objective measurement (UCLA, ASES, and Rowe scores) and two subjective measurements (pain and function visual analogue scale) were evaluated. Results: The most common finding in magnetic resonance image-arthrogram was separation of the posteroinferior labrum without displacement in 9 patients, In arthroscopic examination, all patients had one or more lesions in the posterior inferior labrum and capsule. The most common finding was incomplete stripping of the posterior inferior labrum (18 patients). The posteroinferior capsule subjectively appeared to be stretched in twenty-two patients. At follow-up, all patients had improved shoulder function and scores(p < 0.01). All patients had stable shoulder by subjectivel and objectivel measurements, except one patient who had recurrent subluxation. All but one patient with postoperative recurrence were able to return to their prior sports activity with little or no limitation. Twenty-four patients were graded as having more than 90% of shoulder function. Their were twenty-one excellent, five good, and one fair UCLA. scores. Pain sore improved from 4.5 to 0.2 point(p : 0.0001). Mean loss internal rotation was one vertebral level. None had operative complications. Conclusion: In conclusion, treatment outcomes of the traumatic unidirectional recurrent posterior subluxation are consistently reliable with respect to the stability, pain relief, and functional restoration by the arthroscopic posterior capsular shift procedure.

Acceleration of Wound Healing and Collagen Deposition in Rat Skin by High Voltage Pulsed Current Stimulation (고전압맥동전류자극이 흰쥐 피부 창상치유와 교원질 축적에 미치는 효과)

  • Lee Jae-hyoung;Song In-young;Kim Jong-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.1-12
    • /
    • 2003
  • The purpose of this study was to investigate the effect of high voltage pulsed current stimulation (HVPCS) on the healing rate of a dermal wound in a rat. We also determined the mechanism of promoting healing by HVPCS. Twenty male Sprague-Dawley rats were randomly divided into two group; HVPCS group (n=10) and control group (n=10). The HVPCS rats received electrical stimulation with a current intensity of 50 V at 100 pps for a duration of 30 minutes, while the control group was given the same treatment without electricity for a week. The biopsy specimens were fixed in formalin, embedded in paraffin and stained with Masson's trichrome, hematoxylin and eosin (H&E). The fibroblasts and collagen density were counted using a light microscope and computerized image analysis system and calculated as the density and the percent. A Student t-test showed a significantly higher wound healing rate of the HVPCS group than control (t=-4.161, p<0.001). The fibroblasts in the HVPCS group were higher than in the control group (t=-4.921, p<0.001). The density of collagen in the HVPCS group was also higher than in the control group (t=-4.367, p<0.001). These results indicate that the HVPCS accelerated the rate of healing in dermal wound, and increased fibroblasts and collagen density in the regenerative dermis. These findings suggest that the HVPCS may activate fibroblasts by alteration of the electrical environment, and it may increase collagen synthesis in the regenerative dermal wound.

  • PDF

The incidence and configuration of the bifid mandibular canal in Koreans by using cone-beam computed tomography

  • Kang, Ju-Han;Lee, Kook-Sun;Oh, Min-Gyu;Choi, Hwa-Young;Lee, Sae-Rom;Oh, Song-Hee;Choi, Yoon-Joo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.53-60
    • /
    • 2014
  • Purpose: This study was performed to investigate the incidence and configuration of the bifid mandibular canal in a Korean population by using cone-beam computed tomography (CBCT) imaging. Materials and Methods: CBCT images of 1933 patients (884 male and 1049 female) were evaluated using PSR-9000N and Alphard-Vega 3030 Dental CT units (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan). Image analysis was performed by using OnDemand3D software (CyberMed Inc., Seoul, Korea). The bifid mandibular canal was identified and classified into four types, namely, the forward canal, buccolingual canal, dental canal, and retromolar canal. Statistical analysis was performed by using the chi-squared test and one-way analysis of variance (ANOVA). Results: Bifid mandibular canals were observed in 198 (10.2%) of 1933 patients. The most frequently observed type of bifid mandibular canal was the retromolar canal (n=104, rate: 52.5%) without any significant difference among the incidence of each age and gender. The mean diameter of the accessory canal was 1.27 mm (range: 0.27-3.29 mm) without any significant difference among the mean diameter of each type of the bifid mandibular canal. The mean length of the bifid mandibular canals was 14.97mm(range: 2.17-38.8 mm) with only a significant difference between the dental canal and the other types. Conclusion: The bifid mandibular canal is not uncommon in Koreans and has a prevalence of 10.2% as indicated in the present study. It is suggested that a CBCT examination be recommended for detecting a bifid canal.

A Space Skew and Crosstalk Cancellation Scheme Based on Indoor Spacial Information Using Self-Generating Sounds (자체발성음을 이용한 실내공간정보 획득 및 공간뒤틀림/상호간섭 제거기법)

  • Kim, Yeong-Moon;Yoo, Seung-Soo;Lee, Ki-Seung;Kim, Sun-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2C
    • /
    • pp.246-253
    • /
    • 2010
  • In this paper, a method of removing the space skew and cross-talk cancellation is proposed where the self-generated signals from the subject are used to obtain the subject's location. In the proposed method, the good spatial sound image is maintained even when the listener moves from the sweet spot. Two major parts of the proposed method are as follows: listener position tracking using the stimuli from the subject and removal of the space skew and cross-talk signals. Listener position tracking is achieved by estimation of the time difference of arrival (TDoA). The position of the listener is then computed using the Talyer-series estimation method. The head-related transfer functions (HRTF) are used to remove the space skew and cross-talk signals, where the direction of the HRTF is given by the one estimated from the listener position tracking. The performance evaluation is carried out on the signals from the 100 subjects that are composed of the 50 female and 50 male subjects. The positioning accuracy is achieved by 70%~90%, under the condition that the mean squared positioning error is less than $0.07m^2$. The subjective listening test is also conducted where the 27 out of the 30 subjects are participated. According to the results, 70% of the subjects indicates that the overall quality of the reproduced sound from the proposed method are improved, regardless of the subject's position.

Risk Factors Analysis of Alcoholic Liver Diseases by Ultrasonography (초음파검사에 의한 알코올성 간질환의 위험요인 분석)

  • Lee, Man-Koo;Han, Nam-Sook;Lim, Cheong-Hwan;Jung, Hong-Ryang;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.185-194
    • /
    • 2009
  • This research attempted to find risk factors of alcoholic liver diseases by ultrasonography at the K image medicine clinic center located in Kwangju city, Kyunggi-Do from March to May, 2007. Six risk factors were selected for this study, age, sex, frequency of alcohol drinking, body mass index(BMI), cholesterol and GPT. The data collected from 353 patients of aged between 20 and 69. This study found the relationships between liver diseases and alcohol drinking style by liver ultrasonography. The results of the analyses showed that the male were 2.12 times more likely to have liver diseases than the female. The persons drinking alcohol more than 3 times per week had 2.37 times higher likelihood of showing liver diseases than below 2 times per week or non drinking at all.. The persons with normal body mass index have 0.52 times lower probability of liver diseases than the persons with abnormal BMI. The persons with abnormal cholesterol level have 9.13 times higher probability of liver diseases. The persons with abnormal GPT have 4.66 times higher probability of liver diseases. The results of this study suggested applying ultrasonography in health promotion programs for diagnosis of liver diseases.

Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies (강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상)

  • Jeong Soon-wuk;Park Hee-myung;Han Sook-hee;Yoon Jung-hee;Han Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF