• 제목/요약/키워드: Makoto

검색결과 340건 처리시간 0.026초

Conservation of Satoyama Landscapes for the Restoration of Ecological Integrity of Urban Area in Japan

  • Yokohari, Makoto;Kurita, Hideharu;Amati, Marco
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • 제1호
    • /
    • pp.43-52
    • /
    • 2001
  • One of the major environmental issues Japanese cities is now facing with is the conservation of seminatural landscapes for the restoration of ecological integrity of urban areas. The satoyama landscape, which includes coppice woodlands, agricultural areas and rural settlements, is seen as an indispensable semi-natural landscape, formed as a result of man-nature interaction. However, because of the loss of the economic viability they are now abandoned and in the process of losing their ecological values. Today a number of local municipalities as well as NPO groups are involved in the conservation projects of these landscapes. Although satoyama landscapes are commonly believed to have maintained their character over the years, historical studies have revealed that these landscapes have experienced constant and dynamic changes due to a variation in human impacts. It is therefore understood that the conservation projects on satoyama landscapes should not intend to restore their past condition, but should wet the goal of maintaining their dynamic character by promoting ecological roles which the landscapes may play in the contemporary world. EXPO2005 project in Aichi Prefecture is a good example of a development project underway on satoyama landscapes which intend to conserve the landscapes by stimulating contemporary ecological for them. In EXPO2005 project the key issue was the conservation of semi-natural landscapes formed by constant and intensive human impacts over the centuries and thus allowing endemic and endangered species to be accommodated. The planning team proposed a scheme to restore economic viability of satoyama landscapes. The scheme involves re-introducing intensive human impacts through a new management system with an innovative technology. This may restore the economic viability of lumbers provided form satoyama woodlands. EXPO2005 is understood as a model case which stimulates contemporary ecological functions of satoyama landscapes by applying innovative planning concepts.

  • PDF

녹(鹿)의 혈청단백(血淸蛋白)에 관한 연구(硏究) (Studies on the Blood Protein Polymorphisms of Deer: Cervus nippon, Cervus unicolor)

  • 임영재;송영의;스즈키 쇼조;타나카 카즈;아마노 타카시;쿠로사와 야츠;카츠마타 마코토
    • 대한수의학회지
    • /
    • 제25권1호
    • /
    • pp.19-25
    • /
    • 1985
  • 한국(韓國), 대만(臺灣), 일본(日本)에서 사육(飼育)하고 있는 꽃사슴(Cervus nippon) 129두(頭)와 물사슴(Cervus unicolor) 7두(頭)에서 hemoglobin, transferrin, albumin carbonic anhydrase, slow-${\alpha}_2$ 및 amylase형(型)을 전기영동(電氣泳動)에 의(依)하여 분석(分析)한 결과(結果) 다음과 같은 결론(結論)을 얻었다. 1. cellulose acetate에 의(依)한 전기영동(電氣泳動)이 starch gel에 의(依)한 전기영동(電氣泳動)보다 hemoglobin형(型) 분리(分離)에 있어서 더 간편하며 시간이 적게 걸리고, 선명(鮮明)할 뿐만 아니라 영구보존(永久保存)이 가능(可能)하다. 2. 꽃사슴의 hemoglobin형(型)은 $Hb^F$, $Hb^{FS}$, $Hb^S$형(型)으로 분리(分離)되었으나 물사슴에 있어서는 전부(全部) $Hb^F$형(型)으로 나타났다. 3. hemoglobin ${\beta}$ chain은 4가지형(型) 즉 ${\beta}$-1, ${\beta}$-2, ${\beta}$-3 및 ${\beta}$-4로 분리(分離)되었다. 4. hemoglobin ${\alpha}$ chain은 ${\alpha}_1$${\alpha}_1{\alpha}_2$형(型)으로 분리(分離)되었다. 5. slow-${\alpha}_2$형(型)은 A형(型)과 AB형(型)으로 분리(分離)되었으며, 꽃사슴에 있어서는 AB형(型)이 12% 출현(出現)하였으나 물사슴에서는 전부(全部) A형(型)으로 AB형(型)은 없었다. 6. albumin형(型)에서는 F형(型)과 S형(型)으로 분리(分離)되었으며 꽃사슴은 전부(全部) F형(型)이였고, 물사슴은 전부(全部) S형(型)이였다. 7. transferrin형(型), carbonic anhydrase형(型) 및 amylase형(型)은 전부(全部) 각각(各各) 1종류(種類)의 형(型)이였다.

  • PDF

Parametric study of porous media as substitutes for flow-diverter stent

  • Ohta, Makoto;Anzai, Hitomi;Miura, Yukihisa;Nakayama, Toshio
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제2권2호
    • /
    • pp.111-125
    • /
    • 2015
  • For engineers, generating a mesh in porous media (PMs) sometimes represents a smaller computational load than generating realistic stent geometries with computer fluid dynamics (CFD). For this reason, PMs have recently become attractive to mimic flow-diverter stents (FDs), which are used to treat intracranial aneurysms. PMs function by introducing a hydraulic resistance using Darcy's law; therefore, the pressure drop may be computed by test sections parallel and perpendicular to the main flow direction. However, in previous studies, the pressure drop parallel to the flow may have depended on the width of the gap between the stent and the wall of the test section. Furthermore, the influence of parameters such as the test section geometry and the distance over which the pressure drops was not clear. Given these problems, computing the pressure drop parallel to the flow becomes extremely difficult. The aim of the present study is to resolve this lack of information for stent modeling using PM and to compute the pressure drop using several methods to estimate the influence of the relevant parameters. To determine the pressure drop as a function of distance, an FD was placed parallel and perpendicular to the flow in test sections with rectangular geometries. The inclined angle method was employed to extrapolate the flow patterns in the parallel direction. A similar approach was applied with a cylindrical geometry to estimate loss due to pipe friction. Additionally, the pressure drops were computed by using CFD. To determine if the balance of pressure drops (parallel vs perpendicular) affects flow patterns, we calculated the flow patterns for an ideal aneurysm using PMs with various ratios of parallel pressure drop to perpendicular pressure drop. The results show that pressure drop in the parallel direction depends on test section. The PM thickness and the ratio of parallel permeability to perpendicular permeability affect the flow pattern in an ideal aneurysm. Based on the permeability ratio and the flow patterns, the pressure drop in the parallel direction can be determined.

Turning on the Left Side Electrode Changed Depressive State to Manic State in a Parkinson's Disease Patient Who Received Bilateral Subthalamic Nucleus Deep Brain Stimulation: A Case Report

  • Kinoshita, Makoto;Nakataki, Masahito;Morigaki, Ryoma;Sumitani, Satsuki;Goto, Satoshi;Kaji, Ryuji;Ohmori, Tetsuro
    • Clinical Psychopharmacology and Neuroscience
    • /
    • 제16권4호
    • /
    • pp.494-496
    • /
    • 2018
  • No previous reports have described a case in which deep brain stimulation elicited an acute mood swing from a depressive to manic state simply by switching one side of the bilateral deep brain stimulation electrode on and off. The patient was a 68-year-old woman with a 10-year history of Parkinson's disease. She underwent bilateral subthalamic deep brain stimulation surgery. After undergoing surgery, the patient exhibited hyperthymia. She was scheduled for admission. On the first day of admission, it was clear that resting tremors in the right limbs had relapsed and her hyperthymia had reverted to depression. It was discovered that the left-side electrode of the deep brain stimulation device was found to be accidentally turned off. As soon as the electrode was turned on, motor impairment improved and her mood switched from depression to mania. The authors speculate that the lateral balance of stimulation plays an important role in mood regulation. The current report provides an intriguing insight into possible mechanisms of mood swing in mood disorders.

유기 박막 트랜지스터를 이용한 유연한 디스플레이의 게이트 드라이버용 로직 게이트 구현 (Implementation of Logic Gates Using Organic Thin Film Transistor for Gate Driver of Flexible Organic Light-Emitting Diode Displays)

  • 조승일;미즈카미 마코토
    • 한국전자통신학회논문지
    • /
    • 제14권1호
    • /
    • pp.87-96
    • /
    • 2019
  • 유기 박막 트랜지스터 (OTFT) 백플레인을 이용한 유연한 유기 발광 다이오드 (OLED) 디스플레이가 연구되고 있다. OLED 디스플레이의 구동을 위해서 게이트 드라이버가 필요하다. 저온, 저비용 및 대 면적 인쇄 프로세스를 사용하는 디스플레이 패널의 내장형 게이트 드라이버는 제조비용을 줄이고 모듈 구조를 단순화한다. 이 논문에서는 유연한 OLED 디스플레이 패널의 내장형 게이트 드라이버 제작을 위하여 OTFT를 사용한 의사 CMOS (pseudo complementary metal oxide semiconductor) 로직 게이트를 구현한다. 잉크젯 인쇄형 OTFT 및 디스플레이와 동일한 프로세스를 사용하여 유연한 플라스틱 기판 상에 의사 CMOS 로직 게이트가 설계 및 제작되며, 논리 게이트의 동작은 측정 실험에 의해 확인된다. 최대 1 kHz의 입력 신호 주파수에서 의사 CMOS 인버터의 동작 결과를 통하여 내장형 게이트 드라이버의 구현 가능성을 확인하였다.

Polarimetry of Three Asteroids in Comet-Like Orbits (ACOs)

  • Geem, Jooyeon;Ishiguro, Masateru;Bach, Yoonsoo P.;Kuroda, Daisuke;Naito, Hiroyuki;Hanayama, Hidekazu;Kim, Yoonyoung;Kwon, Yuna G.;Jin, Sunho;Sekiguchi, Tomohiko;Okazaki, Ryo;Vaubaillon, Jeremie J.;Imai, Masataka;Ono, Tatsuharu;Futamuts, Yuki;Takagi, Seiko;Sato, Mitsuteru;Kuramoto, Kiyoshi;Watanabe, Makoto
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.65-65
    • /
    • 2019
  • Near-Earth objects consist of a mixture of bodies originated from outer solar system and main asteroidal belt, which are recognized as comets and near-Earth asteroids. In principal, they have orbits distinguishable by their orbital elements. It is, however, that some comets are recognized as asteroids because they could have lost the most of volatile materials in their subsurface layers. Due to their asteroidal appearances, it has been challenging to discriminate such dormant comets from a list of known asteroids. Here we propose to utilize polarimetric technique for finding such dormant comets. We thus conducted a polarimetric observations of three candidates of dormant comet nuclei, (331471) 1984 QY1, (3552) Don Quixote and (944) Hidalgo, by using the 1.6-m Pirka Telescope at the Nayoro observatory (operated by Hokkaido University, Japan). We selected these asteroids in comet-like orbits (ACOs) based on the orbital elements (i.e., the Tisserand parameter with respect to Jupiter TJ < 3). We found that 1984 QY1 has a polarimetric albedo (geometric albedo determined via polarimetry) pV = 0.16 +/- 0.06 while both Don Quixote and Hidalgo have Rc-band polarimetric albedos pR < 0.05. In accordance with the polarimetric result together with a dynamical analysis, we surmised that 1984 QY1 could be an S-type asteroid evolved into the current orbit via 3:1 mean motion resonance with Jupiter. On the contrary, the previous spectroscopic studies indicated that Don Quixote and Hidalgo are classified into D-type taxonomic group, which are typical of comet nuclei. In this presentation, we will introduce our polarimetric observations of ACOs and emphasize that polarimetry is powerful for discriminating the asteroidal and cometary origins.

  • PDF

딥러닝을 통한 STIV(영상유속계)의 정밀도 및 적용성 향상에 관한 연구 (Study on the improvement of precision and application of STIV using deep learning)

  • 정재훈;김연중;하세가와 마코토;윤종성
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.78-78
    • /
    • 2021
  • 영상유속분석법은 비접촉식으로 유속을 측정하는 방법으로 특히 홍수시 하천의 표면유속을 안전하게 계측할 수 있어서 경제적이고 안전한 하천유속 측정 방법 중 하나이다. STIV는 영상의 휘도 정보를 시간 방향으로 나열하여 작성된 STI(Space-Time Image)에 나타나는 패턴의 기울기를 이용하여 유속을 산정하는 방법이다. 특히 STIV(Space-Time Image Velocimetry)는 기존 입자군의 상호상관법에 기초한 입자영상유속계와 달리 표식자의 유무와 상관없이 유속을 측정할 수 있어 적용성과 안정성이 확보된다. 하지만 영상의 상태가 불량한 경우 정확한 유속 측정이 난해하며 야간에는 별도의 조명 추가 및 태풍과 같은 악기상에서는 빗방울이 카메라에 맺히거나 수면의 진동, 구조물의 진동에 의한 영상의 상태가 불량하게 되어 측정 정도가 떨어진다. 이처럼 영상을 이용한 유속 계측에 있어 다양한 연구 및 기술개발이 요구되는 시점이다. 따라서 본 연구에서는 영상을 이용한 정확한 유속측정을 위해 STIV와 인공지능을 융합하여 정확한 유속 평가를 목적으로 한다. 우선 기존 STI에 의한 기울기 추정방법을 확장하여 딥러닝(CNN)에 의한 기울기 추정방법을 도입하였다. CNN은 일반적으로 이미지의 특성을 추출하는데 유용한 방법으로서 STI의 2차원 Fourier변환 이미지를 사용하여 패턴의 기울기를 감지하도록 학습하였고 적용 결과 기울기에 대한 인식율은 매우 양호하였으며 이를 이용한 실제 관측 영상에 적용한 결과 유속에 대한 정밀도도 매우 양호하게 나타났다. 또한 딥러닝을 적용한 STIV는 노이즈(진동, 화면 불량 등)가 있는 영상에서도 안정적으로 유속을 산정할 수 있으며 전파유속계를 이용한 실제 하천의 표면유속 관측치와 비교 검토 결과 매우 양호하게 유속을 평가하고 있는 것으로 나타났다.

  • PDF

Impact of COVID-19 Infection on Work Functioning in Japanese Workers: A Prospective Cohort Study

  • Makoto Okawara;Keiki Hirashima;Yu Igarashi ;Kosuke Mafune ;Keiji Muramatsu ;Tomohisa Nagata ;Mayumi Tsuji ;Akira Ogami ;Yoshihisa Fujino
    • Safety and Health at Work
    • /
    • 제14권4호
    • /
    • pp.445-450
    • /
    • 2023
  • Background: The impact of COVID-19 infection on workers' work function persists even after the acute phase of the infection. We studied this phenomenon in Japanese workers. Methods: We conducted a one-year prospective cohort study online, starting with a baseline survey in December 2020. We tracked workers without baseline work functioning impairment and incorporated data from 14,421 eligible individuals into the analysis. We estimated the incidence rate ratio for new onset of work functioning impairment due to COVID-19 infection during follow-up, using mixed-effects Poisson regression analysis with robust variance. Results: Participants reporting infection between January and December 2021 showed a significantly higher incidence of new work functioning impairment (adjusted incidence rate ratio: 2.18, 95% confidence interval: 1.75-2.71, p < 0.001). The formality of the recuperation environment correlated with a higher risk of work functioning deterioration in infected individuals (p for trend <0.001). Conclusion: COVID-19-infected workers may continue to experience work difficulties due to persistent, post-acute infection symptoms. Companies and society must urgently provide rehabilitation and social support for people with persistent symptoms, recognizing that COVID-19 is not just a transient acute infection.

Modified Urethral Graciloplasty Cross-Innervated by the Pudendal Nerve for Postprostatectomy Urinary Incontinence: Cadaveric Simulation Surgery and a Clinical Case Report

  • Hisashi Sakuma;Masaki Yazawa;Makoto Hikosaka;Yumiko Uchikawa-Tani;Masayoshi Takayama;Kazuo Kishi
    • Archives of Plastic Surgery
    • /
    • 제50권6호
    • /
    • pp.578-585
    • /
    • 2023
  • An artificial sphincter implanted in the bulbous urethra to treat severe postprostatectomy urinary incontinence is effective, but embedding-associated complications can occur. We assessed the feasibility, efficacy, and safety of urethral graciloplasty cross-innervated by the pudendal nerve. A simulation surgery on three male fresh cadavers was performed. Both ends of the gracilis muscle were isolated only on its vascular pedicle with proximal end of the obturator nerve severed and transferred to the perineum. We examined whether the gracilis muscle could be wrapped around the bulbous urethra and whether the obturator nerve was long enough to suture with the pudendal nerve. In addition, surgery was performed on a 71-year-old male patient with severe urinary incontinence. The postoperative 12-month outcomes were assessed using a 24-hour pad test and urodynamic study. In all cadaveric simulations, the gracilis muscles could be wrapped around the bulbous urethra in a γ-loop configuration. The length of the obturator nerve was sufficient for neurorrhaphy with the pudendal nerve. In the clinical case, the postoperative course was uneventful. The mean maximum urethral closure pressure and functional profile length increased from 40.7 to 70 cm H2O and from 40.1 to 45.3 mm, respectively. Although urinary incontinence was not completely cured, the patient was able to maintain urinary continence at night. Urethral graciloplasty cross-innervated by the pudendal nerve is effective in raising the urethral pressure and reducing urinary incontinence.

Evaluation of a new method, "non-injection resection using bipolar soft coagulation mode (NIRBS)", for colonic adenomatous lesions

  • Mitsuo Tokuhara;Masaaki Shimatani;Kazunari Tominaga;Hiroko Nakahira;Takuya Ohtsu;Katsuyasu Kouda;Makoto Naganuma
    • Clinical Endoscopy
    • /
    • 제56권5호
    • /
    • pp.623-632
    • /
    • 2023
  • Background/Aims: Endoscopic resection of all colorectal adenomatous lesions with a low complication rate, simplicity, and negative residuals is challenging. Hence, we developed a new method called "non-injection resection using bipolar soft coagulation mode (NIRBS)" method, adapted for colorectal lesions. In addition, we evaluated the effectiveness of this method. Methods: We performed NIRBS throughout a 12-month period for all colorectal lesions which snare resection was acceptable without cancerous lesions infiltrating deeper than the submucosal layer. Results: A total of 746 resected lesions were included in the study, with a 4.5 mm mean size (range, 1-35 mm). The major pathological breakdowns were as follows: 64.3% (480/746) were adenomas, and 5.0% (37/746) were intraepithelial adenocarcinomas (Tis lesions). No residuals were observed in any of the 37 Tis lesions (mean size, 15.3 mm). Adverse events included bleeding (0.4%) but no perforation. Conclusions: NIRBS allowed the resection of multiple lesions with simplicity because of the non-injection and without perforating due to the minimal burn effect of the bipolar snare set in the soft coagulation mode. Therefore, NIRBS can be used to resect adenomatous lesions easily, including Tis lesions, from small to large lesions without leaving residuals.