• Title/Summary/Keyword: Maintenance discharge

Search Result 177, Processing Time 0.032 seconds

A Case Study of On-line PD Measuring System on the Stator Winding for High Voltage Rotating Machine (고전압회전기 고정자권선 운전중 부분방전진단시스템의 현장적용사례 연구)

  • Oh, Bong-Keun;Kang, Dong-Sik;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.109-109
    • /
    • 2010
  • On-line partial discharge(PD) diagnostic system is the most prominent systems to diagnose insulation condition for the high voltage rotating machines. Partial discharge measuring system(PDMS) series with ceramic coupler(PD detecting sensor) installed hydro generator and high voltage motor have been measured the PD data for many years. The trend of PD magnitude in the on-line PD system increased for some machines. These machines showed a same result in the conventional off-line PD test and PD magnitude decreased after stator winding insulation cleaning. This case study show that PDMS has been proved to be good results by comparing PD magnitude with on-line and off-line PD test and it is important to plan the maintenance project for the hydro generator stator winding because PD value was decreased after insulation cleaning.

  • PDF

Surface Degradation of Silicone Rubber Insulator by Salt-fog Test (Salt-fog 분무에 따른 실리콘 고무 애자의 표면열화)

  • 장동욱;박영국;강성화;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.509-512
    • /
    • 1999
  • The main problem in porcelain as a high voltage insulator is that the water film is felled on the insulator surface due to rain, flog, and dew. In the presence of contamination. leakage current increases which may lead to flashover that could be followed by an outage of the power system. These days, high voltage polymer outdoer insulators have been studied and widely used, because they have excellent electrical and mechanical properties, superior performance of flashover for contamination. light weight, easy installation or handling. no maintenance during service, competitive price, and so on. First of a1l the excellent performance of the silicone rubber in polluted and wet conditions is attributed to the ability of the material to maintain the hydrophobicity of the surface in the presence of severe contaminants and wet conditions. This is due to a low surface energy of the silicone rubber. But the leakage current and some surface discharge occurs on the surface of insulator when the insulator is used for a long time. So the leakage current and the surface discharge current are important lo estimate the condition of the silicone rubber surface. In this paper, the average leakage current the surface discharge current the surface rubber surface with the salt fog condition for the first stage.

  • PDF

Analysis of Partial Discharge Characteristics in SF6 Gas Insulation (SF6 가스절연에서 부분방전의 특성분석)

  • Kim, Sun-Jae;Wang, Guoming;Park, Seo-Jun;Kil, Gyung-Suk;An, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.429-434
    • /
    • 2016
  • This paper deals with the characteristics of partial discharge (PD) for the purpose of a condition based maintenance (CBM) of gas insulated switchgears (GIS) in power equipment. Four types of electrode systems such as a protrusion on enclosure (POE), a particle on spacer (POS), a free particle (FP) and a Floating were designed and fabricated. PD pulses were measured using UHF sensor with a frequency range of 300 MHz~1.4 GHz and a DAQ with a sampling rate of 250 MS/s. Discharge inception voltage (DIV), discharge extinction voltage (DEV), and phase resolved partial discharge (PRPD) were analyzed depending on electrode systems. The average DIV in the POS was 28.8 kV. It was about 1.7 times higher than that in the FP, which was the lowest value of 17.2 kV. The FP shuffled and jumped at the applied voltage of 23.5 kV. Over 95% of PD pulses in the POE were generated in the negative polarity ($181^{\circ}{\sim}360^{\circ}$) of applied voltage. The results showed the phase (${\Phi}$)-magnitude (dBm) of PD pulses by UHF sensor, a cluster was formed separately depending on electrode systems.

The Study of the Cavitation for the Urgency Released Valve in Hydraulic Dam (수력댐 비상방류밸브에 대한 캐비테이션에 대한 연구)

  • Roh, Hyung-Woon;Lee, Young-Ho;Lee, Kab-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.5 s.38
    • /
    • pp.14-21
    • /
    • 2006
  • In general, the hollow jet valve, the fixed cone valve had been used for the urgency released or maintenance of the flow rate. Nowadays, the butterfly valve, the gate valve are applied in economic performance and operation maintenance more than the hollow jet valve, the fixed cone valve. However, in the case of butterfly valve, it should be required the strict application standard to the cavitation coefficient because the structural axis and disk were situated in pipe channel and the occurring the shock problem by Karman Vortex. Therefore, there were investigated the valve cavitation and accident investigation by field survey to establish the applicable extensibility of the urgency released valve as the preliminary study.

A study of sensitive reduction from cable when off-line partial discharge measuring (OFF-LINE 부분방전 측정 시 CV케이블에 의한 방전량 감도저하 현상 고찰)

  • Yi, Jong-Seuk;Lee, Eun-Chun;Chae, Ji-seog;Ham, Dong-Younf;Ok, Yeon-Ho;Byun, Du-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1177-1178
    • /
    • 2015
  • 국내 전력설비는 70년대 이후 제3차 경제개발 5개년 계획에 따라 중화학공업의 발전과 함께 급속히 성장해왔다. 과거 개발 위주의 산업구조에서 급속히 팽창한 전력설비는 21세기에 들어서면서 30~40년 장기 사용에 따른 노후화가 진행되었고, 증가하는 전력수요에 대응하기 위한 발전 및 송전 용지 확보의 어려움으로 인하여 전력설비의 신규 증설에 많은 어려움을 격고 있는 실정이다. 따라서 전력설비의 안전성과 신뢰성을 확보하기 위해 적절한 교체시기 선정 및 최적의 자산관리 필요성에 대해서 최근 관심을 가지기 시작하였고, 이러한 전력설비의 최적 자산관리에 핵심적인 전력설비의 상태평가 기술의 발달로 과거 시간기준의 유지보수(Time Based Maintenance)에서 최근 노후설비의 증가와 진단기술의 발달에 따른 예방보전(Preventive Maintenance)에 의한 상태기준 유지보수(Condition Based Maintenance)개념으로 전환되고 있다. 고전압 회전기기(발전기, 전동기)의 상태평가를 위한 핵심기술인 Off-line 부분방전시험이 널리 적용되고 있으며, 본 논문에서는 부분방전 측정 시험 시 대상설비 단자부의 인출케이블에 의한 감도저하 현상에 대해 고찰 하였다.

  • PDF

A Study of Home Care Needs of Patients at Discharge and Effects of Home Care -Centered on Patients Discharged from a Rural General Hospilal- (퇴원환자의 가정간호요구와 가정간호사업의 효과 분석 - 일 종합병원을 중심으로)

  • Choi, Yun Soon;Kim, Dai Hyun;Storey, Margaret;Kim, Cho Ja;Kang, Kyu Sook
    • The Korean Nurse
    • /
    • v.31 no.4
    • /
    • pp.77-99
    • /
    • 1992
  • The study was carried out at W. hospital, an affiliated hospital of Y university, involved a total of 163 patients who were discharged from the hospital between May 1990 und March 199J. Data collection was twice, just prior to discharge and a minimum of three months post discharge. Thirty patients who lived within a hour travel time of the hospital received home care during the three months post discharge. Nursing diagnoses and nursing interventions For these patients were analyzed in this study. The results of the study are summarized as follows : 1. Discharge needs for the subjects of the study were analyzed using Gordon's eleven Functional categories and it was found that 48.3% of the total sample had identified nursing needs. Of these, the needs most frequently identified were in the categories of sexuality, 79.3 %, health perception, 68.2 % self concept, 62.5 %, and sleep and rest 62.5 %. Looking ut j he nursing diagnosis that were made for the 30 patients receiving home care, the following diagnoses were the most frequently given; alteration in sexual pattern 79.3%, alterations in health maintenance, 72.6%, alteration in comfort, 68.0%, depression, 64.0%, noncompliance with diet therapy, 6.3.7%, alteration in self concept, 55.6%, and alteration in sleep pattern, 53%. 2. In looking at the effects of home nursing care as demonstrated by changes in the functional categories over the three month period, it was Found that of the 11 functional categories, the need level for health perception, nutrition, activity and self concept decreased slightly over the three month period. On the average sleep patterns improved, but restfulness was slightly less and bowel elimination patterns improved but satisfaction with urinary elimination was slightly less. On the other hand, role enactment, sexuality, stress management and spirituality decreased slightly. The only results that were statistically significant at the 0.05 level were improvement. in digestion and decrease in pain. No statistically significant changes were found in ability related to ADL, the total ADL Score at discharge was $19.78{\pm}8.234, and after 3 months $19.01{\pm}8.12$. Considering that a majority of the patients were over 60 years of age and that many had brain or spinal cord injuries, the fact that their ADL ability did nor deteriorate after discharge can be interpreted as related to a positive impact by the home health care nurses. Similarly there was a slight be not statistically significant decrease in the quality of life scores between the two lest times(l47.83 at discharge and 113.02 at the three month period). Again, when the chronic nature of thee problems facing these patients is considered this maintenance of quality of life can be interpreted as a positive impact by the home health care nurses. 3. One of the home care nursing activities was diagnosis. For this activity it was found that for nine functional health categories(sexuality and spirituality excepted) there were 20 nursing diagnoses. The most frequent were noncompliance, alteration in skin integrity both actual and potential, and impaired physical mobility in that order. 4. Delivery of home health care by the home health nurses included the following nursing activities; assessment, patient education, demonstration of care activities, counselling, direct care to the patient and referrals. Direct care included changing dressings, bladder irrigations, changing Foley catheters, measurement of residual urine, perineal care, position change, back care, oral hygiene, exercise and massage of motion exercises, cleansing enemas, tracheostomy suctioning and tracheostomy care, care of dentures, applications of heat and other similar nursing activities. In conclusion almost 50% of (he sample indicated a need for continued nursing care at the time of discharge and for the patients in the sample who received home care there was a slight decrease in nursing needs but while the patients had chronic and debilitation problems there was ill decrease in ADL abilities or in quality of life. Further study needs Lo be done La increase the reliability and validity of the tool that was used to measure home health care needs. It is also recommended that study by done using a randomized sampling with a control group to compare patients who receive home care with those who do not.

  • PDF

Effect of Corona Discharge on the Changes in Quality and Pasteurization of Ginseng Powder (코로나방전 처리 인삼분말의 살균효과 및 품질변화)

  • Kim, Kyung-Tack;Kim, Sung-Soo;Ha, Sang-Do
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1237-1243
    • /
    • 2003
  • As a newly emerging pasteurization method for improving the shelf-life of powdered ginseng, the corona discharge generated at high voltage conditions was examined for its effects on microbial pasteurization, physicochemical characterization, and sensory evaluation. The pasteurizing effects of corona discharge on total bacteria, yeast, molds, and coliforms increased with increasing voltage. However, corona discharge treatment of 5 kv/cm did not show significant effects of pasteurization on the yeast, molds, and coliforms. Treatment with 20 kv/cm reduced about 95% of the total bacteria $(6.14{\pm}0.04{\rightarrow}\;4.59{\pm}0.04$) and coliforms ($2.43{\pm}0.05{\rightarrow}\;1.00{\pm}0.05$) and 99% of the yeast and molds ($4.65{\pm}0.06{\rightarrow}\;2.73{\pm}0.06$). The proximate analysis, minerals, free sugars, crude saponin, and colors of the control ginseng and the ginseng treated with 20 kv/cm were not significantly different at p<0.05. Corona discharge of up to 20 kv/cm did not affect the proximate analysis, minerals, free sugars, crude saponin, and colors of the powdered ginseng. Sensory evaluation scores on color, flavor, taste and overall acceptability between the control ginseng and ginseng treated with 20 kv/cm corona discharge were not significantly different at p<0.05 level. Consequently, corona discharge treatment is thought to be a good alternative pasteurization method for improving the shelf-life of powdered ginseng due to its effective pasteurization, maintenance of nutrients and good sensory characteristics.

Study on Estimation for Discharge Coefficient of Diagonal Weir (경사 위어의 유량계수 산정에 대한 연구)

  • Im, Jang-Hyuk;Jin, Sin-Wook;Song, Jai-Woo
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.5
    • /
    • pp.375-383
    • /
    • 2009
  • This study examined hydraulic characteristics on diagonal weirs with hydraulic experiment and presented a discharge coefficient equation utilizing multiple regression analysis for various design conditions. This study had a object in designing efficiently diagonal weirs utilizing this equation. Diagonal weirs maintained uniformly upstream water level than rectangular suppressed weirs. Also, as installation degrees of diagonal weirs increased, diagonal weirs increased maintenance effects of a upstream water level. Because of these characteristics, diagonal weirs were suitable to canal system. This study presented discharge coefficient equations for diagonal weirs utilizing simple regression analysis. But, these equations are some restrictions on degrees. Therefore, this study presented an equation to estimate directly discharge coefficients to various degrees utilizing multiple regression analysis. This equation was verified by making use of analyses of $R^2$, the sum of residuals, MAPE. Therefore, this equation is enable to make good use of a design in diagonal weirs.

Fundamental Study on the Maintenance Technology for SF6 Gas Condition using Pressure and UHF Sensors (UHF 및 가스센서를 이용한 SF6 가스 상태 감시기술 기초연구)

  • Ahn, Hee-Sung;Cho, Sung-Chul;Eom, Ju-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.20-27
    • /
    • 2007
  • [ $SF_6$ ] gas for compacted power facilities has a important role as an insulation gas. It is very blown well that $SF_6$ gas has the superior characteristics as an insulation gas. For reliable operation of SF6-gas-based high and medium voltage equipment it is very important to keep the insulation ability within a safe range. And the experimental and measuring system were implemented. The test chamber designed to endure up to 3 atmospheric pressure. The analysis results of the experimental data shows that positive partial discharge can be detected by discharge current and UHF signal. Additionally it is shown the possibility that $CO_2$ gas sensor of semiconductor type can be detect the variation of $SF_6$ gas condition. The UHF sensor shows good feature to detect the variation of $SF_6$ gas condition for partial discharge and breakdown discharge.

A Study on Evaluation for Hydraulic and Hydrologic Safety of an Existing Dam with Morning Glory Spillway (나팔형 여수로를 가진 기존댐의 수리·수문학적 안전성평가에 관한 연구)

  • Shin, Eun-Woo;Kim, Kyung-Duk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.2
    • /
    • pp.269-278
    • /
    • 2004
  • In this study, hydraulic and hydrologic safety of an existing dam with morning glory spillway was evaluated and the problems were derived in order to control extreme floods efficiently. For design flood(520cms and EL. 170.3m), the spillway was turned out to have no problem for discharge and negative pressure in vertical transition. However, the critical point for discharge starts with EL. 170.7m which transits weir flow condition to orifice flow condition and there may be negative pressure in weir crest. While maximum water level can not be greater than EL. 170.5m including freeboard according to the dam design criteria, the maximum water level based on reservoir routing was turned out to be EL. 172.46m, and fundamental measures should be requested and planned.