• Title/Summary/Keyword: Main pump

Search Result 473, Processing Time 0.031 seconds

Cause Analysis for Reduced Effect of Sewer Pipe Improvement Project Based On Investigation of Interceptor Sewers (차집관로의 조사 및 분석을 통한 하수관로정비 사업의 효과 감소 원인 분석)

  • Chae, Myungbyung;Bae, Younghye;Kim, Hungsoo
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.219-226
    • /
    • 2018
  • Interceptor sewer is installed underground near to the river side mostly ofstate-owned land and the management efficiency of public sewage disposal facilities is decreasing as too much infiltration/inflow(I/I) and river flow to interceptor sewer are caused by broken or deteriorated sewer. This also affects the sewer pipeline project and decreases its efficiency. Therefore, the aim of this study is to investigate interceptor sewer which has influence on the reduction of the project effect. The investigation were performed for three study areas. The study includes the investigation of current condition of interceptor sewer(sewer extension, pipe diameter, pipe type, installed year, installed locations, etc), investigation of inside of sewer by CCTV accompanied by pumping and dredging works where required, investigation of inside of manholes by eyes, calculation of pollutant load using the results of investigation of flow quantity and quality. Multipoint investigations were simultaneously performed for flow quantity at confluence area and other investigations were also performed for flow quantity and BOD for interceptor sewer and comparison of pollutant load, investigation of infiltration/inflow(I/I) caused by deterioration of interceptor sewer. As the result of the study, a main reason for reduced effect of sewer pipe improvement project was analyzed as the low-density sewage and I/I in public seweage treatment Facility due to deteriorated and unmanaged interceptor sewers.

Evaporation Heat Transfer Characteristics of Carbon Dioxide in a Diameter Tube of 4.57mm (내경 4.57mm 관내 CO2의 증발 열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.574-579
    • /
    • 2008
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 4.57mm. The experiments were conducted at mass flux of 400 to $900kg/m^2s$, saturation temperature of 5 to $20^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much. In comparison with test results and existing correlations, All of the existing correlations for the heat transfer coefficient underestimated the experimental data. However Jung et al.'s correlation showed a good agreement with the experimental data. Therefore, it is necessary to develope accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in horizontal tubes.

Remote Monitoring Panel and Control System for Chemical, Biological and Radiological Facilities (화생방 방호시설을 위한 원격감시 패널 및 제어시스템)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.464-469
    • /
    • 2019
  • A remote monitoring panel and control system was developed to control various valves and access control chambers, including gas shutoff valves used in CBR(Chemical, Biological and Radiological) facilities. The remote monitoring panel consisted of a main panel installed in the NBC (Nuclear, Biological and Chemical) control room and auxiliary panel installed in the clean room, and the size was divided into pure control and control including CCTV. This system can be monitored and controlled remotely according to the situation where an explosion door and gas barrier door can occur during war and during normal times. This system is divided into normal mode and war mode. In particular, it periodically senses the operation status of various valves, sensors, and filters in the CBR facilities to determine if each apparatus and equipment is in normal operation, and remotely alerts situation workers when repair or replacement is necessary. Damage due to the abnormal operation of each device in the situation can be prevented. This enables control of the blower, supply and exhaust damper, emergency generator, and coolant pump according to the state of shutoff valve and positive pressure valve in the occurrence of NBC, and prevents damage caused by abrupt inflow of conventional weapons and nuclear explosions.

Dredging Material High Efficiency Transport Technology Test by Using the Electro Magnetic Field and Development of the Technical Design Manual (전자기장을 이용한 준설토 고효율 이송기술 실증 및 기술 지침 개발)

  • Kim, Dong-Chule;Kim, Yu-Seung;Yea, Chan-Su;Kim, Sun-Bin;Park, Seung-Min
    • Journal of Coastal Disaster Prevention
    • /
    • v.5 no.4
    • /
    • pp.173-182
    • /
    • 2018
  • As the research about increasing the efficiency of dredging soil transport, the technology, which reduce the friction between pipe wall and fluid in the pipe and disturbed generating pipe blockage, has been developed. So for the purpose of applying this technology to real construction site, main test has been tried at the real scale test in field. As a test result, this paper will show 30% flow efficiency increasing by permitted electro magnetic force to the pipe. And test result was evaluated as a ultra sonic velocity profiler. To propose the design technique and the execution manual of the high efficiency dredging material transport technic, this research have confirmed flow status changing depending on a soil material kind under electro-magnetic field and analyze the effect of electro-magnetic field which affects to each dredged soil material transportation. For achieving this research, EMF(Electro-Magnetic Field) generator is installed on the dredger(20,000HP) and through monitored flow status, dredging soil flow rate and sampled material specification is confirmed. Also dredger operating condition is measured and dredger power for soil transportation, hydraulic gradient and flow rate are compared, as transportation efficiency is calculated by this parameter, it is possible to check transportation efficiency improvement depending on each dredged soil material under electro-magnetic field. To verify the technique of dredged soil transfer using electromagnetic field, which is the core technique of the high efficiency dredged soil transfer, and the technique of expert system for pipeline transfer and the flow state. This could lead to a verification of transfer efficiency according to the characteristics of the dredged soil (sand, clay, silt) and the transfer distance (5km, 10km, 15km), which is planned to be used for a technology development of pump power reduction and long-distance transfer applying the high efficiency dredged soil transfer technology.

A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.

Compressed Demographic Transition and Economic Growth in the Latecomer

  • Inyong Shin;Hyunho Kim
    • Analyses & Alternatives
    • /
    • v.7 no.2
    • /
    • pp.35-77
    • /
    • 2023
  • This study aims to solve the entangled loop between demographic transition (DT) and economic growth by analyzing cross-country data. We undertake a national-level group analysis to verify the compressed transition of demographic variables over time. Assuming that the LA (latecomer advantage) on DT over time exists, we verify that the DT of the latecomer is compressed by providing a formal proof of LA on DT over income. As a DT has the double-kinked functions of income, we check them in multiple aspects: early maturation, leftward threshold, and steeper descent under a contour map and econometric methods. We find that the developing countries (the latecomer) have speedy DT (CDT, compressed DT) as well as speedy income such that DT of the latecomers starts at lower levels of income, lasts for a shorter period, and finishes at the earlier stage of economic development compared to that of developed countries (the early mover). To check the balance of DT, we classify countries into four groups of DT---balanced, slow, unilateral, and rapid transition countries. We identify that the main causes of rapid transition are due to the strong family planning programs of the government. Finally, we check the effect of latecomer's CDT on economic growth inversely: we undertake the simulation of the CDT effect on economic growth and the aging process for the latecomer. A worrying result is that the CDT of the latecomer shows a sharp upturn of the working-age population, followed by a sharp downturn in a short period. Compared to early-mover countries, the latecomer countries cannot buy more time to accommodate the workable population for the period of demographic bonus and prepare their aging societies for demographic onus. Thus, we conclude that CDT is not necessarily advantageous to developing countries. These outcomes of the latecomer's CDT can be re-interpreted as follows. Developing countries need power sources to pump up economic development, such as the following production factors: labor, physical and financial capital, and economic systems. As for labor, the properties of early maturation and leftward thresholds on DTs of the latecomer mean that demographic movement occurs at an unusually early stage of economic development; this is similar to a plane that leaks fuel before or just before take-off, with the result that it no longer flies higher or farther. What is worse, the property of steeper descent represents the falling speed of a plane so that it cannot be sustained at higher levels, and then plummets to all-time lows.

Emergency Coronary Artery Bypass Operation for Card iogen ic Shock (심인성 쇼크에 대한 응급 관상동맥 우회술)

  • 김응중;이원용
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.966-972
    • /
    • 1997
  • Between June 1994 to August 1996, 13 patients underwent emergency coronary artery bypass operations. There were 3 males and 10 females and ages ranged from 56 to 80 years with the mean of 65.5 years. The indications for emergency operations were cardiogenic shock in 12 cases and intractable polymorphic VT(ve'ntricular tachycardia) in 1 case. The causes of cardiogenic shock were acute evolving infarction in 6 cases, PTCA failure in 4 cases, acute myocardial infarction in 1 case, and post-AMI VSR(ventricular septal rupture) in 1 case. Pive out of 13 patients could go to operating room within 2 hours. However, the operations were delayed from 3 to 10 hours in 8 patients due to non-medical causes. In 12 patients, 37 distal anastomoses were constructed with only 3 LITA's(left internal thoracic arteries) and 34 saphenous veins. In a patient with post-AMI VSR, VSR repair was added. In a patient with intractable VT and critical sten sis limited to left main coronary artery, left main coronary angioplasty was performed. Pive patients died after operation with the operative mortality of 38.5%. Three patients died in the operating room due to LV pump failure, one patient died due to intractable ventricular tachycardia on postoperative second day, and one patient died on postoperative 7th day due to multi-organ failure with complications of mediastinal bleeding, low cardiac output syndrome, ARF, and lower extremity ischemia due to IABP. In 8 survived patients, 3 major complications (mediastinitis, PMI, UGI bleeding) developed but eventually recovered. We think that the aggressive approach to critically ill patients will salvage some of such patients and the most important factor for patient salvage is early surgical intervention before irreversible damage occurs.

  • PDF

Risk Assessment of Agricultural Worker's Exposure to Fungicide Thiophanate-methyl during Treatment in Green Pepper, Cucumber and Apple Fields (고추, 오이 및 사과 재배 중 살균제 Thiophanate-methyl 살포 시 농작업자의 노출 및 위해 평가)

  • Choi, Hoon;Kim, Jeong-Han
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.1
    • /
    • pp.73-81
    • /
    • 2014
  • The present study was carried out to assess exposure and risk to thiophanate-methyl wettable powder for agricultural worker during mixing/loading and application with power sprayer in green pepper, cucumber and apple fields. Dermal exposure was measured with patches, gloves, socks and masks, while inhalation exposure was evaluated with personal air pump and solid sorbent. Those methods were full validated before experiment. During mixing/loading, dermal exposure amount in green pepper, cucumber and apple fields was $24.0{\pm}6.7$, $4.5{\pm}1.5$ and $18.5{\pm}0.6mg$, corresponding to mean 0.007, 0.001 and 0.005% of prepared active ingredient, respectively. The major exposed part for mixer/loader was hands (78-92%). Dermal exposure amount for applicator in green pepper, cucumber and apple fields was $84.9{\pm}14.0$, $34.0{\pm}20.8$ and $30.7{\pm}9.1mg$, corresponding to mean 0.024, 0.016 and 0.013% of applied active ingredient, respectively. The main body parts of exposure in apple field were hands, while thighs and shins in other fields. Inhalation exposure amount in green pepper, cucumber and apple fields was $1.5{\pm}2.2$, $52.7{\pm}48.9$ and $4.0{\pm}4.9{\mu}g$ during mixing/loading and $0.2{\pm}0.1$, $23.2{\pm}12.4$ and $0.4{\pm}0.6{\mu}g$ for applicator, respectively. These results were suggested that main factors affecting dermal exposure were contact frequency to the plants, foliage density, hygienic behavior, work type, and working environment, while inhalation exposure was affected mainly by working environment, especially wind. In risk assessment, margin of safety for thiophanate-methyl in all cases was over 1. However, during application in green pepper field, margin of safety was close to 1.

Mid-Term Results of 292 cases of Coronary Artery Bypass Grafting (관상동맥 우회술 292례의 중기 성적)

  • 김태윤;김응중;이원용;지현근;신윤철;김건일
    • Journal of Chest Surgery
    • /
    • v.35 no.9
    • /
    • pp.643-652
    • /
    • 2002
  • As the prevalence of coronay artery disease is increasing, the surgical treatment has been universalized and operative outcome has been improved. We analyzed the short and mid-term results of 292 CABGs performed in Kangdong Sacred Heart Hospital. Material and Method: From June 1994 to December 2001, 292 patients underwent coronary artery bypass grafting. There were 173 men and 119 women and their ages ranged from 39 to 84 years with a mean of $61.8{\pm}9.1$ years. We analyzed the preoperative risk factors, operative procedures and operative outcome. In addition, we analyzed the recurrence of symptoms, long-term mortality and complications via out-patient follow-up for discharged patients. Result: Preoperative clinical diagnoses were unstable angina in 137(46.9%), stable angina in 34(11.6%), acute myocardial infarction in 40(13.7%), non-Q myocardial infarction in 25(8.6%), postinfarction angina in 22(7.5%), cardiogenic shock in 30(10.3%) and PTCA failure in 4(1.4%) patients. Preoperative angiographic diagnoses were three-vessel disease in 157(53.8%), two-vessel disease in 35 (12.0%), one-vessel disease in 11(3.8%) and left main disease in 89(30.5%) patients. We used saphenous veins in 630, internal thoracic arteries in 257, radial arteries in 50, and right gastoepiploic arteries in 2 distal anastomoses. The mean number of distal anastomoses per patient was $3.2{\pm}1.0$ There were 18 concomitant procedures ; valve replacement in 8(2.7%), left main coronary artery angioplasty in 6(2.1%), patch closure of postinfarction ventricular septal defect(PMI-VSD) in 2(0.7%), replacement of ascending aorta in 1(0.3%) and coronary endarterectomy in 1(0.3%) patient. The mean ACC time was $96.6{\pm}35.3 $ minutes and the mean CPB time was $179.2{\pm}94.6$ minutes. Total early mortality was 8.6%, but it was 3.1% in elective operations. The most common cause of early mortality was low cardiac output syndrome in 6(2.1%) patients. The stastistically significant risk factors for early mortality were hypertension, old age($\geq$ 70 years), poor LV function(EF<40%), congestive heart failure, preoperative intraaortic balloon pump, emergency operation and chronic renal failure. The most common complication was arrhythmia in 52(17.8%) patients. The mean follow-up period was $39.0{\pm}27.0$ months. Most patients were free of symptoms during follow-up. Fourteen patients(5.8 %) had recurrent symptoms and 7 patients(2.9%) died during follow-up period. Follow-up coronary angiography was performed in 13 patients with recurrent symptoms and they were managed by surgical and medical treatment according to the coronary angiographic result. Conclusion: The operative and late results of CABG in our hospital, was acceptable. However, There should be more refinement in operative technique and postoperative management to improve the results.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.