• Title/Summary/Keyword: Main flow

Search Result 3,304, Processing Time 0.049 seconds

A Suggested Mechanism of Significant Stall Suppression Effects by Air Separator Devices in Axial Flow Fans

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.57-66
    • /
    • 2011
  • Radial-vaned air separators show a strong stall suppression effect in an axial flow fans. From a survey of existing literature on the effects and the author's data, a possible mechanism for the significant effects has been proposed here. The stall suppression is suggested to have been achieved by a combination of the following several effects; (1) suction of blade and casing boundary layers and elimination of embryos of stall, (2) separation and straightening of reversed swirling flow from the main flow, (3) induction of the fan main flow toward the casing wall and enhancement of the outward inclination of meridional streamlines across the rotor blade row, thus keeping the Euler head increase in the decrease in fan flow rate, and (4) reinforcement of axi-symmetric structure of the main flow. These phenomena have been induced and enhanced by a stable vortex-ring encasing the blade tips and the air separator. These integrated effects appear to have caused the great stall suppression effect that would have been impossible by other types of stall prevention devices. Thus the author would like to name the device "tip-vortex-ring assisted stall suppression device".

Improvement of a Flow Coefficient for the Recirculation Chill-down Flow in a Main Oxidizer Shut-off Valve (연소기 산화제 개폐밸브 재순환예냉 유로의 유량계수 개선)

  • Hong, Moongeun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.4
    • /
    • pp.89-95
    • /
    • 2017
  • The improvement of a flow coefficient for the recirculation chill-down flow in a main oxidizer shut-off valve has been presented. The flow coefficient, which is mainly affected by the recirculation outlet port size and the configuration inside the valve, has been predicted with measured flow coefficient values. The comparison of experimentally measured flow coefficient with the predicted value shows the effect of valve inside configuration on the flow coefficient. Consequently, the flow coefficient is twice the previous value and about 75% of the pressure loss assigned to the main oxidizer shut-off valve can be used for additional pressure losses for other components in the recirculation chill-down system of a launch vehicle.

Simulation Analysis on the Air Flow Inside Computer Main Frame According to the Location of Fan (팬의 위치에 따른 컴퓨터 본체 내부의 공기유동에 관한 시뮬레이션 해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.2
    • /
    • pp.259-266
    • /
    • 2012
  • In this study, the temperature distributions are analyzed on the air flow according to the position of fan inside computer main frame by CFD simulation. In case that ventilation hole is existed at the side of computer frame, the air with lower temperature can be circulated near CPU radiant thermal panel. In case of installation with fan at the side panel, the temperature of air flow becomes lowest. The efficiency of thermal emission at personal computer and its durability can be improved by releasing a lot of heat at air flow effectively inside computer frame according to this simulation result.

Numerical Analysis Study of the Mixing Mechanism of Non-element Mixer (논 엘레멘트 믹서의 혼합 메커니즘에 관한 수치해석적 검토)

  • You, Sun Ho
    • Journal of ILASS-Korea
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Visualization of the mixing pattern in a non-element mixer was carried out using laser induced fluorescence(LIF) to evaluate characteristics of mixer consisting of the main flow pipe and branch flow pipes. The branch flows were injected periodically with the period $T_{in}$ normal to the main flow, and rhodamine B was mixed into the most upstream branch flow to visualize mixing pattern in the main flow pipe by LIF. The length of boundary line L of the LIF image was measured. In this study, a numerical analysis was performed to identify the mixing process of the non-element mixer, and the results were compared with experimental results. Each result was almost the same. When the number of branch flows is increased, the mixing pattern became complicated and was supposed to become chaotic. The length of boundary line L increased exponentially with an increase in the number of branch flows.

A Study on the Flow Characteristic of Lubrication Oil System in Manual Transmission System for Large Commercial Vehicle (대형 상용차용 수동변속기내 윤활시스템의 유동특성에 관한 연구)

  • Yi, Chung-Seob;Suh, Jeong-Se;Song, Chul-Ki;Shin, Yoo-In;Yun, Ji-Hun;Chung, Kyung-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.6
    • /
    • pp.77-82
    • /
    • 2010
  • This study has conducted numerical analysis for lubrication system of transmission for commercial vehicle. The lubrication oil system in transmission can be applied to a large scale commercial vehicle which is over 15tons. The flow rate of lubricating oil has been obtained for each of branch port from the lubrication pipe. The results from numerical simulation are mainly suggested for the mass flow rate of lubrication oil in the rotating main shaft of transmission system. It has been found that the mass flow rate from oil hole increased with an rotating rate of main shaft. The flow characteristic from oil hole has been presented for the lubricating system in the manual transmission.

Reduction of Fire Main Pipe System's Vibration Using Back Flow Prevent Globe Valve (역류방지 글로브 밸브를 이용한 소화 주관계의 진동개선)

  • Park, Mi-You;Han, Hyung-Suk;Lee, Seuk-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.518-523
    • /
    • 2009
  • Main source of URN(Underwater Radiated Noise) which is related to the ship's survivability is divided into two groups. Cavitation is main source of URN when the speed of ship is upper than CIS(Cavitation Inception Speed). But when the speed of ship is lower than CIS, main source of URN is structure-borne noise on the hull which is originated from propulsion system, pump system or transmitted vibration of pipe system. In this paper, to reduce the vibration of discharge pipe and valve system, back flow prevent globe valve and new rubber mount are applied to the ship. As the result of applying new valve and mount, the vibration is reduced drastically.

  • PDF

Reduction of Fire Main Pipe System's Vibration Using Back Flow Prevent Globe Valve (역류방지 글로브 밸브를 이용한 소화 주관계의 진동개선)

  • Park, Mi-You;Han, Hyung-Suk;Lee, Seuk-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.6
    • /
    • pp.599-606
    • /
    • 2009
  • Main source of URN(underwater radiated noise) which is related to the ship's survivability is divided into two groups. Cavitation is the main source of URN when the speed of ship is upper than CIS(cavitation inception speed). But when the speed of ship is lower than CIS, the main source of URN is the structure-borne noise on the hull which is originated from propulsion system, pump system and trnasmitted vibration of the pipe system. In this paper, to reduce the vibration of discharge pipe and valve system, back flow prevent globe valve and new rubber mount are applied to the ship. As the result of applying new valve and mount, the vibration is reduced drastically.

Augmented heat transfer in a rectangular duct with angled ribs (사각 덕트내 요철의 각도 변화에 따른 열전달 특성)

  • U, Seong-Je;Kim, Wan-Sik;Jo, Hyeong-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.530-541
    • /
    • 1998
  • Heat transfer augmentation in a rib-roughened duct is affected by the rib configurations, such as rib height, angle of attack, shape, rib to rib pitch, and aspect ratio of a duct. These have been the main subjects in studying the average heat transfer and the friction loss of the fully developed flow. Investigating distributions of local heat transfer coefficients and flow patterns in a duct with the rib turbulators is necessary to find the characteristics of heat transfer augmentation and to decide the optimal configurations of ribs. In the present study the numerical analyses and the mass transfer experiments are performed to understand the flow through a rib roughened duct and the heat transfer characteristics with various angles of attack of ribs. A pair of counter-rotating secondary flow in a duct has a main effect on the lateral distributions of local mass transfer coefficients. Downwash of the rotating secondary flow, reattachment of main flow between ribs and the vortices near ribs and wall enhanced the mass transfer locally up to 8 times of that in case of the duct without ribs.

A Study on the Descriptive Method and Common Terminology of 『Yeongchu·Gyeonggeun(靈樞·經筋)』 (≪영추(靈樞)·경근(經筋)≫의 서술 방법과 공통 용어에 대한 연구)

  • Min-Sik Kim;Chang-Geon Kim;So-Rim Kim;Eun-Yong Lee
    • The Journal of Korean Medicine
    • /
    • v.44 no.1
    • /
    • pp.56-64
    • /
    • 2023
  • Objectives & Methods: The entire ≪Lingshu·Jingjin≫ content was analyzed to find repetitive patterns, as well as to analyze commonly used terms. Through this, the guidelines for interpretation were presented. Results & Conclusions: ≪Lingshu·Jingjin≫ is not a question-and-answer format, but a simple enumerated narrative format. There is no part corresponding to the introduction, only the descriptions of 12 individual Meridian-muscle exist. Each Meridian-muscle is divided into 'Flow of Muscle Mechanics(流走)' part and 'Diseases' part, and 'Flow of Muscle Mechanics' of each Meridian-muscle can be divided into 'Main Flow' and 'Branch'. 'Main Flow' is the most central 'Flow' in each 'Meridian-muscle', and 'Branch' is the part where 'Main Flow' ends and the description of another 'Flow' begins. 'Branch' has different expressions according to the importance. The expression also varies depending on the dynamics. 'Meridian-muscle' should be interpreted based on this.

Intelligent Tuning of the Two Degrees-of-Freedom Proportional-Integral-Derivative Controller On the Distributed Control System for Steam Temperature Control of Thermal Power Plant

  • Dong Hwa Kim;Won Pyo Hong;Seung Hack Lee
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.78-91
    • /
    • 2002
  • In the thermal power plant, there are six manipulated variables: main steam flow, feedwater flow, fuel flow, air flow, spray flow, and gas recirculation flow. There are five controlled variables: generator output, main steam pressure, main steam temperature, exhaust gas density, and reheater steam temperature. Therefore, the thermal power plant control system is a multinput and output system. In the control system, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, strict control of the steam temperature must be maintained to avoid thermal stress. Maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature versus changes in fuel flow rate, difficulty of control of the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, and the fluctuation of inner fluid water and steam flow rates during the load-following operation. Up to the present time, the Proportional-Integral-Derivative Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on the characteristic comparison of the PID controller and the modified 2-DOF PID Controller (Two-Degrees-Freedom Proportional-Integral-Derivative) on the DCS (Distributed Control System). The method is to design an optimal controller that can be operated on the thermal generating plant in Seoul, Korea. The modified 2-DOF PID controller is designed to enable parameters to fit into the thermal plant during disturbances. To attain an optimal control method, transfer function and operating data from start-up, running, and stop procedures of the thermal plant have been acquired. Through this research, the stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Also, this paper addressed whether an intelligent tuning method based on immune network algorithms can be used effectively in tuning these controllers.

  • PDF