• 제목/요약/키워드: Main beam

검색결과 1,078건 처리시간 0.028초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

AMC G-Box를 이용한 영상유도장치의 효율적인 정도관리 (The effective quality assurance for image guided device using the AMC G-Box)

  • 김정미
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.199-206
    • /
    • 2014
  • 목 적 : 최근 영상유도 방사선치료의 급증에 따라 영상유도장치의 정도관리를 철저히 시행할 필요가 있다. 특히 영상유도 방사선치료는 장치의 정확성을 기본 전제로 하기 때문에 이에 대한 정도관리가 필수적으로 행해져야 한다. 본원에서는 영상유도장치의 정도관리를 기존의 팬텀(Phantom)보다 효율적인 팬텀을 자체 제작하여 정확하고 효율적인 정도관리를 이행하고자 한다. 대상 및 방법 : 영상유도장치의 정도관리 항목으로 매우 중요한 5가지를 설정하고, 그 항목에 대하여 효율적이고 정확한 정도관리가 이루어 질 수 있는 팬텀(AMC G-Box)을 자체 제작하였다. 정도관리 항목은 Iso-center와 영상유도장치의 중심 일치성, 구현된 영상의 실측 정확성, 4 방향의 중심일치성, 영상유도 이동의 정확성 및 CBCT(Cone Beam CT)에서 구현된 HU(Hounsfield Unit)의 재현성으로 설정하였다. 이 항목에 대하여 $10cm{\time}10cm{\time}10cm$의 정사각형 팬텀을 1 cm두께의 아크릴로 제작하였으며 CBCT HU을 측정하기 위해 팬텀안에 각각 밀도가 다른 3개의 물질을 삽입하였다. 팬텀에는 중심과 일정한 위치를 가리키는 표식을 만들어서 중심과 일치성 검사를 할 수 있도록 하였다. 실험은 기존 각각의 팬텀을 이용한 정도관리를 실시하고, 새로 제작된 AMC G-Box로 실시한 후 그 결과 값을 비교하고 소요되는 시간과 문제점을 분석하였다. 사용된 치료기는 Varian사의 4개의 모델이고, 1주 간격으로 2회 측정하였다. 결 과 : 완성된 AMC G-Box를 이용한 영상유도장치의 정도관리를 시행하였을 때, 기존 개별로 구성된 팬텀을 이용한 정도관리 결과를 보았을 때, $0.2mm{\pm}0.1$이내에서 결과 값이 같았다. 또한 기존의 방법일 경우 최소 30분에서 45분이 소요되었으나, AMC G-Box를 이용하였을 때는 15분~20분이 소요되어 50%이상 시간을 감소하였다. 결 론 : 영상유도장치는 사용기간이 지남에 따라 일치성과 정확성이 떨어지는 경향이 있다. 따라서 관련된 정도관리를 주기적으로 철저하게 할 필요성이 있다. 특히 일치성 검사는 매일 점검해야하는 항목이다. 이러한 정도관리를 AMC G-Box를 이용할 경우 정확한 정도관리를 효율적으로 실시함으로써, 장치와 환자 치료의 안정성과 정확성을 높일 수 있었다.

방송과 통신 융합시스템의 수용 및 상대적 효능에 관한 연구: IPTV를 중심으로 (A Study on the Acceptance of Convergence System of Broadcasting, and Telecommunication, and Their Relative Efficiency Focusing on IPFV)

  • 염병용;이상호;김재범
    • Asia pacific journal of information systems
    • /
    • 제19권3호
    • /
    • pp.25-49
    • /
    • 2009
  • Advances in technology have resulted in the emergence of new information systems. The convergence of IT and manufacturing sectors has blurred the boundaries among industries. Also, such convergence has become established as a paradigm to build a new area. Especially the convergence of broadcasting and telecommunication, notably in the case of IPTV (Internet Protocol Television), is among the most salient examples of its kind in recent years as a major case of disruptive technology innovation. Despite its much fanfare, such convergence, however, has not fulfilled the expectation; it has not produced positive economic effects while negatively affecting the growth of IPIV. Stakeholders in and around IPIV including telecommunication companies, broadcasting corporations, and government bodies wish to gain control of IPTV under their wings. IPTV has drifted in the midst of conflicts among the stakeholders in and around IPTV, particularly telecommunication and broadcasting organizations in a broad sense. Our empirical research intends to deal with how audiences accept IPTV and how firms provide IPTV services to utilize their resources. Three research questions in this paper include, first, whether Technology Acceptance Model (TAM) can sufficiently explain the acceptance of IPTV as an information system. The second question concerns with empirically testing the playful aspect of IPTV to increase its audience acceptance. Last, but not least, this paper deals with how firms can efficiently and effectively allocate their limited resources to increase IPTV viewers. To answer those three main questions of our study, we collect data from 197 current subscribers of high speed internet service and/or cable/satellite television. Empirical results show that 'perceived usefulness (PU) $\rightarrow$ Intention to use' and 'perceived ease of use (PEU) $\rightarrow$ Intention to use' are significant. Also, 'perceived ease of use' is significantly related to 'perceived usefulness.' Perceived ease of handling IPTV without much effort can positively influence the perceived value of IPTV. In this regard, engineers and designers of IPTV should pay more attention to the user-friendly interface of IPTV. In addition, 'perceived playfulness (PP)' of IPTV is positively related to 'intention to use'. Flow, fun and entertainment have recently gained greater attention in the research concerned with information systems. Such attention is due to the changing features of information systems in recent years that combine the functional and leisure attributes. These results give practical implications to the design of IPTV that reflects not just leisure but also functional elements. This paper also investigates the relationship between 'perceived ease of use (PEU)' and 'perceived playfulness (PP).' PEU is positively related to pp. Audiences without fear can be attracted more easily to the user-friendly IPTV, thereby perceiving the fun and entertainment with ease. Practical implications from this finding are that, to attract more interest and involvement from the audience, IPTV needs to be designed with similar or even more user friendly interface. Of the factors related to 'intention to use', 'perceived usefulness (PU)' and 'perceived ease of use (PEU)' have greater impacts than 'perceived playfulness (PP).' Between PU and PEU, their impacts on 'intention to use' are not significantly different statistically. Managerial implications of this finding are that firms in preparation for the launch of IPTV service should prioritize the functions and interface of IPTV. This empirical paper also provides further insight into the ways in which firms can strategically allocate their limited resources so as to appeal to viewers, both current and potential, of IPTV.

RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때 전달선량의 정확성 평가 (Evaluation of the Accuracy for Respiratory-gated RapidArc)

  • 성지원;윤명근;정원규;배선현;신동오;김동욱
    • 한국의학물리학회지:의학물리
    • /
    • 제24권2호
    • /
    • pp.127-132
    • /
    • 2013
  • 환자 호흡할 때 흉 복부 내부에 있는 장기의 위치는 주기적으로 변한다. 이에 따라 방사선치료 동안 종양에 대한 선량불확도가 발생하게 되며, 불확도를 줄이기 위한 여러 방사선치료방법이 제시되고 있다. 호흡연동방사선치료는 특정 위상 또는 진폭에만 방사선을 조사하는 방법으로 불필요한 피폭선량은 줄일 수 있는 장점이 있지만 긴 치료 시간과 노력이 필요하다는 단점이 있다. 호흡연동방사선치료 중 회전세기조절방사선치료(respiratory gated Volumetric Modulated Arc Therapy, VMAT)는 다른 호흡연동치료시스템에 비해 치료 시간이 짧다는 장점이 있기 때문에 본 연구는 respiratory gated VMAT 치료 선량의 정확성을 검증하여 임상 적용의 적절성을 평가하고자 한다. 본 연구는 총 6개의 VMAT 치료계획(Eclipse, ver. 8.6, Palo Alto, USA)을 토대로 수행되었으며, 각각의 치료계획은 AAA 알고리즘을 이용해서 선량이 계산되었다. 환자의 호흡운동을 구현하기 위해 환자 테이블 위에 1차원운동팬텀이 사용되었으며, 영상 기반 추적 시스템(Real-time Position Management, RPM, Varian Medical Systems, Palo Alto, USA)을 통해 운동 주기 신호를 획득하였다. 또한, 2차원-이온함-배열(MatriXX, IBA, Germany) 측정기를 이용하여 특정 호흡 신호 위상에 따른 전달 선량을 측정하였다. 측정된 선량과 치료 계획된 선량을 정성적인 분석을 위해 상용화되어 있는 선량분석용 프로그램(I'mRT, IBA, Germany)을 통해 2차원 선량분포를 0에서 1사이의 감마지표(Gamma index) 비교 결과 모든 케이스에서 97% 이상의 일치함을 확인하였다. 따라서 호흡연동 회전세기조절 방사선치료는 호흡연동방사선치료의 단점인 시간적인 제약을 일정 부분 해소할 수 있었으며 2차원 선량분포 비교 결과 오차값 3%이내의 정확도에서 환자정도관리 수준을 만족하였고 임상적용이 가능함을 확인하였다.

켈로이드와 비후성 반혼에서 재발을 방지하기 위한 수술후 방사선치료의 효과 (Effects of Postoperative Radiation Therapy for Prevention of Keloids and Hypertrophic Scars)

  • 강기문;최일봉;김인아;장지영;신경섭
    • Radiation Oncology Journal
    • /
    • 제15권3호
    • /
    • pp.269-276
    • /
    • 1997
  • 목적 : 켈로이드와 비후성 반후에서 재발을 방지하기 위해 외과적 절제술후 방사선치료를 받은 환자를 대상으로 그에 대한 효과를 알아보고자 하였다. 방법 : 1987년 10월부터 1995년 4월까지 켈로이드로 수술후 방사선치료를 받은 106명의 환자 에서 167예를 대상으로 후향적 분석을 하였다. 켈로이드의 주된 발생원인으로는 수술이 83예$(49.2\%)$, 외상이 42예$(25.0\%)$ ear-piercing이 9예$(5.4\%)$, 화상이 9예$(5.4\%)$였다. 켈로이드의 위치별 분포로는 이개에 25예$(15.0\%)$, 그외 머리와 목이 81예$(48.5\%)$, 체간이 36예$(21.5\%)$, 사지가 25예$(15.0\%)$였다. 남자는 19명, 여자는 87명이였고 연령은 3세에서 70세였다(중앙값:32세). 방사선치료는 수술후 24시간 이태에 시행하였으며 6-8MeV의 전자선을 이용하여 총 조사선량은 400cGy에서 1900cGy까지 조사하였다(평균값: 1059cGy). 추적관찰 기간은 24개월에서 114개월 이었으며 중앙값은 49개월이었다. 결과 : 대상환자 106명의 환자에서 167예를 치료한 결과, 재발은 21예로 $12.6\%$의 재발율을 보였고, 1년 재발율은 $10.2\%$, 2년 재발율은 $11.4\%$였다. 재발된 병변에 있어서 수술후 12개월이 내에 재발된 경우는 전체의 $81\%$였다(17/21). 재발된 25예의 재발기간은 수술후 1개월에서 47개월까지였으며 평균재발기간은 9.6개월이였다. 재발된 부위를 살펴보면 이개에 2예$(1.2\%)$, 그외 머리와 목이 14예$(8.4\%)$, 체간이 4예$(2.4\%)$, 사지간 1예$(0.6\%)$로 나타났다. 재발에 영향을 미치는 예후인자에 연령. 성별, 분할조사 크기, 1회 조사량, 원인, 위치, 발생전 치료유무에 따라 분석한 결과 : 과거의 치료유무에서 치료경험이 없었던 군이 치료경험이 있었던 군보다 재발율이 낮았으며$(11.0\%\;vs.\;22.6\%)$ 과거와 치료유무만이 통계적인 유의성이 있었다(P=0.04). 치료에 따른 합병증으로 특이한 사항은 없었다. 결론 : 켈로이드와 비후성 반흔 환자에서 재발 발지를 위한 수술후 방사선치료는 비교적 안전하고 효과적이였다. 그러나 추후 수술후 방사선치료의 역할을 보다 더 정확히 평가하기 위해서는 비교 연구와 전향적인 연구가 필요할 것으로 사료된다.

  • PDF

탄소계 경질 박막의 연구 및 산업 적용 동향 (Trend in Research and Application of Hard Carbon-based Thin Films)

  • 이경황;박종원;양지훈;정재인
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.111-112
    • /
    • 2009
  • Diamond-like carbon (DLC) is a convenient term to indicate the compositions of the various forms of amorphous carbon (a-C), tetrahedral amorphous carbon (ta-C), hydrogenated amorphous carbon and tetrahedral amorphous carbon (a-C:H and ta-C:H). The a-C film with disordered graphitic ordering, such as soot, chars, glassy carbon, and evaporated a-C, is shown in the lower left hand corner. If the fraction of sp3 bonding reaches a high degree, such an a-C is denoted as tetrahedral amorphous carbon (ta-C), in order to distinguish it from sp2 a-C [2]. Two hydrocarbon polymers, that is, polyethylene (CH2)n and polyacetylene (CH)n, define the limits of the triangle in the right hand corner beyond which interconnecting C-C networks do not form, and only strait-chain molecules are formed. The DLC films, i.e. a-C, ta-C, a-C:H and ta-C:H, have some extreme properties similar to diamond, such as hardness, elastic modulus and chemical inertness. These films are great advantages for many applications. One of the most important applications of the carbon-based films is the coating for magnetic hard disk recording. The second successful application is wear protective and antireflective films for IR windows. The third application is wear protection of bearings and sliding friction parts. The fourth is precision gages for the automotive industry. Recently, exciting ongoing study [1] tries to deposit a carbon-based protective film on engine parts (e.g. engine cylinders and pistons) taking into account not only low friction and wear, but also self lubricating properties. Reduction of the oil consumption is expected. Currently, for an additional application field, the carbon-based films are extensively studied as excellent candidates for biocompatible films on biomedical implants. The carbon-based films consist of carbon, hydrogen and nitrogen, which are biologically harmless as well as the main elements of human body. Some in vitro and limited in vivo studies on the biological effects of carbon-based films have been studied [$2{\sim}5$].The carbon-based films have great potentials in many fields. However, a few technological issues for carbon-based film are still needed to be studied to improve the applicability. Aisenberg and Chabot [3] firstly prepared an amorphous carbon film on substrates remained at room temperature using a beam of carbon ions produced using argon plasma. Spencer et al. [4] had subsequently developed this field. Many deposition techniques for DLC films have been developed to increase the fraction of sp3 bonding in the films. The a-C films have been prepared by a variety of deposition methods such as ion plating, DC or RF sputtering, RF or DC plasma enhanced chemical vapor deposition (PECVD), electron cyclotron resonance chemical vapor deposition (ECR-CVD), ion implantation, ablation, pulsed laser deposition and cathodic arc deposition, from a variety of carbon target or gaseous sources materials [5]. Sputtering is the most common deposition method for a-C film. Deposited films by these plasma methods, such as plasma enhanced chemical vapor deposition (PECVD) [6], are ranged into the interior of the triangle. Application fields of DLC films investigated from papers. Many papers purposed to apply for tribology due to the carbon-based films of low friction and wear resistance. Figure 1 shows the percentage of DLC research interest for application field. The biggest portion is tribology field. It is occupied 57%. Second, biomedical field hold 14%. Nowadays, biomedical field is took notice in many countries and significantly increased the research papers. DLC films actually applied to many industries in 2005 as shown figure 2. The most applied fields are mold and machinery industries. It took over 50%. The automobile industry is more and more increase application parts. In the near future, automobile industry is expected a big market for DLC coating. Figure 1 Research interests of carbon-based filmsFigure 2 Demand ratio of DLC coating for industry in 2005. In this presentation, I will introduce a trend of carbon-based coating research and applications.

  • PDF

자궁경부암 환자의 근접치료시 재현성 평가 (Reproducibility of Applicator Position with High dose rate brachytherapy in uterine cervical cancer)

  • 김종화;손정혜;정칠;김미화
    • 대한방사선치료학회지
    • /
    • 제15권1호
    • /
    • pp.29-33
    • /
    • 2003
  • I. 목적 외부방사선 치료와 같이 근접치료 시에도 재현성을 평가하기 위해 bone의 위치와 tandem, ovoid 간의 거리를 측정하여 치료 setting의 재현성을 평가함으로써 자궁경부암 환자의 근접치료시 치료의 재현성을 평가하고자 하였다. II. 대상 및 방법 1999년부터 2001년 10월까지 본원을 내원해서 근접치료를 시행한 자궁경부암 환자중 tandem, ovoid을 사용한 52명을 대상으로 근접치료시 촬영한 film(환자1명당 3회촬영)을 가지고 측정하였다. Os을 기준으로 환자의 center축을 잡고 tandem, ovoid의 위치와 pubic symphysis, sacrum, coccyx등과의 거리를 각각 측정하여 치료 setting의 재현성을 평가하였다. III. 결과 환자 52명에 대한 tandem, ovoid의 위치와 pubic symphysis, sacrum, coccyx등과의 거리에 대한 표준 편차 결과는 다음과 같은 분포로 나타났다. 1) 각 tandem angle 의 표준편차는 $0^{\circ}{\sim}2.89^{\circ}$이다. 2) pubic symphysis에서 Os까지의 높이는 $0cm{\sim}0.79cm$ 3) sacrum에서 tandem tip까지의 거리는 $0cm{\sim}0.9cm$ 4) Os level에서 coccyx까지의 거리는 $0.06cm{\sim}0.76cm$ 5) ovoid tip에서 Os까지의 거리는 오른쪽은 $0cm{\sim}0.53cm$ 6) ovoid tip에서 Os까지의 거리는 왼쪽은 $0cm{\sim}0.45cm$ 7) 첫번째 source위치에서 ovoid사이의 거리는 $0cm{\sim}0.36cm$ 8) tandem에서 ovoid tip까지의 거리는 $0cm{\sim}0.31cm$ IV. 결론 자궁경부암 치료에 있어 근접치료는 중요한 치료 방법이다. 환자 치료간에 재현성을 평가해본 결과 대체로 만족 할 만한 수치를 보였으며 고선량율 근접치료에서 재현성 평가는 중요할 것이고 계속적으로 평가할 필요가 있을 것이다.

  • PDF

악성 기도 폐쇄에 대한 기관내 근접 조사 방사선치료의 단기 임상 경험 (Short-term Results of Endobronchial Brachytherapy for Malignant Airway Obstructions)

  • 안용찬;임도훈;최동락;김문경;김대용;허승재;김호중;정만표;권오정;이종헌
    • Radiation Oncology Journal
    • /
    • 제14권4호
    • /
    • pp.299-306
    • /
    • 1996
  • 목적 : 주요 기도의 악성 종양으로 인한 호흡기 증상은 적절한 조치를 취하지 않을 경우 때로는 환자의 생명을 위협할 정도로 위급한 경우가 있으며 환자의 삶의 질을 저하시키는 주요 원인이 된다. 이러한 호흡기 증상의 완화를 위하여 적용한 기관지 내시경을 이용한 고선량율 기관내 근접 조사 방사선차료의 단기 임상 관찰 결과를 보고하고자 한다. 대상 및 방법 : 1994년 12월부터 1996년 3월까지 원발성 또는 전이성 폐암으로 인한 기도폐쇄 와 이로 인한 주요 호흡기 증상이 있는 25명의 환자들에 대하여 고선량율 기관내 근접 조사 방사선치료를 시술하였다. 원발 병소는 비소세포성 폐암이 21례 ($84\%$), 원발성 기관암이 3례($12\%$), 재발된 식도암이 1례였다. 20명의 환자들에 대하여는 외부 조사 방사선치료를 병행하였으며, 급성 기도 폐쇄로 위급한 증상을 호소하였던 6명의 환자에 대하여는 응급 기관내 Laser 소작술을 먼저 시행하였다. 기관내 근접 조사 방사선치료는 모든 환자에서 각 3회씩 시행하도록 예정하였으며 모두 70회의 치료를 시행하였다. 결과 : 기관내 근접 조사 방사선치료의 전후로 조사한 주요 호흡기 증상은 기침, 호흡곤란, 각혈, 폐쇄성 폐렴이 각각 $88\%$ (22/25), $96\%$ (22/23), $100\%$ (15/15), $100\%$ (9/9)에서 호전되었으며, 환자의 일반 활동도 (ECOG performance score)는 전체 환자의 $56\%$에서 호전되었고 악화된 경우는 없었다. 관찰 기간 동안 15명이 사망하였으며 치료 개시로부터 사망까지 기간의 중앙값은 4개월 (범위: 1개월$\~$17개월) 이었고 10명의 생존자들의 생존 기간의 중앙값은 9개월 (범위: 5개월$\~$19개월)이었다. 치료 후 1년 이상 생존한 환자는 5명이었으며 이들 모두에선 원발 병소의 완전 관해를 확인할 수 있었다. 사망자들은 모두 원발 및 전이 병소의 진행으로 인한 경우였다. 대량 각혈로 사망한 경우는 4명이었으며 이 중 3명은 응급 기관내 Laser 소작술을 선행하였던 경우였다. 결론 : 기관지 내시경을 이용한 기관내 근접 조사 방사선 치료는 기도의 악성 병변시 호흡기 증상 및 환자의 활동도를 호전시키는 데 매우 효과적인 치료 방법이다. 저자들의 관찰 경험을 바탕으로 하여 기관내 근접 조사 방사선치료는 근치적 방사선치료의 국소 추가 방사선 조사의 한 방법으로 적용할 수 있을 것으로 판단된다.

  • PDF

64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소 (Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols)

  • 김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.299-306
    • /
    • 2009
  • MDCT의 시간분해능 향상과 등방성 해상능(isotrophic resolution) 영상의 획득, 그리고 지능적인 심전도 동조를 바탕으로 하여 심혈관 질환의 효과적인 진단검사로 인정받고 있는 후향적 심전도 동조화(retrospective ECG gating) 하의 coronary CT angiography는 상대적으로 많은 환자선량을 제공함으로 인해 우수한 진단방법으로서의 장점을 반감시키고 있다. 이에 각 장치 제조사에서는 환자선량을 감소시키는 방법의 연구가 활성화되어 왔으며, 이의 일환으로 지능적인 cardiac dose modulation 기술과 전향적 심전도 동조화(prospective ECG gating)를 사용한 sequential scan이 도입되고 있다. 이에 본 연구에서는 64 채널 MDCT에서 54 kg, 163 cm인 여성 인체모형팬텀을 대상으로 하고 형광유리선량계를 사용하여 후향적 심전도 동조화 하의 coronary CT angiography 프로토콜에서 환자선량의 정량적 평가와 환자선량 감소를 위해 본원에서 선택적으로 적용하고 있는 5가지 검사 프로토콜을 적용하였을 경우의 effective dose와 중요 부위의 organ dose를 측정 비교하여 다음과 같은 결과를 얻었다. 1) Dose modulation없이 120 kVp와 210 mAs의 노출조건으로 retrospectively ECG gated helical scan으로 시행한 conventional coronary CT angiography 프로토콜의 effective dose는 17.8 mSv였으며, 심장의 organ dose는 103.8 mGy였다. 2) 관전압을 120 kVp에서 100 kVp로 낮추었을 경우 effective dose는 11.0 mSv로 conventional coronary CT에 비해 38.2%가 감소하였으며, 심장은 67.3 mGy로 45.2%가 감소하였다. 3) Cardiac dose modulation을 적용한 경우 effective dose는 13.3 mSv로 conventional coronary CT에 비해 25.3%가 감소하였으며, 심장은 80.0 mGy로 22.9%가 감소하였다. 4) 100 kVp의 저관전압과 cardiac dose modulation을 적용한 경우 effective dose는 8.1 mSv로 conventional coronary CT angiography에 비해 54.5%가 감소하였으며, 심장은 49.5 mGy로 52.3%가 감소하였다.

  • PDF