• 제목/요약/키워드: Main Power Transformer

검색결과 192건 처리시간 0.024초

전력변환장치의 고조파 영향 및 연구동향 (Harmonic Effects and Consideration in Power Converter and Component)

  • 조성준;김태완;우명호;서광덕
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.467-470
    • /
    • 2001
  • Power electronic converters generate the harmonic voltage and current, and these harmonics have the harmful effects on the various components. For example, passive components such as capacitor and inductor, transformer, motor and other components are mainly affected in the power electronic system. Thus, the design and manufacturing of the power converters, which have the harmonic-free or mitigation strategies, are required. In particular, the lifetime and durability of these components are main requirement for enhancing the overall stability of the system. So, in this paper, the harmonics-related problems to the neighbouring components and mitigation research trends are presented.

  • PDF

A New Dual-Active Soft-Switching Converter for an MTEM Electromagnetic Transmitter

  • Wang, Xuhong;Zhang, Yiming;Liu, Wei
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1454-1468
    • /
    • 2017
  • In this study, a new dual-active soft-switching converter is proposed to improve conversion efficiency and extend the load range for an MTEM electromagnetic transmitter in geological exploration. Unlike a conventional DC/DC converter, the proposed converter can operate in passive soft-switching, single-active soft-switching, or dual-active soft-switching modes depending on the change in load power. The main switches and lagging auxiliary switches of the converter can attain soft-switching over the entire load range. The conduction and switching losses are greatly reduced compared with those of ordinary converters under the action of the cut-off diodes and auxiliary windings coupled to the main transformer in the auxiliary circuits. The conversion efficiency of the proposed converter is significantly improved, especially under light-load conditions. First, the working principle of the proposed converter is analyzed in detail. Second, the relationship between the different operating modes and the load power is given and the design principle of the auxiliary circuit is presented. Finally, the Saber simulation and experimental results verify the feasibility and validity of the converter and a 50 kW prototype is implemented.

분산전원이 연계된 배전계통에 있어서 선로전압조정장치(SVR)의 전압제어 개선방안 (Improvement Method of SVR Control in Power Distribution System Interconnected Distributed Generator)

  • 이현옥;허재선;김병기;노대석;김재철
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.224-229
    • /
    • 2014
  • This paper presents the novel voltage control method in power distribution system with distributed generators. The voltage in distribution systems is regulated by Under Load Tap Changer(ULTC) of substation and pole transformer of primary feeders. Recently, Step Voltage Regulator(SVR) is getting located at distribution feeders to regulate effectively voltage of primary feeders. But the effectiveness of SVR decreases due to independent operation between SVR and ULTC, and also the existing Line Drop Compensator(LDC) method considering the distributed generators may be not able to regulate the proper voltage in a permissible range. Thus, this paper presents a optimal voltage control algorithm of SVR by using the secondary voltage data of main transformer in substation.

교류쵸퍼와 보조변압기를 사용한 직렬보상형 교류전압제어장치 (Series Compensated AC Voltage Regulator using AC chopper with Auxiliary Transformer)

  • 류홍제;김종수;임근희
    • 전력전자학회논문지
    • /
    • 제8권5호
    • /
    • pp.463-467
    • /
    • 2003
  • 본 논문에서는 교류쵸퍼와 직렬보상변압기로 구성되는 교류전압제어장치에 대하여 연구한다. 먼저, 교류쵸퍼와 직렬보상변압기로 구성되는 기본적인 교류전압제어장치로 출력전압을 입력전압에서 10-20%정도 강압할 수 있는 형태의 강압형 교류전압 제어장치를 제안하고 기본동작원리 및 이의 안전한 운전을 위한 PWM 발생과 초기시퀀스로직을 제시하였다. 또한 이로부터 입력전압변동에 무관하게 일정 출력전압을 발생시키기 위한 자동전압제어장치(AVR: Automatic Voltage Regulator)로 사용가능한 두가지 형태의 직렬보상형 교류전압제어장치를 제안하고 동작원리를 기술하였다. 특히, 입력전압과 반대방향의 극성의 전압을 발생시킬 수 있는 새로운 형태의 양방향 교류쵸퍼를 제안하고, 이의 안전한 운전을 위한 PWM 발생을 위한 스위칭 패턴을 제시하였다. 제안된 교류전압제어회로의 경우 다양한 실험을 통하여 전력절감을 목적으로 하는 강압형 교류전압제어장치와 자동전압조절기의 용도로 효과적으로 적용될 수 있음을 확인하였다.

345kV 승압용 변전소의 뇌격에 의한 이상전압 해석 (Analysis of Transient Voltage by Lightning Stroke at 345kV Step-up Transformer)

  • 조만영;신호전;허재선;김재철
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.95-101
    • /
    • 2012
  • Typically, large scale power generation facilities are linked to 345kV transmission line through a step-up transformer. If the value of transient voltage by generating lightning stroke is large more than electric equipment's BIL, devices insulation is destroyed. LA(Lighting Arrester) is used as a main means of prevention. However, the installation of LA takes the constraints of installation place and expensive installation costs. Therefore, we need to carefully study whether installation of installation can be omitted and the most efficient place of installation. In this paper, we simulated the transient voltage detected by lightning stroke at each equipments in the 345kV transmission power grid by using EMTP-RV program.

리모트 프라즈마 전원용 하프 브리지 인버터의 운전 특성 (A Operation characteristics of the HB inverter for Remote Plasma Source)

  • 김수석;원충연;최대규;최상돈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.611-615
    • /
    • 2003
  • In this paper, a operation characteristics and analysis of the HB(half bridge) inverter for remote plasma system are studied. the remote plasma system is cleaning system for the chemical vapor deposition (CVD) chamber in semiconductor processing. The remote plasma system is powered by the RF generator The main power stage of the RF generator is used for the HB PWM inverter with an low pass filter in the secondary circuit of the transformer. The detailed mode analysis of HB invertor was described. The operation characteristics of Remote Plasma Source are verified by simulation and experimental results.

  • PDF

강체전차선로의 특성을 고려한 급전시스템에서 이선에 따른 철도차량 전력변환장치에 대한 특성에 관한 연구 (A Study on Characteristic of Power Conversion System in Electric Railway Vehicle According to Contact Loss in Feeding System Considering Characteristic of Rigid Bar)

  • 정노건;이환;김재문
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.520-525
    • /
    • 2016
  • In this paper, Characteristic of power conversion unit of a railway vehicles according to contact loss in feeding system that applied impedance of rigid conductor is analyzed. It applied impedance of rigid bar in modeling of electric railway system. Railway vehicles are performed of modeling based on the performance of the electric railway vehicle. Effects of the contact loss in the power conversion unit were analyzed via main transformer of railway vehicle, the input and output voltage characteristics of the converter through contact loss was generated after linking the vehicle with feeding system.

발전소내 스위치야드 및 주변압기간 연결선로의 적정 피뢰기 위치 선정 (A STUDY ON EFFECTIVE APPLICATION OF SURGE ARRESTER BETWEEN THE SWITCHYARD AND MAIN TRANSFORMER IN POWER PLANT)

  • 이흥찬;함영수;정기수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.503-505
    • /
    • 1995
  • The surge arrester plays a vital role in the protection of substation against transient overvoltages resulting from lightning surges and system switching operations. The proper selection and application of the surge arrester is an integral part of the process of substation equipment insulation level selection. The paper outlines the basic consideration in modeling the lightning stroke, the surge arrester, and the system to be protected. The paper discusses the results of various cases simulated using the alternative transient computer program to evaluate the separation effects.

  • PDF

배전자동화시스템 적용을 위한 경제성 평가 (Economic Evaluation far the Application of the Distribution Automation System)

  • 홍순학;하복남;김호용;정경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.36-38
    • /
    • 1993
  • This study considers the economic aspect of the distribution automation system, which is the decision-making criteria of the electric utilities for the investment. The feeder automation candidate region is divided into two types of the urban and the rural. The total investment cost of the feeder automation for each type is estimated. The annual cost, is also estimated, by finding the fixed charge rate. To compare the annual cost and the economic effect cost, for the investment decision-making, the costs are quantitatively estimated on the following effects : the manpower replacement, the outage cost saving, the main transformer utilization improvement, the feeder utilization improvement, and the line loss reduction.

  • PDF

변압기 Local Unit의 IEC61850 Logical Node 설계 (Design of New IEC 61850 Logical Node about Main Transformer Local Unit)

  • 최대희;김명회;양항준;최영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.511-512
    • /
    • 2007
  • 변전소 자동화 시스템은 변전소 내의 주요 전기적 데이터들을 DB화 하여 그 트렌드 및 이벤트 내역을 관리하고 각종 제어를 수행하고 상태를 감시하는 시스템이다. 현재 전 세계적으로 IEC 61850 프로토콜을 적용하고 그 목적에 맞게 Interoperability를 구현하려는 노력이 진행되고 있으며 이에 맞추어 변전소 및 Utility에 적용되는 많은 시스템들이 IEC 61850의 적용에 박차를 가하고 있는 상황이다. 이에 따라 변전소 내의 주요기기중의 하나인 주 변압기에 설치되어 변압기의 상태를 감시하고 관리하는 IED인 변압기 Local Unit에 사용할 수 있는 새로운 IEC 61850 Local Unit의 Logical Node를 설계한다.

  • PDF