• 제목/요약/키워드: Main Power Transformer

검색결과 192건 처리시간 0.023초

피뢰기 누설전류 분석장치를 이용한 ZnO 피뢰기의 누설전류 변화 분석 (The Leakage Current Analysis of ZnO Arrester Using Leakage Current Dete)

  • 김영춘;문선호;오정환;김재철;이영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1082-1084
    • /
    • 1998
  • In this paper, we developed a diagnosis device for ZnO arrester to detect on-line leakage current and acquire data from the power distribution system. The arrester is important power equipment used in power transmission and distribution systems to protect the generator and the main transformer from surge and overvoltage. First of all we developed a diagnosis device for ZnO arrester leakage current. And then we detect the total leakage current by the developed device without disconnecting the arrester ground wire and analysis the 3rd order harmonic by Fast Fourier Transform(FFT) to diagnose the ZnO arrester deterioration. With measuring the total current and the resistive current of power distribution system in operation, we analysis the trend of resistive current component in the total leakage current. We expect the result will be promote the method to protect electrical utility and customer from accident.

  • PDF

에너지 절감을 고려한 캠퍼스 마이크로그리드에서 선형 전압제어 방식의 AVR을 이용한 CVR의 적용 (Application of Conservation Voltage Reduction using Automatic Voltage Regulator of Linear Voltage Control in Campus Microgrid with Power Consumption Reduction)

  • 임일형;이명환;신용학
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1039-1046
    • /
    • 2017
  • Campus microgrid is designed and built by considering not only power generation but also power consumption management as connected microgrid type because the main goal of the campus microgrid is to save power consumption costs. There are many functions to achieve the goal and they are mainly to use generation-based functions such as islanding operation for peak management and for emergency events. In power distribution operation, Conservation Voltage Reduction (CVR) is applied in order to reduce power consumption. The CVR is defined as a function for load consumption reduction by voltage reduction in order to reduce peak demands and energy consumption. However, application of CVR to microgrid is difficult because the microgrid cannot control a tap of transformer in a substation and the microgrid normally is not designed with phase modifying equipment like a step-voltage-regulator which can control voltage in power distribution system operation. In addition, an impact of the CVR is depended on load characteristics such as a normal load, a rated power, and synchronous motors. Therefore, this paper proposes an application of CVR using linear voltage control based AVR in campus microgrid with power consumption reduction considering characteristics of load and component in the microgrid. The proposed system can be applied to each buildings by a configuration of power distribution cables; and the application results and CVR factor are presented in this paper.

적층 배열형상에 따른 BSCCO 적층선재의 자화손실 특성 수치해석 및 측정 (Numerical Analysis and Measurement of Magnetization Loss in BSCCO Multi-stacked Conductor According to Stacking Geometry)

  • 박명진;임형우;이광연;차귀수;이지광
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권2호
    • /
    • pp.83-88
    • /
    • 2006
  • AC loss is one of the main research area in AC power application using high temperature superconductor(HTS), such as HTS transformer, HTS current limiter and HTS cable, because it is closely related to efficiency, economic estimation and design of power device. A lot of research for various arrangements of HTS tapes have been performed to increase a capacity of transport current because single HTS tape can not satisfy the demanded current capacity in HTS power application. In this paper, we studied magnetization loss by different several arrangements of BSCCO tapes such as Edge-to-Edge type, Face-to-Face type and Matrix type through numerical analysis by 2D-FEM and measurement. As a result, we got the result that the magnetization loss of Face-to-Face type arrangements was lower than those of other arrangement types under the conditions of the same stacking number. We think that the result was due to shield effect by demagnetization of adjacent HTS tapes which are located face to face.

출력 전력 백-오프 기반 비대칭 도허티 전력 증폭기 (Output Power Back-Off (OPBO) Based Asymmetric Doherty Power Amplifier)

  • 전상현;장동희;김지연;김종현
    • 한국ITS학회 논문지
    • /
    • 제9권2호
    • /
    • pp.51-59
    • /
    • 2010
  • 본 논문에서는 입력신호의 Peak to Average Power Ratio (PAR) 에 따라 원하는 출력전력 백-오프 (Output Power Back-Off, OPBO) 구간에서 최적의 효율특성을 가지는 반전 타입의 비대칭 도허티 전력증폭기의 설계 방법을 제안하였다. 원하는 OPBO 구간에서 비대칭 도허티 전력증폭기의 최적 효율특성을 얻기 위해 주 증폭기와 피킹 증폭기의 피크 전력비를 결정하였고 피크 전력비에 따른 $90^{\circ}$ 임피던스 변환기의 정확한 임피던스 값을 도출 하였다. 또한 비대칭 도허티 전력증폭기 설계시 최적의 성능을 얻기 위해 오프셋 라인의 길이와 전력 분배비를 계산하였다. 측정결과, 비대칭 도허티 전력증폭기는 CDMA 2000 1x 3-FA 테스트 신호에 대해서 평균 출력 전력 48.7 dBm에서 40%의 전력 효율과 -35 dBc의 인접 채널전력비를 얻었다.

교류쵸퍼를 사용한 3상 강압형 전압제어장치 (A 3-phase step-down voltage regulator using AC choppers)

  • 류홍제;김종수;임근희;김득수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1075-1077
    • /
    • 2002
  • This paper describes a three-phase step-down AC voltage regulator using AC chopper and auxiliary transformer which is series connected with main input. It has many advantages such as fast voltage control, high efficiency and low THD. The operation principle and PWM method of the proposed regulator are described. Experimental results show that it can be used as step-down AC voltage regulator for power saving purpose very efficiently.

  • PDF

초고압 현수애자의 Pin 형상에 따른 응력해석 (The Temperature Distribution Analysis and Temperature Rise Test of Pole Mold Transformer)

  • 조한구;박기호;한세원;윤문수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.155-157
    • /
    • 2001
  • Various types suspension insulators made of toughness glass or porcelain are used in the power transmission. And, Insulators are continually subject to mechanical and electrical stresses which depend on the characteristics of the line. The main factor that influence the increase in reliability of insulators. In operation is the capacity of the design to withstand the certain load over a long time, the mechanical strength of the insulators. This paper describes the results of a study on the stress analysis of suspension insulator based on the finite element analysis using NASTRAN. And, the mechanical strength was evaluated through such as kinds of pin type.

  • PDF

광대역 출력을 가지는 전기자동차 배터리 충전용 AC/DC 컨버터 (Wide Output Range AC/DC Converter for Rechargeable Battery of Electric Vehicle)

  • 김영일;김홍중;전범수;박귀철;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.73-74
    • /
    • 2016
  • This paper proposes a wide output range AC/DC converter for a rechargeable battery of electric vehicle. In the proposed wide output range AC/DC converter for rechargeable battery of electric vehicle, the main transformer in the DC/DC stage is divided by two. Therefore, if the switch is connected to the middle tap, then half of the maximum voltage is applied. Otherwise, it can be applied the full range of the high voltage by connecting the switch to the whole tab. And also, it is designed to have a wide output voltage range by applying Vin/2 made by changing the full-bridge to half-bridge by using the bridge change switch of the input stage. As it can be supplied the wide range output voltage with a single module, it has the advantage of space utilization and cost reduction effect.

  • PDF

영전압/영전류 스위칭을 이용한 고효율의 직렬 접속 배터리 전압 밸런싱 방법 (A High Efficiency Zero Voltage/Zero Current Transition Converter for Series Connected Battery Cell Equalization)

  • 김태훈;박남주;현동석;김래영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.26-27
    • /
    • 2011
  • This paper focuses on the zero-voltage/zero current transition voltage equalization circuit for the series connected battery cell. By adding auxiliary resonant cells at the main switching devices such as MOSFET or IGBT, zero current switching is achieved and turned off loss of switching elements is eliminated and by the voltage/second balancing of the inductor, zero voltage switching can be applied to switching element. Transformer coupling between battery cells and ZVZCT (Zero Voltage Zero Current Transition) switching method allow the fast balancing speed and high frequency operation, which reduces the size and weight of the circuit. The validity of the battery equalization is further verified using simulation involving four lithium-ion battery cell models.

  • PDF

컴퓨터 부하의 직렬 동조 필터 적용에 의한 고조파 및 순간전압강하 영향에 관한 연구 (A Study on the Harmonics and Voltage Sags Effect by the Series Resonant Filter Application for Personal Computer Loads)

  • 서범관;김경철;이근준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.460-461
    • /
    • 2006
  • Computer Loads can be found in all of modern society. The switching mode power supplies used in personal computers are major sources of harmonic currents. Harmonic currents can cause lots of harmonic problems such as disruption in computer performance. A series resonant filter is very effective in harmonic reduction for personal computer loads. Voltage sags are short duration reductions in rms voltage. The main causes of voltage sags are faults, motor starting, and transformer energizing. Personal computers are another example of devices sensitive to voltage sags. A serious voltage sag at the terminals way lead mis-operation of the equipment. This paper presents an in depth analysis to evaluate the effect of harmonics reduction based on the IEC 61000-3-2 and the effect of voltage sag using ITI curve by applying a series resonant filter for personal computer loads.

  • PDF

포화인덕터를 이용한 일정주파수제어 포워드 공진형 컨버터 (A constant frequency controlled forward AVS-MRC using a saturable inductor)

  • 안태영
    • 전자공학회논문지S
    • /
    • 제34S권1호
    • /
    • pp.145-153
    • /
    • 1997
  • This paper proposes a constant frequency controlled forward zero voltage switching multi resonant converter (ZVS-MRC) which operates with a fixed duty ratio. The proposed converter is obtained from a conventional forward ZVS-MRC by placing a saturable core in parallel with the secondary side of the transformer. Experimental results are presented for a proposed converter which operates at 1.5MHz switching frequency with an output power of 50W (5V/10A). The merits of the proposed converter include ; 1) reduced voltage stress to the main switch compared with the conventional counterpart, 2) ease on designing the magnetic components including EMI and output filter, and 3) simple control scheme.

  • PDF