Analysis of Key Parameters for Inductively Coupled Power Transfer Systems Realized by Detuning Factor in Synchronous Generators

  • Liu, Jinfeng;Li, Kun;Jin, Ningzhi;Iu, Herbert Ho-Ching
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1087-1098
    • /
    • 2019
  • In this paper, a detuning factor (DeFac) method is proposed to design the key parameters for optimizing the transfer power and efficiency of an Inductively Coupled Power Transfer (ICPT) system with primary-secondary side compensation. Depending on the robustness of the system, the DeFac method can guarantee the stability of the transfer power and efficiency of an ICPT system within a certain range of resistive-capacitive or resistive-inductive loads. A MATLAB-Simulink model of a ICPT system was built to assess the system's main evaluation criteria, namely its maximum power ratio (PR) and efficiency, in terms of different approaches. In addition, a magnetic field simulation model was built using Ansoft to specify the leakage flux and current density. Simulation results show that both the maximum PR and efficiency of the ICPT system can reach almost 70% despite the severe detuning imposed by the DeFac method. The system also exhibited low levels of leakage flux and a high current density. Experimental results confirmed the validity and feasibility of an ICPT system using DeFac-designed parameters.

초고압 변전기기의 예방진단 및 종합 자동화 (The Preventing and Diagnosis of Ultra High Voltage Substation Devices and Combination with An Automation System of A Substation)

  • 양항준;김경근;김성식;유정식;김홍석;이학성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.275-277
    • /
    • 2001
  • In this paper a preventative and diagnostic system for high and ultra high voltage electric power transmission apparatus is proposed to secure substation normal operation. The proposed system consists of monitoring sub-system and diagnostic sub-system, which are mainly for GIS and main transformer, and the system will be applied for newly established 765kV class substation in Korea. Some guideline for combination with substation control system are presented, and engineering solution as an improved substation automation system is also proposed.

  • PDF

154kV 주변압기용 가스차단기(GCB) 소손에 따른 원인규명과 항구대책 분석 (A Study on the cause and permanent measures on trouble of the GCB for the Main Tr. of Voltage, 154kV)

  • 전규남;장문성;옥광석;남궁혁;안주훈;정재원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.285-286
    • /
    • 2008
  • The Gas Circuit Breaker for the Main Transformer of voltage, 154kV at the ist Hapcheon hydraulic power station, break down by the falling of a thunderbolt from now, let's improve the efficiency on the maintenance of generating equipment by studying about the cause and the method for this problem.

  • PDF

열차운행 안정화를 위한 주회로 기기의 고조파 제한장치 개발에 관한 연구 (A Study on the Development of Harmonic Limit Device for Stabilizing Main Circuit Equipment of Train)

  • 김성준;채은경;강정원
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제8권6호
    • /
    • pp.853-861
    • /
    • 2018
  • 본 논문에서는 전기철도차량이 운행할 때 이상 전압상승에 의한 문제점을 해결할 수 있는 고조파 제한장치의 적용을 제안한다. 운행 중 열차에 전력을 공급하는 교류가선은 25kV/60Hz의 전기를 공급하기 위하여 사용되지만 철도차량 전기장치의 기술발전에 따라 점차 가선에 포함되는 고조파의 크기 및 주파수의 변형이 다양해지고 있다. 최근 열차안전운행에 심각한 문제가 되고 있는 주회로 기기인계기용변압기(Potential Transformer, PT)의 파손이나 주변압기 등의 열손증가는 가선 전원의 고조파로 인한 순간적인 무효전류의 증가로 생기는 현상이다. 주회로 기기의 저주파형 트랜스포머로 고주파수 성분이 유입되면 트랜스 코어의 히스테리시스에 의한 철손 증가 및 기생 커패시턴스에 흐르는 전류가 증가하므로 발열이 발생하게 된다. 이러한 문제 해결을 위해 최근 시퀀스의 조정으로 전력변환 장치의 인위적인 NOTCH OFF가 적용되었다. 그러나, OFF 신호를 받아 제어하는 방식은 지상과 차상 장치의 상호작용으로 동작하므로 불량 발생 시 무효화 되며, 실제 사고가 발생되고 있다. 따라서, 근본적인 문제해결을 위한 방법으로 고조파 전류가 가급적 변압기에 유입되지 않도록 하는 것이 필요하며, 고조파 전류의 유입으로 인해 빈번하게 발생되고 있는 열차사고를 방지하고 안전한 운행을 위해 열차의 실험 분석과 고조파 제한장치의 시뮬레이션을 통한 장치의 타당성 검증을 위한 연구를 수행하였다.

전기철도용 축소형 전력품질 보상설비에 대한 모델링 및 시뮬레이션 (A modeling and simulation for a Small-Scaled Power Quality Compensating Equipment of Electrical Railway)

  • 강문호;김주락;한문섭
    • 한국철도학회논문집
    • /
    • 제10권2호
    • /
    • pp.96-102
    • /
    • 2007
  • This paper presents a study on the control of a power quality compensating equipment of electrical railway built in small-scaled to preliminary research. Because this compensating equipment is very complicated power electronics system, consisting of a scott transformer as a power source, four single phase inverters interconnected with DC-link capacitors and various electrical apparatuses, multiple controllers and control algorithms with high performance and reliability are needed. The major function of the compensating equipment is to manage reactive and active powers by using the four single phase inverters, so, the main control effort is focused on the power flow control which realized through the decoupling current control of the four inverters. Overall control system is designed with object oriented and analyzed on a Simulink window. The simulation results show that the design scheme is very effective for a complicated control system and the proposed controller has good performance.

The Design and Implementation of a Control System for TCSC in the KERI Analog Power Simulator

  • Jeon, Jin-Hong;Kim, Kwang-Su;Kim, Ji-Won;Oh, Tae-Kyoo
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권3호
    • /
    • pp.129-133
    • /
    • 2004
  • This paper deals with the design and implementation of a TCSC (Thyristor Controlled Series Capacitor) simulator, which is a module for an analog type power system simulator. Principally, it presents configuration of controller hardware/software and its experimental results. An analog type power system simulator consists of numerous power system components, such as various types of generator models, scale-downed transmission line modules, transformer models, switches and FACTS (Flexible AC Transmission System) devices. It has been utilized for the verification of the control algorithm and the study of system characteristics analysis. This TCSC simulator is designed for 50% line compensation rate and considered for damping resister characteristic analysis. Its power rate is three phase 380V 20kVA. For hardware extendibility, its controller is designed with VMEBUS and its main CPU is TMS320C32 DSP (Digital Signal Processor). For real time control and communications, its controller is applied to the RTOS (Real Time Operation System) for multi-tasking. This RTOS is uC/OS-II. The experimental results of capacitive mode and inductive mode operations verify the fundamental operations of the TCSC.

PI and Fuzzy Logic Controller Based 3-Phase 4-Wire Shunt Active Filters for the Mitigation of Current Harmonics with the Id-Iq Control Strategy

  • Mikkili, Suresh;Panda, Anup Kumar
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.914-921
    • /
    • 2011
  • Commencing with incandescent light bulbs, every load today creates harmonics. Unfortunately, these loads vary with respect to their amount of harmonic content and their response to problems caused by harmonics. The prevalent difficulties with harmonics are voltage and current waveform distortions. In addition, Electronic equipment like computers, battery chargers, electronic ballasts, variable frequency drives, and switching mode power supplies generate perilous amounts of harmonics. Issues related to harmonics are of a greater concern to engineers and building designers because they do more than just distort voltage waveforms, they can overheat the building wiring, cause nuisance tripping, overheat transformer units, and cause random end-user equipment failures. Thus power quality is becoming more and more serious with each passing day. As a result, active power filters (APFs) have gained a lot of attention due to their excellent harmonic compensation. However, the performance of the active filters seems to have contradictions with different control techniques. The main objective of this paper is to analyze shunt active filters with fuzzy and pi controllers. To carry out this analysis, active and reactive current methods ($i_d-i_q$) are considered. Extensive simulations were carried out. The simulations were performed under balance, unbalanced and non sinusoidal conditions. The results validate the dynamic behavior of fuzzy logic controllers over PI controllers.

변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구 (A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer)

  • 김도현;조남욱;윤충호;박필용;박근성
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.53-62
    • /
    • 2017
  • 경제 및 산업의 원천 에너지원인 전력은 생산과 소비의 지역적 상이함으로 장거리 수송을 필수로 하며, 다중환상망(Multi-loop) 형식의 송배전계통으로 전력을 공급한다. 실질적 사용에 앞서, 변전소내 변압기를 통해 변전과정을 거쳐 각 사용처의 특성을 고려하여 전력공급이 이루어지고 있으며 변압기는 본체, 권선, 절연유, 부싱등의 구조로 결합되어 있다. 변전소에서 발생하는 변압기화재는 가구와 상업시설등에 전기공급을 중단시키고 각종 안전사고를 발생시키는 1차 손실뿐만 아니라 2차적으로 경제 손실을 야기한다. 화재의 원인은 부싱 하부파손에 따른 절연유 유출과 약 1초 이내 발화점에 도달하는 절연유에 의한 화재의 연쇄반응으로 파악된다. 화재피해의 최소화를 위해 연기감지기, 자동소화설비 등이 구축되어있으나 감지기의 동작 및 소화가스 방출지연 등으로 화재진화를 위한 골든타임 확보의 부재가 문제되고 있다. 이에 본 연구는 초기 화재진화에 따른 골든타임 확보의 중요성에 따라 화재확산을 방지하고 절연유 누출을 차단하는 능동적 메커니즘의 필요에 따라 수행되었다. 따라서 화염에 의해 팽창하는 고온형상 유지물질과 기계적 화염차단장치를 적용한 부싱방화구조체를 개발하였다. 실제 부싱 및 프렌지규격을 적용하여 제작된 변압기모형에 부싱방화구조체를 설치하여 실규모 화재실험을 수행하였다. 초기화염으로부터 3초내에 정확한 위치와 높이에 부싱방화구조체가 작동함을 확인하였으며 이는 실제 변압기화재 시 화염 확대를 효과적으로 차단할 수 있을 것으로 사료된다.

출력전력 백-오프 구간을 확장시킨 고출력 고효율 불균형 도허티 전력증폭기 (High Power and High Efficiency Unbalanced Doherty Amplifier used to Extend the Output Power Back-off)

  • 장동희;김지연;김종헌
    • 한국ITS학회 논문지
    • /
    • 제10권5호
    • /
    • pp.99-104
    • /
    • 2011
  • 본 논문에서 출력 전력 백-오프 구간을 확장하기 위한 고출력 고효율 불균형 도허티 전력 증폭기를 제안하였다. 제안된 불균형 전력증폭기는 기존의 대칭형 도허티 전력증폭기처럼 주 증폭기와 보조 증폭기에 같은 트랜지스터를 사용하는 구조이며 주 증폭기의 출력에 연결되어 있는 ${\lambda}/4$ 변환기의 임피던스를 변형하여서 구간을 확장할 수 있다. 제안된 불균형 도허티 전력증폭기는 기존의 백-오프 출력 구간을 확장하기 위한 비대칭 도허티 전력증폭기와 비교해서 구조가 더 간단함에도 불구하고 유사한 효율과 선형성 특성을 갖는다. 제안된 증폭기의 성능을 증명하기 위해서 CDMA2000 1FA 신호를 입력으로 사용하여 46 W 도허티 전력증폭기를 설계 및 제작하였다. 제작된 불균형 도허티 전력증폭기에서 35 %의 효율과 885 kHz 오프셋 주파수에서 ACPR -34 dBc 그리고 1.98 MHz 오프셋 주파수에서 ACPR -35.6 dBc를 얻었다.

800kV GIS 개발을 위한 기본연구 (The Basic Study on 800kV GIS Development)

  • 김정배;양대일;송원표;이철현;노철웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1341-1343
    • /
    • 1995
  • The maximum transmission voltage in our country is going to change 345kV into 765kV owing to the increase of Electrical Power Demand and power System Stability. Our company is developing 800kV GIS and 765kV Transformer which are main equipments in 765kV substation. This paper describs the specification on 800kV GIS which we prepared for 800kV 8,000A 50kA GIS development. This specification is supported by Public Standards and Data. And, we are designing the 800kV GIS on this specification and drawing up the 800kV GIS layout for type test.