Harmonic Effects and Consideration in Power Converter and Component (전력변환장치의 고조파 영향 및 연구동향)

  • Cho Sung-Joon;Kim Tae-Wan;Woo Myung-Ho;Seo Kwang-Duk
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.467-470
    • /
    • 2001
  • Power electronic converters generate the harmonic voltage and current, and these harmonics have the harmful effects on the various components. For example, passive components such as capacitor and inductor, transformer, motor and other components are mainly affected in the power electronic system. Thus, the design and manufacturing of the power converters, which have the harmonic-free or mitigation strategies, are required. In particular, the lifetime and durability of these components are main requirement for enhancing the overall stability of the system. So, in this paper, the harmonics-related problems to the neighbouring components and mitigation research trends are presented.

  • PDF

A New Dual-Active Soft-Switching Converter for an MTEM Electromagnetic Transmitter

  • Wang, Xuhong;Zhang, Yiming;Liu, Wei
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1454-1468
    • /
    • 2017
  • In this study, a new dual-active soft-switching converter is proposed to improve conversion efficiency and extend the load range for an MTEM electromagnetic transmitter in geological exploration. Unlike a conventional DC/DC converter, the proposed converter can operate in passive soft-switching, single-active soft-switching, or dual-active soft-switching modes depending on the change in load power. The main switches and lagging auxiliary switches of the converter can attain soft-switching over the entire load range. The conduction and switching losses are greatly reduced compared with those of ordinary converters under the action of the cut-off diodes and auxiliary windings coupled to the main transformer in the auxiliary circuits. The conversion efficiency of the proposed converter is significantly improved, especially under light-load conditions. First, the working principle of the proposed converter is analyzed in detail. Second, the relationship between the different operating modes and the load power is given and the design principle of the auxiliary circuit is presented. Finally, the Saber simulation and experimental results verify the feasibility and validity of the converter and a 50 kW prototype is implemented.

Improvement Method of SVR Control in Power Distribution System Interconnected Distributed Generator (분산전원이 연계된 배전계통에 있어서 선로전압조정장치(SVR)의 전압제어 개선방안)

  • Lee, Hyun-Ok;Huh, Jae-Sun;Kim, Byung-Ki;Rho, Dae-Seok;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.224-229
    • /
    • 2014
  • This paper presents the novel voltage control method in power distribution system with distributed generators. The voltage in distribution systems is regulated by Under Load Tap Changer(ULTC) of substation and pole transformer of primary feeders. Recently, Step Voltage Regulator(SVR) is getting located at distribution feeders to regulate effectively voltage of primary feeders. But the effectiveness of SVR decreases due to independent operation between SVR and ULTC, and also the existing Line Drop Compensator(LDC) method considering the distributed generators may be not able to regulate the proper voltage in a permissible range. Thus, this paper presents a optimal voltage control algorithm of SVR by using the secondary voltage data of main transformer in substation.

Series Compensated AC Voltage Regulator using AC chopper with Auxiliary Transformer (교류쵸퍼와 보조변압기를 사용한 직렬보상형 교류전압제어장치)

  • 류홍제;김종수;임근희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.463-467
    • /
    • 2003
  • This paper describes an AC voltage regulator using AC chopper and auxiliary transformer which is series connected with main input. It has many advantages such as fast voltage control, high efficiency and low THD. A detail study of step down AC voltage regulator is described and two kinds of novel step-up/down voltage regulator for AVR application are proposed. The operation principle and PWM method of the proposed regulator are described. Experimental results show that it can be used as AC voltage regulator for special purpose very efficiently.

Analysis of Transient Voltage by Lightning Stroke at 345kV Step-up Transformer (345kV 승압용 변전소의 뇌격에 의한 이상전압 해석)

  • Cho, Man-Young;Shin, Ho-Jeon;Huh, Jae-Sun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.95-101
    • /
    • 2012
  • Typically, large scale power generation facilities are linked to 345kV transmission line through a step-up transformer. If the value of transient voltage by generating lightning stroke is large more than electric equipment's BIL, devices insulation is destroyed. LA(Lighting Arrester) is used as a main means of prevention. However, the installation of LA takes the constraints of installation place and expensive installation costs. Therefore, we need to carefully study whether installation of installation can be omitted and the most efficient place of installation. In this paper, we simulated the transient voltage detected by lightning stroke at each equipments in the 345kV transmission power grid by using EMTP-RV program.

A Operation characteristics of the HB inverter for Remote Plasma Source (리모트 프라즈마 전원용 하프 브리지 인버터의 운전 특성)

  • Kim S.S.;Won C.Y.;Choi D.K.;Choi S.D.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.611-615
    • /
    • 2003
  • In this paper, a operation characteristics and analysis of the HB(half bridge) inverter for remote plasma system are studied. the remote plasma system is cleaning system for the chemical vapor deposition (CVD) chamber in semiconductor processing. The remote plasma system is powered by the RF generator The main power stage of the RF generator is used for the HB PWM inverter with an low pass filter in the secondary circuit of the transformer. The detailed mode analysis of HB invertor was described. The operation characteristics of Remote Plasma Source are verified by simulation and experimental results.

  • PDF

A Study on Characteristic of Power Conversion System in Electric Railway Vehicle According to Contact Loss in Feeding System Considering Characteristic of Rigid Bar (강체전차선로의 특성을 고려한 급전시스템에서 이선에 따른 철도차량 전력변환장치에 대한 특성에 관한 연구)

  • Jung, No-Geon;Lee, Hwan;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.520-525
    • /
    • 2016
  • In this paper, Characteristic of power conversion unit of a railway vehicles according to contact loss in feeding system that applied impedance of rigid conductor is analyzed. It applied impedance of rigid bar in modeling of electric railway system. Railway vehicles are performed of modeling based on the performance of the electric railway vehicle. Effects of the contact loss in the power conversion unit were analyzed via main transformer of railway vehicle, the input and output voltage characteristics of the converter through contact loss was generated after linking the vehicle with feeding system.

A STUDY ON EFFECTIVE APPLICATION OF SURGE ARRESTER BETWEEN THE SWITCHYARD AND MAIN TRANSFORMER IN POWER PLANT (발전소내 스위치야드 및 주변압기간 연결선로의 적정 피뢰기 위치 선정)

  • Lee, Heung-Chan;Ham, Young-Soo;Jung, Gi-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.503-505
    • /
    • 1995
  • The surge arrester plays a vital role in the protection of substation against transient overvoltages resulting from lightning surges and system switching operations. The proper selection and application of the surge arrester is an integral part of the process of substation equipment insulation level selection. The paper outlines the basic consideration in modeling the lightning stroke, the surge arrester, and the system to be protected. The paper discusses the results of various cases simulated using the alternative transient computer program to evaluate the separation effects.

  • PDF

Economic Evaluation far the Application of the Distribution Automation System (배전자동화시스템 적용을 위한 경제성 평가)

  • Hong, Soon-Hak;Ha, Bok-Nam;Kim, Ho-Yong;Jung, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.36-38
    • /
    • 1993
  • This study considers the economic aspect of the distribution automation system, which is the decision-making criteria of the electric utilities for the investment. The feeder automation candidate region is divided into two types of the urban and the rural. The total investment cost of the feeder automation for each type is estimated. The annual cost, is also estimated, by finding the fixed charge rate. To compare the annual cost and the economic effect cost, for the investment decision-making, the costs are quantitatively estimated on the following effects : the manpower replacement, the outage cost saving, the main transformer utilization improvement, the feeder utilization improvement, and the line loss reduction.

  • PDF

Design of New IEC 61850 Logical Node about Main Transformer Local Unit (변압기 Local Unit의 IEC61850 Logical Node 설계)

  • Choi, D.H.;Kim, M.H.;Yang, H.J.;Choi, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.511-512
    • /
    • 2007
  • 변전소 자동화 시스템은 변전소 내의 주요 전기적 데이터들을 DB화 하여 그 트렌드 및 이벤트 내역을 관리하고 각종 제어를 수행하고 상태를 감시하는 시스템이다. 현재 전 세계적으로 IEC 61850 프로토콜을 적용하고 그 목적에 맞게 Interoperability를 구현하려는 노력이 진행되고 있으며 이에 맞추어 변전소 및 Utility에 적용되는 많은 시스템들이 IEC 61850의 적용에 박차를 가하고 있는 상황이다. 이에 따라 변전소 내의 주요기기중의 하나인 주 변압기에 설치되어 변압기의 상태를 감시하고 관리하는 IED인 변압기 Local Unit에 사용할 수 있는 새로운 IEC 61850 Local Unit의 Logical Node를 설계한다.