• Title/Summary/Keyword: Main Disc

Search Result 130, Processing Time 0.024 seconds

A Study on Rattle Noise of Automotive Manual Transmission by way of Torsinal Characteristics of a Clutch Disc (클러치 비틀림특성에 의한 자동차 수동변속기 치타음에 관한 연구)

  • Hong, D.P.;Chung, T.J.;Tae, S.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.3
    • /
    • pp.79-89
    • /
    • 1995
  • Rattle noise occurs at manual transmission as idling and driving of a automotive. It can be solved by torsional characteristics of a clutch disc. A clutch disc consist of a region of pre-damper and main-damper. Rattle noise is affected by pre-damper and main-damper equipped for a torsional spring and friction washer. Pre-damper range covers noise radiating from manual transmission when engine is idling and main-damper range covers noise when engine is driving. The aim of this reserch is to clear transmission rattle noise by way of torsional characteristics of a clutch disc. The experiment is carried out as idling and driving of a automobile equipped for 1.5L MPI engine, dry single-disc type clutch and manual transmission. In this study, the results show for a vibration of manual transmission as idling and driving can be cleared by a clutch disc of Pre-damper type.

  • PDF

Development of the Wheel Disc Spinning Machine (휠 디스크 스피닝 성형기 개발)

  • Kang, Jung-Sik;Kang, E-Sok;Lee, Hang-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.6
    • /
    • pp.58-65
    • /
    • 1999
  • The spinning machine has been developed for a bus and truck wheel disc which is manufactured by spinning process method. This machine has the mechanical structure with bed, 2-column, cross head, 2-vertical slide, 2-horizontal slide with forming roller, clamp slide and main spindle similar to large size vertical lathe. Main spindle attached the mandrel is rotated about 500rpm drived by 280kW power DC motor, and a rotating black material pressed on the mandrel with the clamp slide is spinformed by 2-forming rollers which are attached inner end of the 2-horizontal slides. The 2-vertical and 2-horizontal slides are actuated by the hydraulic cylinder which is controlled by the servo valve individially, and these servo valves are controlled by control signal of the CNC controller which is computed with position signal feedbacked from the encoder sensor. The developed machine can manufacture wheel disc of various section profile without mandrel change because section profile is easily modified using program editing in the CNC controller processor. The wheel disc manufactured by spinning process method has many advantages that the endurance is increased by 2 times and the weight is decreased by 30% compared with a conventional disc.

  • PDF

Computed Tomographic Images of Vertebral Disc Herniation in Dogs (개에서 컴퓨터 단층 촬영 검사를 통한 추간판 탈출증 진단례)

  • 이기창;송경진;권정국;최민철
    • Journal of Veterinary Clinics
    • /
    • v.20 no.4
    • /
    • pp.519-522
    • /
    • 2003
  • An appearance of herniated intervertebral disc into thoracolumbar vertebral canal was evaluated in two patients using computed tomography (CT). Before CT scanning, plain radiography and myelography were performed in both cases. CT images were compared to those of myelography. Dogs were positioned in sternal recumbency under inhalation anesthesia and transverse slices with 2 mm thickness were obtained around thoracolumbar region. The transverse CT images were examined using both vertebral and spiral window mode. The most common findings on CT images were loss of vertebral canal epidural fat, bulging of vertebral canal disc margins, displacement of spinal cord and flatted vertebral canal. Whereas, narrowed intervertebral disc space and simple extradural pattern were the main findings on plain and contrast radiographs. CT imges showed the extent of the herniated disc lesion, type II intervertebral disc hernation, and the displacement of spinal cord in detail in both occations. It is considered that degree and precise localization of the intervertebral disc herniation and subtle lesion of spinal cord could be identified accurately using computed tomography.

Dynamic Characteristics of Proportional Flow Control Valve with Large Capacity (대용량 비례 유량제어밸브 동특성 분석)

  • Jung, G.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.1
    • /
    • pp.20-27
    • /
    • 2010
  • Electromagnetic control valves have been used for almost 20 years. As the solenoid modulating technology advances, its applications are extending to various industrial fields such as nuclear and fossil fuel power plants, chemical plants and refineries. Proportional solenoid valve for large flow control is designed with two-stage configuration to meet the required actuating force on the main disc and its position is stabilized by the self-controlled system. In this research, main disc dynamics is analyzed with linearized system model which is derived from the mathematical equations describing its nonlinear behavior. Major design parameters of the valve control system that affect the response and stability are also studied with root locus method. The linear dynamic analysis results are verified with simulations in time-domain.

  • PDF

Design Optimization to achieve an enhanced flatness of a Lab-on-a-Disc for liquid biopsy (액체생검용 Lab-on-a-Disc의 평탄도 향상을 위한 최적화)

  • Seokkwan Hong;Jeong-Won Lee;Taek Yong Hwang;Sung-Hun Lee;Kyung-Tae Kim;Tae Gon Kang;Chul Jin Hwang
    • Design & Manufacturing
    • /
    • v.17 no.1
    • /
    • pp.20-26
    • /
    • 2023
  • Lab-on-a-disc is a circular disc shape of cartridge that can be used for blood-based liquid biopsy to diagnose an early stage of cancer. Currently, liquid biopsies are regarded as a time-consuming process, and require sophisticated skills to precisely separate cell-free DNA (cfDNA) and circulating tumor cells (CTCs) floating in the bloodstream for accurate diagnosis. However, by applying the lab-on-a-disc to liquid biopsy, the entire process can be operated automatically. To do so, the lab-on-a-disc should be designed to prevent blood leakage during the centrifugation, transport, and dilution of blood inside the lab-on-a-disc in the process of liquid biopsy. In this study, the main components of lab-on-a-disc for liquid biopsy are fabricated by injection molding for mass production, and ultrasonic welding is employed to ensure the bonding strength between the components. To guarantee accurate ultrasonic welding, the flatness of the components is optimized numerically by using the response surface methodology with four main injection molding processing parameters, including the mold & resin temperatures, the injection speed, and the packing pressure. The 27 times finite element analyses using Moldflow® reveal that the injection time and the packing pressure are the critical factors affecting the flatness of the components with an optimal set of values for all four processing parameters. To further improve the flatness of the lab-on-a-disc components for stable mass production, a quarter-disc shape of lab-on-a-disc with a radius of 75 mm is used instead of a full circular shape of the disc, and this significantly decreases the standard deviation of flatness to 30% due to the reduced overall length of the injection molded components by one-half. Moreover, it is also beneficial to use a quarter disc shape to manage the deviation of flatness under 3 sigma limits.

  • PDF

Narrative Review of Pathophysiology and Endoscopic Management of Basivertebral and Sinuvertebral Neuropathy for Chronic Back Pain

  • Hyeun Sung Kim;Pang Hung Wu;Il-Tae Jang
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.4
    • /
    • pp.344-355
    • /
    • 2023
  • Chronic lower back pain is a leading cause of disability in musculoskeletal system. Degenerative disc disease is one of the main contributing factor of chronic back pain in the aging population in the world. It is postulated that sinuvertebral nerve and basivertebral nerve main mediator of the nociceptive response in degenerative disc disease as a result of neurotization of sinuvertebral and basivertebral nerve. A review in literature is done on the pathoanatomy, pathophysiology and pain generation pathway in degenerative disc disease and chronic back pain and management strategy is discussed in this review to aid understanding of sinuvertebral and basivertebral neuropathy treatment strategies.

A study on the improvement of frictional performance of friction material for automobile brake by spray treatment (용사처리에 의한 자동차 브레이크용 마찰재료의 마찰성능개선에 관한 연구)

  • 김윤해;배창원;손태관
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.67-76
    • /
    • 1998
  • Friction materials for brake linings and clutches have severe performance requirements. The principal function of such frictional elements is to convert kinetic energy to heat, and then either to absorb or to dissipate heat. In order to achieve these objectives, the coefficient of friction must be as high as possible, independent of variations in operating conditions, and the necessary energy conversion must be accomplished with a minimum of wear on the contacting parts. In this study, Al powder, Al bronze powder and Mo powder used in general for automobile brake was sprayed on automobile brake disc to restrain rust and to maintain friction performance. Dynamo and corrosion tests have been carried out. It is concluded that the sprayed disc with Al bronze powder has the most improved frictional performance and anti-corrosive characteristics. The main results obtained can be summarized as follows; 1. From the corrosion current density test for gray cast iron and sprayed disc with powders of Al, Al bronze and Mo, it was cleared that the spray treatment with Al bronze powder showed the most superior anti-corrosive characteristics than other powders. 2. By anode polarization toward the noble direction from corrosion potential, corrosion current density with sprayed brake disc by Al-bronze powder was the lowest. 3. Mean frictional coefficients obtained from dynamo test are as follows : the sprayed disc with Al(99.99%) powder was 0.190 ; the sprayed disc with Al-bronze powder was 0.312 ; the sprayed disc with Mo powder was 0.257 ; the non-sprayed disc of gray cast iron was 0.331. In the case of the sprayed disc Al-bronze powder showed the most excellent frictional characteristics . 4. Amount of burnish quantity obtained from burnish test by dynamometer is as follows : the sprayed disc with Al-powder was 1.079 mm : the sprayed disc with Al-bronze powder was 0.155 mm : the sprayed disc with Mo powder was 0.253 mm : the non-sprayed disc of gray cast iron was 0.241 mm. Al-bronze powder also showed the most excellent burnish characteristics.

  • PDF

Study on Tilt of 4-Wire Actuator in Optical Disc (광디스크용 4와이어 구동기의 경사에 관한 연구)

  • 한창수;서현석;이정현;원종화;김수현;곽윤근
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.7
    • /
    • pp.52-60
    • /
    • 1998
  • In optical disc system, 4-wire actuator has undesired tilt which degenerates the performance of RF signal. This tilt occurs from moment around the axis parallel to the tangential direction of the disk. The main reason of the moment is the coupling effect between focus driving system and tracking driving system. This paper constructed tilt mechanism and analyzed tilt quantity due to the moment based on structural analysis and magnetic field analysis. And the experiment about tilt was executed. The results were compared and discussed about the difference. Then, the design method for reducing tilt angle was suggested.

  • PDF

Cost-Effectiveness Analysis of Cervical Anterior Fusion and Cervical Artificial Disc Replacement in the Korean Medical System

  • Lee, Hyosang;Kim, Ui Chul;Oh, Jae Keun;Kim, Taehyun;Park, Sohee;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.1
    • /
    • pp.83-89
    • /
    • 2019
  • Objective : This study is a retrospective cost-benefit analysis of cervical anterior interbody fusion and cervical artificial disc replacement, which are the main surgical methods to treat degenerative cervical disc disease. Methods : We analyzed 156 patients who underwent anterior cervical disc fusion and cervical artificial disc replacement from January 1, 2008 to December 31, 2009, diagnosed with degenerative cervical disc disorder. In this study, the costs and benefits were analyzed by using quality adjusted life year (QALY) as the outcome index for patients undergoing surgery, and a Markov model was used for the analysis. Only direct medical costs were included in the analysis; indirect medical costs were excluded. Data were analyzed with TreeAge Pro $2015^{TM}$ (TreeAge Software, Inc, Williamstown, MA, USA). Results : Patients who underwent cervical anterior fusion had a total cost of KRW 2501807/USD 2357 over 5 years and obtained a utility of 3.72 QALY. Patients who underwent cervical artificial disc replacement received 4.18 QALY for a total of KRW 3685949/USD 3473 over 5 years. The cumulative cost-effectiveness ratio of cervical spine replacement surgery was KRW 2549511/QALY (USD 2402/QALY), which was lower than the general Korean payment standard. Conclusion : Both cervical anterior fusion and cervical artificial disc replacement are cost-effective treatments for patients with degenerative cervical disc disease. Cervical artificial disc replacement may be an effective alternative to obtain more benefits.

Analysis of the Friction Characteristics of Transmission Clutch of a Wheel Excavator (휠 굴삭기용 변속기의 클러치 마찰특성 분석)

  • Lee, Yong Bum;Kim, Kwang Min
    • Tribology and Lubricants
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • Hydraulic transmission is the main component delivering power to the drive wheels of an excavator during forward and backward movement, and it has low speed, high torque and high speed, low torque gear change ratios as a forward/backward two-speed main function. It also has additional function of ensuring that the excavator is stably fixed on the ground with the built-in parking brake during excavation operations. In this study, optimal design specifications are determined by modeling and simulating about the multi-disc-type friction clutch, which is the main component improving the reliability of the hydraulic transmission for a 14-ton wheel excavator, and the friction properties of the transmission clutch are analyzed by performing sample tests.