• Title/Summary/Keyword: Magnetization measurement

Search Result 138, Processing Time 0.032 seconds

T1 Measurement in PRESS

  • Kang, Sei-Kwon;Choe, Bo-Young;Suh, Tae-Suk;Lee, Hyoung-Koo
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.116-116
    • /
    • 2001
  • Purpose: PRESS is one of the representative sequences in MRS, but still, we do not have the formul describing the steady state magnetization of it. So, we derive the equation of th magnetization as a function of the echo time and the repetition time, and compare it wit phantom experiments. Method: PRESS consists of three 180 pulses and the additional crusher gradients whic destroy the unwanted coherences of the magnetization. Using the simple vector model, w derive a formula which describes the behaviour of the magnetization In PRESS and compa the results with the phantom experiment. Also, we explore the results of the T1 from STEAM, PRESS and the simple exponential.

  • PDF

MAGNETIC FIELD DEPENDENCE OF MAGNETIZATION REVERSAL BEHAVIOR IN Co/Pt MULTILAYERS.

  • Cho, Yoon-Chul;Choe, Sug-Bong;Shin, Sung-Chul
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.279-286
    • /
    • 2000
  • Magnetic field dependence of magnetization reversal in Co/Pt multilayers has been quantitatively investigated. Serial samples of Co/Pt multilayers have been prepared by dc-magnetron sputtering under various Ar pressure. Magnetization reversal was monitored by magnetization viscosity measurement and direct domain observation using a magneto-optical microscope system, and the wall-motion speed and the nucleation rate R were determined using a domain reversal model based on time-resolved domain reversal patterns. Both and R were found to be exponentially dependent on the reversing applied field. From the exponential dependencies, the activation volumes of the wall motion and nucleation could be determined based on a thermally activated relaxation model, and the wall-motion activation volume was revealed to be slightly larger than the nucleation activation volume.

  • PDF

Anisotropic Magnetoresistance Analysis of Permalloy Film Using 2-dimensional Magnetization Vector Measurement (2차원 자화벡터를 이용한 퍼멀로이 박막의 이방성자기저항 해석)

  • Lee, Young-Woo;Hu, Yong-Kang;Lim, Jae-Joon;Kim, Cheol-Gi;Kim, Chong-Oh;Yoon, Tae-Sick
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.4
    • /
    • pp.115-119
    • /
    • 2004
  • We measured in-plane 2 dimensional magnetization vector using two pick-up coil sets and investigate the relationship between magnetization vector and anisotropic magnetoresistance. We can determine magnetization vector by measuring magnetic moment in x and y direction simultaneously. As the uniaxial magnetic anisotropy of permalloy film increases, magnetoresistance approaches the expectation which is calculated from the angle between current vector and magnetization vector. Magnetoresistance ratio is linearly proportional to the y moment magnitude which is parallel to the current direction.

Characteristics of Isolator for material parameter (페라이트 소재변수에 따른 아이솔레이터 특성 연구)

  • Jun, Dong-Suk;Lee, Hong-Yeol;Kim, Dong-Young;Lee, Sang-Seak
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.119-122
    • /
    • 2003
  • This paper describes characteristics for insertion losses of Isolator have an effect on material parameter. One purpose of the paper is to present insertion loss on this resonator for magnetic loss, dielectric loss, magnetic field and saturation magnetization. Another is to study the effect of propeller resonator on response characteristics. In this paper, the analysis and measurement of the response characteristics were carried out for the isolator prototype. The measurement results agreed on the simulation results and acquire insertion loss $0.18\;{\sim}\;0.24dB$, return loss 27dB, isolation 27dB and bandwidth 500MHz on this condition saturation magnetization 550G, dielectric loss 0.0004, magnetic loss 20 and dielectric constant 14.

  • PDF

Study on Basic Magnetic Characteristics in New Magnetic Materials (새 자성 재료의 기초자기특성 연구 (1) 자성체 기초특성의 새측정법 연구)

  • 이용호;김인수;신용돌;이연숙;이영희
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.85-88
    • /
    • 1991
  • A high sensitive magnetometer using piezoelectric torque sensor was built. The torque produced on the magnetizde sample with small oscillating magnetic field was measured by a piezoelectric sensor. The torque is proportional to the magnetization of the sample. Errors of the measurement for saturation magnetization remain less than 5 % compared to existing standard values.

  • PDF

Microstructural and Magnetic Characterization of Fe Nanosized Powder Synthesized by Pulsed Wire Evaporation

  • Kim, Deok Hyeon;Lee, Bo Wha
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.100-103
    • /
    • 2017
  • We studied the microstructure and magnetic properties of Fe nanosized powder synthesized by the pulsed wire evaporation method. The x-ray diffraction spectrum confirmed that this powder had a pure ${\alpha}$-Fe phase. Scanning electron microscope and transmission electron microscope measurements indicated that the prepared powder had uniform spherical shape with core-shell structure. The mean powder size was about 35 nm and the thickness of the surface passivation layer was about 5 nm. Energy dispersive X-ray spectroscopy measurement indicated that the surface passivation layer was iron oxide. Magnetic field dependent magnetization measurement at room temperature showed that the maximum magnetization of the prepared powder was 177.1 emu/g at 1 T.

Total AC Loss by simultaneously applied AC transport current and AC external magnetic field in BSCCO Tape

  • Park Myungjin;Lim Hyoungwoo;Cha Gueesoo;Lee Jikwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.4
    • /
    • pp.10-13
    • /
    • 2005
  • Transport current and magnetic field which is generated by transport current make AC current - AC mag-netic field condition(AC-AC condition) in AC power application system using HTS tape. Therefore, characteristics of AC loss under the AC-AC condition are necessary to estimate AC loss of power device with accuracy such as HTS transformer. In this paper, we researched transport current loss, magnetization loss by perpendicular magnetic field and total loss which is represented as summation of both losses under the AC-AC condition in single HTS tape. As a result, magnetization loss showed increasing behavior under 65mT and decreasing behavior upper 65mT by influence of transport current. Transport current loss was increased continuously through out whole measurement ranges in the AC-AC condition. Total loss in HTS tape was dominated entirely by magnetization loss.

Development of High-Field ESR System Using SQUID Magnetometer and its Application to Measurement under High Pressure

  • Sakurai, T.;Fujimoto, K.;Okubo, S.;Ohta, H.;Uwatoko, Y.
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.168-172
    • /
    • 2013
  • We have developed a high-field and high-frequency ESR system using a commercially available magnetometer equipped with the superconducting quantum interference device (SQUID). This is magnetization detection type ESR and ESR is observed as a change of the magnetization at the resonance condition under irradiation of the electromagnetic wave. The frequency range is from 70 to 315 GHz and the maximum magnetic field is 5 T. The sensitivity is estimated to be $10^{13}$ spins/G. The advantage of this system is that the high-field ESR measurements can be made very easily and quantitatively. Moreover, this high-field ESR can be applied to the measurements under pressure by using a widely used piston-cylinder pressure cell.

The change of magnetic microstructure with Co-22%Cr film thicknesses (Co-22%Cr 자성합금박막에서 박막두계에 따른 자기미세구조 변화)

  • 송오성
    • Journal of Surface Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.261-265
    • /
    • 1998
  • We investigated compositional separation of Co-23%Cr magnetic alloy thin films with varying film thicknesses. Saturation magnetization and magnetic microstructures were investigated using vibrating sample magnetometer (VSM) and scanning probe microscope (SPM), respectively. Saturation magnetization was as 700 emu/cc for films below 50 nm-thick, and changed to 430 emu/cc for the ones above 2000 nm-thick. This may be due to increment of molar volume of Cr-enriched phase as film thickness increases. The surface grain size in AFM (atomic force microscope) measurement becomes larger as film thickness increases. The MFM (magnetic force microscope) reveals that magnetic microstructure is changed from the fine spherical domains to the maze type domains as film thickness increases. We conclude that employing thickness of Co-22%Cr films below 50 nm is favorable for high density recording in order to enhance perpendicular saturation magnetization and SNR (signal to noise ratio).

  • PDF