• Title/Summary/Keyword: Magnetic selection

Search Result 165, Processing Time 0.023 seconds

A study on the Effective Cutting Conditions of Cage Motor Rotor(2) (농형회전자의 유효절삭조건에 관한 연구(2))

  • 김희남
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.30-36
    • /
    • 1995
  • This paper proposed on the effective cutting conditions of cage motor rotor by turning. If you want to introduce automatic manufacturing system into the cutting process of cage motor rotor, the selections of effective cutting conditions are necessary. The cutting process of cage motor rotor requires the precision and the out of roundness of cage motor rotor. The surface roughness of cutting face. it is very important factor with effect on the magnetic flux density of cage motor rotor. The purpose of this study is to find out the effects of cutting condition. upon adapting this results, we will improve the production rate in the cutting process of cage motor rotor. As a result, the selection of cutting conditions are important factors to production rate. And these are chosen by the investigations of cutting characters and surface roughness. The experimental result, showed that the increase of cutting speed caused the decrease of cutting force and the high surface integrity. The increase of feed rate and increase of depth of cut caused the increase of cutting force and surface roughness. Thus, the effective cutting conditions of cage motor rotor by turing are cutting speed 291m/min, feed rate 0.10mm/rev, depth of cut 0.05mm.

  • PDF

Creep analysis of the FG cylinders: Time-dependent non-axisymmetric behavior

  • Arefi, Mohammad;Nasr, Mehrdad;Loghman, Abbas
    • Steel and Composite Structures
    • /
    • v.28 no.3
    • /
    • pp.331-347
    • /
    • 2018
  • In this paper history of stresses, strains, radial and circumferential displacements of a functionally graded thick-walled hollow cylinder due to creep phenomenon is investigated. The cylinder is subjected to an arbitrary non-axisymmetric two dimensional thermo-mechanical loading and uniform magnetic field along axial direction. Using equilibrium, strain-displacements and stress-strain relations, the governing differential equations of the problem containing creep strains are derived in terms of radial and circumferential displacements. Since the displacements are varying with time due to creep phenomenon, an analytical solution is not available for these equations. Thus, a semi-analytical procedure based on separation of variables and Fourier series together with a numerical procedure is employed. The numerical results indicate that the non-axisymmetric loading and the material grading index have significant effect on stress redistributions. Moreover, by proper selection of material for any combination of non-axisymmetric loading, one can arrive suitable response for the cylinder to achieve optimal design. With some simplifications, the results are validated with the existing literature.

Advanced Imaging Applications for Locally Advanced Cervical Cancer

  • Petsuksiri, Janjira;Jaishuen, Atthapon;Pattaranutaporn, Pittayapoom;Chansilpa, Yaowalak
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.1713-1718
    • /
    • 2012
  • Advanced imaging approaches (computed tomography, CT; magnetic resonance imaging, MRI; $^{18}F$-fluorodeoxyglucose positron emission tomography, FDG PET) have increased roles in cervical cancer staging and management. The recent FIGO (International Federation of Gynecology and Obstetrics) recommendations encouraged applications to assess the clinical extension of tumors rather than relying on clinical examinations and traditional non-cross sectional investigations. MRI appears to be better than CT for primary tumors and adjacent soft tissue involvement in the pelvis. FDG-PET/CT has increased in usage with a particular benefit for whole body evaluation of tumor metabolic activity. The potential benefits of advanced imaging are assisting selection of treatment based upon actual disease extent, to adequately treat a tumor with minimal normal tissue complications, and to predict the treatment outcomes. Furthermore, sophisticated external radiation treatment and brachytherapy absolutely require advanced imaging for target localization and radiation dose calculation.

An Investigation on Solution of Insecurity Sense Using a Music Performing Magnetic Resonance Imaging: Case report (자기공명영상 검사 시 음악을 이용하여 환자의 불안감 해소에 관한 고찰: 사례 보고)

  • Goo, Eun-Hoe;Kang, Soo-Cheol
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.59-62
    • /
    • 2009
  • The purpose of this study is to know about solution of insecurity sense for solving the tediousness and inducing comfortableness in long time MRI examination. Studies were examined with total of 117 patients that the intention expression of self is possible for a month without dividing man and woman in november 2006. Examination methods were filled in questionnaire after testing using Siemens Impact 1.0T. The musical art were selected through intranet search and record sale inquiry using CD player and speaker. That kind of a music were selected with Korean classical music's 10 chapter, pop song 10's chapter, classic's 10 chapter and Korean popular song's 10 chapter. With analytical method, patients of under 40 year-old, or older and patients using ear-pad and head-phone were classified into groups. As analysis result with question item of questionnaire, most of the patients were showed a favor(36.72%) in playing a music, specially, examination of about 15.38% which uses the headphone prefer a music as older generation of over 40 year-old. In conclusion, with installing of the professional musical program in MRI test rooms, if listening to the music with selection by oneself before testing by season, age, time through development of appropriate musical program will be able to expect the more effect.

  • PDF

Enterovirus 71 infection and neurological complications

  • Lee, Kyung Yeon
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.10
    • /
    • pp.395-401
    • /
    • 2016
  • Since the outbreak of the enterovirus 71 (EV71) infection in Malaysia in 1997, large epidemics of EV71 have occurred in the Asia-Pacific region. Many children and infants have died from serious neurological complications during these epidemics, and EV71 infection has become a serious public health problem in these areas. EV71 infection causes hand, foot and mouth disease (HFMD) in children, and usually resolves spontaneously. However, EV71 occasionally involves the central nervous system (CNS), and induces diverse neurological complications such as brainstem encephalitis, aseptic meningitis, and acute flaccid paralysis. Among those complications, brainstem encephalitis is the most critical neurological manifestation because it can cause neurogenic pulmonary hemorrhage/edema leading to death. The characteristic clinical symptoms such as myoclonus and ataxia, cerebrospinal fluid (CSF) pleocytosis, and brainstem lesions on magnetic resonance imaging, in conjunction with the skin rash of HFMD and the isolation of EV71 from a stool, throat-swab, or CSF sample are typical findings indicating CNS involvement of EV71 infection. Treatment with intravenous immunoglobulin and milrinone are recommended in cases with severe neurological complications from EV71 infection, such as brainstem encephalitis. Despite the recent discovery of receptors for EV71 in human cells, such as the scavenger receptor B2 and P-selection glycoprotein ligand 1, it is not known why EV71 infection predominantly involves the brainstem. Recently, 3 companies in China have completed phase III clinical trials of EV71 vaccines. However, the promotion and approval of these vaccines in various countries are problems yet to be resolved.

A Fast Scheme for Inverting Single-Hole Electromagnetic Data

  • Kim Hee Joon;Lee Jung-Mo;Lee Ki Ha
    • Proceedings of the KSEEG Conference
    • /
    • 2002.04a
    • /
    • pp.167-169
    • /
    • 2002
  • The extended Born, or localized nonlinear approximation of integral equation (IE) solution has been applied to inverting single-hole electromagnetic (EM) data using a cylindrically symmetric model. The extended Born approximation is less accurate than a full solution but much superior to the simple Born approximation. When applied to the cylindrically symmetric model with a vertical magnetic dipole source, however, the accuracy of the extended Born approximation is greatly improved because the electric field is scalar and continuous everywhere. One of the most important steps in the inversion is the selection of a proper regularization parameter for stability. Occam's inversion (Constable et al., 1987) is an excellent method for obtaining a stable inverse solution. It is extremely slow when combined with a differential equation method because many forward simulations are needed but suitable for the extended Born solution because the Green's functions, the most time consuming part in IE methods, are repeatedly re-usable throughout the inversion. In addition, the If formulation also readily contains a sensitivity matrix, which can be revised at each iteration at little expense. The inversion algorithm developed in this study is quite stable and fast even if the optimum regularization parameter Is sought at each iteration step. Tn this paper we show inversion results using synthetic data obtained from a finite-element method and field data as well.

  • PDF

The Study on Current Characteristic according to Core Cutting Degree in Three-Phase Induction Motor with Rectangular Stator Core (사각 고정자 철심을 가지는 삼상 유도전동기의 고정자 철심 절단 각에 따른 전류 특성 연구)

  • Im, Jong-Bin;Kim, Seung-Joo;Kim, Kwang-Soo;Lee, Hyung-Woo;Kim, Sol;Lee, Ju
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1649-1654
    • /
    • 2009
  • Induction motors widely use in industry because structure is simple and hard and cost is generally cheap and they are easy to control. In recently, because of saving steel, ventilation and benefit of frame fixing, rectangular core type induction motors use in industry more and more. This paper presents current characteristic according to stator core cutting degree in three-phase induction motor (IM) with rectangular stator core. According to stator cutting degree, magnetic saturation and paths of flux are changed. Because of these situations, phase currents are unbalance and are produced harmonic components and they cause decrease of efficiency. We analyze each $10^{\circ}$ from $0^{\circ}$ to $30^{\circ}$ using 2-D finite element analysis (FEA). Optimal stator cutting core degree selection supplies stable currents and efficiency improvement. In this paper, loss separation test was executed by IEEE Std. 112-98 Method B and we compare with the result of loss separation by Simulation using FEM and by Experiment.

  • PDF

A Novel 6/5 Switched Reluctance Motor with Short Flux Path: Concept, Design and Analysis

  • Tanujaya, Marully;Lee, Dong-Hee;An, Young-Joo;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.47-53
    • /
    • 2012
  • A novel 6/5 switched reluctance motor (SRM) with short flux path is presented in this paper. The concept of this proposed motor is a novel SR motor with six stator and five rotor poles. The stator is constructed with three independent and physically separate C-core segments, and the rotor is composed of five poles. This motor, with a new selection for the number of stator/rotor poles, achieves a short flux path, which reduces the magnetomotive force required to drive the motor. To verify the performance of the proposed motor, a comparison with conventional SR motors with the same dimensions is executed. The comparison demonstrates that the proposed motor offers better performance in terms of maximum torque production. Furthermore, Finite Element Analysis (FEA) and Matlab/Simulink software are used to predict and simulate the performance of the proposed motor.

A Fast Inversion Method for Interpreting Single-Hole Electromagnetic Data (단일 시추공 전자탐사 자료 해석을 위한 빠른 역산법)

  • Kim, Hee-Joon;Lee, Jung-Mo
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.316-322
    • /
    • 2002
  • A computationally efficient inversion scheme has been developed using the extended Born or localized nonlinear approximation to analyze electromagnetic fields obtained in a single-hole environment. The medium is assumed to be cylindrically symmetric about the borehole, and to maintain the symmetry vertical magnetic dipole source is used throughout. The efficiency and robustness of an inversion scheme is very much dependent on the proper use of Lagrange multiplier, which is often provided manually to achieve desired convergence. In this study, an automatic Lagrange multiplier selection scheme has been developed to enhance the utility of the inversion scheme in handling field data. The inversion scheme has been tested using synthetic data to show its stability and effectiveness.

Minimum-Power Design of Actively-Shielded Transverse Gradient Coils for MRI (MRI용 차폐된 X,Y-경사자계코일의 최소전력설계)

  • Lee, D.R.;Kim, S.K.;Yang, Y.J.;Lee, H.K.;Ahn, C.B.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.307-309
    • /
    • 1996
  • A new design scheme of actively-shielded x,y-gradient coils for Magnetic Resonance Imaging(MRI) is proposed. An actively-shielded x-gradient coil has been designed as an example and the results are presented. In MRI, gradient coils are needed for spatial selection and position coding to obtain the position information of the NMR signal. They are usually switched on and off during imaging and the eddy current induced by the current switching usually degrades the final image quality To reduce or remove this kind of problems, the active shielding has been proposed few years ago. In this paper, a new design scheme for actively-shielded x,y-gradient coils, namely, a minimum-power design scheme using current-loop elements, has been proposed. Its utility in designing MRI gradient coils has been shown by using simulation. The design scheme seems to be useful for actively-shielded transverse gradient coils, even of non-cylindrical or of arbitrary-selected shapes.

  • PDF