• 제목/요약/키워드: Magnetic recovery

검색결과 352건 처리시간 0.031초

Buffer-Optimized High Gradient Magnetic Separation: Target Cell Capture Efficiency is Predicted by Linear Bead-Capture Theory

  • Waseem, Shahid;Udomsangpetch, Rachanee;Bhakdi, Sebastian C.
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.125-132
    • /
    • 2016
  • High gradient magnetic separation (HGMS) is the most commonly used magnetic cell separation technique in biomedical science. However, parameters determining target cell capture efficiencies in HGMS are still not well understood. This limitation leads to loss of information and resources. The present study develops a bead-capture theory to predict capture efficiencies in HGMS. The theory is tested with CD3- and CD14-positive cells in combination with paramagnetic beads of different sizes and a generic immunomagnetic separation system. Data depict a linear relationship between normalized capture efficiency and the bead concentration. In addition, it is shown that key biological functions of target cells are not affected for all bead sizes and concentrations used. In summary, linear bead-capture theory predicts capture efficiency ($E_t$) in a highly significant manner.

Ramsay Hunt Syndrome Complicated by Meningoencephalitis and Radiologic findings: a Rare Case Report

  • Lee, Youdae;Lee, Donghoon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권1호
    • /
    • pp.65-69
    • /
    • 2019
  • Ramsay Hunt syndrome with the complication of encephalitis or meningoencephalitis is rarely reported and uncommon in immunocompetent patients. The radiological manifestations of such cases usually involve the cerebellum and brainstem or exhibit the absence of any abnormality. We report a case of a 78-year-old immunocompetent man hospitalized with Ramsay Hunt syndrome, who later developed meningoencephalitis. The cerebrospinal fluid-study excluded other causes of meningoencephalitis, and the clinical diagnosis indicated varicella zoster virus meningoencephalitis. Magnetic resonance imaging revealed increased signal intensities in the bilateral temporal lobe, midbrain, and pons on T2-weighted imaging, and T2 fluid attenuated inversion recovery and contralateral asymmetric pachymeningeal enhancement. Contrast-enhanced T1-weighted imaging revealed ipsilateral facial nerve enhancement.

Time to Recover Consciousness in Patients with Diffuse Axonal Injury : Assessment with Reference to Magnetic Resonance Grading

  • Park, Sung-Jun;Hur, Jin-Woo;Kwon, Ki-Young;Rhee, Jong-Joo;Lee, Jong-Won;Lee, Hyun-Koo
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권3호
    • /
    • pp.205-209
    • /
    • 2009
  • Objective : This study was conducted to investigate the correlation between the degrees of injury on brain magnetic resonance imaging (MRI) and the time interval to recovery of consciousness in patients with diffuse axonal injury. Methods : From January 2004 to December 2008, 25 patients with diffuse axonal injury were treated at our hospital. We retrospectively investigated the patients' medical records and radiological findings. We divided the patients into three groups according to the grade of MRI finding : grade I, small scattered lesions on the white matter of the cerebral hemisphere; grade II, focal lesions on the corpus callosum; and grade III, additional focal lesions on the brain stem. Result : Seven patients belonged to the grade I group; 10 to the grade II group; and 8 to the grade III group. The mean Glasgow Coma Scale (GCS) score of all patients at the time of admission was 7.28. Recovery of consciousness was observed in 23 of the 25 patients; the remaining two patients never regained consciousness. The time interval to recovery of consciousness (awake status) ranged from 1 day to 125 days (mean 22.1 days) : grade I group patients, within approximately 1 week (mean 3.7 days); grade II group patients, within approximately 2 weeks (mean 12.5 days); and grade III group patients, within approximately 2 months (mean 59.5 days). Conclusion : Our study results suggest a correlation between the mean time interval to recovery of consciousness in patients with diffuse axonal injuries and the degrees of brain injuries seen on MRI. Patients with grade I and II diffuse axonal injuries recovered consciousness within 2 weeks, while patients with grade III injuries required approximately 2 months.

Benefit of Using Early Contrast-Enhanced 2D T2-Weighted Fluid-Attenuated Inversion Recovery Image to Detect Leptomeningeal Metastasis in Lung-Cancer Staging

  • Kim, Han Joon;Lee, Jungbin;Lee, A Leum;Lee, Jae-Wook;Kim, Chan-Kyu;Kim, Jung Youn;Park, Sung-Tae;Chang, Kee-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제26권1호
    • /
    • pp.32-42
    • /
    • 2022
  • Purpose: To evaluate the clinical benefit of 2D contrast-enhanced T2 fluid-attenuated inversion recovery (CE-T2 FLAIR) image for detecting leptomeningeal metastasis (LM) in the brain metastasis work-up for lung cancer. Materials and Methods: From June 2017 to July 2019, we collected all consecutive patients with lung cancer who underwent brain magnetic resonance image (MRI), including contrast-enhanced 3D fast spin echo T1 black-blood image (CE-T1WI) and CE-T2 FLAIR; we recruited clinico-radiologically suspected LM cases. Two independent readers analyzed the images for LM in three sessions: CE-T1WI, CE-T2 FLAIR, and their combination. Results: We recruited 526 patients with suspected lung cancer who underwent brain MRI; of these, we excluded 77 (insufficient image protocol, unclear pathology, different contrast media, poor image quality). Of the 449 patients, 34 were clinico-radiologically suspected to have LM; among them, 23 were diagnosed with true LM. The calculated detection performance of CE-T1WI, CE-T2 FLAIR, and combined analysis obtained from the 34 suspected LM were highest in the combined analysis (AUC: 0.80, 0.82, and 0.89, respectively). The inter-observer agreement was also the highest in the combined analysis (0.68, 0.72, and 0.86, respectively). In quantitative analyses, CNR of CE-T2 FLAIR was significantly higher than that of CE-T1WI (Wilcoxon signed rank test, P < 0.05). Conclusion: Adding CE-T2 FLAIR might provide better detection for LM in the brain-metastasis screening for lung cancer.

A Sequential Orientation Kalman Filter for AHRS Limiting Effects of Magnetic Disturbance to Heading Estimation

  • Lee, Jung Keun;Choi, Mi Jin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1675-1682
    • /
    • 2017
  • This paper deals with three dimensional orientation estimation algorithm for an attitude and heading reference system (AHRS) based on nine-axis inertial/magnetic sensor signals. In terms of the orientation estimation based on the use of a Kalman filter (KF), the quaternion is arguably the most popular orientation representation. However, one critical drawback in the quaternion representation is that undesirable magnetic disturbances affect not only yaw estimation but also roll and pitch estimations. In this paper, a sequential direction cosine matrix-based orientation KF for AHRS has been presented. The proposed algorithm uses two linear KFs, consisting of an attitude KF followed by a heading KF. In the latter, the direction of the local magnetic field vector is projected onto the heading axis of the inertial frame by considering the dip angle, which can be determined after the attitude KF. Owing to the sequential KF structure, the effects of even extreme magnetic disturbances are limited to the roll and pitch estimations, without any additional decoupling process. This overcomes an inherent issue in quaternion-based estimation algorithms. Validation test results show that the proposed method outperforms other comparison methods in terms of the yaw estimation accuracy during perturbations and in terms of the recovery speed.

A Magnetically Coupled AC/DC Boost Converter with Low Reverse Recovery and Conduction Losses

  • Kim, Ju-Young;Park, Ki-Bum;Moon, Gun-Woo;Youn, Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.391-393
    • /
    • 2008
  • A modified boost converter with magnetic coupling is presented to reduce the reverse recovery loss while maintaining low conduction loss of the rectifiers. By utilizing a coupled inductor and a set of diodes, the current passing the boost rectifier is transferred to an auxiliary loop before turn-off, allowing low di/dt for reduced recovery loss. Moreover, the boost inductor is brought inside the bridge rectifier to reduce conduction loss by decreasing the number of conducting diodes during switch turn-off. Experimental results of a 500W prototype are provided to verify the increase in efficiency and validity of the proposed converter.

  • PDF

션트리액터의 자기결합유무에 따른 초전도전류제한기의 전류제한 및 회복특성 분석 (Analysis on Current Limiting and Recovery Characteristics of a SFCL Dependent on Magnetic Coupling of Shunt Reactors)

  • 임성훈;안재민;김진석;문종필;김재철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.277-279
    • /
    • 2008
  • The current limiting and recovery characteristics of a superconducting fault current limiter (SFCL) using shunt reactors were analyzed. Generally, the shunt reactor has a role to distribute the even voltage drop between high-Tc superconducting (HTSC) elements comprising the SFCL. However, the shunt reactors magnetically separated was not contributed to the equal voltage distribution between the HTSC elements. Through the experiments for the SFCL with both the magnetically coupled and magnetically uncoupled shunt reactors, the magnetically coupled shunt reactors were confirmed to improve the current limiting and recovery characteristics of the SFCL.

  • PDF

$\mu$ SMES용 초전도도체의 회복전류 특성 (Recovery Current Characteristics of the SC conductor for a $\mu$ SMES)

  • 김해종;성기철;조전욱;이언용;권영길;류강식;류경우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.807-809
    • /
    • 2000
  • We are developing a small-sized superconducting magnetic energy storage ($\mu$ SMES) magnet with the storage capacity of a few megajoules, which provides electric power with high quality to sensitive electric loads. As the earlier step of the fabrication of the $\mu$ SMES magnet, this paper describes recovery current experimental results of a kA class superconductor. Recovery current of a superconductor was tested in two points of copper ratio and cooling effect.

  • PDF

Neuroimaging Application

  • 정경호
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.37-44
    • /
    • 2002
  • 신경계의 MR영상은 하드웨어적인 발달과 초고속 영상 기법으로 기존의 MRI가 제공해 줄 수 있는 해부학적 정보 외에 기능적인 정보인 물의 확산, 뇌 혈류 정보, 뇌의 기능적 지도화와 뇌대사물의 농도를 측정할 수 있게 되었다. 반전회복영상(Inversion Recovery), 확산(diffusion), 관류(profusion), 기능적(functional)영상, 뇌의 3차원 뇌표면 rendering 및 곡면재구성영상의 임상적인 의의를 알아보고자 한다.

  • PDF