• 제목/요약/키워드: Magnetic liquid

검색결과 417건 처리시간 0.024초

Basic Properties of Micropump with Magnetic Micromachine

  • Hisatomi, Shinichi;Yamazaki, Aya;Ishiyama, Kazushi;Sendoh, Masahiko;Yabukami, Shin;Agatsuma, Shigeto;Morooka, Keiko;Arai, Ken Ichi
    • Journal of Magnetics
    • /
    • 제12권2호
    • /
    • pp.84-88
    • /
    • 2007
  • A micropump with spiral-type magnetic micromachine was fabricated. When a rotating magnetic field was applied, the machine rotated and pumped a surrounding liquid. We experimentally examined the basic properties of this pump. We found that the pressure and the flow rate could be controlled by the rotating frequency, and this pump could work under wide range kinematic viscosity. In addition, we proposed a disposable pump system using the machine. When a plate installed a fluid channel and the machine was set on a stage for generating a rotating magnetic field, the machine worked as the pump.

Ionic liquid coated magnetic core/shell CoFe2O4@SiO2 nanoparticles for the separation/analysis of trace gold in water sample

  • Zeng, Yanxia;Zhu, Xiashi;Xie, Jiliang;Chen, Li
    • Advances in nano research
    • /
    • 제10권3호
    • /
    • pp.295-312
    • /
    • 2021
  • A new ionic liquid functionalized magnetic silica nanoparticle was synthesized and characterized and tested as an adsorbent. The adsorbent was used for magnetic solid phase extraction on ICP-MS method. Simultaneous determination of precious metal Au has been addressed. The method is simple and fast and has been applied to standard water and surface water analysis. A new method for separation/analysis of trace precious metal Au by Magnetron Solid Phase Extraction (MSPE) combined with ICP-MS. The element to be tested is rapidly adsorbed on CoFe2O4@SiO2@[BMIM]PF6 composite nano-adsorbent and eluted with thiourea. The method has a preconcentration factor of 9.5-fold. This method has been successfully applied to the determination of gold in actual water samples. Hydrophobic Ionic Liquids (ILs) 1-butyl-3-methylimidazole hexafluorophosphate ([BMIM]PF6) coated CoFe2O4@SiO2 nanoparticles with core-shell structure to prepare magnetic solid phase extraction agent (CoFe2O4@SiO2@ILs) and establish a new method of MSPE coupled with inductively coupled plasma mass spectrometry for separation/analysis of trace gold. The results showed that trace gold was adsorbed rapidly by CoFe2O4@SiO2@[BMIM]PF6 and eluanted by thiourea. Under the optimal conditions, preconcentration factor of the proposed method was 9.5-fold. The linear range, detection limit, correlation coefficient (R) and relative standard deviation (RSD) were found to be 0.01~1000.00 ng·mL-1, 0.001 ng·mL-1, 0.9990 and 3.4% (n = 11, c = 4.5 ng·mL-1). The CoFe2O4@SiO2 nanoparticles could be used repeatedly for 8 times. This proposed method has been successfully applied to the determination of trace gold in water samples.

Sloshing of liquids in partially filled tanks - a review of experimental investigations

  • Eswaran, M.;Saha, Ujjwal K.
    • Ocean Systems Engineering
    • /
    • 제1권2호
    • /
    • pp.131-155
    • /
    • 2011
  • Liquid sloshing constitutes a broad class of problems of great practical importance with regard to the safety of liquid transportation systems, such as tank trucks on highways, liquid tank carriages on rail roads, ocean going vessels and propellant tanks in liquid rocket engines. The present work attempts to give a review of some selected experimental investigations carried out during the last couple of decades. This paper highlights the various parameters attributed to the cause of sloshing followed by effects of baffles, tank inclination, magnetic field, tuned liquid dampers, electric field etc. Further, recent developments in the study of sloshing in micro and zero gravity fields have also been reported. In view of this, fifteen research articles have been carefully chosen, and the work reported therein has been addressed and discussed. The key issues and findings have been compared, tabulated and summarized.

Angular distributions of the critical current of ReBCO coated conductors in magnetic field up to 5T

  • Mineev, Nikolay A.;Rudnev, Igor A.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권1호
    • /
    • pp.6-9
    • /
    • 2015
  • For many applications of $ReBa_2Cu_3O_{7-x}$ (ReBCO) tapes it is needed to know the anisotropic properties of the used conductor in a broad range of magnetic field. In this paper we present the results of transport measurements on the SuNAM tape (GdBaCuO) with the rotation of the sample in magnetic fields up to 5 T in liquid nitrogen. The critical current over the magnetic field orientation ($I_c({\theta})$) curves demonstrate the appearance of distinct second peak around c-axis in low fields. This peak almost vanishes in the fields over 3 T. The evolution of the ab-peak form is also presented: the peak consistently reduces its height with the magnetic field going up and in the high fields the shoulders rise, changing the type of the distribution. To describe experimental curves the vortex path model was applied to the angular distributions of the critical current in magnetic field. Good agreements of the experimental data with the analytical expressions were obtained that confirm the vortex path model approach.

A Study of Characteristic of Electrical-magnetic and Neutron Diffraction of Long-wire High-superconductor for Reducing Energy Losses

  • Jang, Mi-Hye
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권6호
    • /
    • pp.265-272
    • /
    • 2008
  • In this paper, AC losses of long wire Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist. The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-prob method. And the Magnetic measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O).

Nano-sized Effect on the Magnetic Properties of Ag Clusters

  • Jo, Y.;Jung, M.H.;Kyum, M.C.;Park, K.H.;Kim, Y.N.
    • Journal of Magnetics
    • /
    • 제11권4호
    • /
    • pp.160-163
    • /
    • 2006
  • We have prepared crystalline Ag nanoparticles with an average size of 4 nm in diameter by using an inductively coupled plasma reactor equipped with the liquid nitrogen cooling system. Our magnetic data show that the nano-sized effect of Ag nanoparticles on the magnetic properties is ferromagnetic, instead of a diamagnetic component of the Ag bulk and a superparamagnetic component of magnetic nanoparticles. We have also studied the magnetic properties of Ag-Cu nanocomposites with an opposite concentration profile between surface and core. These comparisons indicate that the ferromagnetic component strongly depends on the surface of Ag nanoparticles, while the paramagnetic component is strongly affected by the outer oxide layer, with the background of a diamagnetic component from the core of Ag.

Skin Effect of Rotating Magnetic Fields in Liquid Bridge

  • Zhang, Yi;Zeng, Zhong;Yao, Liping;Yokota, Yuui;Kawazoe, Yoshi;Yoshikawa, Akira
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.333-343
    • /
    • 2017
  • A rotating magnetic field (RMF) ${\Phi}_1-{\Phi}_2$ model was developed in consideration of the skin effect. The rotating magnetic field's induced three-dimensional flow was simulated numerically, and the influence of the skin effect was investigated. The rotating magnetic field drives the rotating convection in the azimuthal direction, and a secondary convection appears in the radial-meridional direction. The results indicate that ignoring the skin effect results in a smaller azimuthal velocity component and larger radial and axial velocity components, and that the deviation becomes more obvious with the larger dimensionless shielding parameter K.

Content and Distribution of Transition Metals and Rare Earth Elements in Magnetically and Mechanically Separated Brown Coal Ash

  • Malikov, Sh.R.;Pikul, V.P.;Mukhamedshina, N.M.;Sandalov, V.N.;Kudiratov, S.;Ibragimova, E.M.
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.365-369
    • /
    • 2013
  • Coal ash is known to contain a noticeable amount of valuable elements, including transition metals and lanthanides. Therefore it is quite actual problem to extract them for metallurgy and other applications. This paper presents the results of high gradient magnetic and mechanical separation, microscopy, element analyses and optical spectroscopy of brown coal ash taken from the combustion camera and chimney-stalk of Angren thermal power station. The separated magnetic fraction was 3.4 wt.%, where the content of Fe in ferrospheres increased to 58 wt.%. The highest contents of Fe and rare earth elements were found in the fine fractions of $50-100{\mu}m$. Optical absorption spectroscopy of water solutions of the magnetic fractions revealed $Fe^{2+}$ and $Fe^{3+}$ ions in the ratio of ~1:1. The separated coal ash could be used for cleaning of technological liquid waste by means of the high gradient magnetic field.

Non-uniform Distribution of Magnetic Fluid in Multistage Magnetic Fluid Seals

  • Zhongzhong, Wang;Decai, Li;Jing, Zhou
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.299-305
    • /
    • 2017
  • Magnetic fluid, a new type of magnetic material, is a colloidal liquid constituted of nano-scale ferromagnetic particles suspended in carrier fluid. Magnetic fluid sealing is one of the most successful applications of magnetic fluid. As a new type of seal offering the advantages of no leakage, long life and high reliability, the magnetic fluid seal has been widely utilized under vacuum- and low-pressure-differential conditions. In practical applications, for improved pressure capacity, a multistage sealing structure is always used. However, in engineering applications, a uniform distribution of magnetic fluid under each tooth often cannot be achieved, which problem weakens the overall pressure capacity of the seals. In order to improve the pressure capacity of magnetic fluid seals and broaden their applications, the present study theoretically and experimentally analyzed the degree of non-uniform distribution of multistage magnetic fluid seals. A mathematical model reflecting the relationship between the pressure capacity and the distribution of magnetic fluid under a single tooth was constructed, and a formula showing the relationship between the volume of magnetic fluid and its contact width with the shaft was derived. Furthermore, the relationship of magnetic fluid volume to capacity was analyzed. Thereby, the causes of non-uniform distribution could be verified: injection of magnetic fluid; the assembly of magnetic fluid seals; the change of magnetic fluid silhouette under pressure loading; the magnetic fluid sealing mechanism of pressure transmission, and seal failure. In consideration of these causes, methods to improve the pressure capacity of magnetic fluid seals was devised (and is herein proposed).

스퍼터링법으로 경사증착한 $SiO_x$ 박막 표면의 액정 수직 배향 효과 (Homeotropic Alignment Effect for Nematic liquid Crystal on the Treated $SiO_x$ Thin Film Layer by Sputtering Method)

  • 최성호;김병용;김영환;김종환;한정민;오병윤;황정연;명재민;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 학술대회 및 기술세미나 논문집 디스플레이 광소자
    • /
    • pp.66-67
    • /
    • 2006
  • We studied nematic liquid crystal (NLC) alignment effect on the $SiO_x$ thin film deposited $45^{\circ}$ oblique by rf magnetic sputtering system. Pretilt angle and thermal stability characteristic as well as NLC alignment effect were investigated. A uniform liquid crystal alignment effect on the $SiO_x$ thin film was achieved and pretilt angle was about $90^{\circ}$. The thermal stability of the $SiO_x$ thin film was sustained by $200^{\circ}$.

  • PDF